메뉴 건너뛰기




Volumn 102, Issue 4, 2013, Pages 1209-1221

Influence of array interspacing on the force required for successful microneedle skin penetration: Theoretical and practical approaches

Author keywords

Absorption enhancer; Drug transport; Interspacing; Mathematical model; Microfabrication; Microneedle; Permeability; Skin; Transdermal

Indexed keywords

ARTICLE; DRUG DELIVERY SYSTEM; FINITE ELEMENT ANALYSIS; FORCE; GEOMETRY; MECHANICAL STRESS; MICRONEEDLE; MICROTECHNOLOGY; NONHUMAN; SKIN PENETRATION; SKIN STRUCTURE; SWINE; YOUNG MODULUS;

EID: 84874685139     PISSN: 00223549     EISSN: 15206017     Source Type: Journal    
DOI: 10.1002/jps.23439     Document Type: Article
Times cited : (184)

References (52)
  • 1
    • 0031852494 scopus 로고    scopus 로고
    • Microfabricated microneedles: A novel approach to transdermal drug delivery
    • Henry S, McAllister DV, Allen MG, Prausnitz MR. 1998. Microfabricated microneedles: A novel approach to transdermal drug delivery. J Pharm Sci 87:922-925.
    • (1998) J Pharm Sci , vol.87 , pp. 922-925
    • Henry, S.1    McAllister, D.V.2    Allen, M.G.3    Prausnitz, M.R.4
  • 2
    • 1542358759 scopus 로고    scopus 로고
    • Microneedles for transdermal drug delivery
    • Prausnitz MR. 2004. Microneedles for transdermal drug delivery. Adv Drug Deliv Rev 56:581-587.
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 581-587
    • Prausnitz, M.R.1
  • 3
    • 77950044549 scopus 로고    scopus 로고
    • The effect of strain rate on the precision of penetration of short densely packed microprojection array patches coated with vaccine
    • Crichton ML, Ansaldo A, Chen X, Prow TW, Fernando GJP, Kendall MAF. 2010. The effect of strain rate on the precision of penetration of short densely packed microprojection array patches coated with vaccine. Biomaterials 31(16):4562-4572.
    • (2010) Biomaterials , vol.31 , Issue.16 , pp. 4562-4572
    • Crichton, M.L.1    Ansaldo, A.2    Chen, X.3    Prow, T.W.4    Fernando, G.J.P.5    Kendall, M.A.F.6
  • 4
    • 4344712955 scopus 로고    scopus 로고
    • Geometrical effects in mechanical characterizing of microneedle for biomedical applications
    • Aggarwal P, Johnston CR. 2004. Geometrical effects in mechanical characterizing of microneedle for biomedical applications. Sens Actuators B 102:226-234.
    • (2004) Sens Actuators B , vol.102 , pp. 226-234
    • Aggarwal, P.1    Johnston, C.R.2
  • 5
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
    • Davis SP, Landis BJ, Adams ZH, Allen MG, Prausnitz MR. 2004. Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force. J Biomech 37:1155-1163.
    • (2004) J Biomech , vol.37 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 7
    • 82255179524 scopus 로고    scopus 로고
    • Modelling transdermal drug delivery using microneedles: Effect of geometry on drug transport behaviour
    • Olatunji O, Das DB, Nassehi V. 2012. Modelling transdermal drug delivery using microneedles: Effect of geometry on drug transport behaviour. J Pharm Sci 101(1):164-175.
    • (2012) J Pharm Sci , vol.101 , Issue.1 , pp. 164-175
    • Olatunji, O.1    Das, D.B.2    Nassehi, V.3
  • 9
    • 77952886320 scopus 로고    scopus 로고
    • Evaluation of needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery
    • Yan G, Warner KS, Zhang J, Sharma S, Gale BK. 2010. Evaluation of needle length and density of microneedle arrays in the pretreatment of skin for transdermal drug delivery. Int J Pharm 391:7-12.
