1
-
-
0038687877
-
The LVAD: A case study
-
V. L. Poirier, "The LVAD: A case study," The Bridge, vol. 27, pp. 14-20, 1997.
-
(1997)
The Bridge
, vol.27
, pp. 14-20
-
-
Poirier, V.L.1
-
2
-
-
0032727086
-
Left ventricular assist systems as a bridge to myocardial recovery
-
H. Frazier and T. J. Myers, "Left ventricular assist systems as a bridge to myocardial recovery," Annals Thoracic Surg., vol. 68, pp. 734-741, 1999.
-
(1999)
Annals Thoracic Surg
, vol.68
, pp. 734-741
-
-
Frazier, H.1
Myers, T.J.2
-
3
-
-
0033945443
-
The History of Continuous-Flow Blood Pumps
-
D. B. Olsen, "The History of Continuous-Flow Blood Pumps," Artif. Organs, vol. 24, no. 6, pp. 401-404, 2000.
-
(2000)
Artif. Organs
, vol.24
, Issue.6
, pp. 401-404
-
-
Olsen, D.B.1
-
4
-
-
0037694091
-
Hierarchical control for hearts assist devices
-
Mar
-
J. R. Boston, J. F. Antaki, and M. Simaan, "Hierarchical control for hearts assist devices," IEEE Robot. Autom. Mag., vol. 10, no. 1, pp. 54-64, Mar. 2003.
-
(2003)
IEEE Robot. Autom. Mag
, vol.10
, Issue.1
, pp. 54-64
-
-
Boston, J.R.1
Antaki, J.F.2
Simaan, M.3
-
5
-
-
0026538807
-
Noninvasive monitoring of rotary blood pumps: Necessity, possibilities, and limitations
-
H. Shima, W. Trubel, A. Moritz, G. Wieselthaler, H. G. Stohr, H. Thomas, U. Losert, and E. Wolner, "Noninvasive monitoring of rotary blood pumps: Necessity, possibilities, and limitations," Artif. Organs, vol. 14, no. 2, pp. 195-202, 1992.
-
(1992)
Artif. Organs
, vol.14
, Issue.2
, pp. 195-202
-
-
Shima, H.1
Trubel, W.2
Moritz, A.3
Wieselthaler, G.4
Stohr, H.G.5
Thomas, H.6
Losert, U.7
Wolner, E.8
-
6
-
-
8944261599
-
Controller for an axial flow blood pump
-
H. Konishi, J. F. Antaki, and D. V. Amin, "Controller for an axial flow blood pump," Artif. Organs, vol. 20, no. 6, pp. 618-620, 1996.
-
(1996)
Artif. Organs
, vol.20
, Issue.6
, pp. 618-620
-
-
Konishi, H.1
Antaki, J.F.2
Amin, D.V.3
-
7
-
-
0242301757
-
An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse
-
Y. Wu, P. Allaire, G. Tao, H. Wood, D. Olsen, and C. Tribble, "An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse," Artif. Organs, vol. 27, no. 10, pp. 926-930, 2003.
-
(2003)
Artif. Organs
, vol.27
, Issue.10
, pp. 926-930
-
-
Wu, Y.1
Allaire, P.2
Tao, G.3
Wood, H.4
Olsen, D.5
Tribble, C.6
-
8
-
-
23944506999
-
Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies
-
Portland, OR, Jun. 8-10
-
G. Giridharan, G. Pantalos, S. Koenig, K. Gillars, and M. Skliar, "Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies," in Proc. 2005 Amer. Contr. Conf. Portland, OR, Jun. 8-10, 2005, pp. 3823-3828.
-
(2005)
Proc. 2005 Amer. Contr. Conf
, pp. 3823-3828
-
-
Giridharan, G.1
Pantalos, G.2
Koenig, S.3
Gillars, K.4
Skliar, M.5
-
9
-
-
23944456315
-
Physiological control of left ventricular assist devices based on gradient of flow
-
Portland, OR, Jun. 8-10
-
S. Chen, J. F. Antaki, M. A. Simaan, and J. R. Boston, "Physiological control of left ventricular assist devices based on gradient of flow," in Proc. 2005 Amer. Contr. Conf., Portland, OR, Jun. 8-10, 2005, pp. 3829-3834.
-
(2005)
Proc. 2005 Amer. Contr. Conf
, pp. 3829-3834
-
-
Chen, S.1
Antaki, J.F.2
Simaan, M.A.3
Boston, J.R.4
-
10
-
-
23044511554
-
In vitro evaluation of multiobjective hemodynamic control of a heart-assist pump
-
K.-W. Gwak, M. Ricci, S. Snyder, B. E. Paden, J. R. Boston, M. A. Simaan, and J. F. Antaki, "In vitro evaluation of multiobjective hemodynamic control of a heart-assist pump," Amer. Soc. Artif. Internal Organs (ASAIO) J., vol. 51, pp. 329-335, 2005.
