메뉴 건너뛰기




Volumn , Issue , 2011, Pages 337-367

Biotribocorrosion: Surface interactions in total joint replacement (TJR)

Author keywords

Biotribocorrosion; Load bearing joint replacement materials; Metal on metal; Orthopaedic implants; Total joint replacement (TJR); Tribology

Indexed keywords


EID: 84871755949     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-1-84569-966-6.50012-9     Document Type: Chapter
Times cited : (10)

References (111)
  • 10
    • 0037429943 scopus 로고    scopus 로고
    • Structural and mechanical properties of nanostructured metalloceramic coatings on cobalt chrome alloys
    • Catledge S.A., Vohra Y.K. Structural and mechanical properties of nanostructured metalloceramic coatings on cobalt chrome alloys. Applied Physics Letters 2003, 82:1625-1627.
    • (2003) Applied Physics Letters , vol.82 , pp. 1625-1627
    • Catledge, S.A.1    Vohra, Y.K.2
  • 11
    • 68949176195 scopus 로고    scopus 로고
    • Ceramics, glasses, and glass-ceramics
    • Elsevier Academic Press, London
    • Hench L.L., Best S. Ceramics, glasses, and glass-ceramics. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Hench, L.L.1    Best, S.2
  • 12
    • 0004064636 scopus 로고    scopus 로고
    • Professional Engineering Pubs, London
    • Dowson D. History of Tribology 1998, Professional Engineering Pubs, London.
    • (1998) History of Tribology
    • Dowson, D.1
  • 13
    • 33748874249 scopus 로고    scopus 로고
    • A history of biomaterials
    • Elsevier Academic Press, London
    • Ratner B.D. A history of biomaterials. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Ratner, B.D.1
  • 14
    • 84903425394 scopus 로고    scopus 로고
    • Degradative effects of the biological environment on metals and ceramics
    • Elsevier Academic Press, London
    • Williams D.F., Williams R.L. Degradative effects of the biological environment on metals and ceramics. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Williams, D.F.1    Williams, R.L.2
  • 15
    • 9144249321 scopus 로고    scopus 로고
    • Biomaterials in total joint replacement
    • Katti K.S. Biomaterials in total joint replacement. Colloids and Surfaces 2004, 39:133-142.
    • (2004) Colloids and Surfaces , vol.39 , pp. 133-142
    • Katti, K.S.1
  • 16
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - a materials science perspective
    • Long M., Rack H.J. Titanium alloys in total joint replacement - a materials science perspective. Biomaterials 1998, 19:1621-1639.
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 19
    • 0032818125 scopus 로고    scopus 로고
    • The influence of femoral head roughness on the wear of UHMWPE sockets in cementless total hip replacement
    • Elfick A.P.D., Pinder I.M., et al. The influence of femoral head roughness on the wear of UHMWPE sockets in cementless total hip replacement. Journal of Biomedical Materials Research 1999, 48:712-725.
    • (1999) Journal of Biomedical Materials Research , vol.48 , pp. 712-725
    • Elfick, A.P.D.1    Pinder, I.M.2
  • 20
    • 0034142667 scopus 로고    scopus 로고
    • Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: effects of counterpace material, contact area and lubricant
    • Saikko V., Ahlroos T. Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: effects of counterpace material, contact area and lubricant. Journal of Biomedical Materials Research 1999, 49:147-154.
    • (1999) Journal of Biomedical Materials Research , vol.49 , pp. 147-154
    • Saikko, V.1    Ahlroos, T.2
  • 21
    • 0042235809 scopus 로고    scopus 로고
    • Alternative materials to improve total hip replacement tribology
    • Santavirta S., Bohler M., Harris W.H., et al. Alternative materials to improve total hip replacement tribology. Acta Orthopaedica Scandinavica 2003, 74:380-388.
    • (2003) Acta Orthopaedica Scandinavica , vol.74 , pp. 380-388
    • Santavirta, S.1    Bohler, M.2    Harris, W.H.3
  • 22
    • 0033252596 scopus 로고    scopus 로고
    • A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    • Barbour P.S.M., Stone M.H., Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings of the Institution of Mechanical Engineers 1999, 213:455-467.
