메뉴 건너뛰기




Volumn 423, Issue , 2013, Pages 99-104

Hepcidin-25: Measurement by LC-MS/MS in serum and urine, reference ranges and urinary fractional excretion

Author keywords

Chromatography; Hepcidin; Iron disorders; Mass spectrometry; Reference values; Renal behavior

Indexed keywords

FERRITIN; HEPCIDIN; HEPCIDIN 25; IRON; UNCLASSIFIED DRUG;

EID: 84878208989     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2013.04.021     Document Type: Article
Times cited : (36)

References (31)
  • 1
    • 10844258104 scopus 로고    scopus 로고
    • Hepcidin regulates cellular iron efflux by binding to ferroportin and inducing its internalization
    • Nemeth E., Tuttle M.S., Powelson J., et al. Hepcidin regulates cellular iron efflux by binding to ferroportin and inducing its internalization. Science 2004, 306:2090-2093.
    • (2004) Science , vol.306 , pp. 2090-2093
    • Nemeth, E.1    Tuttle, M.S.2    Powelson, J.3
  • 2
    • 50549094991 scopus 로고    scopus 로고
    • Advances in quantitative hepcidin measurements by time-of-flight mass spectrometry
    • Swinkels D.W., Girelli D., Laarakkers C., et al. Advances in quantitative hepcidin measurements by time-of-flight mass spectrometry. PLoS One 2008, 3:e2706.
    • (2008) PLoS One , vol.3
    • Swinkels, D.W.1    Girelli, D.2    Laarakkers, C.3
  • 4
    • 33745743014 scopus 로고    scopus 로고
    • Hepcidin and iron-loading anemias
    • Nemeth E., Ganz T. Hepcidin and iron-loading anemias. Haematologica 2006, 91:727-732.
    • (2006) Haematologica , vol.91 , pp. 727-732
    • Nemeth, E.1    Ganz, T.2
  • 5
    • 42649118442 scopus 로고    scopus 로고
    • Mutations in TMPRSS6 cause iron-refractory iron deficiency anemia (IRIDA)
    • Finberg K.E., Heeney M.M., Campagna D.R., et al. Mutations in TMPRSS6 cause iron-refractory iron deficiency anemia (IRIDA). Nat Genet 2008, 40:569-571.
    • (2008) Nat Genet , vol.40 , pp. 569-571
    • Finberg, K.E.1    Heeney, M.M.2    Campagna, D.R.3
  • 6
    • 77955957335 scopus 로고    scopus 로고
    • Hepcidin-25 is a marker of the response rather than resistance to exogenous erythropoietin in chronic kidney disease/chronic heart failure patients
    • Van der Putten K., Jie K.E., van den Broek D., et al. Hepcidin-25 is a marker of the response rather than resistance to exogenous erythropoietin in chronic kidney disease/chronic heart failure patients. Eur J Heart Fail 2010, 12:943-950.
    • (2010) Eur J Heart Fail , vol.12 , pp. 943-950
    • Van der Putten, K.1    Jie, K.E.2    van den Broek, D.3
  • 8
    • 0037020241 scopus 로고    scopus 로고
    • The solution structure of human hepcidin, a peptide hormone with antimicrobial activity that is involved in iron uptake and hereditary hemochromatosis
    • Hunter H.N., Fulton D.B., Ganz T., Vogel H.J. The solution structure of human hepcidin, a peptide hormone with antimicrobial activity that is involved in iron uptake and hereditary hemochromatosis. J Biol Chem 2002, 277:37597-37603.
    • (2002) J Biol Chem , vol.277 , pp. 37597-37603
    • Hunter, H.N.1    Fulton, D.B.2    Ganz, T.3    Vogel, H.J.4
  • 9
    • 82755195789 scopus 로고    scopus 로고
    • Hepcidin in human iron disorders: diagnostic implications
    • Kroot J.J., Tjalsma H., Fleming R.E., Swinkels D.W. Hepcidin in human iron disorders: diagnostic implications. Clin Chem 2011, 57:1650-1669.
    • (2011) Clin Chem , vol.57 , pp. 1650-1669
    • Kroot, J.J.1    Tjalsma, H.2    Fleming, R.E.3    Swinkels, D.W.4
  • 10
  • 11
    • 66149182892 scopus 로고    scopus 로고
    • Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    • Bansal S.S., Halket J.M., Fusova J., et al. Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Rapid Commun Mass Spectrom 2009, 23:1531-1542.
    • (2009) Rapid Commun Mass Spectrom , vol.23 , pp. 1531-1542
    • Bansal, S.S.1    Halket, J.M.2    Fusova, J.3
  • 12
    • 37649012006 scopus 로고    scopus 로고
    • Simple and sensitive quantification of bioactive peptides in biological matrices using liquid chromatography/selected reaction monitoring mass spectrometry coupled with trichloroacetic acid clean-up