    • (2010) Int J Pharm , vol.391 , pp. 7-12
    • Yan, G.1    Warner, K.S.2    Zhang, J.3    Sharma, S.4    Gale, B.K.5
  • 10
    • 41749123410 scopus 로고    scopus 로고
    • Optimization of square microneedle arrays for increasing drug permeability in skin
    • Al-Qallaf B, Das DB. 2008. Optimization of square microneedle arrays for increasing drug permeability in skin. Chem Eng Sci 63:2523-2535.
    • (2008) Chem Eng Sci , vol.63 , pp. 2523-2535
    • Al-Qallaf, B.1    Das, D.B.2
  • 11
    • 58149473077 scopus 로고    scopus 로고
    • Optimizing microneedle arrays for transdermal drug delivery: Extension to non-square distribution of microneedles
    • Al-Qallaf B, Das DB. 2009. Optimizing microneedle arrays for transdermal drug delivery: Extension to non-square distribution of microneedles. J Drug Target 17(2):108-122.
    • (2009) J Drug Target , vol.17 , Issue.2 , pp. 108-122
    • Al-Qallaf, B.1    Das, D.B.2
  • 12
    • 65249152512 scopus 로고    scopus 로고
    • Optimisation of micro-needle arrays to increase skin permeability for transdermal drug delivery
    • Al-Qallaf B, Das DB. 2009. Optimisation of micro-needle arrays to increase skin permeability for transdermal drug delivery. Ann N Y Acad Sci 1161:83-94.
    • (2009) Ann N Y Acad Sci , vol.1161 , pp. 83-94
    • Al-Qallaf, B.1    Das, D.B.2
  • 13
  • 14
    • 73449113330 scopus 로고    scopus 로고
    • Transdermal drug delivery by coated microneedles: Geometry effects on drug concentration in blood
    • Al-Qallaf B, Das DB, Davidson A. 2009. Transdermal drug delivery by coated microneedles: Geometry effects on drug concentration in blood. Asia-Pacific J Chem Eng 4(6):845-857.
    • (2009) Asia-Pacific J Chem Eng , vol.4 , Issue.6 , pp. 845-857
    • Al-Qallaf, B.1    Das, D.B.2    Davidson, A.3
  • 15
    • 38449095606 scopus 로고    scopus 로고
    • Modelling transdermal delivery of high molecular weight drugs from micro-needle systems
    • Al-Qallaf B, Das DB, Mori D, Cui ZF. 2007. Modelling transdermal delivery of high molecular weight drugs from micro-needle systems. Philos Transact A Math Phys Eng Sci 365(1861):2951-2967.
    • (2007) Philos Transact A Math Phys Eng Sci , vol.365 , Issue.1861 , pp. 2951-2967
    • Al-Qallaf, B.1    Das, D.B.2    Mori, D.3    Cui, Z.F.4
  • 16
    • 78049472743 scopus 로고    scopus 로고
    • Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution
    • Donnelly RF, Garland MJ, Morrow DIJ, Migalska K, Singh TR, Majithiya R, Woolfson AD. 2010. Optical coherence tomography is a valuable tool in the study of the effects of microneedle geometry on skin penetration characteristics and in-skin dissolution. J Control Release 147(3):333-341.
    • (2010) J Control Release , vol.147 , Issue.3 , pp. 333-341
    • Donnelly, R.F.1    Garland, M.J.2    Morrow, D.I.J.3    Migalska, K.4    Singh, T.R.5    Majithiya, R.6    Woolfson, A.D.7
  • 17
    • 3042572777 scopus 로고    scopus 로고
    • Force modelling for needle insertion into soft tissue
    • Okamura AM, Simone C, O'Leary MD. 2004. Force modelling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51(10):1707-1716.
    • (2004) IEEE Trans Biomed Eng , vol.51 , Issue.10 , pp. 1707-1716
    • Okamura, A.M.1    Simone, C.2    O'Leary, M.D.3
  • 18
    • 0036057655 scopus 로고    scopus 로고
    • Haptic modelling of needle insertion for robot-assisted percutaneous therapy
    • In May
    • Simone C, Okamura A. 2002. Haptic modelling of needle insertion for robot-assisted percutaneous therapy. In Proc IEEE Int Conf Robotica Automation May; pp 2085-2091.