    • (1999) Proceedings of the Institution of Mechanical Engineers , vol.213 , pp. 455-467
    • Barbour, P.S.M.1    Stone, M.H.2    Fisher, J.3
  • 23
    • 33746356765 scopus 로고    scopus 로고
    • Surface modification of metals and alloys in a human body environment
    • Hanawa T., Hiromoto S. Surface modification of metals and alloys in a human body environment. Corrosion Engineering 1998, 47:895-907.
    • (1998) Corrosion Engineering , vol.47 , pp. 895-907
    • Hanawa, T.1    Hiromoto, S.2
  • 24
    • 0035482039 scopus 로고    scopus 로고
    • The acting wear mechanisms on metal-on-metal hip joint bearings: in vitro results
    • Wimmer M.A., Loos J., Nassutt R., Heitkemper M., Fischer A. The acting wear mechanisms on metal-on-metal hip joint bearings: in vitro results. Wear 2001, 250:129-139.
    • (2001) Wear , vol.250 , pp. 129-139
    • Wimmer, M.A.1    Loos, J.2    Nassutt, R.3    Heitkemper, M.4    Fischer, A.5
  • 25
    • 0016483665 scopus 로고
    • Cast vs wrought cobalt-chromium surgical implant alloys
    • Devine T.M., Wulff J. Cast vs wrought cobalt-chromium surgical implant alloys. Biomedical Materials 1974, 9:151-167.
    • (1974) Biomedical Materials , vol.9 , pp. 151-167
    • Devine, T.M.1    Wulff, J.2
  • 26
    • 0242607121 scopus 로고    scopus 로고
    • The electrochemical and mechanical behavior of passivated and TiN/AIN-coated CoCrMo and Ti6A14V alloys
    • Goldberg J.R., Glibert J.L. The electrochemical and mechanical behavior of passivated and TiN/AIN-coated CoCrMo and Ti6A14V alloys. Biomaterials 2004, 25:851-864.
    • (2004) Biomaterials , vol.25 , pp. 851-864
    • Goldberg, J.R.1    Glibert, J.L.2
  • 27
    • 2342593395 scopus 로고    scopus 로고
    • Influence of fretting regimes on the tribocorrosion behavious of Ti6A14V in 0.9wt.% sodium chloride solution
    • Barril S., Mischler S., Landolt D. Influence of fretting regimes on the tribocorrosion behavious of Ti6A14V in 0.9wt.% sodium chloride solution. Wear 2004, 256:963-972.
    • (2004) Wear , vol.256 , pp. 963-972
    • Barril, S.1    Mischler, S.2    Landolt, D.3
  • 28
    • 84860747901 scopus 로고    scopus 로고
    • Effect of albumin on fretting-corrosion mechanism of a Ti-Al-V Alloy
    • Hiromoto S., Mischler S. Effect of albumin on fretting-corrosion mechanism of a Ti-Al-V Alloy. European Cells and Materials 2004, 7:40-41.
    • (2004) European Cells and Materials , vol.7 , pp. 40-41
    • Hiromoto, S.1    Mischler, S.2
  • 29
    • 0037290074 scopus 로고    scopus 로고
    • Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
    • Germain M.A., Hatton A., Williams S., Matthews J.B., Stone M.H., Fisher J., Ingham E. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials 2003, 24:469-479.
    • (2003) Biomaterials , vol.24 , pp. 469-479
    • Germain, M.A.1    Hatton, A.2    Williams, S.3    Matthews, J.B.4    Stone, M.H.5    Fisher, J.6    Ingham, E.7
  • 30
    • 38749098531 scopus 로고    scopus 로고
    • Wear and functional biological activity of wear debris generated from UHMWPE-on-zirconia ceramic, metal-on-metal, and aalumnia ceramic-on ceramic hip prostheses during hip simulator testing
    • Profession Engineering Publishing, London
    • Tipper J.L., Matthews J.B., Ingham E., Stewart T.D., Fisher J. Wear and functional biological activity of wear debris generated from UHMWPE-on-zirconia ceramic, metal-on-metal, and aalumnia ceramic-on ceramic hip prostheses during hip simulator testing. Friction, Lubrication and Wear of Artificial Joints 2003, Profession Engineering Publishing, London.