    • Murao N., Ishigai M., Yasuno H., Shimonaka Y., Aso Y. Simple and sensitive quantification of bioactive peptides in biological matrices using liquid chromatography/selected reaction monitoring mass spectrometry coupled with trichloroacetic acid clean-up. Rapid Commun Mass Spectrom 2007, 21:4033-4038.
    • (2007) Rapid Commun Mass Spectrom , vol.21 , pp. 4033-4038
    • Murao, N.1    Ishigai, M.2    Yasuno, H.3    Shimonaka, Y.4    Aso, Y.5
  • 13
    • 34547940326 scopus 로고    scopus 로고
    • Quantitation of hepcidin from human and mouse serum using liquid chromatography tandem mass spectrometry
    • Murphy A.T., Witcher D.R., Luan P., Wroblewski V.J. Quantitation of hepcidin from human and mouse serum using liquid chromatography tandem mass spectrometry. Blood 2007, 110:1048-1054.
    • (2007) Blood , vol.110 , pp. 1048-1054
    • Murphy, A.T.1    Witcher, D.R.2    Luan, P.3    Wroblewski, V.J.4
  • 14
    • 51349114252 scopus 로고    scopus 로고
    • Quantification of hepcidin-25 in human serum by isotope dilution micro-HPLC-tandem mass spectrometry
    • Kobold U., Dülffer T., Dangl M., et al. Quantification of hepcidin-25 in human serum by isotope dilution micro-HPLC-tandem mass spectrometry. Clin Chem 2008, 54:1584-1586.
    • (2008) Clin Chem , vol.54 , pp. 1584-1586
    • Kobold, U.1    Dülffer, T.2    Dangl, M.3
  • 15
    • 56749180737 scopus 로고    scopus 로고
    • Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry
    • Bansal S.S., Halket J.M., Bomford A., et al. Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry. Anal Biochem 2009, 384:245-253.
    • (2009) Anal Biochem , vol.384 , pp. 245-253
    • Bansal, S.S.1    Halket, J.M.2    Bomford, A.3
  • 16
    • 77951260949 scopus 로고    scopus 로고
    • Quantitation of hepcidin in serum using ultra-high-pressure liquid chromatography and a linear ion trap mass spectrometer
    • Bansal S.S., Abbate V., Bomford A., et al. Quantitation of hepcidin in serum using ultra-high-pressure liquid chromatography and a linear ion trap mass spectrometer. Rapid Commun Mass Spectrom 2010, 24:1251-1259.
    • (2010) Rapid Commun Mass Spectrom , vol.24 , pp. 1251-1259
    • Bansal, S.S.1    Abbate, V.2    Bomford, A.3
  • 17
    • 80053627200 scopus 로고    scopus 로고
    • Effects of a single dose of oral iron on hepcidin concentrations in human urine and serum analyzed by a robust LC-MS/MS method
    • Hwang S.I., Lee Y.Y., Park J.O., et al. Effects of a single dose of oral iron on hepcidin concentrations in human urine and serum analyzed by a robust LC-MS/MS method. Clin Chim Acta 2011, 412:2241-2247.
    • (2011) Clin Chim Acta , vol.412 , pp. 2241-2247
    • Hwang, S.I.1    Lee, Y.Y.2    Park, J.O.3
  • 18
    • 67349229546 scopus 로고    scopus 로고
    • Development of a method for the sensitive and quantitative determination of hepcidin in human serum using LC-MS/MS
    • Li H., Rose M.J., Tran L., et al. Development of a method for the sensitive and quantitative determination of hepcidin in human serum using LC-MS/MS. J Pharmacol Toxicol Methods 2009, 59:171-180.
    • (2009) J Pharmacol Toxicol Methods , vol.59 , pp. 171-180
    • Li, H.1    Rose, M.J.2    Tran, L.3
  • 19
    • 81855198995 scopus 로고    scopus 로고
    • Development of a nano-liquid chromatography on chip tandem mass spectrometry method for high-sensitivity hepcidin quantitation
    • Houbart V., Cobraiville G., Lecomte F., Debrus B., Hubert P., Fillet M. Development of a nano-liquid chromatography on chip tandem mass spectrometry method for high-sensitivity hepcidin quantitation. J Chromatogr A 2011, 1218:9046-9054.
    • (2011) J Chromatogr A , vol.1218 , pp. 9046-9054
    • Houbart, V.1    Cobraiville, G.2    Lecomte, F.3    Debrus, B.4    Hubert, P.5    Fillet, M.6
  • 20
    • 84857656638 scopus 로고    scopus 로고
    • Preanalytical factors and reference intervals for serum hepcidin LC-MS/MS method
    • Itkonen O., Parkkinen J., Stenman U.H., Hämäläinen E. Preanalytical factors and reference intervals for serum hepcidin LC-MS/MS method. Clin Chim Acta 2012, 413:696-701.
    • (2012) Clin Chim Acta , vol.413 , pp. 696-701
    • Itkonen, O.1    Parkkinen, J.2    Stenman, U.H.3    Hämäläinen, E.4
  • 21
    • 73149122764 scopus 로고    scopus 로고
