메뉴 건너뛰기




Volumn 50, Issue 11, 2012, Pages 1873-1875

The measurement of 25-hydroxy vitamin D - An analytical challenge

Author keywords

[No Author keywords available]

Indexed keywords

25 HYDROXYVITAMIN D;

EID: 84872917380     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2012-0526     Document Type: Review
Times cited : (23)

References (16)
  • 1
    • 84872957263 scopus 로고    scopus 로고
    • Medical Benefits Reviews Task Group. Australian Government, Department of Health and Aging
    • Medical Benefits Reviews Task Group. Vitamin D testing. Review of the funding arrangements for pathology services. Australian Government, Department of Health and Aging. 2011 p. 60 - 1.
    • Vitamin D Testing. Review of the Funding Arrangements for Pathology Services , vol.2011 , pp. 60-61
  • 2
    • 84857866069 scopus 로고    scopus 로고
    • State-of-the-art vitamin D assays: A comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods
    • Farrell CJ, Martin S, McWhinney B, Straub I, Williams P, Herrmann M. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods. Clin Chem 2012;58:531 - 42.
    • (2012) Clin Chem , vol.58 , pp. 531-542
    • Farrell, C.J.1    Martin, S.2    McWhinney, B.3    Straub, I.4    Williams, P.5    Herrmann, M.6
  • 3
    • 77957267786 scopus 로고    scopus 로고
    • A new quantitative LC tandem mass spectrometry assay for serum 25-hydroxy vitamin D
    • Herrmann M, Harwood T, Gaston-Parry O, Kouzios D, Wong T, Lih A, et al. A new quantitative LC tandem mass spectrometry assay for serum 25-hydroxy vitamin D. Steroids 2010;75:1106 - 12.
    • (2010) Steroids , vol.75 , pp. 1106-1112
    • Herrmann, M.1    Harwood, T.2    Gaston-Parry, O.3    Kouzios, D.4    Wong, T.5    Lih, A.6
  • 4
    • 0034926269 scopus 로고    scopus 로고
    • Validation of the first automated chemiluminescence protein-binding assay for the detection of 25-hydroxycalciferol
    • Roth HJ, Zahn I, Alkier R, Schmidt H. Validation of the first automated chemiluminescence protein-binding assay for the detection of 25-hydroxycalciferol. Clin Lab 2001;47:357 - 65.
    • (2001) Clin Lab , vol.47 , pp. 357-365
    • Roth, H.J.1    Zahn, I.2    Alkier, R.3    Schmidt, H.4
  • 5
    • 0141741184 scopus 로고    scopus 로고
    • Issues of methodology, standardization and metabolite recognition for 25-hydroxyvitamin D when comparing the DiaSorin radioimmunoassay and the Nichols Advantage automated chemiluminescence protein-binding assay in hip fracture cases
    • Glendenning P, Noble JM, Taranto M, Musk AA, McGuiness M, Goldswain PR, et al. Issues of methodology, standardization and metabolite recognition for 25-hydroxyvitamin D when comparing the DiaSorin radioimmunoassay and the Nichols Advantage automated chemiluminescence protein-binding assay in hip fracture cases. Ann Clin Biochem 2003;40:546 - 51.
    • (2003) Ann Clin Biochem , vol.40 , pp. 546-551
    • Glendenning, P.1    Noble, J.M.2    Taranto, M.3    Musk, A.A.4    McGuiness, M.5    Goldswain, P.R.6
  • 6
    • 44249122585 scopus 로고    scopus 로고
    • Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference
    • Roth HJ, Schmidt-Gayk H, Weber H, Niederau C. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference. Ann Clin Biochem 2008;45:153 - 9.
    • (2008) Ann Clin Biochem , vol.45 , pp. 153-159
    • Roth, H.J.1    Schmidt-Gayk, H.2    Weber, H.3    Niederau, C.4
  • 9
    • 84872942722 scopus 로고    scopus 로고
    • Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples
    • Le Goff C, Peeters S, Crine Y, Lukas P, Souberbielle JC, Cavalier E. Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples. Clin Chem Lab Med 2012;50:2031-2.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 2031-2032
    • Le Goff, C.1    Peeters, S.2    Crine, Y.3    Lukas, P.4    Souberbielle, J.C.5    Cavalier, E.6
  • 10
    • 84872956067 scopus 로고    scopus 로고
    • Measurement of 25- hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays
    • Carrozza C, Persichilli S, Canu G, Gervasoni J, Torti E, Tazza L, et al. Measurement of 25- hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays. Clin Chem Lab Med 2012;50: 2033-5.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 2033-2035
    • Carrozza, C.1    Persichilli, S.2    Canu, G.3    Gervasoni, J.4    Torti, E.5    Tazza, L.6
  • 11
    • 84872927167 scopus 로고    scopus 로고
    • 25-hydroxyvitamin D testing: Challenging the performance of current immunoassays
    • Farrell CJ, Soldo J, Williams P, Herrmann M. 25-hydroxyvitamin D testing: challenging the performance of current immunoassays. Clin Chem Lab Med 2012;50:1953-63.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 1953-1963
    • Farrell, C.J.1    Soldo, J.2    Williams, P.3    Herrmann, M.4
  • 12
    • 84872903470 scopus 로고    scopus 로고
    • Analytical evaluation of a new automated protein binding assay to determine 25- hydroxyvitamin D concentrations
    • Franken WPJ, Vingerhoed J, Buijs MM. Analytical evaluation of a new automated protein binding assay to determine 25- hydroxyvitamin D concentrations. Clin Chem Lab Med 2012;50:2037-9.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 2037-2039
    • Franken, W.P.J.1    Vingerhoed, J.2    Buijs, M.M.3
  • 13
    • 79952801769 scopus 로고    scopus 로고
    • Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: An evaluation without spiked samples
    • Cavalier E, Wallace AM, Carlisi A, Chapelle JP, Delanaye P, Souberbielle JC. Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: an evaluation without spiked samples. Clin Chem Lab Med 2011;49:555 - 8.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 555-558
    • Cavalier, E.1    Wallace, A.M.2    Carlisi, A.3    Chapelle, J.P.4    Delanaye, P.5    Souberbielle, J.C.6
  • 14
    • 84857889828 scopus 로고    scopus 로고
    • Does the presence of 3-epi-25OHD3 affect the routine measurement of vitamin D using liquid chromatography tandem mass spectrometry ?
    • Keevil B. Does the presence of 3-epi-25OHD3 affect the routine measurement of vitamin D using liquid chromatography tandem mass spectrometry ? Clin Chem Lab Med 2012;50:181-3.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 181-183
    • Keevil, B.1
  • 15
    • 77749324101 scopus 로고    scopus 로고
    • Development of a candidate reference measurement procedure for the determination of 25- hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    • Tai SS, Bedner M, Phinney KW. Development of a candidate reference measurement procedure for the determination of 25- hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 2010;82:1942 - 8.
    • (2010) Anal Chem , vol.82 , pp. 1942-1948
    • Tai, S.S.1    Bedner, M.2    Phinney, K.W.3
  • 16
    • 79952205543 scopus 로고    scopus 로고
    • Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotopedilution liquid chromatography-tandem mass spectrometry
    • Stepman HC, Vanderroost A, Van Uytfanghe K, Thienpont LM. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotopedilution liquid chromatography-tandem mass spectrometry. Clin Chem 2011;57:441 - 8.
    • (2011) Clin Chem , vol.57 , pp. 441-448
    • Stepman, H.C.1    Vanderroost, A.2    Van Uytfanghe, K.3    Thienpont, L.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.