    • (2003) Friction, Lubrication and Wear of Artificial Joints
    • Tipper, J.L.1    Matthews, J.B.2    Ingham, E.3    Stewart, T.D.4    Fisher, J.5
  • 31
    • 0028533512 scopus 로고
    • Detection of antibodies against corrosion products in patients Co-Cr total joint replacement
    • Yang J., Meritt K. Detection of antibodies against corrosion products in patients Co-Cr total joint replacement. Journal of Biomedical Materials Research 1994, 28:1249-1258.
    • (1994) Journal of Biomedical Materials Research , vol.28 , pp. 1249-1258
    • Yang, J.1    Meritt, K.2
  • 32
    • 0036899174 scopus 로고    scopus 로고
    • Evaluation techniques of metallic biomaterials in vitro
    • Hanawa T. Evaluation techniques of metallic biomaterials in vitro. Science and Technology of Advanced Materials 2002, 3:289-295.
    • (2002) Science and Technology of Advanced Materials , vol.3 , pp. 289-295
    • Hanawa, T.1
  • 36
    • 0017956442 scopus 로고
    • Pitting resistance of new and conventional orthopedic implant materials - effect of metallurgical condition
    • Syrett B.C., Wing S.S. Pitting resistance of new and conventional orthopedic implant materials - effect of metallurgical condition. Corrosion Nace 1978, 34:138-145.
    • (1978) Corrosion Nace , vol.34 , pp. 138-145
    • Syrett, B.C.1    Wing, S.S.2
  • 37
  • 39
    • 4844229221 scopus 로고    scopus 로고
    • In vitro biocorrosion of CoCrMo implant alloy by macrophage cells
    • Lin J.Y., Bumgardner J.D. In vitro biocorrosion of CoCrMo implant alloy by macrophage cells. Journal of Orthopaedic Research 2004, 22:1231-1236.
    • (2004) Journal of Orthopaedic Research , vol.22 , pp. 1231-1236
    • Lin, J.Y.1    Bumgardner, J.D.2
  • 40
    • 20344371942 scopus 로고    scopus 로고
    • Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum
    • Contu F., Elsener B., Bohni H. Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum. Corrosion Science 2004, 47:1863-1875.
    • (2004) Corrosion Science , vol.47 , pp. 1863-1875
    • Contu, F.1    Elsener, B.2    Bohni, H.3
  • 42
    • 0019449758 scopus 로고
    • Corrosion of Co-Cr alloys in aqueous environments
    • Kuhn A.T. Corrosion of Co-Cr alloys in aqueous environments. Biomaterials 1981, 2:68-77.
    • (1981) Biomaterials , vol.2 , pp. 68-77
    • Kuhn, A.T.1
  • 43
    • 0033118784 scopus 로고    scopus 로고
    • Conjoint corrosion and wear in titanium alloys
    • Khan M.A., Williams R.L., Williams D.F. Conjoint corrosion and wear in titanium alloys. Biomaterials 1999, 20:762-772.
    • (1999) Biomaterials , vol.20 , pp. 762-772
    • Khan, M.A.1    Williams, R.L.2    Williams, D.F.3
  • 44
    • 0012560617 scopus 로고    scopus 로고
    • Wear-corrosion of nitrided steel: corrosion potential monitoring to evaluate the effect of test parameters
    • Rossi S., Fedrizzi L., Deflorian F., Zen M. Wear-corrosion of nitrided steel: corrosion potential monitoring to evaluate the effect of test parameters. Materials and Corrosion 2000, 51:552-556.
    • (2000) Materials and Corrosion , vol.51 , pp. 552-556
    • Rossi, S.1    Fedrizzi, L.2    Deflorian, F.3    Zen, M.4
  • 46
    • 0000004348 scopus 로고    scopus 로고
    • Corrosion Measurements of Biomedical Metallic Materials
    • Hanawa T. Corrosion Measurements of Biomedical Metallic Materials. Corrosion Engineering 2000, 49:687-699.
    • (2000) Corrosion Engineering , vol.49 , pp. 687-699
    • Hanawa, T.1
  • 47
    • 0031555492 scopus 로고    scopus 로고
    • Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch
    • Goldberg J.R., Gilbert J.L. Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch. Journal of Biomedical Materials Research 1997, 37:421-431.
