Volumn 49, Issue 2, 2000, Pages 147-154

Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: Effects of counterface material, contact area, and lubricant

Author keywords

Albumin; Gamma globulin; Polyethylene; Total hip prosthesis; Wear simulation

Indexed keywords

ALUMINA; HIP PROSTHESES; LUBRICANTS; PROTEINS; STAINLESS STEEL; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 0034142667     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(200002)49:2<147::AID-JBM1>3.0.CO;2-H     Document Type: Article
Times cited : (66)

References (24)
  • 1
    • 0018034893 scopus 로고
    • Wear characteristics of UHMW polyethylene: A method for accurately measuring extremely low wear rates
    • McKellop H, Clarke IC, Markolf KL, Amstutz HC. Wear characteristics of UHMW polyethylene: A method for accurately measuring extremely low wear rates. J Biomed Mater Res 1978; 12:895-927.
    • (1978) J Biomed Mater Res , vol.12 , pp. 895-927
    • McKellop, H.1    Clarke, I.C.2    Markolf, K.L.3    Amstutz, H.C.4
  • 2
    • 0022188512 scopus 로고
    • Influence of counterface topography on the wear of ultra high molecular weight polyethylene under wet or dry conditions
    • Lee L-H, editor. Washington, DC: American Chemical Society
    • Dowson D, El-Hady Diab MM, Gillis BJ, Atkinson JR. Influence of counterface topography on the wear of ultra high molecular weight polyethylene under wet or dry conditions. In: Lee L-H, editor. Polymer wear and its control. Washington, DC: American Chemical Society; 1985. p 171-187.
    • (1985) Polymer Wear and Its Control , pp. 171-187
    • Dowson, D.1    El-Hady Diab, M.M.2    Gillis, B.J.3    Atkinson, J.R.4
  • 3
    • 0022615189 scopus 로고
    • The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethylene
    • Weightman B, Light D. The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethylene. Biomaterials 1986;7:20-24.
    • (1986) Biomaterials , vol.7 , pp. 20-24
    • Weightman, B.1    Light, D.2
  • 4
    • 0027627370 scopus 로고
    • Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatus
    • Saikko V. Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatus. Wear 1993;166:169-178.
    • (1993) Wear , vol.166 , pp. 169-178
    • Saikko, V.1
  • 5
    • 0022108298 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III. The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors
    • Atkinson JR, Dowson D, Wroblewski BM. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III. The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors. Wear 1985;104:225-244.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Wroblewski, B.M.3
  • 10
    • 0032126428 scopus 로고    scopus 로고
    • A multidirectional motion pin-on-disk wear test method for prosthetic joint materials
    • Saikko V. A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. J Biomed Mater Res 1998; 41:58-64.
    • (1998) J Biomed Mater Res , vol.41 , pp. 58-64
    • Saikko, V.1
  • 11
    • 0032616832 scopus 로고    scopus 로고
    • Type of motion and lubricant in wear simulation of polyethylene acetabular cup
    • Saikko V, Ahlroos T. Type of motion and lubricant in wear simulation of polyethylene acetabular cup. J Eng Med. 1999;213:301-310.
    • (1999) J Eng Med. , vol.213 , pp. 301-310
    • Saikko, V.1    Ahlroos, T.2
  • 12
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • Wang A, Stark C, Dumbleton JH. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. J Eng Med 1996;210:141-155.
    • (1996) J Eng Med , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 13
    • 0030625737 scopus 로고    scopus 로고
    • Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear
    • Clarke IC, Good V, Anissian L, Gustafson A. Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear. J Eng Med 1997;211:25-36.
    • (1997) J Eng Med , vol.211 , pp. 25-36
    • Clarke, I.C.1    Good, V.2    Anissian, L.3    Gustafson, A.4
  • 14
    • 0030623710 scopus 로고    scopus 로고
    • Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant
    • Bigsby RJA, Hardaker CS, Fisher J. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. J Eng Med 1996;211:265-269.
    • (1996) J Eng Med , vol.211 , pp. 265-269
    • Bigsby, R.J.A.1    Hardaker, C.S.2    Fisher, J.3
  • 18
    • 0030625634 scopus 로고    scopus 로고
    • Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements
    • Semlitsch M, Willert HG. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. J Eng Med 1997;211:73-88.
    • (1997) J Eng Med , vol.211 , pp. 73-88
    • Semlitsch, M.1    Willert, H.G.2
  • 20
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 1990;72-A:518-528.
    • (1990) J Bone Joint Surg , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 22
    • 0019631987 scopus 로고
    • In vivo hip joint forces recorded on a strain gauged "English" prosthesis using an implanted transmitter
    • Kilvington M, Goodman RMF. In vivo hip joint forces recorded on a strain gauged "English" prosthesis using an implanted transmitter. Eng Med 1981;10:175-187.
    • (1981) Eng Med , vol.10 , pp. 175-187
    • Kilvington, M.1    Goodman, R.M.F.2
  • 23
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech 1993;26:969-990.
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 24
    • 0016942059 scopus 로고
    • The wear of plastics materials in the hip joint
    • Charnley J. The wear of plastics materials in the hip joint. Plast and Rub 1976;1:59-63.
    • (1976) Plast and Rub , vol.1 , pp. 59-63
    • Charnley, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.