메뉴 건너뛰기




Volumn 16, Issue 3, 2014, Pages 394-400

Resonance Frequency Analysis Assessment of Implants Placed with a Simultaneous or a Delayed Approach in Grafted and Nongrafted Sinus Sites: A 12-Month Clinical Study

Author keywords

Bone regeneration; Dental implants; Implant stability; Maxillary sinus augmentation; Resonance frequency analysis (RFA)

Indexed keywords

TOOTH IMPLANT;

EID: 84944866100     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/cid.12002     Document Type: Article
Times cited : (11)

References (35)
  • 1
    • 34548078711 scopus 로고    scopus 로고
    • A literature review on biomaterials in sinus augmentation procedures
    • Browaeys H, Bouvry P, De Bruyn H. A literature review on biomaterials in sinus augmentation procedures. Clin Implant Dent Relat Res 2007; 9:166-177.
    • (2007) Clin Implant Dent Relat Res , vol.9 , pp. 166-177
    • Browaeys, H.1    Bouvry, P.2    De Bruyn, H.3
  • 2
    • 56749160590 scopus 로고    scopus 로고
    • Implant survival rates after maxillary sinus augmentation
    • Del Fabbro M, Rosano G, Taschieri S. Implant survival rates after maxillary sinus augmentation. Eur J Oral Sci 2008; 116:497-506.
    • (2008) Eur J Oral Sci , vol.116 , pp. 497-506
    • Del Fabbro, M.1    Rosano, G.2    Taschieri, S.3
  • 3
    • 72949116984 scopus 로고    scopus 로고
    • Histomorphometric comparison of maxillary pristine bone and composite bone graft biopsies obtained after sinus augmentation
    • Galindo-Moreno P, Moreno-Riestra I, Avila G, etal. Histomorphometric comparison of maxillary pristine bone and composite bone graft biopsies obtained after sinus augmentation. Clin Oral Implants Res 2010; 21:122-128.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 122-128
    • Galindo-Moreno, P.1    Moreno-Riestra, I.2    Avila, G.3
  • 4
    • 80053561165 scopus 로고    scopus 로고
    • Sinus lift with autologous bone alone or in addition to equine bone: an immunohistochemical study in man
    • Artese L, Piattelli A, Di Stefano DA, etal. Sinus lift with autologous bone alone or in addition to equine bone: an immunohistochemical study in man. Implant Dent 2011; 20:383-388.
    • (2011) Implant Dent , vol.20 , pp. 383-388
    • Artese, L.1    Piattelli, A.2    Di Stefano, D.A.3
  • 5
    • 0036718959 scopus 로고    scopus 로고
    • A clinical and histologic evaluation of implant integration in the posterior maxilla after sinus floor augmentation with autogenous bone, bovine hydroxyapatite, or a 20:80 mixture
    • Hallman M, Sennerby L, Lundgren S. A clinical and histologic evaluation of implant integration in the posterior maxilla after sinus floor augmentation with autogenous bone, bovine hydroxyapatite, or a 20:80 mixture. Int J Oral Maxillofac Implants 2002; 17:635-643.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 635-643
    • Hallman, M.1    Sennerby, L.2    Lundgren, S.3
  • 6
    • 77952939340 scopus 로고    scopus 로고
    • Sinus floor augmentation surgery using autologous bone grafts from various donor sites: a meta-analysis of the total bone volume
    • Klijn RJ, Meijer GJ, Bronkhorst EM, Jansen JA. Sinus floor augmentation surgery using autologous bone grafts from various donor sites: a meta-analysis of the total bone volume. Tissue Eng Part B Rev 2010; 16:295-303.
    • (2010) Tissue Eng Part B Rev , vol.16 , pp. 295-303
    • Klijn, R.J.1    Meijer, G.J.2    Bronkhorst, E.M.3    Jansen, J.A.4
  • 7
    • 0036132309 scopus 로고    scopus 로고
    • The ultrastructure of anorganic bovine bone and selected synthetic hydroxyapatites used as bone graft substitute materials
    • Benezra Rosen V, Hobbs LW, Spector M. The ultrastructure of anorganic bovine bone and selected synthetic hydroxyapatites used as bone graft substitute materials. Biomaterials 2002; 23:921-928.
    • (2002) Biomaterials , vol.23 , pp. 921-928
    • Benezra Rosen, V.1    Hobbs, L.W.2    Spector, M.3
  • 8
    • 1442327413 scopus 로고    scopus 로고