    • (1997) Journal of Biomedical Materials Research , vol.37 , pp. 421-431
    • Goldberg, J.R.1    Gilbert, J.L.2
  • 49
    • 33646044004 scopus 로고    scopus 로고
    • Orthopaedic applications
    • Elsevier Academic Press, London
    • Hallab N.J., Jacobs J.J. Orthopaedic applications. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Hallab, N.J.1    Jacobs, J.J.2
  • 50
    • 84903425396 scopus 로고    scopus 로고
    • Systemic toxicity and hypersensitivity
    • Elsevier Academic Press, London
    • Hensten-Pettersen A., Jacobsen N. Systemic toxicity and hypersensitivity. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Hensten-Pettersen, A.1    Jacobsen, N.2
  • 52
    • 0034777364 scopus 로고    scopus 로고
    • Reference values for trace and ultratrace elements in human serum determined by doublefocusing ICP-MS
    • Muniz C.S., Fernandez-Martin J.L., et al. Reference values for trace and ultratrace elements in human serum determined by doublefocusing ICP-MS. Biological Trace Element Research 2001, 82:259-269.
    • (2001) Biological Trace Element Research , vol.82 , pp. 259-269
    • Muniz, C.S.1    Fernandez-Martin, J.L.2
  • 53
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study
    • Black J., Maitin E.C., Gelman H., Morris D.M. Serum concentrations of chromium, cobalt and nickel after total hip replacement: a six month study. Biomaterials 1983, 4:160-164.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3    Morris, D.M.4
  • 54
    • 0025963553 scopus 로고
    • Cancer risk after McKee total hip replacement
    • Visuri T., Koskenvuo M. Cancer risk after McKee total hip replacement. Orthopedics 1991, 14:137-142.
    • (1991) Orthopedics , vol.14 , pp. 137-142
    • Visuri, T.1    Koskenvuo, M.2
  • 55
  • 56
    • 84903425397 scopus 로고
    • Release of corrosion products by F-75 cobalt base alloy in the rat. I: Acute serum elevations
    • Koegel A., Black J. Release of corrosion products by F-75 cobalt base alloy in the rat. I: Acute serum elevations. Society for Biomaterials 1983.
    • (1983) Society for Biomaterials
    • Koegel, A.1    Black, J.2
  • 57
    • 0020456135 scopus 로고
    • Electrochemical study of corrosion in Ni-Cr dental alloys
    • Micheli S.M.D.D., Riesgo O. Electrochemical study of corrosion in Ni-Cr dental alloys. Biomaterials 1982, 3:209-212.
    • (1982) Biomaterials , vol.3 , pp. 209-212
    • Micheli, S.M.D.D.1    Riesgo, O.2
  • 58
    • 0032126428 scopus 로고    scopus 로고
    • A multidirectional motion pin-on-disk wear test method for prosthetic joint materials
    • Saikko V. A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. Journal of Biomedical Materials Research 1998, 41:58-64.
    • (1998) Journal of Biomedical Materials Research , vol.41 , pp. 58-64
    • Saikko, V.1
  • 59
    • 0020072025 scopus 로고
    • Wear studies on prosthetic materials using the pin-on-disc machine
    • Wright K.W.J., Dobbs H.S., Scales J.T. Wear studies on prosthetic materials using the pin-on-disc machine. Biomaterials 1982, 3:41-48.
    • (1982) Biomaterials , vol.3 , pp. 41-48
    • Wright, K.W.J.1    Dobbs, H.S.2    Scales, J.T.3
  • 60
    • 0006097153 scopus 로고
    • The influence of composition, phase transformation and varying the relative f.c.c. and h.c.p. phase contents on the properties of Co-W-C alloys
    • Roebuck B., Almond E.A. The influence of composition, phase transformation and varying the relative f.c.c. and h.c.p. phase contents on the properties of Co-W-C alloys. Materials Science and Engineering 1984, 66:179-194.
    • (1984) Materials Science and Engineering , vol.66 , pp. 179-194
    • Roebuck, B.1    Almond, E.A.2
  • 61
    • 3042786380 scopus 로고    scopus 로고
    • Cobalt-based alloys for orthopaedic applications studies by electrochemical and XPS analysis
    • Kocijan A., Milosev I., Pihlar B. Cobalt-based alloys for orthopaedic applications studies by electrochemical and XPS analysis. Materials in Medicine 2004, 15:643-650.
