메뉴 건너뛰기




Volumn 43, Issue 1, 2013, Pages 11-18

The state of instrumentation for combined positron emission tomography and magnetic resonance imaging

Author keywords

[No Author keywords available]

Indexed keywords

SILICON;

EID: 84870003476     PISSN: 00012998     EISSN: 15584623     Source Type: Journal    
DOI: 10.1053/j.semnuclmed.2012.08.003     Document Type: Review
Times cited : (24)

References (65)
  • 1
    • 80053611395 scopus 로고    scopus 로고
    • An outlook on future design of hybrid PET/MRI systems
    • H. Zaidi, A. Del Guerra An outlook on future design of hybrid PET/MRI systems Med Phys 38 2011 5667 5689
    • (2011) Med Phys , vol.38 , pp. 5667-5689
    • Zaidi, H.1    Del Guerra, A.2
  • 2
    • 60549083251 scopus 로고    scopus 로고
    • Pre-clinical PET/MR: Technological advances and new perspectives in biomedical research
    • H.F. Wehrl, M.S. Judenhofer, S. Wiehr Pre-clinical PET/MR: Technological advances and new perspectives in biomedical research Eur J Nucl Med Mol Imaging 36 suppl 1 2009 S56 S68
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Wehrl, H.F.1    Judenhofer, M.S.2    Wiehr, S.3
  • 3
    • 41549089557 scopus 로고    scopus 로고
    • Positron emission tomography/magnetic resonance imaging: The next generation of multimodality imaging?
    • B.J. Pichler, H.F. Wehrl, A. Kolb Positron emission tomography/magnetic resonance imaging: The next generation of multimodality imaging? Semin Nucl Med 38 2008 199 208
    • (2008) Semin Nucl Med , vol.38 , pp. 199-208
    • Pichler, B.J.1    Wehrl, H.F.2    Kolb, A.3
  • 4
    • 43449116898 scopus 로고    scopus 로고
    • PET/MRI hybrid imaging: Devices and initial results
    • B.J. Pichler, M.S. Judenhofer, H.F. Wehrl PET/MRI hybrid imaging: Devices and initial results Eur Radiol 18 2008 1077 1086
    • (2008) Eur Radiol , vol.18 , pp. 1077-1086
    • Pichler, B.J.1    Judenhofer, M.S.2    Wehrl, H.F.3
  • 6
    • 60549086346 scopus 로고    scopus 로고
    • The integration of positron emission tomography with magnetic resonance imaging
    • S.R. Cherry, A.Y. Louie, R.E. Jacobs The integration of positron emission tomography with magnetic resonance imaging Proc IEEE 96 2008 416 438
    • (2008) Proc IEEE , vol.96 , pp. 416-438
    • Cherry, S.R.1    Louie, A.Y.2    Jacobs, R.E.3
  • 7
    • 39049090333 scopus 로고    scopus 로고
    • Multimodality imaging of structure and function
    • D.W. Townsend Multimodality imaging of structure and function Phys Med Biol 53 2008 R1 R39
    • (2008) Phys Med Biol , vol.53
    • Townsend, D.W.1
  • 8
    • 0030215777 scopus 로고    scopus 로고
    • Combined MRI-PET scanner: A Monte Carlo evaluation of the improvements in PET resolution due to the effects of a static homogeneous magnetic field
    • R.R. Raylman, B.E. Hammer, N.L. Christensen Combined MRI-PET scanner: A Monte Carlo evaluation of the improvements in PET resolution due to the effects of a static homogeneous magnetic field IEEE Trans Nucl Sci 43 1996 2406 2412
    • (1996) IEEE Trans Nucl Sci , vol.43 , pp. 2406-2412
    • Raylman, R.R.1    Hammer, B.E.2    Christensen, N.L.3
  • 9
    • 84859583317 scopus 로고    scopus 로고
    • Study of PET intrinsic spatial resolution and contrast recovery improvement for PET/MRI systems
    • H. Peng, C.S. Levin Study of PET intrinsic spatial resolution and contrast recovery improvement for PET/MRI systems Phys Med Biol 57 2012 N101 N115
    • (2012) Phys Med Biol , vol.57
    • Peng, H.1    Levin, C.S.2
  • 10
    • 41549115846 scopus 로고    scopus 로고
    • A fusion PET-MRI system with a high-resolution research tomograph-PET and ultra-high field 7.0 T-MRI for the molecular-genetic imaging of the brain
    • Z.H. Cho, Y.D. Son, H.K. Kim A fusion PET-MRI system with a high-resolution research tomograph-PET and ultra-high field 7.0 T-MRI for the molecular-genetic imaging of the brain Proteomics 8 2008 1302 1323
    • (2008) Proteomics , vol.8 , pp. 1302-1323
    • Cho, Z.H.1    Son, Y.D.2    Kim, H.K.3
  • 11
    • 0036464422 scopus 로고    scopus 로고
    • The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph
    • K. Wienhard, M. Schmand, M.E. Casey The ECAT HRRT: Performance and first clinical application of the new high resolution research tomograph IEEE Trans Nucl Sci 49 2002 104 110