    • (2002) Proc IEEE Int Conf Robotica Automation , pp. 2085-2091
    • Simone, C.1    Okamura, A.2
  • 19
    • 0344377940 scopus 로고    scopus 로고
    • Modelling of needle insertion forces for percutaneous therapies
    • Baltimore, Maryland: Johns Hopkins University.
    • Simone C. 2002. Modelling of needle insertion forces for percutaneous therapies. Master's Thesis. Baltimore, Maryland: Johns Hopkins University.
    • (2002) Master's Thesis
    • Simone, C.1
  • 21
    • 0142258214 scopus 로고    scopus 로고
    • Needle insertion modelling and simulation
    • DiMaio SP, Salcudean SE. 2003. Needle insertion modelling and simulation. IEEE Trans Robot Automat 19(5):864-875.
    • (2003) IEEE Trans Robot Automat , vol.19 , Issue.5 , pp. 864-875
    • DiMaio, S.P.1    Salcudean, S.E.2
  • 22
    • 20444448852 scopus 로고    scopus 로고
    • Interactive simulation of needle insertion models
    • DiMaio SP, Salcudean SE. 2005. Interactive simulation of needle insertion models. IEEE Trans Biomed Eng 52(7):1167-1179.
    • (2005) IEEE Trans Biomed Eng , vol.52 , Issue.7 , pp. 1167-1179
    • DiMaio, S.P.1    Salcudean, S.E.2
  • 23
    • 69549114522 scopus 로고    scopus 로고
    • A realtime prostate cancer detection technique using needle insertion force and patientspecific criteria during percutaneous intervention
    • Yan K, Podder T, Li L, Joseph J, Rubens DR, Messing EM, Liao L, Yu Y. 2009. A realtime prostate cancer detection technique using needle insertion force and patientspecific criteria during percutaneous intervention. Med Phys 36: 41484-41491.
    • (2009) Med Phys , vol.36 , pp. 41484-41491
    • Yan, K.1    Podder, T.2    Li, L.3    Joseph, J.4    Rubens, D.R.5    Messing, E.M.6    Liao, L.7    Yu, Y.8
  • 24
    • 0345276971 scopus 로고    scopus 로고
    • Haptic rendering of cutting: A fracture mechanics approach
    • Mahvash M, Hayward V. 2001. Haptic rendering of cutting: A fracture mechanics approach. Haptics-e 2(3):1-12.
    • (2001) Haptics-e , vol.2 , Issue.3 , pp. 1-12
    • Mahvash, M.1    Hayward, V.2
  • 26
    • 49049116947 scopus 로고    scopus 로고
    • Estimation of the fracture toughness of soft tissue from needle insertion
    • In, Bello F, Edwards E (Eds.). Springer Verlag
    • Azar T, Hayward V. 2008. Estimation of the fracture toughness of soft tissue from needle insertion. In Proc Biomed Simulation, 4th Int Symp ISBMS Lcture Notes in Computer Science, Bello F, Edwards E (Eds.). Springer Verlag. 5104:166-175.
    • (2008) Proc Biomed Simulation, 4th Int Symp ISBMS Lcture Notes in Computer Science , vol.5104 , pp. 166-175
    • Azar, T.1    Hayward, V.2
  • 28
    • 0029403360 scopus 로고
    • Moisture-activated electrically conducting bioadhesive hydrogels as interfaces for bioelectrodes: Effect of film hydration on cutaneous adherence in wet environments
    • Woolfson AD, McCafferty DF, McCallion CR, McAdams ET, Anderson J. 1995. Moisture-activated electrically conducting bioadhesive hydrogels as interfaces for bioelectrodes: Effect of film hydration on cutaneous adherence in wet environments. J Appl Polym Sci 58:1291-1296.