    • (2004) Materials in Medicine , vol.15 , pp. 643-650
    • Kocijan, A.1    Milosev, I.2    Pihlar, B.3
  • 63
    • 0037007468 scopus 로고    scopus 로고
    • Protein stability: the value of 'old literature
    • Franks F. Protein stability: the value of 'old literature. Biophysical Chemistry 2002, 117-127.
    • (2002) Biophysical Chemistry , pp. 117-127
    • Franks, F.1
  • 64
    • 0034233158 scopus 로고    scopus 로고
    • Wear in relation to friction - a review
    • Kato K. Wear in relation to friction - a review. Wear 2000, 241:151-157.
    • (2000) Wear , vol.241 , pp. 151-157
    • Kato, K.1
  • 66
    • 0345688121 scopus 로고    scopus 로고
    • Changes in the surface oxide composition of Co-Cr-Mo implant alloy by macrophage cells and their released reactive chemical species
    • Lin H.-Y., Bumgardner J.D. Changes in the surface oxide composition of Co-Cr-Mo implant alloy by macrophage cells and their released reactive chemical species. Biomaterials 2004, 25:1233-1238.
    • (2004) Biomaterials , vol.25 , pp. 1233-1238
    • Lin, H.-Y.1    Bumgardner, J.D.2
  • 67
    • 0042021516 scopus 로고    scopus 로고
    • A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty
    • Cawley J., Metcalf J.E.P., Jones A.H., Band T.J., Skupien D.S. A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty. Wear 2003, 255:999-1006.
    • (2003) Wear , vol.255 , pp. 999-1006
    • Cawley, J.1    Metcalf, J.E.P.2    Jones, A.H.3    Band, T.J.4    Skupien, D.S.5
  • 68
    • 9644273921 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joint Part I: The role of materials
    • Dowson D., Hardaker C., Flett M., Isaac G.H. A hip joint simulator study of the performance of metal-on-metal joint Part I: The role of materials. Arthroplasty 2004, 19:124-130.
    • (2004) Arthroplasty , vol.19 , pp. 124-130
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.H.4
  • 69
    • 0031686498 scopus 로고    scopus 로고
    • Effect of femoral head surface roughness on the wear of UHMWPE acetabular cups
    • Wang A., Polineni V.K., et al. Effect of femoral head surface roughness on the wear of UHMWPE acetabular cups. Journal of Arthroplasty 1998, 13:615-625.
    • (1998) Journal of Arthroplasty , vol.13 , pp. 615-625
    • Wang, A.1    Polineni, V.K.2
  • 70
    • 0034565054 scopus 로고    scopus 로고
    • Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement
    • Jin Z.M., Firkins P., Farrar R., Fisher J. Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement. Proceedings of the Institution of Mechanical Engineers H 2000, 214:559-568.
    • (2000) Proceedings of the Institution of Mechanical Engineers H , vol.214 , pp. 559-568
    • Jin, Z.M.1    Firkins, P.2    Farrar, R.3    Fisher, J.4
  • 71
    • 0030810504 scopus 로고    scopus 로고
    • Friction in hip prostheses
    • Hall R.M., Unsworth A. Friction in hip prostheses. Biomaterials 1997, 18:1017-1026.
    • (1997) Biomaterials , vol.18 , pp. 1017-1026
    • Hall, R.M.1    Unsworth, A.2
  • 72
    • 0032523851 scopus 로고    scopus 로고
    • Effect of counterface surface roughness and its evolution on the wear and friction of PEEK and PEEK-bonded carbon fibre composites on stainless steel
    • Elliott D.M., Fisher J., Clark D.T. Effect of counterface surface roughness and its evolution on the wear and friction of PEEK and PEEK-bonded carbon fibre composites on stainless steel. Wear 1998, 217:288-296.
    • (1998) Wear , vol.217 , pp. 288-296
    • Elliott, D.M.1    Fisher, J.2    Clark, D.T.3
  • 73
    • 0035116948 scopus 로고    scopus 로고
    • Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion
    • Hallab N.J., Bundy K., O'Connor K., Moses R., Jacobs J. Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion. Tissue Engineering 2001, 7:55-68.
