메뉴 건너뛰기




Volumn 17, Issue 1, 2009, Pages 15-28

A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device

Author keywords

Cardiovascular system; Left ventricular assist device (LVAD); Pump speed feedback controller; Rotary blood pump modeling

Indexed keywords

BLOOD; CARDIOVASCULAR SYSTEM; DIFFERENTIAL EQUATIONS; FEEDBACK; FEEDBACK CONTROL; FIBER OPTIC SENSORS; FUNCTIONS; HEALTH CARE; MATHEMATICAL MODELS; NONLINEAR CONTROL SYSTEMS; NONLINEAR EQUATIONS; ROTARY PUMPS; SPEED; STATE FEEDBACK;

EID: 58249093995     PISSN: 10636536     EISSN: None     Source Type: Journal    
DOI: 10.1109/TCST.2008.912123     Document Type: Article
Times cited : (138)

References (27)
  • 1
    • 0038687877 scopus 로고    scopus 로고
    • The LVAD: A case study
    • V. L. Poirier, "The LVAD: A case study," The Bridge, vol. 27, pp. 14-20, 1997.
    • (1997) The Bridge , vol.27 , pp. 14-20
    • Poirier, V.L.1
  • 2
    • 0032727086 scopus 로고    scopus 로고
    • Left ventricular assist systems as a bridge to myocardial recovery
    • H. Frazier and T. J. Myers, "Left ventricular assist systems as a bridge to myocardial recovery," Annals Thoracic Surg., vol. 68, pp. 734-741, 1999.
    • (1999) Annals Thoracic Surg , vol.68 , pp. 734-741
    • Frazier, H.1    Myers, T.J.2
  • 3
    • 0033945443 scopus 로고    scopus 로고
    • The History of Continuous-Flow Blood Pumps
    • D. B. Olsen, "The History of Continuous-Flow Blood Pumps," Artif. Organs, vol. 24, no. 6, pp. 401-404, 2000.
    • (2000) Artif. Organs , vol.24 , Issue.6 , pp. 401-404
    • Olsen, D.B.1
  • 4
    • 0037694091 scopus 로고    scopus 로고
    • Hierarchical control for hearts assist devices
    • Mar
    • J. R. Boston, J. F. Antaki, and M. Simaan, "Hierarchical control for hearts assist devices," IEEE Robot. Autom. Mag., vol. 10, no. 1, pp. 54-64, Mar. 2003.
    • (2003) IEEE Robot. Autom. Mag , vol.10 , Issue.1 , pp. 54-64
    • Boston, J.R.1    Antaki, J.F.2    Simaan, M.3
  • 6
    • 8944261599 scopus 로고    scopus 로고
    • Controller for an axial flow blood pump
    • H. Konishi, J. F. Antaki, and D. V. Amin, "Controller for an axial flow blood pump," Artif. Organs, vol. 20, no. 6, pp. 618-620, 1996.
    • (1996) Artif. Organs , vol.20 , Issue.6 , pp. 618-620
    • Konishi, H.1    Antaki, J.F.2    Amin, D.V.3
  • 7
    • 0242301757 scopus 로고    scopus 로고
    • An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse
    • Y. Wu, P. Allaire, G. Tao, H. Wood, D. Olsen, and C. Tribble, "An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse," Artif. Organs, vol. 27, no. 10, pp. 926-930, 2003.
    • (2003) Artif. Organs , vol.27 , Issue.10 , pp. 926-930
    • Wu, Y.1    Allaire, P.2    Tao, G.3    Wood, H.4    Olsen, D.5    Tribble, C.6
  • 8
    • 23944506999 scopus 로고    scopus 로고
    • Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies
    • Portland, OR, Jun. 8-10
    • G. Giridharan, G. Pantalos, S. Koenig, K. Gillars, and M. Skliar, "Achieving physiologic perfusion with ventricular assist devices: Comparison of control strategies," in Proc. 2005 Amer. Contr. Conf. Portland, OR, Jun. 8-10, 2005, pp. 3823-3828.
    • (2005) Proc. 2005 Amer. Contr. Conf , pp. 3823-3828
    • Giridharan, G.1    Pantalos, G.2    Koenig, S.3    Gillars, K.4    Skliar, M.5
  • 9
    • 23944456315 scopus 로고    scopus 로고
    • Physiological control of left ventricular assist devices based on gradient of flow
    • Portland, OR, Jun. 8-10
    • S. Chen, J. F. Antaki, M. A. Simaan, and J. R. Boston, "Physiological control of left ventricular assist devices based on gradient of flow," in Proc. 2005 Amer. Contr. Conf., Portland, OR, Jun. 8-10, 2005, pp. 3829-3834.
    • (2005) Proc. 2005 Amer. Contr. Conf , pp. 3829-3834
    • Chen, S.1    Antaki, J.F.2    Simaan, M.A.3    Boston, J.R.4
  • 14
    • 39649108344 scopus 로고    scopus 로고
    • A dynamical state space representation of a feedback controlled rotary left ventricular assist device
    • Orlando, FL, Nov. 5-11, Paper IMECE2005-80973
    • A. Ferreira, S. Chen, D. G. Galati, M. A. Simaan, and J. F. Antaki, "A dynamical state space representation of a feedback controlled rotary left ventricular assist device," in Proc. 2005 ASME Int. Mech. Eng. Congr., Orlando, FL, Nov. 5-11, 2005, Paper IMECE2005-80973.