    • (1995) J Appl Polym Sci , vol.58 , pp. 1291-1296
    • Woolfson, A.D.1    McCafferty, D.F.2    McCallion, C.R.3    McAdams, E.T.4    Anderson, J.5
  • 29
    • 0024821527 scopus 로고
    • Miniature pig as an animal model to study photoaging
    • Fourtanier A, Berrebi C. 1989. Miniature pig as an animal model to study photoaging. Photochem Photobiol 50(6):771-784.
    • (1989) Photochem Photobiol , vol.50 , Issue.6 , pp. 771-784
    • Fourtanier, A.1    Berrebi, C.2
  • 32
    • 43049083754 scopus 로고    scopus 로고
    • Mechanical approach to aging and wrinkling of human facial skin based on the multistage buckling theory
    • Kuwazuru O, Saothong J, Yoshikawa N. 2008. Mechanical approach to aging and wrinkling of human facial skin based on the multistage buckling theory. Med Eng Phys 30:516-522.
    • (2008) Med Eng Phys , vol.30 , pp. 516-522
    • Kuwazuru, O.1    Saothong, J.2    Yoshikawa, N.3
  • 33
    • 34249770337 scopus 로고
    • Postbuckling behaviour of an ideal bar on an elastic foundation
    • Astapov NS, Kornev VM. 1994. Postbuckling behaviour of an ideal bar on an elastic foundation. J Appl Mech Tech Phys 35(2):286-296.
    • (1994) J Appl Mech Tech Phys , vol.35 , Issue.2 , pp. 286-296
    • Astapov, N.S.1    Kornev, V.M.2
  • 34
    • 84874750670 scopus 로고
    • A general solution for the bending of beams on an elastic foundation of arbitrary continuity. In The 7th International Congress of Applied Mechanics. London, England; September 5-11
    • Hetenyi M. 1948. A general solution for the bending of beams on an elastic foundation of arbitrary continuity. In The 7th International Congress of Applied Mechanics. London, England; September 5-11. 21:55-58.
    • (1948) , vol.21 , pp. 55-58
    • Hetenyi, M.1
  • 35
    • 0000915785 scopus 로고
    • Beams on elastic subgrade and the Winkler's hypothesis. In: Proceedings of the 5th International Conference on Soil Mechanics. Fdn, Engrg
    • Vesic AB. 1961. Beams on elastic subgrade and the Winkler's hypothesis. In: Proceedings of the 5th International Conference on Soil Mechanics. Fdn, Engrg., 1:845-850.
    • (1961) , vol.1 , pp. 845-850
    • Vesic, A.B.1
  • 37
    • 33644612020 scopus 로고    scopus 로고
    • Measuring the microelastic properties of stratum corneum
    • Yuan Y, Verma R. 2006. Measuring the microelastic properties of stratum corneum. Colloids Surf B Biointerfaces 48:6-12.
    • (2006) Colloids Surf B Biointerfaces , vol.48 , pp. 6-12
    • Yuan, Y.1    Verma, R.2
  • 38
    • 0025115692 scopus 로고
    • Frictional properties of human skin: Relation to age, sex and anatomical region, stratum corneum hydration and transepidermal water loss
    • Cua AB, Wilhelm KP, Maibach HI. 1990. Frictional properties of human skin: Relation to age, sex and anatomical region, stratum corneum hydration and transepidermal water loss. Br J Dermatol 123(4):473-479.
    • (1990) Br J Dermatol , vol.123 , Issue.4 , pp. 473-479
    • Cua, A.B.1    Wilhelm, K.P.2    Maibach, H.I.3
  • 39
    • 34250746500 scopus 로고    scopus 로고
    • On the design of an electronic mosquito: design and analysis of the microneedle. In: Proceedings of the International Conference on MEMS, NANO and Smart Systems 23rd July, 2003, Banff, Alta, Canada
    • Sharaf R, Aggarwal P, Kaler KVIS, Badawy W. 2003. On the design of an electronic mosquito: design and analysis of the microneedle. In: Proceedings of the International Conference on MEMS, NANO and Smart Systems 23rd July, 2003, Banff, Alta, Canada. p 32-35
    • (2003) , pp. 32-35
    • Sharaf, R.1    Aggarwal, P.2    Kaler, K.V.I.S.3    Badawy, W.4
  • 40
    • 0003513999 scopus 로고
    • 1st ed. New York and London: McGraw-Hill Book Company, Inc
    • Timoshenko S. 1961. Theory of elastic stability. 1st ed. New York and London: McGraw-Hill Book Company, Inc., pp 108-111.