    • (2001) Tissue Engineering , vol.7 , pp. 55-68
    • Hallab, N.J.1    Bundy, K.2    O'Connor, K.3    Moses, R.4    Jacobs, J.5
  • 74
    • 0028262845 scopus 로고
    • Friction and wear changes in synovial joints
    • Stachowiak G.W., Batchelor A.W., Griffiths L.J. Friction and wear changes in synovial joints. Wear 1994, 171:135-142.
    • (1994) Wear , vol.171 , pp. 135-142
    • Stachowiak, G.W.1    Batchelor, A.W.2    Griffiths, L.J.3
  • 77
    • 9644287859 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joint Part II: Design
    • Dowson D., Hardaker C., Flett M., Isaac G.H. A hip joint simulator study of the performance of metal-on-metal joint Part II: Design. Arthroplasty 2004, 19:118-123.
    • (2004) Arthroplasty , vol.19 , pp. 118-123
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.H.4
  • 78
    • 0041627840 scopus 로고    scopus 로고
    • The effect of mechanical and electrochemical parameters on the tribocorrosion rate of stainless steel in sulphuric acid
    • Stemp M., Mischler S., Landolt D. The effect of mechanical and electrochemical parameters on the tribocorrosion rate of stainless steel in sulphuric acid. Wear 2003, 255:466-475.
    • (2003) Wear , vol.255 , pp. 466-475
    • Stemp, M.1    Mischler, S.2    Landolt, D.3
  • 79
    • 84903425398 scopus 로고
    • Running in processes affecting friction and wear
    • Butterworth & Co Ltd, Surrey
    • Heilmann P., Rigney D.S. Running in processes affecting friction and wear. The Running-in Process in Tribology 1981, Butterworth & Co Ltd, Surrey.
    • (1981) The Running-in Process in Tribology
    • Heilmann, P.1    Rigney, D.S.2
  • 80
    • 84903425392 scopus 로고
    • On the initial stages of wear of dry-bearing composites
    • Butterworth & Co Ltd, Surrey
    • Lancaster J.K. On the initial stages of wear of dry-bearing composites. The Running-in Process in Tribology 1981, Butterworth & Co Ltd, Surrey.
    • (1981) The Running-in Process in Tribology
    • Lancaster, J.K.1
  • 81
    • 0022994543 scopus 로고
    • Properties of biomaterials
    • Lemons J.E., Lucas L.C. Properties of biomaterials. Arthroplasty 1986, 1:143-147.
    • (1986) Arthroplasty , vol.1 , pp. 143-147
    • Lemons, J.E.1    Lucas, L.C.2
  • 83
    • 4344667565 scopus 로고    scopus 로고
    • Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model
    • Onishi H., Clarke I.C., Good V., Amino H., Ueno M. Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model. Journal of Biomedical Materials Research A 2004, 70:523-532.
    • (2004) Journal of Biomedical Materials Research A , vol.70 , pp. 523-532
    • Onishi, H.1    Clarke, I.C.2    Good, V.3    Amino, H.4    Ueno, M.5
  • 84
    • 0020111776 scopus 로고
    • The effects of proteins on metallic corrosion
    • Clark G.C.F., Williams D.F. The effects of proteins on metallic corrosion. Biomedical Materials 1982, 16:125-134.
    • (1982) Biomedical Materials , vol.16 , pp. 125-134
    • Clark, G.C.F.1    Williams, D.F.2
  • 85
    • 73149114705 scopus 로고    scopus 로고
    • Stability and repassivation of metallic implants in serum bovine
    • Contu F., Elsener B., Bohni H. Stability and repassivation of metallic implants in serum bovine. European Cells and Materials 2001, 1:14-15.
    • (2001) European Cells and Materials , vol.1 , pp. 14-15
    • Contu, F.1    Elsener, B.2    Bohni, H.3
  • 87
    • 0023927721 scopus 로고
    • Orientation of the water molecules of hydration of human serum albumin
    • Oss C.J.V., Good R.J. Orientation of the water molecules of hydration of human serum albumin. Journal of Protein Chemistry 1988, 7:179-183.
