-
1
-
-
0033912355
-
Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology
-
Wefer AE, Hricak H, Vigneron DB, et al. Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology. J Urol 2000; 164(2): 400-404.
-
(2000)
J Urol
, vol.164
, Issue.2
, pp. 400-404
-
-
Wefer, A.E.1
Hricak, H.2
Vigneron, D.B.3
-
2
-
-
0033957216
-
Imaging prostate cancer
-
Yu KK, Hricak H. Imaging prostate cancer. Radiol Clin North Am 2000; 38(1): 59-85viii.
-
(2000)
Radiol Clin North Am
, vol.38
, Issue.1
, pp. 59-858
-
-
Yu, K.K.1
Hricak, H.2
-
3
-
-
47949096177
-
MR-guided biopsy of the prostate: an overview of techniques and a systematic review
-
Pondman KM, Futterer JJ, ten Haken B, et al. MR-guided biopsy of the prostate: an overview of techniques and a systematic review. Eur Urol 2008; 54(3): 517-527.
-
(2008)
Eur Urol
, vol.54
, Issue.3
, pp. 517-527
-
-
Pondman, K.M.1
Futterer, J.J.2
ten Haken, B.3
-
5
-
-
0031724260
-
Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer
-
D'Amico AV, Cormack R, Tempany CM, et al. Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer. Int J Radiat Oncol Biol Phys 1998; 42(3): 507-515.
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.42
, Issue.3
, pp. 507-515
-
-
D'Amico, A.V.1
Cormack, R.2
Tempany, C.M.3
-
6
-
-
0033927199
-
Transperineal magnetic resonance image guided prostate biopsy
-
D'Amico AV, Tempany CM, Cormack R, et al. Transperineal magnetic resonance image guided prostate biopsy. J Urol 2000; 164(2): 385-387.
-
(2000)
J Urol
, vol.164
, Issue.2
, pp. 385-387
-
-
D'Amico, A.V.1
Tempany, C.M.2
Cormack, R.3
-
7
-
-
33744818910
-
Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device
-
Engelhard K, Hollenbach HP, Kiefer B, et al. Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device. Eur Radiol 2006; 16(6): 1237-1243.
-
(2006)
Eur Radiol
, vol.16
, Issue.6
, pp. 1237-1243
-
-
Engelhard, K.1
Hollenbach, H.P.2
Kiefer, B.3
-
8
-
-
58149392649
-
Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility
-
Hambrock T, Futterer JJ, Huisman HJ, et al. Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility. Invest Radiol 2008; 43(10): 686-694.
-
(2008)
Invest Radiol
, vol.43
, Issue.10
, pp. 686-694
-
-
Hambrock, T.1
Futterer, J.J.2
Huisman, H.J.3
-
9
-
-
3242673606
-
MRI-guided HDR prostate brachytherapy in standard 1.5T scanner
-
Menard C, Susil RC, Choyke P, et al. MRI-guided HDR prostate brachytherapy in standard 1.5T scanner. Int J Radiat Oncol Biol Phys 2004; 59(5): 1414-1423.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, Issue.5
, pp. 1414-1423
-
-
Menard, C.1
Susil, R.C.2
Choyke, P.3
-
10
-
-
4243072965
-
System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner
-
Susil RC, Camphausen K, Choyke P, et al. System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner. Magn Reson Med 2004; 52(3): 683-687.
-
(2004)
Magn Reson Med
, vol.52
, Issue.3
, pp. 683-687
-
-
Susil, R.C.1
Camphausen, K.2
Choyke, P.3
-
11
-
-
29144456741
-
Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner
-
Susil RC, Menard C, Krieger A, et al. Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner. J Urol 2006; 175(1): 113-120.
-
(2006)
J Urol
, vol.175
, Issue.1
, pp. 113-120
-
-
Susil, R.C.1
Menard, C.2
Krieger, A.3
-
13
-
-
46349109295
-
MRI-compatible pneumatic robot for transperineal prostate needle placement
-
Fischer GS, Iordachita I, Csoma C, et al. MRI-compatible pneumatic robot for transperineal prostate needle placement. IEEE ASME Trans Mechatron 2008; 13(3): 295-305.
