Volumn 20, Issue 7, 1999, Pages 631-637

The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions

Author keywords

Corrosion; Mechanical properties

Indexed keywords

CORROSION RESISTANCE; HARDNESS; PH EFFECTS; PROTEINS; SOLUTIONS; SURFACE PROPERTIES; TITANIUM ALLOYS; WEAR OF MATERIALS;

EID: 0033120166     PISSN: 01429612     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-9612(98)00217-8     Document Type: Article
Times cited : (470)

References (13)
  • 1
    • 0015338068 scopus 로고
    • Corrosion of Ti-6Al-4V in simulated body fluids and bovine plasma
    • [1] Aragon PJ, Hulbert SF, Corrosion of Ti-6Al-4V in simulated body fluids and bovine plasma. J Biomed Mater Res 1972;6:155-164.
    • (1972) J Biomed Mater Res , vol.6 , pp. 155-164
    • Aragon, P.J.1    Hulbert, S.F.2
  • 2
    • 0014747184 scopus 로고
    • Polarization studies of surgical materials in Ringers solution
    • [2] Mueller HJ, Greener EH, Polarization studies of surgical materials in Ringers solution. J Biomed Mater Res 1970;4:29-41.
    • (1970) J Biomed Mater Res , vol.4 , pp. 29-41
    • Mueller, H.J.1    Greener, E.H.2
  • 3
    • 0024059621 scopus 로고
    • Does corrosion matter?
    • [3] Black J. Does corrosion matter? J Bone and Jt Surg 1988;70B:517-20.
    • (1988) J Bone and Jt Surg , vol.70 B , pp. 517-520
    • Black, J.1
  • 4
    • 0026324454 scopus 로고
    • Implications of metallic corrosion in total knee arthroplasty
    • [4] Wapner KL. Implications of metallic corrosion in total knee arthroplasty. Clin Orthop 1991;271:12-20.
    • (1991) Clin Orthop , vol.271 , pp. 12-20
    • Wapner, K.L.1
  • 6
    • 0026754651 scopus 로고
    • Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy
    • [6] Semlitsch MF, Weber H, Streicher RM, Schon R. Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy. Biomaterials 1992;13:781-8.
    • (1992) Biomaterials , vol.13 , pp. 781-788
    • Semlitsch, M.F.1    Weber, H.2    Streicher, R.M.3    Schon, R.4
  • 9
    • 0028309860 scopus 로고
    • New surface-hardened, low modulus, corrosion resistant Ti-13Nb-13Zr alloy for total hip arthroplasty
    • [9] Davidson JA, Mishra AK, Kovacs P, Poggie RA. New surface-hardened, low modulus, corrosion resistant Ti-13Nb-13Zr alloy for total hip arthroplasty. Biomed Mater Eng 1994;4:231-43.
    • (1994) Biomed Mater Eng , vol.4 , pp. 231-243
    • Davidson, J.A.1    Mishra, A.K.2    Kovacs, P.3    Poggie, R.A.4
  • 10
    • 0002477640 scopus 로고
    • Corrosion resistance of titanium CP in saline physiological solutions with calcium phosphate and proteins
    • [10] Sousa SR, Barbosa MA. Corrosion resistance of titanium CP in saline physiological solutions with calcium phosphate and proteins. Clin Mater 1993;12:1-4.
    • (1993) Clin Mater , vol.12 , pp. 1-4
    • Sousa, S.R.1    Barbosa, M.A.2
  • 11
    • 0021275397 scopus 로고
    • Electrochemical corrosion of metallic biomaterials
    • [11] Pourbaix M. Electrochemical corrosion of metallic biomaterials. Biomaterials 1984;5:122-34.
    • (1984) Biomaterials , vol.5 , pp. 122-134
    • Pourbaix, M.1
  • 12
    • 0021845161 scopus 로고
    • Physiological and microbiological corrosion
    • [12] Williams DF. Physiological and microbiological corrosion. Crit Rev Biocompat 1985;1:1-24.
    • (1985) Crit Rev Biocompat , vol.1 , pp. 1-24
    • Williams, D.F.1
  • 13
    • 0018993783 scopus 로고
    • Electrochemical corrosion in saline and serum
    • [13] Brown SA, Merritt K. Electrochemical corrosion in saline and serum. J Biomed Mater Res 1980;14:173-5.
    • (1980) J Biomed Mater Res , vol.14 , pp. 173-175
    • Brown, S.A.1    Merritt, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.