메뉴 건너뛰기




Volumn 50, Issue 11, 2012, Pages 2037-2039

Analytical evaluation of a new automated protein binding assay to determine 25-hydroxyvitamin D concentrations

Author keywords

25 Hydroxyvitamin D; Analytical validation; Liquid chromatography tandem mass spectrometry; Protein binding assay

Indexed keywords

25 HYDROXYVITAMIN D; VITAMIN D BINDING PROTEIN;

EID: 84872903470     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2012-0211     Document Type: Letter
Times cited : (1)

References (9)
  • 2
    • 77749324101 scopus 로고    scopus 로고
    • Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    • Thai SS, Bedner M, Phinney KW. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 2010;82:1942 - 8.
    • (2010) Anal Chem , vol.82 , pp. 1942-1948
    • Thai, S.S.1    Bedner, M.2    Phinney, K.W.3
  • 3
    • 79952205543 scopus 로고    scopus 로고
    • Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry
    • Stepman HC, Vanderroost A, Van UK, Thienpont LM. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 2011;57:441 - 8.
    • (2011) Clin Chem , vol.57 , pp. 441-448
    • Stepman, H.C.1    Vanderroost, A.2    Van, U.K.3    Thienpont, L.M.4
  • 4
    • 84857827503 scopus 로고    scopus 로고
    • Accuracy of 6 routine 25-hydroxyvitamin D assays; Influence of vitamin D binding protein concentration
    • [Epub ahead of print]. PMID: 22247500
    • Heijboer AC, Blankenstein MA, Kema IP, Buijs MM. Accuracy of 6 routine 25-hydroxyvitamin D assays; influence of vitamin D binding protein concentration. Clin Chem 2012 [Epub ahead of print]. PMID: 22247500.
    • (2012) Clin Chem
    • Heijboer, A.C.1    Blankenstein, M.A.2    Kema, I.P.3    Buijs, M.M.4
  • 5
    • 81155144796 scopus 로고    scopus 로고
    • Validatie van de iSYS (IDS) 25-hydroxyvitamine D-bepaling en vergelijking met vier andere 25-hydroxyvitamine D-meetmethoden
    • Rossum HH van, Buijs MM, Ouweland JM van den, Steen G. Validatie van de iSYS (IDS) 25-hydroxyvitamine D-bepaling en vergelijking met vier andere 25-hydroxyvitamine D-meetmethoden. Ned Tijdschr Klin Chem Labgeneesk 2011;36:267 - 9.
    • (2011) Ned Tijdschr Klin Chem Labgeneesk , vol.36 , pp. 267-269
    • Van Rossum, H.H.1    Buijs, M.M.2    Van Den Ouweland, J.M.3    Steen, G.4
  • 6
    • 77951097205 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitations
    • Wallace AM, Gibson S, de la Hunty A, Lamberg-Allardt C, Ashwell M. Measurement of 25-hydroxyvitamin D in the clinical laboratory: current procedures, performance characteristics and limitations. Steroids 2010;75:477 - 88.
    • (2010) Steroids , vol.75 , pp. 477-488
    • Wallace, A.M.1    Gibson, S.2    De La Hunty, A.3    Lamberg-Allardt, C.4    Ashwell, M.5
  • 7
    • 77955417271 scopus 로고    scopus 로고
    • Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry
    • Vogeser M. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry. J Steroid Biochem Mol Biol 2010;121:565 - 73.
    • (2010) J Steroid Biochem Mol Biol , vol.121 , pp. 565-573
    • Vogeser, M.1
  • 8
    • 42449115309 scopus 로고    scopus 로고
    • Vitamin D reinvented: Implications for clinical chemistry
    • Beastall G, Rainbow S. Vitamin D reinvented: implications for clinical chemistry. Clin Chem 2008;54:630 - 2.
    • (2008) Clin Chem , vol.54 , pp. 630-632
    • Beastall, G.1    Rainbow, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.