메뉴 건너뛰기




Volumn 24, Issue 3, 2013, Pages 849-855

Immediate loading with LASER-treated surface implant: Two-year resonance frequency analysis follow-up

Author keywords

Immediate loading; Implant stability quotient (ISQ); LASER treated surface implants; Primary stability; Resonance frequency analysis (RFA)

Indexed keywords

AGED; FOLLOW UP; HUMAN; JAW, EDENTULOUS; LOW LEVEL LASER THERAPY; MALE; MATERIALS TESTING; MAXILLA; MIDDLE AGED; PROCEDURES; PROSTHESIS; STANDARDS; TOOTH IMPLANTATION; TOOTH PROSTHESIS; VIBRATION;

EID: 84880100349     PISSN: 10492275     EISSN: 15363732     Source Type: Journal    
DOI: 10.1097/SCS.0b013e31827ca37b     Document Type: Article
Times cited : (2)

References (42)
  • 3
    • 0018589158 scopus 로고
    • Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe von plasmabeschichteten Titanschraubenimplantaten
    • Ledermann P. Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe von plasmabeschichteten Titanschraubenimplantaten. Dtsch Zahnarztl Z 1979;34:907
    • (1979) Dtsch Zahnarztl Z , vol.34 , pp. 907
    • Ledermann, P.1
  • 4
    • 0041458803 scopus 로고
    • Sechsjaehrige klinische Erfahrung mit dem titanplasrnabeschichteten ITI-Schraubenimplantat in der Regio Interforaminalis des Unterkiefers
    • Ledermann PD. Sechsjaehrige klinische Erfahrung mit dem titanplasrnabeschichteten ITI-Schraubenimplantat in der Regio Interforaminalis des Unterkiefers. Schweiz Monatsschr Zahnmed 1983;93:1080-1089
    • (1983) Schweiz Monatsschr Zahnmed , vol.93 , pp. 1080-1089
    • Ledermann, P.D.1
  • 5
    • 0022612152 scopus 로고
    • Titanium plasma spray screw implant system for reconstruction of the edentulous mandible
    • Babbush CA. Titanium plasma spray screw implant system for reconstruction of the edentulous mandible. Dent Clin North Am 1986;30:117-130
    • (1986) Dent Clin North Am , vol.30 , pp. 117-130
    • Babbush, C.A.1
  • 6
    • 0042072188 scopus 로고
    • Implants loaded with fixed provisional prostheses at fixture placement: Nine-year follow-up
    • Schnitman P, Brånemark P-I. Implants loaded with fixed provisional prostheses at fixture placement: nine-year follow-up. J Oral Implantol 1995;21:235-245
    • (1995) J Oral Implantol , vol.21 , pp. 235-245
    • Schnitman, P.1    Brånemark, P.-I.2
  • 7
    • 0033169706 scopus 로고    scopus 로고
    • Immediate loading of transitional implants module: A histological and histomorphometric study in dogs
    • Zubery Y, Bichacho N, Goldschleger M, et al. Immediate loading of transitional implants module: a histological and histomorphometric study in dogs. Int J Period Rest Dent 1999;19:343-353
    • (1999) Int J Period Rest Dent , vol.19 , pp. 343-353
    • Zubery, Y.1    Bichacho, N.2    Goldschleger, M.3
  • 8
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: Results of 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E. Implant-retained mandibular overdentures with immediate loading: results of 226 consecutive cases. Clin Oral Implants Res 1997;8:48-57
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3
  • 9
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multicenter study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP. Long-term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multicenter study with 2359 implants. Clin Oral Implants Res 1997;8:161-172
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 10
    • 54449095335 scopus 로고    scopus 로고
    • Immediate versus early non occlusal loading of dental implants placed flapless in partially edentulous patients. Preliminary results from a randomized controlled clinical trial
    • Merli M, Bernardell F, Esposito M. Immediate versus early non occlusal loading of dental implants placed flapless in partially edentulous patients. Preliminary results from a randomized controlled clinical trial. Int J Periodontics Restorative Dent 2008;28:453-459
    • (2008) Int J Periodontics Restorative Dent , vol.28 , pp. 453-459
    • Merli, M.1    Bernardell, F.2    Esposito, M.3
  • 11
    • 38149137150 scopus 로고    scopus 로고
