메뉴 건너뛰기




Volumn 15, Issue 1, 2013, Pages 37-48

A MEMS electrochemical bellows actuator for fluid metering applications

Author keywords

Fluid metering; MEMS electrochemical bellows actuators; Patient tailored site specific drug delivery devices; Wireless powering

Indexed keywords

APPLIED CURRENT; BACK PRESSURES; CLASS-D; DELIVERY PERFORMANCE; DRUG DELIVERY APPLICATIONS; DRUG DELIVERY DEVICES; EFFECTS OF TEMPERATURE; INDUCTIVE POWERING; PARYLENES; PT ELECTRODE; WIRELESS MEMS;

EID: 84872608420     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-012-9685-0     Document Type: Article
Times cited : (34)

References (37)
  • 1
    • 62249096225 scopus 로고    scopus 로고
    • Current micropump technologies and their biomedical applications
    • 10.1007/s00542-009-0804-7
    • F. Amirouche, Z. Yu et al., Current micropump technologies and their biomedical applications. Microsyst. Technol. 15(5), 647-666 (2009).
    • (2009) Microsyst. Technol. , vol.15 , Issue.5 , pp. 647-666
    • Amirouche, F.1    Yu, Z.2
  • 3
    • 0031078040 scopus 로고    scopus 로고
    • Oxygen and hydrogen permeation properties and water uptake of Nafion 117 membrane and recast film for PEM fuel cell
    • 10.1023/A:1018469520562 Copyright 1997, IEE
    • K. Broka, P. Ekdunge, Oxygen and hydrogen permeation properties and water uptake of Nafion 117 membrane and recast film for PEM fuel cell. J. Appl. Electrochem. 27, 117-123 (1997).
    • (1997) J. Appl. Electrochem. , vol.27 , pp. 117-123
    • Broka, K.1    Ekdunge, P.2
  • 4
    • 34948884624 scopus 로고    scopus 로고
    • Rhythmic pattern in pain and their chronotherapy
    • DOI 10.1016/j.addr.2006.06.001, PII S0169409X07001111, Chronobiology, Drug-delivery, and Chronotherapeutics
    • B. Bruguerolle, G. Labrecque, Rhythmic pattern in pain and their chronotherapy. Adv. Drug. Deliv. Rev. 59(9-10), 883-895 (2007). (Pubitemid 47531899)
    • (2007) Advanced Drug Delivery Reviews , vol.59 , Issue.9-10 , pp. 883-895
    • Bruguerolle, B.1    Labrecque, G.2
  • 7
    • 67349276971 scopus 로고    scopus 로고
    • Local drug delivery with a self-contained, programmable, microfluidic system
    • 10.1007/s10544-008-9265-5 Compendex
    • J. Fiering, M.J. Mescher et al., Local drug delivery with a self-contained, programmable, microfluidic system. Biomed. Microdevices. 11, 571-578 (2009).
    • (2009) Biomed. Microdevices. , vol.11 , pp. 571-578
    • Fiering, J.1    Mescher, M.J.2
  • 8
    • 84872595347 scopus 로고    scopus 로고
    • An implantable active microport based on a self-priming high-performance two-stage micropump
    • A. Geipel, F. Goldschmidtb, et al. (2008). "An implantable active microport based on a self-priming high-performance two-stage micropump." Sensors and Actuators A (Physical) 145-146.
    • (2008) Sensors and Actuators A (Physical) , pp. 145-146
    • Geipel, A.1    Goldschmidtb, F.2
  • 9
    • 80052122884 scopus 로고    scopus 로고
    • Rapid non-lithography based fabrication process and characterization of Parylene C bellows for applications in MEMS electrochemical actuators
    • Beijing, China
    • H. Gensler, R. Sheybani, et al. (2011). Rapid non-lithography based fabrication process and characterization of Parylene C bellows for applications in MEMS electrochemical actuators. 16th International Solid-State Sensors, Actuators and Microsystems Conference, Transducers '11, Beijing, China.
    • (2011) 16th International Solid-State Sensors, Actuators and Microsystems Conference, Transducers '11
    • Gensler, H.1    Sheybani, R.2
  • 10
    • 84861460408 scopus 로고    scopus 로고
    • An implantable MEMS micropump system for drug delivery in small animals
    • 10.1007/s10544-011-9625-4
    • H. Gensler, R. Sheybani et al., An implantable MEMS micropump system for drug delivery in small animals. Biomed. Microdevices. 14(3), 483-496 (2012).
    • (2012) Biomed. Microdevices. , vol.14 , Issue.3 , pp. 483-496