-
(2005)
Amer. Soc. Artif. Internal Organs (ASAIO) J
, vol.51
, pp. 329-335
-
-
Gwak, K.-W.1
Ricci, M.2
Snyder, S.3
Paden, B.E.4
Boston, J.R.5
Simaan, M.A.6
Antaki, J.F.7
-
11
-
-
0034823945
-
Control strategy for rotary blood pumps
-
K. Ohuchi, D. Kikugawa, K. Takahashi, M. Uemura, M. Nakamura, T. Murakami, T. Sakamoto, and S. Takatani, "Control strategy for rotary blood pumps," Artif. Organs, vol. 25, no. 5, pp. 366-370, 2001.
-
(2001)
Artif. Organs
, vol.25
, Issue.5
, pp. 366-370
-
-
Ohuchi, K.1
Kikugawa, D.2
Takahashi, K.3
Uemura, M.4
Nakamura, M.5
Murakami, T.6
Sakamoto, T.7
Takatani, S.8
-
12
-
-
0032974203
-
The development of a control method for a total artificial heart using mixed venous oxygen saturation
-
M. Nakamura, T. Masuzawa, E. Tatsumi, Y. Taenaka, T. Nakamura, B. Zhang, T. Nakatani, H. Takano, and T. Ohno, "The development of a control method for a total artificial heart using mixed venous oxygen saturation," Artificial Organs, vol. 23, no. 3, pp. 235-241, 1999.
-
(1999)
Artificial Organs
, vol.23
, Issue.3
, pp. 235-241
-
-
Nakamura, M.1
Masuzawa, T.2
Tatsumi, E.3
Taenaka, Y.4
Nakamura, T.5
Zhang, B.6
Nakatani, T.7
Takano, H.8
Ohno, T.9
-
13
-
-
0036558955
-
Modeling and control of a brushless DC axial flow ventricular assist device
-
G. A. Giridharan, M. Skliar, D. B. Olsen, and G. M. Pantalos, "Modeling and control of a brushless DC axial flow ventricular assist device," Amer. Soc. Artif. Internal Organs (ASAIO) J., vol. 48, pp. 272-289, 2002.
-
(2002)
Amer. Soc. Artif. Internal Organs (ASAIO) J
, vol.48
, pp. 272-289
-
-
Giridharan, G.A.1
Skliar, M.2
Olsen, D.B.3
Pantalos, G.M.4
-
14
-
-
39649108344
-
A dynamical state space representation of a feedback controlled rotary left ventricular assist device
-
Orlando, FL, Nov. 5-11, Paper IMECE2005-80973
-
A. Ferreira, S. Chen, D. G. Galati, M. A. Simaan, and J. F. Antaki, "A dynamical state space representation of a feedback controlled rotary left ventricular assist device," in Proc. 2005 ASME Int. Mech. Eng. Congr., Orlando, FL, Nov. 5-11, 2005, Paper IMECE2005-80973.
-
(2005)
Proc. 2005 ASME Int. Mech. Eng. Congr
-
-
Ferreira, A.1
Chen, S.2
Galati, D.G.3
Simaan, M.A.4
Antaki, J.F.5
-
15
-
-
33847229865
-
A nonlinear state space model of a combined cardiovascular system and a rotary pump
-
Seville, Spain, Dec. 12-15
-
A. Ferreira, M. A. Simaan, J. R. Boston, and J. F. Antaki, "A nonlinear state space model of a combined cardiovascular system and a rotary pump," in Proc. 44th IEEE Conf. Decision Contr. Eur. Contr. Conf. Seville, Spain, Dec. 12-15, 2005, pp. 897-902.
-
(2005)
Proc. 44th IEEE Conf. Decision Contr. Eur. Contr. Conf
, pp. 897-902
-
-
Ferreira, A.1
Simaan, M.A.2
Boston, J.R.3
Antaki, J.F.4
-
16
-
-
0004006593
-
Cardiovascular modeling: The mathematical expression of blood circulation,
-
M.S. thesis, Univ. Pittsburgh, PA
-
D. S. Breitenstein, "Cardiovascular modeling: The mathematical expression of blood circulation," M.S. thesis, Univ. Pittsburgh, PA, 1993.
-
(1993)
-
-
Breitenstein, D.S.1
-
17
-
-
0004002210
-
Minimally invasive estimation of cardiovascular parameters,
-
Ph.D. thesis, Univ. Pittsburgh, PA
-
Y.-C. Yu, "Minimally invasive estimation of cardiovascular parameters," Ph.D. thesis, Univ. Pittsburgh, PA, 1998.
-
(1998)
-
-
Yu, Y.-C.1
-
18
-
-
0032096937
-
Estimation of systemic vascular bed parameters for artificial heart control
-
Jun
-
Y.-C. Yu, J. R. Boston, M. A. Simaan, and J. F. Antaki, "Estimation of systemic vascular bed parameters for artificial heart control," IEEE Trans. Autom. Contr., vol. 43, no. 6, pp. 765-778, Jun., 1998.
