메뉴 건너뛰기




Volumn 19, Issue 6, 2012, Pages 1135-1145

Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation

Author keywords

coronary artery disease; myocardial perfusion imaging; normal relative perfusion; PET CT; quantification

Indexed keywords

RUBIDIUM 82; DIAGNOSTIC AGENT; RADIOPHARMACEUTICAL AGENT; RUBIDIUM;

EID: 84879187567     PISSN: 10713581     EISSN: 15326551     Source Type: Journal    
DOI: 10.1007/s12350-012-9621-y     Document Type: Article
Times cited : (34)

References (32)
  • 1
    • 32044472882 scopus 로고    scopus 로고
    • Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    • 16464714 10.1016/j.nuclcard.2005.12.004
    • Bateman TM, Heller GV, McGhie AI, Friedman JD, Case JA, Bryngelson JR, et al. Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT. J Nucl Cardiol 2006;13:24-33.
    • (2006) J Nucl Cardiol , vol.13 , pp. 24-33
    • Bateman, T.M.1    Heller, G.V.2    McGhie, A.I.3    Friedman, J.D.4    Case, J.A.5    Bryngelson, J.R.6
  • 2
    • 34447297536 scopus 로고    scopus 로고
    • Quantitative (82)Rb PET/CT: Development and validation of myocardial perfusion database
    • 17574973 10.2967/jnumed.107.039750
    • Santana CA, Folks RD, Garcia EV, Verdes L, Sanyal R, Hainer J, et al. Quantitative (82)Rb PET/CT: Development and validation of myocardial perfusion database. J Nucl Med 2007;48:1122-8.
    • (2007) J Nucl Med , vol.48 , pp. 1122-1128
    • Santana, C.A.1    Folks, R.D.2    Garcia, E.V.3    Verdes, L.4    Sanyal, R.5    Hainer, J.6
  • 4
    • 33847410522 scopus 로고    scopus 로고
    • Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease
    • 17349884 10.1016/j.jacc.2006.12.015 1:CAS:528:DC%2BD2sXivVams7o%3D
    • Sampson UK, Dorbala S, Limaye A, Kwong R, Di Carli MF. Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease. J Am Coll Cardiol 2007;49:1052-8.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 1052-1058
    • Sampson, U.K.1    Dorbala, S.2    Limaye, A.3    Kwong, R.4    Di Carli, M.F.5
  • 5
    • 0030711754 scopus 로고    scopus 로고
    • Incremental value of rubidium-82 positron emission tomography for prognostic assessment of known or suspected coronary artery disease
    • 9381999 10.1016/S0002-9149(97)00537-7 1:STN:280:DyaK1c%2Fit1aqsg%3D%3D
    • Marwick TH, Shan K, Patel S, Go RT, Lauer MS. Incremental value of rubidium-82 positron emission tomography for prognostic assessment of known or suspected coronary artery disease. Am J Cardiol 1997;80:865-70.
    • (1997) Am J Cardiol , vol.80 , pp. 865-870
    • Marwick, T.H.1    Shan, K.2    Patel, S.3    Go, R.T.4    Lauer, M.S.5
  • 6
    • 84863467794 scopus 로고    scopus 로고
    • Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography
    • doi: 10.1007/s12350-011-9496-3
    • Nakazato R, Berman DS, Dey D, Le Meunier L, Hayes SW, Fermin JS, et al. Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography. J Nucl Cardiol 2011; doi: 10.1007/s12350-011-9496-3.
    • (2011) J Nucl Cardiol
    • Nakazato, R.1    Berman, D.S.2    Dey, D.3    Le Meunier, L.4    Hayes, S.W.5    Fermin, J.S.6
  • 9
    • 34249697435 scopus 로고    scopus 로고
    • Will 3-dimensional PET-CT enable routine quantification of myocardial blood flow?
    • 10.1016/j.nuclcard.2007.04.006
    • de Kemp RA, Yoshinaga K, Beanlands RS. Will 3-dimensional PET-CT enable routine quantification of myocardial blood flow? J Nucl Cardiol 2007;14:380-97.
    • (2007) J Nucl Cardiol , vol.14 , pp. 380-397
    • De Kemp, R.A.1    Yoshinaga, K.2    Beanlands, R.S.3