    • Gensler, H.1    Sheybani, R.2
  • 13
    • 21744440024 scopus 로고    scopus 로고
    • Design and test of a high-performance piezoelectric micropump for drug delivery
    • DOI 10.1016/j.sna.2004.12.002, PII S0924424704008581
    • K. Junwu, Z. Yang et al., Design and test of a high-performance piezoelectric micropump for drug delivery. Sensors. Actuators. A. Phys. 121, 156-161 (2005). (Pubitemid 40940795)
    • (2005) Sensors and Actuators, A: Physical , vol.121 , Issue.1 , pp. 156-161
    • Kan, J.1    Yang, Z.2    Peng, T.3    Cheng, G.4    Wu, B.5
  • 14
    • 33847309199 scopus 로고    scopus 로고
    • Micro system for injection of insulin and monitoring of glucose concentration
    • October 31 November 3, 2005 Irvine, CA, United states
    • A. Kabata, H. Suzuki, et al. (October 31, 2005 - November 3, 2005). Micro system for injection of insulin and monitoring of glucose concentration. Fourth IEEE Conference on Sensors, Irvine, CA, United states.
    • (2005) Fourth IEEE Conference on Sensors
    • Kabata, A.1    Suzuki, H.2
  • 15
    • 33750507126 scopus 로고    scopus 로고
    • Microemulsions as transdermal drug delivery vehicles
    • DOI 10.1016/j.cis.2006.05.014, PII S0001868606000650
    • A. Kogan, N. Garti, Microemulsions as transdermal drug delivery vehicles. Adv. Colloid. Interf. Sci. 123-126, 369-385 (2006). (Pubitemid 44665819)
    • (2006) Advances in Colloid and Interface Science , vol.123-126 , Issue.SPEC. ISS. , pp. 369-385
    • Kogan, A.1    Garti, N.2
  • 16
    • 3042553015 scopus 로고    scopus 로고
    • A review of micropumps
    • 10.1088/0960-1317/14/6/R01
    • D.J. Laser, J.G. Santiago, A review of micropumps. J. Micromech. Microeng. 14(6), 35-64 (2004).
    • (2004) J. Micromech. Microeng. , vol.14 , Issue.6 , pp. 35-64
    • Laser, D.J.1    Santiago, J.G.2
  • 17
    • 77951653761 scopus 로고    scopus 로고
    • Preparation and characterization of polymeric micelles consisting of poly(propylene glycol) and poly(caprolactone) as a drug carrier
    • Hongkong, China
    • S.H. Lee, J.M. Oh, et al. (2010). Preparation and characterization of polymeric micelles consisting of poly(propylene glycol) and poly(caprolactone) as a drug carrier. 2010 3rd International Nanoelectronics Conference, INEC 2010, Hongkong, China.
    • (2010) 2010 3rd International Nanoelectronics Conference, INEC 2010
    • Lee, S.H.1    Oh, J.M.2
  • 18
    • 76349121304 scopus 로고    scopus 로고
    • A parylene bellows electrochemical actuator
    • 10.1109/JMEMS.2009.2032670 Copyright 2010, The Institution of Engineering and Technology
    • P.-Y. Li, R. Sheybani et al., A parylene bellows electrochemical actuator. J. Microelectromech. Syst. 19, 215-228 (2010). Copyright 2010.
    • (2010) J. Microelectromech. Syst. , vol.19 , pp. 215-228
    • Li, P.-Y.1    Sheybani, R.2
  • 20
    • 85032558628 scopus 로고    scopus 로고
    • Partnership for Solutions: Better Lives for People with Chronic Conditions
    • Robert Wood Johnson Foundation
    • K. Menehan, (2006). Partnership for Solutions: Better Lives for People with Chronic Conditions. National Program Report. M. B. Janet Heroux, Robert Wood Johnson Foundation.
    • (2006) National Program Report. M. B. Janet Heroux
    • Menehan, K.1
  • 22
    • 0033736885 scopus 로고    scopus 로고
    • The electrolysis of water: An actuation principle for MEMS with a big opportunity
    • 10.1016/S0957-4158(99)00066-5 Copyright 2000, IEE
    • C. Neagu, H. Jansen et al., The electrolysis of water: an actuation principle for MEMS with a big opportunity. Mechatronics 10, 571-581 (2000).
    • (2000) Mechatronics , vol.10 , pp. 571-581
    • Neagu, C.1    Jansen, H.2
  • 24
    • 0021412248 scopus 로고
    • Gas permeation in spe method. i. Oxygen permeation through nafion and neosepta