    • Results of the first international round robin for the quantification of urinary and plasma hepcidin assays: need for standardization
    • Kroot J.J., Kemna E.H., Bansal S.S., et al. Results of the first international round robin for the quantification of urinary and plasma hepcidin assays: need for standardization. Haematologica 2009, 94:1748-1782.
    • (2009) Haematologica , vol.94 , pp. 1748-1782
    • Kroot, J.J.1    Kemna, E.H.2    Bansal, S.S.3
  • 22
    • 7444240202 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part I
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part I. J Pharm Biomed Anal 2004, 36:579-586.
    • (2004) J Pharm Biomed Anal , vol.36 , pp. 579-586
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 23
    • 34548525400 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part II
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part II. J Pharm Biomed Anal 2007, 45:70-81.
    • (2007) J Pharm Biomed Anal , vol.45 , pp. 70-81
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 24
    • 34548525400 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part III
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures. A SFSTP proposal-part III. J Pharm Biomed Anal 2007, 45:82-96.
    • (2007) J Pharm Biomed Anal , vol.45 , pp. 82-96
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 25
    • 53249091927 scopus 로고    scopus 로고
    • Harmonization of strategies for the validation of quantitative analytical procedures: a SFSTP proposal part IV
    • Hubert P., Nguyen-Huu J.J., Boulanger B., et al. Harmonization of strategies for the validation of quantitative analytical procedures: a SFSTP proposal part IV. J Pharm Biomed Anal 2008, 48:760-771.
    • (2008) J Pharm Biomed Anal , vol.48 , pp. 760-771
    • Hubert, P.1    Nguyen-Huu, J.J.2    Boulanger, B.3
  • 26
    • 34548550429 scopus 로고    scopus 로고
    • Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays
    • Viswanathan C.T., Bansal S., Booth B., et al. Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays. Pharm Res 2007, 24:1962-1973.
    • (2007) Pharm Res , vol.24 , pp. 1962-1973
    • Viswanathan, C.T.1    Bansal, S.2    Booth, B.3
  • 27
    • 65649142017 scopus 로고    scopus 로고
    • CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration). A new equation to estimate glomerular filtration rate
    • Levey A.S., Stevens L.A., Schmid C.H., et al. CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration). A new equation to estimate glomerular filtration rate. Ann Intern Med 2009, 150:604-612.
    • (2009) Ann Intern Med , vol.150 , pp. 604-612
    • Levey, A.S.1    Stevens, L.A.2    Schmid, C.H.3
  • 28
    • 0031972806 scopus 로고    scopus 로고
    • Clinical utility of the soluble transferrin receptor and comparison with serum ferritin in several populations
    • Mast A.E., Blinder M.A., Gronowski A.M., Chumley C., Scott M.G. Clinical utility of the soluble transferrin receptor and comparison with serum ferritin in several populations. Clin Chem 1998, 44:45-51.
    • (1998) Clin Chem , vol.44 , pp. 45-51
    • Mast, A.E.1    Blinder, M.A.2    Gronowski, A.M.3    Chumley, C.4    Scott, M.G.5
  • 30
    • 67349113791 scopus 로고    scopus 로고
    • (Pre)analytical imprecision, between-subject variability, and daily variations in serum and urine hepcidin: implications for clinical studies
    • Kroot J.J., Hendriks J.C., Laarakkers C.M., et al. (Pre)analytical imprecision, between-subject variability, and daily variations in serum and urine hepcidin: implications for clinical studies. Anal Biochem 2009, 389:124-129.
    • (2009) Anal Biochem , vol.389 , pp. 124-129
    • Kroot, J.J.1    Hendriks, J.C.2    Laarakkers, C.M.3
  • 31
    • 79959517566 scopus 로고    scopus 로고
    • Serum hepcidin: reference ranges and biochemical correlates in the general population
    • Galesloot T.E., Vermeulen S.H., Geurts-Moespot A.J., et al. Serum hepcidin: reference ranges and biochemical correlates in the general population. Blood 2011, 117:218-225.
    • (2011) Blood , vol.117 , pp. 218-225
    • Galesloot, T.E.1    Vermeulen, S.H.2    Geurts-Moespot, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.