  • 10
    • 0025293511 scopus 로고
    • Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: A multicenter trial
    • 2194003
    • Van Train KF, Maddahi J, Berman DS, Kiat H, Areeda J, Prigent F, et al. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: A multicenter trial. J Nucl Med 1990;31:1168-79.
    • (1990) J Nucl Med , vol.31 , pp. 1168-1179
    • Van Train, K.F.1    Maddahi, J.2    Berman, D.S.3    Kiat, H.4    Areeda, J.5    Prigent, F.6
  • 11
    • 0027234155 scopus 로고
    • Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: Definition and validation of stress normal limits and criteria for abnormality
    • 8355069
    • Van Train KF, Areeda J, Garcia EV, Cooke DC, Maddahi J, Kiat H, et al. Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: Definition and validation of stress normal limits and criteria for abnormality. J Nucl Med 1993;34:1494-502.
    • (1993) J Nucl Med , vol.34 , pp. 1494-1502
    • Van Train, K.F.1    Areeda, J.2    Garcia, E.V.3    Cooke, D.C.4    Maddahi, J.5    Kiat, H.6
  • 12
    • 0028269283 scopus 로고
    • Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms
    • 8151383
    • Van Train KF, Garcia EV, Maddahi J, Areeda J, Cooke C, Kiat HS, et al. Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. J Nucl Med 1994;35:609-18.
    • (1994) J Nucl Med , vol.35 , pp. 609-618
    • Van Train, K.F.1    Garcia, E.V.2    Maddahi, J.3    Areeda, J.4    Cooke, C.5    Kiat, H.S.6
  • 13
    • 4344684086 scopus 로고    scopus 로고
    • Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease
    • 15295413 10.1016/j.nuclcard.2004.04.005 1:STN:280:DC%2BD2czptFansg%3D%3D
    • Parkash R, de Kemp RA, Ruddy TD, Kitsikis A, Hart R, Beauchesne L, et al. Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol 2004;11:440-9.
    • (2004) J Nucl Cardiol , vol.11 , pp. 440-449
    • Parkash, R.1    De Kemp, R.A.2    Ruddy, T.D.3    Kitsikis, A.4    Hart, R.5    Beauchesne, L.6
  • 14
    • 0032887678 scopus 로고    scopus 로고
    • Comparison of the Diamond-Forrester method and a new score to estimate the pretest probability of coronary disease before exercise testing
    • 10502221 10.1016/S0002-8703(99)70190-0 1:STN:280:DyaK1MvjtFGjsw%3D%3D
    • Morise AP. Comparison of the Diamond-Forrester method and a new score to estimate the pretest probability of coronary disease before exercise testing. Am Heart J 1999;138:740-5.
    • (1999) Am Heart J , vol.138 , pp. 740-745
    • Morise, A.P.1
  • 15
    • 0018750969 scopus 로고
    • Analysis of probability as an aid in the clinical diagnosis of coronary artery disease
    • 440357 10.1056/NEJM197906143002402 1:STN:280:DyaE1M7nvVCrtg%3D%3D
    • Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 1979;300:1350-8.
    • (1979) N Engl J Med , vol.300 , pp. 1350-1358
    • Diamond, G.A.1    Forrester, J.S.2
  • 16
    • 79961174089 scopus 로고    scopus 로고
    • Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for ischemia
    • 21816311 10.1016/j.jacc.2011.01.065
    • Ziadi MC, de Kemp RA, Williams KA, Guo A, Chow BJ, Renaud JM, et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for ischemia. J Am Coll Cardiol 2011;58:740-8.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 740-748
    • Ziadi, M.C.1    De Kemp, R.A.2    Williams, K.A.3    Guo, A.4    Chow, B.J.5    Renaud, J.M.6
  • 17
    • 34047252834 scopus 로고    scopus 로고
    • 82Rb generator for cardiac perfusion imaging with positron emission tomography
