-
1
-
-
67649406069
-
A new de-airing technique that reduces systemic microemboli during open surgery: A prospective controlled study
-
Al-Rashidi F, Blomquist S, Höglund P, Meurling C, Roijer A, Koul B. A new de-airing technique that reduces systemic microemboli during open surgery: A prospective controlled study. J Thorac Cardiovasc Surg. 2009;138:157-62.
-
(2009)
J Thorac Cardiovasc Surg
, vol.138
, pp. 157-162
-
-
Al-Rashidi, F.1
Blomquist, S.2
Höglund, P.3
Meurling, C.4
Roijer, A.5
Koul, B.6
-
3
-
-
22144448873
-
Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery
-
DOI 10.1191/0267659105pf813oa
-
Perthel M, Kseibi S, Bendisch A, Laas J. Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery. Perfusion. 2005;20:151-6. (Pubitemid 40975733)
-
(2005)
Perfusion
, vol.20
, Issue.3
, pp. 151-156
-
-
Perthel, M.1
Kseibi, S.2
Bendisch, A.3
Laas, J.4
-
4
-
-
61449223569
-
Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass
-
Wang S, Ündar A. Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass. J Extra Corpor Technol. 2008;40:249-56.
-
(2008)
J Extra Corpor Technol
, vol.40
, pp. 249-256
-
-
Wang, S.1
Ündar, A.2
-
5
-
-
46249109869
-
Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures
-
Schreiner RS, Rider AR, Myers JW, et al. Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures. ASAIO J. 2008;54:316-24.
-
(2008)
ASAIO J
, vol.54
, pp. 316-324
-
-
Schreiner, R.S.1
Rider, A.R.2
Myers, J.W.3
-
6
-
-
55949108154
-
Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model
-
Wang S, Kunselman AR, Myers JL, Ündar A. Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model. ASAIO J. 2008;54:538-41.
-
(2008)
ASAIO J
, vol.54
, pp. 538-541
-
-
Wang, S.1
Kunselman, A.R.2
Myers, J.L.3
Ündar, A.4
-
7
-
-
70450250005
-
Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops
-
Guan Y, Palanzo D, Kunselman AR, Ündar A. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops. Artif Organs. 2009;33:1037-43.
-
(2009)
Artif Organs
, vol.33
, pp. 1037-1043
-
-
Guan, Y.1
Palanzo, D.2
Kunselman, A.R.3
Ündar, A.4
-
8
-
-
51149120650
-
"Stolen" blood flow: The effects of an open arterial filter purge line in a simulated neonatal CPB model
-
Wang S, Miller A, Myers JL, Ündar A. "Stolen" blood flow: The effects of an open arterial filter purge line in a simulated neonatal CPB model. ASAIO J. 2008;54:432-5.
-
(2008)
ASAIO J
, vol.54
, pp. 432-435
-
-
Wang, S.1
Miller, A.2
Myers, J.L.3
Ündar, A.4
-
9
-
-
50649090694
-
Microemboli detection on extracorporeal bypass circuits
-
Lynch JE, Riley JB. Microemboli detection on extracorporeal bypass circuits. Perfusion. 2008;23:23-32.
-
(2008)
Perfusion
, vol.23
, pp. 23-32
-
-
Lynch, J.E.1
Riley, J.B.2
|