    • The effectiveness of immediate, early, and conventional loading of dental implants: A Cochrane systemic review of randomized controlled clinical trials
    • Esposito M, Grusovin MG, Willings M, et al. The effectiveness of immediate, early, and conventional loading of dental implants: a Cochrane systemic review of randomized controlled clinical trials. Int J Oral Maxillofac Implant 2007;22:893-904
    • (2007) Int J Oral Maxillofac Implant , vol.22 , pp. 893-904
    • Esposito, M.1    Grusovin, M.G.2    Willings, M.3
  • 12
    • 42149193139 scopus 로고    scopus 로고
    • Five- year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla
    • Fischer K, Stenberg T, Hedin M, et al. Five- year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla. Clin Oral Implants Res 2008;19:433-441
    • (2008) Clin Oral Implants Res , vol.19 , pp. 433-441
    • Fischer, K.1    Stenberg, T.2    Hedin, M.3
  • 13
    • 7944234226 scopus 로고    scopus 로고
    • Predicting osseointegration by means of implant primary stability. A resonance frequency analysis study with delayed and immediately loaded ITI SLA implants
    • Nedir R, Bischof M, Szmukler-Moncler S, et al. Predicting osseointegration by means of implant primary stability. A resonance frequency analysis study with delayed and immediately loaded ITI SLA implants. Clin Oral Implant Res 2004;15:520-528
    • (2004) Clin Oral Implant Res , vol.15 , pp. 520-528
    • Nedir, R.1    Bischof, M.2    Szmukler-Moncler, S.3
  • 14
    • 84873311196 scopus 로고    scopus 로고
    • Clinical outcome of 802 immediately loaded 2-stage sub- merged implants with a newgrit-blasted and acid- etched surface: 12-month follow up
    • Degidi M, Piattelli A, Gehrke P, et al. Clinical outcome of 802 immediately loaded 2-stage sub- merged implants with a newgrit-blasted and acid- etched surface: 12-month follow up. J Prosthet Dent 2008;99:167
    • (2008) J Prosthet Dent , vol.99 , pp. 167
    • Degidi, M.1    Piattelli, A.2    Gehrke, P.3
  • 15
    • 65649128593 scopus 로고    scopus 로고
    • Immediate and early loading of oxidized tapered implants in the partially edentulous maxilla: A 1-year prospective clinical, radiographic, and resonance frequency analysis study
    • Fischer K, Bäckström M, Sennerby L. Immediate and early loading of oxidized tapered implants in the partially edentulous maxilla: a 1-year prospective clinical, radiographic, and resonance frequency analysis study. Clin Implant Dent Relat Res 2009;11:69-80
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 69-80
    • Fischer, K.1    Bäckström, M.2    Sennerby, L.3
  • 16
    • 25144455627 scopus 로고    scopus 로고
    • Surface properties of endosseous dental implants after Nd YAG and CO2 LASER treatment at various energies
    • Park C, Kim S, Kim M et al. Surface properties of endosseous dental implants after Nd YAG and CO2 LASER treatment at various energies. J Oral Maxillofac Surg 2005;63:1522-1527
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 1522-1527
    • Park, C.1    Kim, S.2    Kim, M.3
  • 18
    • 78650553565 scopus 로고    scopus 로고
    • Influence of novel nano-titanium implant surface on human osteoblast behavior and growth
    • Tetè S, Mastrangelo F, Quaresima R, et al. Influence of novel nano-titanium implant surface on human osteoblast behavior and growth. Implant Dent 2010;19:520-531
    • (2010) Implant Dent , vol.19 , pp. 520-531
    • Tetè, S.1    Mastrangelo, F.2    Quaresima, R.3
  • 19
    • 58149187486 scopus 로고    scopus 로고
    • A macro- and nanostructure evaluation of a novel dental implant
    • Tetè S, Mastrangelo F, Traini T, et al. A macro- and nanostructure evaluation of a novel dental implant. Implant Dent 2008;17:309-320
    • (2008) Implant Dent , vol.17 , pp. 309-320
    • Tetè, S.1    Mastrangelo, F.2    Traini, T.3
  • 20
    • 84880122623 scopus 로고    scopus 로고
    • New LASER engineered titanium surfaces in oral implantology
    • Poster 17th EAO Meeting Warsaw Poland
    • Duvina M, Di Narda F, Prosperi M, et al. New LASER engineered titanium surfaces in oral implantology. Poster 17th EAO Meeting Warsaw, Poland. Clin Oral Implants Res 2008;19:392