    • 17228112 10.1088/0031-9155/52/3/009 1:STN:280:DC%2BD2s%2FjtVyktg%3D%3D
    • 82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol 2007;52:659-73.
    • (2007) Phys Med Biol , vol.52 , pp. 659-673
    • Klein, R.1    Adler, A.2    Beanlands, R.S.3    De Kemp, R.A.4
  • 18
    • 77956539101 scopus 로고    scopus 로고
    • Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program
    • 20387135 10.1007/s12350-010-9225-3
    • Klein R, Renaud JM, Ziadi MC, Thorn SL, Adler A, Beanlands RS, et al. Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program. J Nucl Cardiol 2010;17:600-16.
    • (2010) J Nucl Cardiol , vol.17 , pp. 600-616
    • Klein, R.1    Renaud, J.M.2    Ziadi, M.C.3    Thorn, S.L.4    Adler, A.5    Beanlands, R.S.6
  • 19
    • 77956682137 scopus 로고    scopus 로고
    • ASNC imaging guidelines for nuclear cardiology procedures: PET myocardial perfusion and metabolism clinical imaging
    • 10.1007/s12350-009-9094-9
    • Dilsizian V, Bacharach SL, Beanlands RS, Bergmann SR, Delbeke D, Gropler RJ. ASNC imaging guidelines for nuclear cardiology procedures: PET myocardial perfusion and metabolism clinical imaging. J Nucl Cardiol 2009;16:651-81.
    • (2009) J Nucl Cardiol , vol.16 , pp. 651-681
    • Dilsizian, V.1    Bacharach, S.L.2    Beanlands, R.S.3    Bergmann, S.R.4    Delbeke, D.5    Gropler, R.J.6
  • 20
    • 34547429592 scopus 로고    scopus 로고
    • Corridor4DM: The Michigan method for quantitative nuclear cardiology
    • 17679053 10.1016/j.nuclcard.2007.06.006
    • Ficaro EP, Lee BC, Kritzman JN, Corbett JR. Corridor4DM: The Michigan method for quantitative nuclear cardiology. J Nucl Cardiol 2007;14:455-65.
    • (2007) J Nucl Cardiol , vol.14 , pp. 455-465
    • Ficaro, E.P.1    Lee, B.C.2    Kritzman, J.N.3    Corbett, J.R.4
  • 21
    • 0029979052 scopus 로고    scopus 로고
    • Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT
    • 8636545 10.1016/0735-1097(96)00052-6 1:STN:280:DyaK283itFygtw%3D%3D
    • Mazzanti M, Germano G, Kiat H, Kavanagh PB, Alexanderson E, Friedman JD, et al. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996;27:1612-20.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1612-1620
    • Mazzanti, M.1    Germano, G.2    Kiat, H.3    Kavanagh, P.B.4    Alexanderson, E.5    Friedman, J.D.6
  • 22
    • 73449146265 scopus 로고    scopus 로고
    • Prognostic implications of myocardial perfusion single photon emission computed tomography in the elderly
    • 10.1161/CIRCULATIONAHA.109.192694
    • Hachamovitch R, Kang X, Amanullah AM, et al. Prognostic implications of myocardial perfusion single photon emission computed tomography in the elderly. Circulation 2009;120:2163-5.
    • (2009) Circulation , vol.120 , pp. 2163-2165
    • Hachamovitch, R.1    Kang, X.2    Amanullah, A.M.3
  • 23
    • 67649385766 scopus 로고    scopus 로고
    • 13N-ammonia myocardial perfusion PET: Added value of coronary flow reserve
    • 19573732 10.1016/j.jacc.2009.02.069
    • 13N-ammonia myocardial perfusion PET: Added value of coronary flow reserve. J Am Coll Cardiol 2009;54:150-6.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 150-156
    • Herzog, B.A.1    Husmann, L.2    Kaufmann, P.A.3
  • 24
    • 0037192118 scopus 로고    scopus 로고
    • Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    • 10.1161/hc0402.102975
    • Cerquiera MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-42.
    • (2002) Circulation , vol.105 , pp. 539-542
    • Cerquiera, M.D.1    Weissman, N.J.2    Dilsizian, V.3    Jacobs, A.K.4    Kaul, S.5    Laskey, W.K.6
