메뉴 건너뛰기




Volumn 37, Issue 4, 2013, Pages 357-367

Gaseous Micro-Emboli Activity During Cardiopulmonary Bypass in Adults: Pulsatile Flow Versus Nonpulsatile Flow

Author keywords

Cardiopulmonary bypass; Gaseous micro emboli; Membrane oxygenator; Pulsatile flow

Indexed keywords

PULSATILE FLOW; PUMPS;

EID: 84875917598     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12000     Document Type: Article
Times cited : (8)

References (32)
  • 1
    • 33846955080 scopus 로고    scopus 로고
    • Perioperative stroke
    • Selim M. Perioperative stroke. N Engl J Med 2007;356:706-713.
    • (2007) N Engl J Med , vol.356 , pp. 706-713
    • Selim, M.1
  • 2
    • 4644250598 scopus 로고    scopus 로고
    • Intraoperative and postoperative variables associated with strokes following cardiac surgery
    • Northern New England Cardiovascular Disease Study Group, Lebanon, New Hampshire
    • Likosky DS, Caplan LR, Weintraub RM, etal.; Northern New England Cardiovascular Disease Study Group, Lebanon, New Hampshire. Intraoperative and postoperative variables associated with strokes following cardiac surgery. Heart Surg Forum 2004;7:E271-276.
    • (2004) Heart Surg Forum , vol.7
    • Likosky, D.S.1    Caplan, L.R.2    Weintraub, R.M.3
  • 3
    • 0028914566 scopus 로고
    • Macroemboli and microemboli during cardiopulmonary bypass
    • Blauth CI. Macroemboli and microemboli during cardiopulmonary bypass. Ann Thorac Surg 1995;59:1300-1303.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1300-1303
    • Blauth, C.I.1
  • 4
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles: pathophysiology and clinical implications. Chest 2005;128:2918-2932.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 5
    • 0034652031 scopus 로고    scopus 로고
    • Microbubble persistence in the microcirculation during ischemia/reperfusion and inflammation is caused by integrin- and complement-mediated adherence to activated leukocytes
    • Lindner JR, Coggins MP, Kaul S, Klibanov AL, Brandenburger GH, Ley K. Microbubble persistence in the microcirculation during ischemia/reperfusion and inflammation is caused by integrin- and complement-mediated adherence to activated leukocytes. Circulation 2000;101:668-675.
    • (2000) Circulation , vol.101 , pp. 668-675
    • Lindner, J.R.1    Coggins, M.P.2    Kaul, S.3    Klibanov, A.L.4    Brandenburger, G.H.5    Ley, K.6
  • 7
    • 70349563897 scopus 로고    scopus 로고
    • The effects of cardiopulmonary bypass on the number of cerebral microemboli and the incidence of cognitive dysfunction after coronary artery bypass graft surgery
    • Liu YH, Wang DX, Li LH, etal. The effects of cardiopulmonary bypass on the number of cerebral microemboli and the incidence of cognitive dysfunction after coronary artery bypass graft surgery. Anesth Analg 2009;109:1013-1022.
    • (2009) Anesth Analg , vol.109 , pp. 1013-1022
    • Liu, Y.H.1    Wang, D.X.2    Li, L.H.3
  • 8
    • 0022517874 scopus 로고
    • Pathophysiology of brain damage during open-heart surgery
    • Taylor KM. Pathophysiology of brain damage during open-heart surgery. Tex Heart Inst J 1986;13:91-96.
    • (1986) Tex Heart Inst J , vol.13 , pp. 91-96
    • Taylor, K.M.1
  • 9
    • 50649090694 scopus 로고    scopus 로고
    • Microemboli detection on extracorporeal bypass circuits
    • Lynch JE, Riley JB. Microemboli detection on extracorporeal bypass circuits. Perfusion 2008;23:23-32.
    • (2008) Perfusion , vol.23 , pp. 23-32
    • Lynch, J.E.1    Riley, J.B.2
  • 10
    • 77949901003 scopus 로고    scopus 로고
    • Detection and elimination of microemboli related to cardiopulmonary bypass
    • Northern New England Cardiovascular Disease Study Group
    • Groom RC, Quinn RD, Lennon P, etal.; Northern New England Cardiovascular Disease Study Group. Detection and elimination of microemboli related to cardiopulmonary bypass. Circ Cardiovasc Qual Outcomes 2009;2:191-198.