    • (2005) Proc. 2005 ASME Int. Mech. Eng. Congr
    • Ferreira, A.1    Chen, S.2    Galati, D.G.3    Simaan, M.A.4    Antaki, J.F.5
  • 16
    • 0004006593 scopus 로고
    • Cardiovascular modeling: The mathematical expression of blood circulation,
    • M.S. thesis, Univ. Pittsburgh, PA
    • D. S. Breitenstein, "Cardiovascular modeling: The mathematical expression of blood circulation," M.S. thesis, Univ. Pittsburgh, PA, 1993.
    • (1993)
    • Breitenstein, D.S.1
  • 17
    • 0004002210 scopus 로고    scopus 로고
    • Minimally invasive estimation of cardiovascular parameters,
    • Ph.D. thesis, Univ. Pittsburgh, PA
    • Y.-C. Yu, "Minimally invasive estimation of cardiovascular parameters," Ph.D. thesis, Univ. Pittsburgh, PA, 1998.
    • (1998)
    • Yu, Y.-C.1
  • 18
    • 0032096937 scopus 로고    scopus 로고
    • Estimation of systemic vascular bed parameters for artificial heart control
    • Jun
    • Y.-C. Yu, J. R. Boston, M. A. Simaan, and J. F. Antaki, "Estimation of systemic vascular bed parameters for artificial heart control," IEEE Trans. Autom. Contr., vol. 43, no. 6, pp. 765-778, Jun., 1998.
    • (1998) IEEE Trans. Autom. Contr , vol.43 , Issue.6 , pp. 765-778
    • Yu, Y.-C.1    Boston, J.R.2    Simaan, M.A.3    Antaki, J.F.4
  • 19
    • 0016280920 scopus 로고
    • Instantaneous pressure-volume relationships and their ratio in the excised, supported canine left ventricle
    • H. Suga and K. Sagawa, "Instantaneous pressure-volume relationships and their ratio in the excised, supported canine left ventricle," Circulatory Res., vol. 35, no. 1, pp. 117-126, 1974.
    • (1974) Circulatory Res , vol.35 , Issue.1 , pp. 117-126
    • Suga, H.1    Sagawa, K.2
  • 20
    • 33750833453 scopus 로고    scopus 로고
    • Determinants of stroke volume and systolic and diastolic aortic pressure
    • N. Stergiopulos, J. Meister, and N. Westerhof, "Determinants of stroke volume and systolic and diastolic aortic pressure," Amer. J. Physiol., vol. 270, no. 6, pp. H2050-H2059, 1996.
    • (1996) Amer. J. Physiol , vol.270 , Issue.6
    • Stergiopulos, N.1    Meister, J.2    Westerhof, N.3
  • 22
    • 0030719270 scopus 로고    scopus 로고
    • Modeling and identification of an axial flow pump
    • Albuquerque, NM, Jun. 4-6
    • S. Choi, J. R. Boston, D. Thomas, and J. F. Antaki, "Modeling and identification of an axial flow pump," in Proc. 1997 Amer. Contr. Conf., Albuquerque, NM, Jun. 4-6, 1997, pp. 3714-3715.
    • (1997) Proc. 1997 Amer. Contr. Conf , pp. 3714-3715
    • Choi, S.1    Boston, J.R.2    Thomas, D.3    Antaki, J.F.4
  • 23
    • 0025456573 scopus 로고
    • Computer simulation of the circulatory system during support with a rotary blood pump
    • H. Shima, J. Honigschnable, W. Trubel, and H. Thoma, "Computer simulation of the circulatory system during support with a rotary blood pump," Trans. Amer. Soc. Artif. Organs, vol. 36, no. 3, pp. M252-M254, 1990.
    • (1990) Trans. Amer. Soc. Artif. Organs , vol.36 , Issue.3
    • Shima, H.1    Honigschnable, J.2    Trubel, W.3    Thoma, H.4
  • 24
    • 33947646338 scopus 로고    scopus 로고
    • Frequency and time-frequency based indexes for suction detection in rotary blood pumps
    • Toulouse, France, May 14-19
    • A. Ferreira, M. A. Simaan, J. R. Boston, and J. F. Antaki, "Frequency and time-frequency based indexes for suction detection in rotary blood pumps," in Proc. 2006 IEEE Int. Conf. Acoustics Speech Signal Process., Toulouse, France, May 14-19, 2006, vol. II, pp. 1064-1067.
    • (2006) Proc. 2006 IEEE Int. Conf. Acoustics Speech Signal Process , vol.2 , pp. 1064-1067
    • Ferreira, A.1    Simaan, M.A.2    Boston, J.R.3    Antaki, J.F.4
  • 26
    • 0037898308 scopus 로고    scopus 로고
    • Control strategy for maintaining physiological perfusion with implantable rotary blood pumps
    • G. Giridharan and M. Skliar, "Control strategy for maintaining physiological perfusion with implantable rotary blood pumps," Artif. Organs, vol. 27, pp. 639-648, 2003.
    • (2003) Artif. Organs , vol.27 , pp. 639-648
    • Giridharan, G.1    Skliar, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.