    • (1961) Theory of elastic stability , pp. 108-111
    • Timoshenko, S.1
  • 43
    • 0022027550 scopus 로고
    • Computer simulation of stick-slip friction in mechanical dynamic systems
    • Karnopp D. 1985. Computer simulation of stick-slip friction in mechanical dynamic systems. Trans ASME J Dyn Syst Meas Control 107:100-103.
    • (1985) Trans ASME J Dyn Syst Meas Control , vol.107 , pp. 100-103
    • Karnopp, D.1
  • 47
    • 33751172945 scopus 로고    scopus 로고
    • In vivo data of epidermal thickness evaluated by optical coherence tomography: Effects of age, gender, skin type and anatomical site
    • Gambichler T, Matip R, Moussa G, Altmeyer P, Hoffmann K. 2006. In vivo data of epidermal thickness evaluated by optical coherence tomography: Effects of age, gender, skin type and anatomical site. J Dermatol Sci 44(3):145-152.
    • (2006) J Dermatol Sci , vol.44 , Issue.3 , pp. 145-152
    • Gambichler, T.1    Matip, R.2    Moussa, G.3    Altmeyer, P.4    Hoffmann, K.5
  • 48
    • 0019129751 scopus 로고
    • Mechanical properties and Young's modulus of human skin in vivo
    • Agache P, Monneur C, Leveque LJ, De Rigal J. 1980. Mechanical properties and Young's modulus of human skin in vivo. Arch Dermatol Res 269:221-232.
    • (1980) Arch Dermatol Res , vol.269 , pp. 221-232
    • Agache, P.1    Monneur, C.2    Leveque, L.J.3    De, R.J.4
  • 49
    • 0031101949 scopus 로고    scopus 로고
    • Relationship between structure of finger tissue and location of tactile receptors
    • Maeno T, Kobayashi K, Yamazaki N. 1997. Relationship between structure of finger tissue and location of tactile receptors. Trans Jpn Soc Mech Eng 63C:881-888.
    • (1997) Trans Jpn Soc Mech Eng , vol.63 C , pp. 881-888
    • Maeno, T.1    Kobayashi, K.2    Yamazaki, N.3
  • 50
    • 58149280496 scopus 로고    scopus 로고
    • Site-specific effects of compression on macromolecular diffusion in articular cartilage
    • Leddy HA, Guilak F. 2008. Site-specific effects of compression on macromolecular diffusion in articular cartilage. Biophys J 95:4890-4895.
    • (2008) Biophys J , vol.95 , pp. 4890-4895
    • Leddy, H.A.1    Guilak, F.2
  • 51
    • 33745758519 scopus 로고    scopus 로고
    • Diffusional anisotropy in collagenous tissues: Fluorescence imaging of continuous point photobleaching
    • Leddy HA, Haider MA, Guilak F. 2006. Diffusional anisotropy in collagenous tissues: Fluorescence imaging of continuous point photobleaching. J Biophys 91:311-316.
    • (2006) J Biophys , vol.91 , pp. 311-316
    • Leddy, H.A.1    Haider, M.A.2    Guilak, F.3
  • 52
    • 32544446281 scopus 로고    scopus 로고
    • Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system
    • Widera G, Johnson J, Kim L, Libiran L, Nyam K, Daddona PE, Cormier M. 2006. Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system. Vaccine 24:1653-1664.
    • (2006) Vaccine , vol.24 , pp. 1653-1664
    • Widera, G.1    Johnson, J.2    Kim, L.3    Libiran, L.4    Nyam, K.5    Daddona, P.E.6    Cormier, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.