    • (2009) Circ Cardiovasc Qual Outcomes , vol.2 , pp. 191-198
    • Groom, R.C.1    Quinn, R.D.2    Lennon, P.3
  • 11
    • 38449091286 scopus 로고    scopus 로고
    • Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation
    • Myers GJ. Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation. J Extra Corpor Technol 2007;39:192-198.
    • (2007) J Extra Corpor Technol , vol.39 , pp. 192-198
    • Myers, G.J.1
  • 12
    • 66249090552 scopus 로고    scopus 로고
    • Influence of venous reservoir level on microbubbles in cardiopulmonary bypass
    • Nielsen PF, Funder JA, Jensen MØ, Nygaard H. Influence of venous reservoir level on microbubbles in cardiopulmonary bypass. Perfusion 2008;23:347-353.
    • (2008) Perfusion , vol.23 , pp. 347-353
    • Nielsen, P.F.1    Funder, J.A.2    Jensen, M.3    Nygaard, H.4
  • 13
    • 68549132474 scopus 로고    scopus 로고
    • Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study
    • Myers GJ, Voorhees C, Haynes R, Eke B. Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study. J Extra Corpor Technol 2009;41:20-27.
    • (2009) J Extra Corpor Technol , vol.41 , pp. 20-27
    • Myers, G.J.1    Voorhees, C.2    Haynes, R.3    Eke, B.4
  • 14
    • 55949088780 scopus 로고    scopus 로고
    • Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children
    • Win KN, Wang S, Undar A. Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children. ASAIO J 2008;54:486-490.
    • (2008) ASAIO J , vol.54 , pp. 486-490
    • Win, K.N.1    Wang, S.2    Undar, A.3
  • 15
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • Undar A. Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif Organs 2004;28:439-443.
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Undar, A.1
  • 16
    • 33745602733 scopus 로고    scopus 로고
    • Pulsatile versus nonpulsatile cardiopulmonary bypass flow: an evidence-based approach
    • Alghamdi AA, Latter DA. Pulsatile versus nonpulsatile cardiopulmonary bypass flow: an evidence-based approach. J Card Surg 2006;21:347-354.
    • (2006) J Card Surg , vol.21 , pp. 347-354
    • Alghamdi, A.A.1    Latter, D.A.2
  • 17
    • 79951637555 scopus 로고    scopus 로고
    • Clinical effectiveness of centrifugal pump to produce pulsatile flow during cardiopulmonary bypass in patients undergoing cardiac surgery
    • Gu YJ, van Oeveren W, Mungroop HE, etal. Clinical effectiveness of centrifugal pump to produce pulsatile flow during cardiopulmonary bypass in patients undergoing cardiac surgery. Artif Organs 2011;35:E18-26.
    • (2011) Artif Organs , vol.35
    • Gu, Y.J.1    van Oeveren, W.2    Mungroop, H.E.3
  • 18
    • 0028318102 scopus 로고
    • Pulsatile flow and membrane oxygenators
    • Gourlay T, Taylor KM. Pulsatile flow and membrane oxygenators. Perfusion 1994;9:189-196.
    • (1994) Perfusion , vol.9 , pp. 189-196
    • Gourlay, T.1    Taylor, K.M.2
  • 19
    • 55949108154 scopus 로고    scopus 로고
    • Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model
    • Wang S, Kunselman AR, Myers JL, Undar A. Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model. ASAIO J 2008;54:538-541.
    • (2008) ASAIO J , vol.54 , pp. 538-541
    • Wang, S.1    Kunselman, A.R.2    Myers, J.L.3    Undar, A.4
  • 20
    • 55949094037 scopus 로고    scopus 로고
    • The capability of trapping gaseous microemboli of two pediatric arterial filters with pulsatile and nonpulsatile flow in a simulated infant CPB model
    • Wang S, Win KN, Kunselman AR, Woitas K, Myers JL, Undar A. The capability of trapping gaseous microemboli of two pediatric arterial filters with pulsatile and nonpulsatile flow in a simulated infant CPB model. ASAIO J 2008;54:519-522.
    • (2008) ASAIO J , vol.54 , pp. 519-522