  • 25
    • 84880057290 scopus 로고    scopus 로고
    • ROC analysis: Web-based calculator for ROC curves
    • Updated 2006 May 17; cited 17 Jan 2012
    • Eng J. ROC analysis: Web-based calculator for ROC curves. Baltimore: Johns Hopkins University. Updated 2006 May 17; cited 17 Jan 2012. http://www.jrocfit.org.
    • Baltimore: Johns Hopkins University
    • Eng, J.1
  • 26
    • 3142749673 scopus 로고    scopus 로고
    • ACC/AHA/ASNC Guidelines for the clinical use of cardiac radionuclide imaging - Executive summary
    • 14522503 10.1016/j.jacc.2003.08.011
    • Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC Guidelines for the clinical use of cardiac radionuclide imaging - Executive summary. J Am Coll Cardiol 2003;42:1318-33.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1318-1333
    • Klocke, F.J.1    Baird, M.G.2    Lorell, B.H.3    Bateman, T.M.4    Messer, J.V.5    Berman, D.S.6
  • 27
    • 80054895116 scopus 로고    scopus 로고
    • Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET
    • 21873801 10.1253/circj.CJ-11-0502
    • Yoshinaga K, Katoh C, Manabe O, Klein R, Naya M, Sakakibara M, et al. Incremental diagnostic value of regional myocardial blood flow quantification over relative perfusion imaging with generator-produced rubidium-82 PET. Circ J 2011;75:2628-34.
    • (2011) Circ J , vol.75 , pp. 2628-2634
    • Yoshinaga, K.1    Katoh, C.2    Manabe, O.3    Klein, R.4    Naya, M.5    Sakakibara, M.6
  • 28
    • 84865094762 scopus 로고    scopus 로고
    • Does quantification of myocardial flow reserve using Rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease?
    • doi: 10. 1007/s12350-011-9506-5
    • Ziadi MC, deKemp RA, Williams K, Guo A, Renaud JM, Chow BJ, et al. Does quantification of myocardial flow reserve using Rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol 2012; doi: 10.1007/s12350-011-9506-5.
    • (2012) J Nucl Cardiol
    • Ziadi, M.C.1    Dekemp, R.A.2    Williams, K.3    Guo, A.4    Renaud, J.M.5    Chow, B.J.6
  • 30
    • 34247208691 scopus 로고    scopus 로고
    • Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study
    • 17332611
    • Dorbala S, Vanagala D, Sampson U, Limaye A, Kwong R, Di Carli MF. Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: A 82Rb PET/CT study. J Nucl Med 2007;48:349-58.
    • (2007) J Nucl Med , vol.48 , pp. 349-358
    • Dorbala, S.1    Vanagala, D.2    Sampson, U.3    Limaye, A.4    Kwong, R.5    Di Carli, M.F.6
  • 31
    • 67650727178 scopus 로고    scopus 로고
    • Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection
    • 19420417 10.1088/0031-9155/54/10/013
    • Tang J, Rahmim A, Lautamaki R, Lodge MA, Bengel FM, Tsui BMW. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection. Phys Med Biol 2009;54:3161-71.
    • (2009) Phys Med Biol , vol.54 , pp. 3161-3171
    • Tang, J.1    Rahmim, A.2    Lautamaki, R.3    Lodge, M.A.4    Bengel, F.M.5    Tsui, B.M.W.6
  • 32
    • 0020507033 scopus 로고
    • The declining specificity of exercise radionuclide ventriculography
    • 6877322 10.1056/NEJM198309013090902 1:STN:280:DyaL3s3ntFeksg%3D%3D
    • Rozanski A, Diamond GA, Berman D, Forrester JS, Morris D, Swan HJ. The declining specificity of exercise radionuclide ventriculography. N Engl J Med 1983;309:518-22.
    • (1983) N Engl J Med , vol.309 , pp. 518-522
    • Rozanski, A.1    Diamond, G.A.2    Berman, D.3    Forrester, J.S.4    Morris, D.5    Swan, H.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.