    • (2008) Clin Oral Implants Res , vol.19 , pp. 392
    • Duvina, M.1    Di Narda, F.2    Prosperi, M.3
  • 21
    • 84880092832 scopus 로고    scopus 로고
    • New LASER implant surfaces: In vitro effect of bone cells adhesion, proliferation and differentiation
    • Poster 17th EAO Meeting Warsaw, Poland
    • Duvina M, Mascherini C, Brancato L, et al. New LASER implant surfaces: in vitro effect of bone cells adhesion, proliferation and differentiation. Poster 17th EAO Meeting Warsaw, Poland. Clin Oral Implants Res 2008;19:393
    • (2008) Clin Oral Implants Res , vol.19 , pp. 393
    • Duvina, M.1    Mascherini, C.2    Brancato, L.3
  • 22
    • 62649135303 scopus 로고    scopus 로고
    • In vitro evaluation of a new LASER surface implant: Cellular adhesion and alkaline phosphatase production test
    • Berardi D, De Benedettis S, Polimeni A, et al. In vitro evaluation of a new LASER surface implant: cellular adhesion and alkaline phosphatase production test. Int J Immunopathol Pharmacol 2009;1:125-131
    • (2009) Int J Immunopathol Pharmacol , vol.1 , pp. 125-131
    • Berardi, D.1    De Benedettis, S.2    Polimeni, A.3
  • 23
    • 80051801982 scopus 로고    scopus 로고
    • Effect of LASER micromachining of titanium on viability and responsiveness of osteoblast-like cells
    • Cei S, Legitimo A, Barachini S, et al. Effect of LASER micromachining of titanium on viability and responsiveness of osteoblast-like cells. Implant Dent 2011;20:285-291
    • (2011) Implant Dent , vol.20 , pp. 285-291
    • Cei, S.1    Legitimo, A.2    Barachini, S.3
  • 24
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 25
    • 0032061729 scopus 로고    scopus 로고
    • Resonance frequency analysis: Measuring implant stability and osseointegration
    • Sennerby L, Maredith N. Resonance frequency analysis: measuring implant stability and osseointegration. Compend Contin Educ Dent 1998;19:493-498
    • (1998) Compend Contin Educ Dent , vol.19 , pp. 493-498
    • Sennerby, L.1    Maredith, N.2
  • 26
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates TW, Meredith N, et al. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18:641-651
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3
  • 27
    • 23044454177 scopus 로고    scopus 로고
    • Resonance frequency analysis of one-stage dental implant stability during the osseointegration period
    • Ersanli S, Karabuda C, Beck F, et al. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol 2005;76:1066-1071
    • (2005) J Periodontol , vol.76 , pp. 1066-1071
    • Ersanli, S.1    Karabuda, C.2    Beck, F.3
  • 28
    • 84880112610 scopus 로고    scopus 로고
    • Monitoring of implant stability in immediate loading by resonance frequency analysis
    • Duvina M, Longoni S, Sartori M, et al. Monitoring of implant stability in immediate loading by resonance frequency analysis. Eur J Implant Prosthodont 2007;3:60
    • (2007) Eur J Implant Prosthodont , vol.3 , pp. 60
    • Duvina, M.1    Longoni, S.2    Sartori, M.3
  • 29
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004;15:428-434
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3
  • 30
    • 84944866100 scopus 로고    scopus 로고
    • Resonance frequency analysis assessment of implants placed with a simultaneous or a delayed approach in grafted and nongrafted sinus sites: A 12-month clinical study
    • Published online ahead of print September 11, doi:10.1111/cid.12002
    • Di Lallo S, Ricci L, Orecchioni S, et al. Resonance frequency analysis assessment of implants placed with a simultaneous or a delayed approach in grafted and nongrafted sinus sites: a 12-month clinical study. Clin Implant Dent Relat Res Published online ahead of print September 11, 2012. doi:10.1111/cid.12002
    • (2012) Clin Implant Dent Relat Res
    • Di Lallo, S.1    Ricci, L.2    Orecchioni, S.3
  • 31
    • 84872040508 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants inserted with a simultaneous grafting procedure: A 5-year follow-up study in man