    • Z. Ogumi, Z. Takehara et al., Gas Permeation in SPE Method I. oxygen permeation through Nafion and Neosepta. J. Electrochem. Soc. 131(4), 769-773 (1984). (Pubitemid 14544202)
    • (1984) Journal of the Electrochemical Society , vol.131 , Issue.4 , pp. 769-773
    • Ogumi, Z.1    Takehara, Z.2    Yoshizawa, S.3
  • 25
    • 0003974737 scopus 로고    scopus 로고
    • Supramolecular-structured polymers for drug delivery
    • 10.1021/bk-2000-0752.ch035 Compendex
    • T. Ooya, N. Yui, Supramolecular-structured polymers for drug delivery. ACS Symp. Ser. 752, 375-384 (2000).
    • (2000) ACS Symp. Ser. , vol.752 , pp. 375-384
    • Ooya, T.1    Yui, N.2
  • 26
    • 79953798413 scopus 로고    scopus 로고
    • High efficiency wireless electrochemical actuators: Design, fabrication and characterization by electrochemical impedance spectroscopy
    • Cancun, Mexico
    • R. Sheybani and E. Meng (2011). High efficiency wireless electrochemical actuators: Design, fabrication and characterization by electrochemical impedance spectroscopy. 24th IEEE International Conference on Micro Electro Mechanical Systems, MEMS '11, Cancun, Mexico.
    • (2011) 24th IEEE International Conference on Micro Electro Mechanical Systems, MEMS '11
    • Sheybani, R.1    Meng, E.2
  • 27
    • 84867097092 scopus 로고    scopus 로고
    • High Efficiency MEMS Electrochemical Actuators and Electrochemical Impedance Spectroscopy Characterization
    • (accepted))
    • Sheybani, R. and E. Meng (2012 (accepted)). "High Efficiency MEMS Electrochemical Actuators and Electrochemical Impedance Spectroscopy Characterization." IEEE Journal of Microelectromechanical Systems.
    • (2012) IEEE Journal of Microelectromechanical Systems
    • Sheybani, R.1    Meng, E.2
  • 30
    • 0017988537 scopus 로고
    • Supersaturation of oxygen in acidic solution in the vicinity of an oxygen-evolving platinum anode
    • DOI 10.1016/0013-4686(78)80090-5
    • S. Shibata, Supersaturation of oxygen in acidic solution in the vicinity of an oxygen-evolving platinum anode. Electrochim. Acta 23, 619-623 (1978). (Pubitemid 9386963)
    • (1978) Electrochimica Acta , vol.23 , Issue.7 , pp. 619-623
    • Shibata, S.1
  • 32
    • 0034272222 scopus 로고    scopus 로고
    • Microfabricated electrochemical actuator for large displacements
    • 10.1109/84.870057
    • T. Stanczyk, B. Ilic et al., Microfabricated electrochemical actuator for large displacements. J. Microelectromech. Syst. 9(3), 314-320 (2000).
    • (2000) J. Microelectromech. Syst. , vol.9 , Issue.3 , pp. 314-320
    • Stanczyk, T.1    Ilic, B.2
  • 33
    • 49149111795 scopus 로고    scopus 로고
    • Implementation of wireless power transfer and communications for an implantable ocular drug delivery system
    • 10.1049/iet-nbt:20080001
    • T.B. Tang, S. Smith et al., Implementation of wireless power transfer and communications for an implantable ocular drug delivery system. IET Nanobiotechnology. 2(3), 72-79 (2008).
    • (2008) IET Nanobiotechnology. , vol.2 , Issue.3 , pp. 72-79
    • Tang, T.B.1    Smith, S.2
  • 34
    • 33847359977 scopus 로고    scopus 로고
    • Review of MEMS-based drug delivery and dosing systems
    • DOI 10.1016/j.sna.2006.06.014, PII S0924424706004109
    • N.-C. Tsai, C.Y. Sue, Review of MEMS-based drug delivery and dosing systems. Sensors. Actuators. A. Phys. 134(2), 555-564 (2007). (Pubitemid 46349574)
    • (2007) Sensors and Actuators, A: Physical , vol.134 , Issue.2 , pp. 555-564
    • Tsai, N.-C.1    Sue, C.-Y.2
  • 36
    • 0030819320 scopus 로고    scopus 로고
    • Kinetic modelling of the hydrogen-oxygen reaction on Pt(111) at low temperature (<170 K)
    • PII S0039602896009764
    • L.K. Verheij, Kinetic modelling of the hydrogen-oxygen reaction on Pt(111) at low temperature (170K). Surf. Sci. 371(1), 100-110 (1997). (Pubitemid 127398472)
    • (1997) Surface Science , vol.371 , Issue.1 , pp. 100-110
    • Verheij, L.K.1
  • 37


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.