메뉴 건너뛰기




Volumn 33, Issue 11, 2009, Pages 1037-1043

Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops

Author keywords

Cardiopulmonary bypass; Embolism; Membrane oxygenation; Perfusion; Ultrasound

Indexed keywords

DROPS; OXYGENATION; PRESSURE DROP; ULTRASONIC APPLICATIONS;

EID: 70450250005     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00955.x     Document Type: Article
Times cited : (29)

References (11)
  • 1
    • 38449106375 scopus 로고    scopus 로고
    • Cerebral air emboli differentially alter outcome after cardiopulmonary bypass in rats compared with normal circulation
    • Jungwirth B, Kellermann K, Blobner M, Schmehl W, Kochs EF, Mackensen GB. Cerebral air emboli differentially alter outcome after cardiopulmonary bypass in rats compared with normal circulation. Anesthesiology 2007 107 : 768 775.
    • (2007) Anesthesiology , vol.107 , pp. 768-775
    • Jungwirth, B.1    Kellermann, K.2    Blobner, M.3    Schmehl, W.4    Kochs, E.F.5    MacKensen, G.B.6
  • 3
    • 61449223569 scopus 로고    scopus 로고
    • Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass
    • Wang S, Ündar A. Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass. J Extra Corpor Technol 2008 40 : 249 256.
    • (2008) J Extra Corpor Technol , vol.40 , pp. 249-256
    • Wang, S.1    Ündar, A.2
  • 4
    • 50649090694 scopus 로고    scopus 로고
    • Microemboli detection on extracorporeal bypass circuits
    • Lynch JE, Riley JB. Microemboli detection on extracorporeal bypass circuits. Perfusion 2008 23 : 23 32.
    • (2008) Perfusion , vol.23 , pp. 23-32
    • Lynch, J.E.1    Riley, J.B.2
  • 5
    • 55949084587 scopus 로고    scopus 로고
    • Gaseous microemboli detection in a simulated pediatric CPB circuit using a novel ultrasound system
    • Miller A, Wang S, Myers JL, Ündar A. Gaseous microemboli detection in a simulated pediatric CPB circuit using a novel ultrasound system. ASAIO J 2008 54 : 504 508.
    • (2008) ASAIO J , vol.54 , pp. 504-508
    • Miller, A.1    Wang, S.2    Myers, J.L.3    Ündar, A.4
  • 6
    • 46249109869 scopus 로고    scopus 로고
    • Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures
    • Schreiner RS, Rider AR, Myers JW, et al. Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures. ASAIO J 2008 54 : 316 324.
    • (2008) ASAIO J , vol.54 , pp. 316-324
    • Schreiner, R.S.1    Rider, A.R.2    Myers, J.W.3
  • 7
    • 22144448873 scopus 로고    scopus 로고
    • Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery
    • Perthel M, Kseibi S, Bendisch A, Laas J. Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery. Perfusion 2005 20 : 151 156.
    • (2005) Perfusion , vol.20 , pp. 151-156
    • Perthel, M.1    Kseibi, S.2    Bendisch, A.3    Laas, J.4
  • 8
    • 39049184851 scopus 로고    scopus 로고
    • In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs
    • Dickinson TA, Riley JB, Crowley JC, Zabetakis PM. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs. J Extra Corpor Technol 2006 38 : 206 213.
    • (2006) J Extra Corpor Technol , vol.38 , pp. 206-213
    • Dickinson, T.A.1    Riley, J.B.2    Crowley, J.C.3    Zabetakis, P.M.4
  • 9
    • 22144484113 scopus 로고    scopus 로고
    • Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates
    • Ündar A, Owens WR, McGarry MC, et al. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates. Perfusion 2005 20 : 135 138.
    • (2005) Perfusion , vol.20 , pp. 135-138
    • Ündar, A.1    Owens, W.R.2    McGarry, M.C.3
  • 10
    • 5444240838 scopus 로고    scopus 로고
    • Ex vivo evaluation of a new neonatal/infant oxygenator: Comparison of the Terumo Capiox Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model
    • Dubois J, Jamaer L, Mees U, et al. Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo Capiox Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model. Perfusion 2004 19 : 315 321.
    • (2004) Perfusion , vol.19 , pp. 315-321
    • Dubois, J.1    Jamaer, L.2    Mees, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.