    • Effect of maxillary sinus augmentation on the survival of endosseous dental implants. A systematic review
    • Wallace SS, Froum SJ. Effect of maxillary sinus augmentation on the survival of endosseous dental implants. A systematic review. Ann Periodontol 2003; 8:328-343.
    • (2003) Ann Periodontol , vol.8 , pp. 328-343
    • Wallace, S.S.1    Froum, S.J.2
  • 9
    • 34548094603 scopus 로고    scopus 로고
    • Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites
    • Degidi M, Daprile G, Piattelli A, Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites. Clin Implant Dent Relat Res 2007; 9:144-149.
    • (2007) Clin Implant Dent Relat Res , vol.9 , pp. 144-149
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3    Carinci, F.4
  • 10
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008; 47:51-66.
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 11
    • 80052665756 scopus 로고    scopus 로고
    • Sinus bone formation and implant survival after sinus membrane elevation and implant placement: a 1- to 6-year follow-up study
    • Cricchio G, Sennerby L, Lundgren S. Sinus bone formation and implant survival after sinus membrane elevation and implant placement: a 1- to 6-year follow-up study. Clin Oral Implants Res 2011; 22:1200-1212.
    • (2011) Clin Oral Implants Res , vol.22 , pp. 1200-1212
    • Cricchio, G.1    Sennerby, L.2    Lundgren, S.3
  • 12
    • 84555204375 scopus 로고    scopus 로고
    • Resonance frequency analysis as a reliable criterion for early loading of sandblasted/acid-etched active surface implants placed by the osteotome sinus floor elevation technique
    • Markovic A, Colic S, Drazic R, Gacic B, Todorovic A, Stajcic Z. Resonance frequency analysis as a reliable criterion for early loading of sandblasted/acid-etched active surface implants placed by the osteotome sinus floor elevation technique. Int J Oral Maxillofac Implants 2011; 26:718-724.
    • (2011) Int J Oral Maxillofac Implants , vol.26 , pp. 718-724
    • Markovic, A.1    Colic, S.2    Drazic, R.3    Gacic, B.4    Todorovic, A.5    Stajcic, Z.6
  • 15
    • 4644230057 scopus 로고    scopus 로고
    • Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants
    • Glauser R, Sennerby L, Meredith N, etal. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004; 15:428-434.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 428-434
    • Glauser, R.1    Sennerby, L.2    Meredith, N.3
  • 16
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996; 7:261-267.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 17
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997; 8:226-233.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 20
    • 33847792960 scopus 로고    scopus 로고
    • Which hard tissue augmentation techniques are the most successful in furnishing bony support for implant placement?
    • Review. Erratum in: Int J Oral Maxillofac Implants 2008; 23:56.
    • Aghaloo TL, Moy PK. Which hard tissue augmentation techniques are the most successful in furnishing bony support for implant placement? Int J Oral Maxillofac Implants 2007; 22 (Suppl):49-70. Review. Erratum in: Int J Oral Maxillofac Implants 2008; 23:56.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , Issue.SUPPL. , pp. 49-70
    • Aghaloo, T.L.1    Moy, P.K.2
  • 21
    • 11844280921 scopus 로고    scopus 로고
    • Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading
    • Sjöström M, Lundgren S, Nilson H, Sennerby L. Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading. Int J Oral Maxillofac Surg 2005; 34:45-51.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 45-51
    • Sjöström, M.1    Lundgren, S.2    Nilson, H.3    Sennerby, L.4
  • 23
    • 84859423941 scopus 로고    scopus 로고
    • Bone density: a key determinant for treatment planning
    • In: Misch CE, ed.. 3rd ed. St. Louis, MO: Mosby Publishing Inc.
    • Misch CE. Bone density: a key determinant for treatment planning. In: Misch CE, ed. Contemporary implant dentistry. 3rd ed. St. Louis, MO: Mosby Publishing Inc., 2008:135.