-
(2008)
IEEE ASME Trans Mechatron
, vol.13
, Issue.3
, pp. 295-305
-
-
Fischer, G.S.1
Iordachita, I.2
Csoma, C.3
-
15
-
-
76849094511
-
MRI-guided robotic system for transperineal prostate interventions: proof of principle
-
van den Bosch MR, Moman MR, van Vulpen M, et al. MRI-guided robotic system for transperineal prostate interventions: proof of principle. Phys Med Biol 2010; 55(5): N133-140.
-
(2010)
Phys Med Biol
, vol.55
, Issue.5
-
-
van den Bosch, M.R.1
Moman, M.R.2
van Vulpen, M.3
-
16
-
-
79959556966
-
Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance
-
Yakar D, Schouten MG, Bosboom DG, et al. Feasibility of a pneumatically actuated MR-compatible robot for transrectal prostate biopsy guidance. Radiology 2011; 260(1): 241-247.
-
(2011)
Radiology
, vol.260
, Issue.1
, pp. 241-247
-
-
Yakar, D.1
Schouten, M.G.2
Bosboom, D.G.3
-
17
-
-
84860246008
-
-
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing. In IEEE International Conference on Robotics and Automation
-
Su H, Zervas M, Cole G, et al. Real-time MRI-guided needle placement robot with integrated fiber optic force sensing. In IEEE International Conference on Robotics and Automation, 2011: 1583-1588.
-
(2011)
, pp. 1583-1588
-
-
Su, H.1
Zervas, M.2
Cole, G.3
-
18
-
-
77955831325
-
-
Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: new approaches. In IEEE International Conference on Robotics and Automation
-
Song SE, Cho NB, Fischer G, et al. Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: new approaches. In IEEE International Conference on Robotics and Automation, 2010; 2580-2585.
-
(2010)
, pp. 2580-2585
-
-
Song, S.E.1
Cho, N.B.2
Fischer, G.3
-
19
-
-
78650371528
-
-
Preliminary evaluation of a MRI-compatible modular robotic system for MRI-guided prostate interventions. In Proceedings of the IEEE RAS EMBS International Conference on Biomedical Robotics and Biomechatronics
-
Song SE, Cho N, Tokuda J, et al. Preliminary evaluation of a MRI-compatible modular robotic system for MRI-guided prostate interventions. In Proceedings of the IEEE RAS EMBS International Conference on Biomedical Robotics and Biomechatronics, 2010; 2010: 796-801.
-
(2010)
, vol.2010
, pp. 796-801
-
-
Song, S.E.1
Cho, N.2
Tokuda, J.3
-
20
-
-
84874993358
-
-
National Electrical Manufacturers Association (NEMA). MS 1-2008. Determination of signal:noise ratio (SNR) in diagnostic magnetic resonance imaging. NEMA
-
National Electrical Manufacturers Association (NEMA). MS 1-2008. Determination of signal:noise ratio (SNR) in diagnostic magnetic resonance imaging. NEMA, 2008: http: //www.nema.org/stds/ms1.cfm
-
(2008)
-
-
-
21
-
-
84862240712
-
-
Reconfigurable MRI-guided robotic surgical manipulator: prostate brachytherapy and neurosurgery applications. In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
-
Su H, Iordachita I, Yan X, et al. Reconfigurable MRI-guided robotic surgical manipulator: prostate brachytherapy and neurosurgery applications. In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2011.
-
(2011)
-
-
Su, H.1
Iordachita, I.2
Yan, X.3
-
22
-
-
84866493469
-
Development and evaluation of an actuated MRI-compatible robotic system for MRI-guided prostate intervention
-
Krieger A, Song S-E, Cho NB, et al. Development and evaluation of an actuated MRI-compatible robotic system for MRI-guided prostate intervention. IEEE/ASME Trans Mechatron 2011.
-
(2011)
IEEE/ASME Trans Mechatron
-
-
Krieger, A.1
Song, S.-E.2
Cho, N.B.3
|