    • (1988) Journal of Protein Chemistry , vol.7 , pp. 179-183
    • Oss, C.J.V.1    Good, R.J.2
  • 91
    • 0030210397 scopus 로고    scopus 로고
    • Comparison of alloys and designs in a simulator study of metal on metal implants
    • Medley J.B. Comparison of alloys and designs in a simulator study of metal on metal implants. Clinical Orthopaedics and Related Research 1996, 329S:148-159.
    • (1996) Clinical Orthopaedics and Related Research , vol.329 S , pp. 148-159
    • Medley, J.B.1
  • 92
    • 4243320939 scopus 로고    scopus 로고
    • The tribology (friction, lubrication and wear) of all-metal artificial hip joints
    • Walker P.S., Gold B.I. The tribology (friction, lubrication and wear) of all-metal artificial hip joints. Clinical Orthopaedics and Related Research 1996, 329S:4-10.
    • (1996) Clinical Orthopaedics and Related Research , vol.329 S , pp. 4-10
    • Walker, P.S.1    Gold, B.I.2
  • 93
    • 0033303825 scopus 로고    scopus 로고
    • Characteristics of copper corrosion in simulated uterine fluid in the presence of protein
    • Zhu J., Xu N., Zhang C. Characteristics of copper corrosion in simulated uterine fluid in the presence of protein. Advances in Contraception 1999, 15:179-190.
    • (1999) Advances in Contraception , vol.15 , pp. 179-190
    • Zhu, J.1    Xu, N.2    Zhang, C.3
  • 94
    • 26844456714 scopus 로고    scopus 로고
    • The role of adsorbed proteins in tissue response to biomaterials
    • Elsevier Academic Press, London
    • Horbett T.A. The role of adsorbed proteins in tissue response to biomaterials. Biomaterials Science 2004, Elsevier Academic Press, London.
    • (2004) Biomaterials Science
    • Horbett, T.A.1
  • 95
    • 0026410002 scopus 로고
    • Structural aspects of metal liganding to functional groups of proteins
    • Glusker J.P. Structural aspects of metal liganding to functional groups of proteins. Advances in protein 1991.
    • (1991) Advances in protein
    • Glusker, J.P.1
  • 97
    • 0000099624 scopus 로고    scopus 로고
    • Biological surface science
    • Kasemo B. Biological surface science. Materials Science 1998, 3:451-459.
    • (1998) Materials Science , vol.3 , pp. 451-459
    • Kasemo, B.1
  • 98
    • 0032048252 scopus 로고    scopus 로고
    • Study of glycine adsorption on a Cu surface using reflection absorption infrared spectroscopy
    • Barlow S.M., Krozer K.J., et al. Study of glycine adsorption on a Cu surface using reflection absorption infrared spectroscopy. Surface Science 1998, 401:322-335.
    • (1998) Surface Science , vol.401 , pp. 322-335
    • Barlow, S.M.1    Krozer, K.J.2
  • 99
    • 0020716183 scopus 로고
    • Protein adsorption and desoption phenomena on clean metal surfaces
    • WIlliams D.F., Askill I.N., Smith R. Protein adsorption and desoption phenomena on clean metal surfaces. Biomedical Materials 1985, 19:313-320.
    • (1985) Biomedical Materials , vol.19 , pp. 313-320
    • Williams, D.F.1    Askill, I.N.2    Smith, R.3
  • 100
    • 4644370329 scopus 로고    scopus 로고
    • E Zobeley, R. Glockshuber and N. D. Spencer, Protein-mediated boundary lubrication in arthroplasty
    • Heuberger M.P., Widmer M.R. E Zobeley, R. Glockshuber and N. D. Spencer, Protein-mediated boundary lubrication in arthroplasty. Biomaterials 2005, 26:1165-1173.
    • (2005) Biomaterials , vol.26 , pp. 1165-1173
    • Heuberger, M.P.1    Widmer, M.R.2
  • 102
    • 0021321419 scopus 로고
    • Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty
    • Amstutz H.C., Thomas B.J., Jinnah R. Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty. Journal of Bone joint Surgery 1984, 66:228-241.