-
(1998)
IEEE Trans. Autom. Contr
, vol.43
, Issue.6
, pp. 765-778
-
-
Yu, Y.-C.1
Boston, J.R.2
Simaan, M.A.3
Antaki, J.F.4
-
19
-
-
0016280920
-
Instantaneous pressure-volume relationships and their ratio in the excised, supported canine left ventricle
-
H. Suga and K. Sagawa, "Instantaneous pressure-volume relationships and their ratio in the excised, supported canine left ventricle," Circulatory Res., vol. 35, no. 1, pp. 117-126, 1974.
-
(1974)
Circulatory Res
, vol.35
, Issue.1
, pp. 117-126
-
-
Suga, H.1
Sagawa, K.2
-
20
-
-
33750833453
-
Determinants of stroke volume and systolic and diastolic aortic pressure
-
N. Stergiopulos, J. Meister, and N. Westerhof, "Determinants of stroke volume and systolic and diastolic aortic pressure," Amer. J. Physiol., vol. 270, no. 6, pp. H2050-H2059, 1996.
-
(1996)
Amer. J. Physiol
, vol.270
, Issue.6
-
-
Stergiopulos, N.1
Meister, J.2
Westerhof, N.3
-
22
-
-
0030719270
-
Modeling and identification of an axial flow pump
-
Albuquerque, NM, Jun. 4-6
-
S. Choi, J. R. Boston, D. Thomas, and J. F. Antaki, "Modeling and identification of an axial flow pump," in Proc. 1997 Amer. Contr. Conf., Albuquerque, NM, Jun. 4-6, 1997, pp. 3714-3715.
-
(1997)
Proc. 1997 Amer. Contr. Conf
, pp. 3714-3715
-
-
Choi, S.1
Boston, J.R.2
Thomas, D.3
Antaki, J.F.4
-
23
-
-
0025456573
-
Computer simulation of the circulatory system during support with a rotary blood pump
-
H. Shima, J. Honigschnable, W. Trubel, and H. Thoma, "Computer simulation of the circulatory system during support with a rotary blood pump," Trans. Amer. Soc. Artif. Organs, vol. 36, no. 3, pp. M252-M254, 1990.
-
(1990)
Trans. Amer. Soc. Artif. Organs
, vol.36
, Issue.3
-
-
Shima, H.1
Honigschnable, J.2
Trubel, W.3
Thoma, H.4
-
24
-
-
33947646338
-
Frequency and time-frequency based indexes for suction detection in rotary blood pumps
-
Toulouse, France, May 14-19
-
A. Ferreira, M. A. Simaan, J. R. Boston, and J. F. Antaki, "Frequency and time-frequency based indexes for suction detection in rotary blood pumps," in Proc. 2006 IEEE Int. Conf. Acoustics Speech Signal Process., Toulouse, France, May 14-19, 2006, vol. II, pp. 1064-1067.
-
(2006)
Proc. 2006 IEEE Int. Conf. Acoustics Speech Signal Process
, vol.2
, pp. 1064-1067
-
-
Ferreira, A.1
Simaan, M.A.2
Boston, J.R.3
Antaki, J.F.4
-
25
-
-
34047105165
-
A discriminant-analysis-based suction detection system for rotary blood pumps
-
New York, NY
-
A. Ferreira, S. Chen, M. A. Simaan, J. R. Boston, and J. F. Antaki, "A discriminant-analysis-based suction detection system for rotary blood pumps," in Proc. 28th IEEE Annu. Int. Conf. Eng. Med. Biol., New York, NY, 2006, pp. 5382-5385.
-
(2006)
Proc. 28th IEEE Annu. Int. Conf. Eng. Med. Biol
, pp. 5382-5385
-
-
Ferreira, A.1
Chen, S.2
Simaan, M.A.3
Boston, J.R.4
Antaki, J.F.5
-
26
-
-
0037898308
-
Control strategy for maintaining physiological perfusion with implantable rotary blood pumps
-
G. Giridharan and M. Skliar, "Control strategy for maintaining physiological perfusion with implantable rotary blood pumps," Artif. Organs, vol. 27, pp. 639-648, 2003.
-
(2003)
Artif. Organs
, vol.27
, pp. 639-648
-
-
Giridharan, G.1
Skliar, M.2
-
27
-
-
4544289369
-
Physiological Control of Rotary Blood Pumps: An in vitro Study
-
G. Giridharan, G. Pantalos, S. Koenig, K. Gillars, and M. Skliar, "Physiological Control of Rotary Blood Pumps: An in vitro Study," Amer. Soc. Artif. Internal Organs (ASAIO) J., vol. 50, pp. 403-409, 2004.
-
(2004)
Amer. Soc. Artif. Internal Organs (ASAIO) J
, vol.50
, pp. 403-409
-
-
Giridharan, G.1
Pantalos, G.2
Koenig, S.3
Gillars, K.4
Skliar, M.5
|