메뉴 건너뛰기




Volumn 27, Issue 5, 2013, Pages 1681-1688

Toward increased autonomy in the surgical OR: Needs, requests, and expectations

Author keywords

Minimally invasive surgery; Operating room; Robotic systems; Structured knowledge; Surgical autonomy

Indexed keywords

ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL PRACTICE; INTRAOPERATIVE PERIOD; LAPAROSCOPIC SURGERY; MEDICAL DECISION MAKING; MEDICAL DOCUMENTATION; MEDICAL RECORD; OPERATING ROOM; OPERATION DURATION; PERIOPERATIVE PERIOD; PRIORITY JOURNAL; ROBOTIC SURGICAL SYSTEM; ROBOTICS; SURGEON; SURGICAL TECHNIQUE; WORKFLOW; WORKLOAD;

EID: 84876296728     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-012-2656-y     Document Type: Article
Times cited : (42)

References (40)
  • 1
    • 39149132118 scopus 로고    scopus 로고
    • A consensus document on robotic surgery
    • 18163170 10.1007/s00464-007-9727-5 1:STN:280:DC%2BD1c%2FpvFKmtA%3D%3D
    • Herron DM, Marohn M (2008) A consensus document on robotic surgery. Surg Endosc 22:313-325
    • (2008) Surg Endosc , vol.22 , pp. 313-325
    • Herron, D.M.1    Marohn, M.2
  • 2
    • 81955160799 scopus 로고    scopus 로고
    • Evolution of autonomous and semi-autonomous robotic surgical systems: A review of the literature
    • 21815238 10.1002/rcs.408 1:STN:280:DC%2BC38%2Fht1Ojsw%3D%3D
    • Moustris GP, Hiridis SC, Deliparaschos KM, Konstantinidis KM (2011) Evolution of autonomous and semi-autonomous robotic surgical systems: a review of the literature. Int J Med Robot 7:375-392
    • (2011) Int J Med Robot , vol.7 , pp. 375-392
    • Moustris, G.P.1    Hiridis, S.C.2    Deliparaschos, K.M.3    Konstantinidis, K.M.4
  • 3
    • 79960416659 scopus 로고    scopus 로고
    • Automation of a suturing device for minimally invasive surgery
    • 21298543 10.1007/s00464-010-1532-x
    • Gopel T, Hartl F, Schneider A, Buss M, Feussner H (2011) Automation of a suturing device for minimally invasive surgery. Surg Endosc 25:2100-2104
    • (2011) Surg Endosc , vol.25 , pp. 2100-2104
    • Gopel, T.1    Hartl, F.2    Schneider, A.3    Buss, M.4    Feussner, H.5
  • 5
    • 79954422347 scopus 로고    scopus 로고
    • New technologies for information retrieval to achieve situational awareness and higher patient safety in the surgical operating room: The MRI institutional approach and review of the literature
    • 20721588 10.1007/s00464-010-1239-z
    • Kranzfelder M, Schneider A, Gillen S, Feussner H (2011) New technologies for information retrieval to achieve situational awareness and higher patient safety in the surgical operating room: the MRI institutional approach and review of the literature. Surg Endosc 25:696-705
    • (2011) Surg Endosc , vol.25 , pp. 696-705
    • Kranzfelder, M.1    Schneider, A.2    Gillen, S.3    Feussner, H.4
  • 7
    • 67849117226 scopus 로고    scopus 로고
    • The "eLITE" model: Construct validation of a new training system for natural orifice transluminal endoscopic surgery (NOTES)
    • 19418392 10.1055/s-0029-1214620 1:STN:280:DC%2BD1MzisVejtw%3D%3D
    • Gillen S, Wilhelm D, Meining A, Fiolka A, Doundoulakis E, Schneider A, von Delius S, Friess H, Feussner H (2009) The "ELITE" model: construct validation of a new training system for natural orifice transluminal endoscopic surgery (NOTES). Endoscopy 41:395-399
    • (2009) Endoscopy , vol.41 , pp. 395-399
    • Gillen, S.1    Wilhelm, D.2    Meining, A.3    Fiolka, A.4    Doundoulakis, E.5    Schneider, A.6    Von Delius, S.7    Friess, H.8    Feussner, H.9
  • 10
    • 3042810133 scopus 로고    scopus 로고
    • Camera and instrument holders and their clinical value in minimally invasive surgery
    • 15471021 10.1097/01.sle.0000129395.42501.5d
    • Jaspers JE, Breedveld P, Herder JL, Grimbergen CA (2004) Camera and instrument holders and their clinical value in minimally invasive surgery. Surg Laparosc Endosc Percutan Tech 14:145-152
    • (2004) Surg Laparosc Endosc Percutan Tech , vol.14 , pp. 145-152
    • Jaspers, J.E.1    Breedveld, P.2    Herder, J.L.3    Grimbergen, C.A.4
  • 11
    • 85027958142 scopus 로고    scopus 로고