    • Wang, S.1    Win, K.N.2    Kunselman, A.R.3    Woitas, K.4    Myers, J.L.5    Undar, A.6
  • 22
    • 0036964893 scopus 로고    scopus 로고
    • The ABCs of research on pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass
    • Undar A. The ABCs of research on pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass. Med Sci Monit 2002;8:ED21-24.
    • (2002) Med Sci Monit , vol.8
    • Undar, A.1
  • 23
    • 36549055239 scopus 로고    scopus 로고
    • Detection and classification of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model
    • Undar A, Ji B, Kunselman AR, Myers JL. Detection and classification of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model. ASAIO J 2007;53:725-729.
    • (2007) ASAIO J , vol.53 , pp. 725-729
    • Undar, A.1    Ji, B.2    Kunselman, A.R.3    Myers, J.L.4
  • 24
    • 51149097948 scopus 로고    scopus 로고
    • Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model
    • Wang S, Baer L, Kunselman AR, Myers JL, Undar A. Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model. ASAIO J 2008;54:416-422.
    • (2008) ASAIO J , vol.54 , pp. 416-422
    • Wang, S.1    Baer, L.2    Kunselman, A.R.3    Myers, J.L.4    Undar, A.5
  • 25
    • 70450250005 scopus 로고    scopus 로고
    • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops
    • Guan Y, Palanzo D, Kunselman A, Undar A. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops. Artif Organs 2009;33:1037-1043.
    • (2009) Artif Organs , vol.33 , pp. 1037-1043
    • Guan, Y.1    Palanzo, D.2    Kunselman, A.3    Undar, A.4
  • 26
    • 22044454813 scopus 로고    scopus 로고
    • Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter
    • Myers GJ, Gardiner K, Ditmore SN, etal. Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter. J Extra Corpor Technol 2005;37:201-206.
    • (2005) J Extra Corpor Technol , vol.37 , pp. 201-206
    • Myers, G.J.1    Gardiner, K.2    Ditmore, S.N.3
  • 27
    • 0028027768 scopus 로고
    • Hemodynamic analysis could resolve the pulsatile blood flow controversy
    • Wright G. Hemodynamic analysis could resolve the pulsatile blood flow controversy. Ann Thorac Surg 1994;58:1199-1204.
    • (1994) Ann Thorac Surg , vol.58 , pp. 1199-1204
    • Wright, G.1
  • 28
    • 77953769127 scopus 로고    scopus 로고
    • Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter
    • Guan Y, Su X, McCoach R, Wise R, Kunselman A, Undar A. Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter. J Extra Corpor Technol 2010;42:134-138.
    • (2010) J Extra Corpor Technol , vol.42 , pp. 134-138
    • Guan, Y.1    Su, X.2    McCoach, R.3    Wise, R.4    Kunselman, A.5    Undar, A.6
  • 29
    • 84862907730 scopus 로고    scopus 로고
    • In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters
    • Liu S, Newland RF, Tully PJ, Tuble SC, Baker RA. In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters. J Extra Corpor Technol 2011;43:107-114.
    • (2011) J Extra Corpor Technol , vol.43 , pp. 107-114
    • Liu, S.1    Newland, R.F.2    Tully, P.J.3    Tuble, S.C.4    Baker, R.A.5
  • 30
    • 76149129039 scopus 로고    scopus 로고
    • A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators
    • Jirschik M, Keyl C, Beyersdorf F. A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators. Perfusion 2009;24:423-427.
    • (2009) Perfusion , vol.24 , pp. 423-427
    • Jirschik, M.1    Keyl, C.2    Beyersdorf, F.3
  • 31
    • 78649612084 scopus 로고    scopus 로고
    • Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients
    • Qiu F, Guan Y, Su X, Kunselman A, Undar A. Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients. Artif Organs 2010;34:923-929.
    • (2010) Artif Organs , vol.34 , pp. 923-929
    • Qiu, F.1    Guan, Y.2    Su, X.3    Kunselman, A.4    Undar, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.