    • (2008) Contemporary implant dentistry , pp. 135
    • Misch, C.E.1
  • 24
    • 0033073260 scopus 로고    scopus 로고
    • Bone classification: clinical-histomorphometric comparison
    • Trisi P, Rao W. Bone classification: clinical-histomorphometric comparison. Clin Oral Implants Res 1999; 10:1-7.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 1-7
    • Trisi, P.1    Rao, W.2
  • 26
    • 14644406863 scopus 로고    scopus 로고
    • A 3-year prospective follow-up study of implant-supported fixed prostheses in patients subjected to, maxillary sinus floor augmentation with a 80:20 mixture of deproteinized bovine bone and autogenous bone Clinical, radiographic and resonance frequency analysis
    • Hallman M, Sennerby L, Zetterqvist L, Lundgren S. A 3-year prospective follow-up study of implant-supported fixed prostheses in patients subjected to, maxillary sinus floor augmentation with a 80:20 mixture of deproteinized bovine bone and autogenous bone Clinical, radiographic and resonance frequency analysis. Int J Oral Maxillofac Surg 2005; 34:273-280.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 273-280
    • Hallman, M.1    Sennerby, L.2    Zetterqvist, L.3    Lundgren, S.4
  • 27
    • 68949127096 scopus 로고    scopus 로고
    • RFA values of implants placed in sinus grafted and nongrafted sites after 6 and 12 months
    • Degidi M, Daprile G, Piattelli A. RFA values of implants placed in sinus grafted and nongrafted sites after 6 and 12 months. Clin Implant Dent Relat Res 2009; 11:178-182.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 178-182
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3
  • 28
    • 20744449273 scopus 로고    scopus 로고
    • Immediate/early function of Brånemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study
    • Vanden Bogaerde L, Rangert B, Wendelhag I. Immediate/early function of Brånemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study. Clin Implant Dent Relat Res 2005; 7:S121-S130.
    • (2005) Clin Implant Dent Relat Res , vol.7
    • Vanden Bogaerde, L.1    Rangert, B.2    Wendelhag, I.3
  • 29
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 30
    • 0032086907 scopus 로고    scopus 로고
    • Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia
    • Rasmusson L, Meredith N, Kahnberg KE, Sennerby L. Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia. Int J Oral Maxillofac Surg 1998; 27:229-235.
    • (1998) Int J Oral Maxillofac Surg , vol.27 , pp. 229-235
    • Rasmusson, L.1    Meredith, N.2    Kahnberg, K.E.3    Sennerby, L.4
  • 31
    • 0023460152 scopus 로고
    • Maxillary sinus augmentation for endosteal implants: organized alternative treatment plans
    • Misch CE. Maxillary sinus augmentation for endosteal implants: organized alternative treatment plans. Int J Oral Implantol 1987; 4:49-58.
    • (1987) Int J Oral Implantol , vol.4 , pp. 49-58
    • Misch, C.E.1
  • 34
    • 41649098563 scopus 로고    scopus 로고
    • Correlation between implant stability quotient (ISQ) with clinical and histological aspects of dental implants removed for mobility
    • Scarano A, Carinci F, Quaranta A, Iezzi G, Piattelli M, Piattelli A. Correlation between implant stability quotient (ISQ) with clinical and histological aspects of dental implants removed for mobility. Int J Immunopathol Pharmacol 2007; 20:33-36.
    • (2007) Int J Immunopathol Pharmacol , vol.20 , pp. 33-36
    • Scarano, A.1    Carinci, F.2    Quaranta, A.3    Iezzi, G.4    Piattelli, M.5    Piattelli, A.6
  • 35
    • 34547700240 scopus 로고    scopus 로고
    • Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    • Rabel A, Köhler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 2007; 11:257-265.
    • (2007) Clin Oral Investig , vol.11 , pp. 257-265
    • Rabel, A.1    Köhler, S.G.2    Schmidt-Westhausen, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.