    • Use of a mechatronic robotic camera holding system in head and neck surgery
    • 21509620 10.1007/s00106-011-2273-4 1:STN:280:DC%2BC3Mjhs1Srsg%3D%3D
    • Kristin J, Geiger R, Knapp FB, Schipper J, Klenzner T (2011) Use of a mechatronic robotic camera holding system in head and neck surgery. HNO 59:575-581
    • (2011) HNO , vol.59 , pp. 575-581
    • Kristin, J.1    Geiger, R.2    Knapp, F.B.3    Schipper, J.4    Klenzner, T.5
  • 14
    • 0032890837 scopus 로고    scopus 로고
    • Self-guided robotic camera control for laparoscopic surgery compared with human camera control
    • 10326852 10.1016/S0002-9610(99)00055-0 1:STN:280:DyaK1M3ls1Ortg%3D%3D
    • Omote K, Feussner H, Ungeheuer A, Arbter K, Wei GQ, Siewert JR, Hirzinger G (1999) Self-guided robotic camera control for laparoscopic surgery compared with human camera control. Am J Surg 177:321-324
    • (1999) Am J Surg , vol.177 , pp. 321-324
    • Omote, K.1    Feussner, H.2    Ungeheuer, A.3    Arbter, K.4    Wei, G.Q.5    Siewert, J.R.6    Hirzinger, G.7
  • 16
    • 63649096011 scopus 로고    scopus 로고
    • Upgrade of an optical navigation system with a permanent electromagnetic position control: A first step towards "navigated control" for liver surgery
    • 19183828 10.1007/s00534-008-0040-z
    • Beller S, Eulenstein S, Lange T, Hunerbein M, Schlag PM (2009) Upgrade of an optical navigation system with a permanent electromagnetic position control: a first step towards "navigated control" for liver surgery. J Hepatobiliary Pancreat Surg 16:165-170
    • (2009) J Hepatobiliary Pancreat Surg , vol.16 , pp. 165-170
    • Beller, S.1    Eulenstein, S.2    Lange, T.3    Hunerbein, M.4    Schlag, P.M.5
  • 18
    • 57649213766 scopus 로고    scopus 로고
    • Novel haptic tool and input device for real time bilateral biomanipulation addressing endoscopic surgery
    • 18001923
    • Houston K, Sieber A, Eder C, Tonet O, Menciassi A, Dario P (2007) Novel haptic tool and input device for real time bilateral biomanipulation addressing endoscopic surgery. Conf Proc IEEE Eng Med Biol Soc 2007:198-201
    • (2007) Conf Proc IEEE Eng Med Biol Soc , vol.2007 , pp. 198-201
    • Houston, K.1    Sieber, A.2    Eder, C.3    Tonet, O.4    Menciassi, A.5    Dario, P.6
  • 19
    • 79952081978 scopus 로고    scopus 로고
    • Development of a stereo vision measurement system for a 3D three-axial pneumatic parallel mechanism robot arm
    • 10.3390/s110202257
    • Chiang MH, Lin HT, Hou CL (2011) Development of a stereo vision measurement system for a 3D three-axial pneumatic parallel mechanism robot arm. Sensors (Basel) 11:2257-2281
    • (2011) Sensors (Basel) , vol.11 , pp. 2257-2281
    • Chiang, M.H.1    Lin, H.T.2    Hou, C.L.3
  • 20
    • 0345015474 scopus 로고    scopus 로고
    • A performance study comparing manual and robotically assisted laparoscopic surgery using the da Vinci system
    • 12874678 10.1007/s00464-002-9248-1 1:STN:280:DC%2BD3sngs1Ojuw%3D%3D
    • Hubens G, Coveliers H, Balliu L, Ruppert M, Vaneerdeweg W (2003) A performance study comparing manual and robotically assisted laparoscopic surgery using the Da Vinci system. Surg Endosc 17:1595-1599
    • (2003) Surg Endosc , vol.17 , pp. 1595-1599
    • Hubens, G.1    Coveliers, H.2    Balliu, L.3    Ruppert, M.4    Vaneerdeweg, W.5
  • 24
    • 77952319399 scopus 로고    scopus 로고
    • A comparison of laparoscopic and robotic assisted suturing performance by experts and novices
    • 20045162 10.1016/j.surg.2009.11.002
    • Chandra V, Nehra D, Parent R, Woo R, Reyes R, Hernandez-Boussard T, Dutta S (2010) A comparison of laparoscopic and robotic assisted suturing performance by experts and novices. Surgery 147:830-839
    • (2010) Surgery , vol.147 , pp. 830-839
    • Chandra, V.1    Nehra, D.2    Parent, R.3    Woo, R.4    Reyes, R.5    Hernandez-Boussard, T.6    Dutta, S.7
  • 26
    • 84876285329 scopus 로고    scopus 로고
    • Bowa Medical
    • Bowa Medical (2012) http://www.bowa-medical.com
    • (2012)
  • 27
    • 42749083183 scopus 로고    scopus 로고
    • Pre-operative ordering of minimally invasive surgical tools: A fuzzy inference system approach