    • (1984) Journal of Bone joint Surgery , vol.66 , pp. 228-241
    • Amstutz, H.C.1    Thomas, B.J.2    Jinnah, R.3
  • 103
    • 0023899327 scopus 로고
    • Albumin adsorption on metal surfaces
    • Williams R.L., Williams D.F. Albumin adsorption on metal surfaces. Biomaterials 1988, 9:206-212.
    • (1988) Biomaterials , vol.9 , pp. 206-212
    • Williams, R.L.1    Williams, D.F.2
  • 104
    • 0023866875 scopus 로고
    • Electrochemical studies on the influence of proteins on the corrosion of implant alloys
    • Williams R.L., Brown S.A., Merritt K. Electrochemical studies on the influence of proteins on the corrosion of implant alloys. Biomaterials 1988, 9:181-186.
    • (1988) Biomaterials , vol.9 , pp. 181-186
    • Williams, R.L.1    Brown, S.A.2    Merritt, K.3
  • 105
    • 0033120166 scopus 로고    scopus 로고
    • The corrosion behaviour of Ti-6A1-4 V, Ti-6A1-7Nb and Ti-13Nb-13Zr in protein solutions
    • Khan M.A., Williams R.L., Williams D.F. The corrosion behaviour of Ti-6A1-4 V, Ti-6A1-7Nb and Ti-13Nb-13Zr in protein solutions. Biomaterials 1999, 20:631-637.
    • (1999) Biomaterials , vol.20 , pp. 631-637
    • Khan, M.A.1    Williams, R.L.2    Williams, D.F.3
  • 106
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt chromium wear and corrosion productions and biological reactions
    • Merritt K., Brown S.A. Distribution of cobalt chromium wear and corrosion productions and biological reactions. Clinical Orthopaedics and Related Research 1996, 329S:233-243.
    • (1996) Clinical Orthopaedics and Related Research , vol.329 S , pp. 233-243
    • Merritt, K.1    Brown, S.A.2
  • 107
    • 84903425386 scopus 로고    scopus 로고
    • An innovative method based on the difference of material wettability to gain an efficient lubricant condition
    • Kobe
    • Adelina B. An innovative method based on the difference of material wettability to gain an efficient lubricant condition. Synopses of the International Tribology 2005, Kobe.
    • (2005) Synopses of the International Tribology
    • Adelina, B.1
  • 108
    • 4444251742 scopus 로고    scopus 로고
    • The protective nature of passivation films on zinc: wetting and surface energy
    • Muster T.H., Neufeld A.K., Cole I.S. The protective nature of passivation films on zinc: wetting and surface energy. Corrosion Science 2004, 46:2337-2354.
    • (2004) Corrosion Science , vol.46 , pp. 2337-2354
    • Muster, T.H.1    Neufeld, A.K.2    Cole, I.S.3
  • 109
    • 0022024864 scopus 로고
    • Adsorption of proteins on metal surfaces studied by ellipsometric and capacitance measurements
    • Ivarsson B.A., Hegg P.-O., Lundstrom K.I., Jonsson U. Adsorption of proteins on metal surfaces studied by ellipsometric and capacitance measurements. Colloids and Surfaces 1985, 13:169-192.
    • (1985) Colloids and Surfaces , vol.13 , pp. 169-192
    • Ivarsson, B.A.1    Hegg, P.-O.2    Lundstrom, K.I.3    Jonsson, U.4
  • 110
    • 16244399170 scopus 로고    scopus 로고
    • Surface enhanced Raman scattering from bare cobalt electrode surfaces
    • Wu D.Y., Xie Y., et al. Surface enhanced Raman scattering from bare cobalt electrode surfaces. Physchem Comm 2001, 18:1-13.
    • (2001) Physchem Comm , vol.18 , pp. 1-13
    • Wu, D.Y.1    Xie, Y.2
  • 111
    • 0141464869 scopus 로고    scopus 로고
    • Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: Metal release and biofilm formation
    • Hallab N.J., Skipor A., Jacobs J. Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: Metal release and biofilm formation. Journal of Biomedical Materials Research Part A 2003, 65:311-318.
    • (2003) Journal of Biomedical Materials Research Part A , vol.65 , pp. 311-318
    • Hallab, N.J.1    Skipor, A.2    Jacobs, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.