    • Cassetta M, Ricci L, Iezzi G, et al. Resonance frequency analysis of implants inserted with a simultaneous grafting procedure: a 5-year follow-up study in man. Int J Periodontics Restorative Dent 2012;32:581-589
    • (2012) Int J Periodontics Restorative Dent , vol.32 , pp. 581-589
    • Cassetta, M.1    Ricci, L.2    Iezzi, G.3
  • 33
    • 34547768299 scopus 로고    scopus 로고
    • Immediate loading: A simple protocol to create a passively fitting provisional fixed implant-supported complete denture in 1 day
    • Longoni S, Sartori M, Apruzzese D, et al. Immediate loading: a simple protocol to create a passively fitting provisional fixed implant-supported complete denture in 1 day. Int J Periodontics Restorative Dent 2007;27:369-377
    • (2007) Int J Periodontics Restorative Dent , vol.27 , pp. 369-377
    • Longoni, S.1    Sartori, M.2    Apruzzese, D.3
  • 34
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47:51-66
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 35
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    • O'Sullivan D, Sunnerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implant Res 2004;15:474-480
    • (2004) Clin Oral Implant Res , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sunnerby, L.2    Meredith, N.3
  • 36
    • 34548590572 scopus 로고    scopus 로고
    • Effect on the amount of bone implant contact when splinting immediate loaded dental implants
    • Matsuzaka K, Nakajima Y, Soejima Y, et al. Effect on the amount of bone implant contact when splinting immediate loaded dental implants. Implant Dent 2007;16:309-316
    • (2007) Implant Dent , vol.16 , pp. 309-316
    • Matsuzaka, K.1    Nakajima, Y.2    Soejima, Y.3
  • 37
    • 43249109361 scopus 로고    scopus 로고
    • A finite element analysis of two different dental implants: Stress distribution in the prosthesis, abutment, implant, and supporting bone
    • Quaresma SE, Cury PR, Sendyk WR, et al. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone. J Oral Implantol 2008;34:16
    • (2008) J Oral Implantol , vol.34 , pp. 16
    • Quaresma, S.E.1    Cury, P.R.2    Sendyk, W.R.3
  • 38
    • 34547314988 scopus 로고    scopus 로고
    • Effect of microthread the maintenance of marginal bone level: A 3 year prospective study
    • Lee DW, Choi YS, Park KH, et al. Effect of microthread the maintenance of marginal bone level: a 3 year prospective study. Clin Oral Implant Res 2007;18:465-470
    • (2007) Clin Oral Implant Res , vol.18 , pp. 465-470
    • Lee, D.W.1    Choi, Y.S.2    Park, K.H.3
  • 39
    • 24344449647 scopus 로고    scopus 로고
    • Surface microtopography regulates osteointegration: The role of implant surface microtopography in osteointegration
    • Schwartz Z, Nasazky E, Boyan BD. Surface microtopography regulates osteointegration: the role of implant surface microtopography in osteointegration. Alpha Omegan 2005;98:9-19
    • (2005) Alpha Omegan , vol.98 , pp. 9-19
    • Schwartz, Z.1    Nasazky, E.2    Boyan, B.D.3
  • 40
    • 0036093627 scopus 로고    scopus 로고
    • Comparative investigation of the surface properties of commercial titanium dental implants. Part I: Chemical composition
    • Massaro C, Rotolo P, DeRiccardis F. Comparative investigation of the surface properties of commercial titanium dental implants. Part I: chemical composition. J Mater Sci Med 2002;13:535-548
    • (2002) J Mater Sci Med , vol.13 , pp. 535-548
    • Massaro, C.1    Rotolo, P.2    Dericcardis, F.3
  • 41
    • 0029681619 scopus 로고    scopus 로고
    • Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles aluminium oxide
    • Wennerberg A, Albrektsson T, Andersson B. Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles aluminium oxide. Int J Maxillofac Implants 1996;11:38-45
    • (1996) Int J Maxillofac Implants , vol.11 , pp. 38-45
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3
  • 42
    • 1842840921 scopus 로고    scopus 로고
    • A 2003 update of bone physiology and Wolff 's law for clinicians
    • Frost HM. A 2003 update of bone physiology and Wolff 's law for clinicians. Angle Orthod 2004;74:3-15
    • (2004) Angle Orthod , vol.74 , pp. 3-15
    • Frost, H.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.