    • 18378128 10.1016/j.artmed.2008.01.003
    • Miller DJ, Nelson CA, Oleynikov D, Jones DD (2008) Pre-operative ordering of minimally invasive surgical tools: a fuzzy inference system approach. Artif Intell Med 43:35-45
    • (2008) Artif Intell Med , vol.43 , pp. 35-45
    • Miller, D.J.1    Nelson, C.A.2    Oleynikov, D.3    Jones, D.D.4
  • 29
    • 84856698468 scopus 로고    scopus 로고
    • Current progress on augmented reality visualization in endoscopic surgery
    • 22249372 10.1097/MOU.0b013e3283501774
    • Nakamoto M, Ukimura O, Faber K, Gill IS (2012) Current progress on augmented reality visualization in endoscopic surgery. Curr Opin Urol 22:121-126
    • (2012) Curr Opin Urol , vol.22 , pp. 121-126
    • Nakamoto, M.1    Ukimura, O.2    Faber, K.3    Gill, I.S.4
  • 30
    • 80051872997 scopus 로고    scopus 로고
    • Augmented reality in laparoscopic surgical oncology
    • 21802281 10.1016/j.suronc.2011.07.002
    • Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20:189-201
    • (2011) Surg Oncol , vol.20 , pp. 189-201
    • Nicolau, S.1    Soler, L.2    Mutter, D.3    Marescaux, J.4
  • 32
    • 84861579188 scopus 로고    scopus 로고
    • Evaluation of a context sensitive system for intra-operative usage of the electronic patient record
    • 22006257 10.1055/s-0031-1285923 1:STN:280:DC%2BC38zmsFygsw%3D%3D
    • Dressler CR, Fischer M, Burgert O, Strauss G (2012) Evaluation of a context sensitive system for intra-operative usage of the electronic patient record. Laryngorhinootologie 91:368-374
    • (2012) Laryngorhinootologie , vol.91 , pp. 368-374
    • Dressler, C.R.1    Fischer, M.2    Burgert, O.3    Strauss, G.4
  • 33
    • 84868238548 scopus 로고    scopus 로고
    • You can't touch this: Touch-free navigation through radiological images
    • 22064490 10.1177/1553350611425508
    • Ebert LC, Hatch G, Ampanozi G, Thali MJ, Ross S (2012) You can't touch this: touch-free navigation through radiological images. Surg Innov 19:301-307
    • (2012) Surg Innov , vol.19 , pp. 301-307
    • Ebert, L.C.1    Hatch, G.2    Ampanozi, G.3    Thali, M.J.4    Ross, S.5
  • 35
    • 33748504383 scopus 로고    scopus 로고
    • The voice-controlled robotic assist scope holder AESOP for the endoscopic approach to the sella
    • 17268585 10.1055/s-2006-939679
    • Nathan CO, Chakradeo V, Malhotra K, D'Agostino H, Patwardhan R (2006) The voice-controlled robotic assist scope holder AESOP for the endoscopic approach to the sella. Skull Base 16:123-131
    • (2006) Skull Base , vol.16 , pp. 123-131
    • Nathan, C.O.1    Chakradeo, V.2    Malhotra, K.3    D'Agostino, H.4    Patwardhan, R.5
  • 36
    • 30844444382 scopus 로고    scopus 로고
    • Voice recognition interfaces (VRI) optimize the utilization of theatre staff and time during laparoscopic cholecystectomy
    • 16754183 10.1080/13645700500381685 1:STN:280:DC%2BD28zktFOlug%3D%3D
    • El-Shallaly GE, Mohammed B, Muhtaseb MS, Hamouda AH, Nassar AH (2005) Voice recognition interfaces (VRI) optimize the utilization of theatre staff and time during laparoscopic cholecystectomy. Minim Invasive Ther Allied Technol 14:369-371
    • (2005) Minim Invasive Ther Allied Technol , vol.14 , pp. 369-371
    • El-Shallaly, G.E.1    Mohammed, B.2    Muhtaseb, M.S.3    Hamouda, A.H.4    Nassar, A.H.5
  • 38
    • 79551557201 scopus 로고    scopus 로고
    • Using real-time clinical decision support to improve performance on perioperative quality and process measures
    • 21295752 10.1016/j.anclin.2010.11.002
    • Chau A, Ehrenfeld JM (2011) Using real-time clinical decision support to improve performance on perioperative quality and process measures. Anesthesiol Clin 29:57-69
    • (2011) Anesthesiol Clin , vol.29 , pp. 57-69
    • Chau, A.1    Ehrenfeld, J.M.2
  • 39
  • 40
    • 83055180546 scopus 로고    scopus 로고
    • Is robotic surgery cost-effective: No
    • 22080872 10.1097/MOU.0b013e32834d4d76
    • Lotan Y (2012) Is robotic surgery cost-effective: no. Curr Opin Urol 22:66-69
    • (2012) Curr Opin Urol , vol.22 , pp. 66-69
    • Lotan, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.