    • (2002) IEEE Trans Nucl Sci , vol.49 , pp. 104-110
    • Wienhard, K.1    Schmand, M.2    Casey, M.E.3
  • 12
    • 84871046515 scopus 로고    scopus 로고
    • GE PET/CT + MR Trimodality imaging Accessed September 6, 2012
    • GE PET/CT + MR Trimodality imaging GE Healthcare, 2012 http://www3.gehealthcare.com/en/Products/Categories/Molecular-Imaging/ PET-CT-and-MR-Trimodality-Imaging Accessed September 6, 2012
    • GE Healthcare, 2012
  • 13
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body ingenuity TF PET-MRI system
    • H. Zaidi, N. Ojha, M. Morich Design and performance evaluation of a whole-body ingenuity TF PET-MRI system Phys Med Biol 56 2011 3091 3106
    • (2011) Phys Med Biol , vol.56 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3
  • 14
    • 84871057430 scopus 로고    scopus 로고
    • Mediso: NanoScan PM Accessed September 6, 2012
    • Mediso: NanoScan PM Mediso Medical Imaging Systems, 2012 http://www.mediso.com/ Accessed September 6, 2012
    • Mediso Medical Imaging Systems, 2012
  • 15
    • 0142031161 scopus 로고    scopus 로고
    • Scintillator selection for MR-compatible gamma detectors
    • S. Yamamoto, K. Kuroda, M. Senda Scintillator selection for MR-compatible gamma detectors IEEE Trans Nucl Sci 50 2003 1683 1685
    • (2003) IEEE Trans Nucl Sci , vol.50 , pp. 1683-1685
    • Yamamoto, S.1    Kuroda, K.2    Senda, M.3
  • 16
  • 17
    • 77951197498 scopus 로고    scopus 로고
    • Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors
    • H. Peng, C.S. Levin Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors Phys Med Biol 55 2010 2761 2788
    • (2010) Phys Med Biol , vol.55 , pp. 2761-2788
    • Peng, H.1    Levin, C.S.2
  • 18
    • 58249112745 scopus 로고    scopus 로고
    • A new PET scanner with semiconductor detectors enables better identification of intratumoral inhomogeneity
    • T. Shiga, Y. Morimoto, N. Kubo A new PET scanner with semiconductor detectors enables better identification of intratumoral inhomogeneity J Nucl Med 50 2009 148 155
    • (2009) J Nucl Med , vol.50 , pp. 148-155
    • Shiga, T.1    Morimoto, Y.2    Kubo, N.3
  • 19
    • 77749307155 scopus 로고    scopus 로고
    • Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition
    • M.J. Hamamura, S. Ha, W.W. Roeck Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition Phys Med Biol 55 2010 1563 1575
    • (2010) Phys Med Biol , vol.55 , pp. 1563-1575
    • Hamamura, M.J.1    Ha, S.2    Roeck, W.W.3
  • 22
    • 77953729026 scopus 로고    scopus 로고
    • Performance evaluation of an MRI-compatible pre-clinical PET system using long optical fibers
    • J.E. Mackewn, P. Halsted, G. Charles-Edwards Performance evaluation of an MRI-compatible pre-clinical PET system using long optical fibers IEEE Trans Nucl Sci 57 2010 1052 1062
    • (2010) IEEE Trans Nucl Sci , vol.57 , pp. 1052-1062
    • MacKewn, J.E.1    Halsted, P.2    Charles-Edwards, G.3
  • 24
    • 76049103301 scopus 로고    scopus 로고
    • Preliminary evaluation of a combined microPET (R)-MR system
    • R.C. Hawkes, T.D. Fryer, S. Siegel Preliminary evaluation of a combined microPET (R)-MR system Technol Cancer Res Treat 9 2010 53 60
    • (2010) Technol Cancer Res Treat , vol.9 , pp. 53-60
    • Hawkes, R.C.1    Fryer, T.D.2    Siegel, S.3
  • 25
    • 70350176154 scopus 로고    scopus 로고
    • A multi-slice dual layer MR-compatible animal PET system
    • S. Yamamoto, J. Hatazawa, M. Imaizumi A multi-slice dual layer MR-compatible animal PET system IEEE Trans Nucl Sci 56 2009 2706 2713
    • (2009) IEEE Trans Nucl Sci , vol.56 , pp. 2706-2713
    • Yamamoto, S.1    Hatazawa, J.2    Imaizumi, M.3
  • 26
    • 77950690251 scopus 로고    scopus 로고
    • Design and performance from an integrated PET/MRI system for small animals
    • S. Yamamoto, M. Imaizumi, Y. Kanai Design and performance from an integrated PET/MRI system for small animals Ann Nucl Med 24 2010 89 98
    • (2010) Ann Nucl Med , vol.24 , pp. 89-98
    • Yamamoto, S.1    Imaizumi, M.2    Kanai, Y.3
  • 27
    • 33646472119 scopus 로고    scopus 로고
    • Design of field-cycled magnetic resonance systems for small animal imaging
    • K.M. Gilbert, W.B. Handler, T.J. Scholl Design of field-cycled magnetic resonance systems for small animal imaging Phys Med Biol 51 2006 2825 2841
    • (2006) Phys Med Biol , vol.51 , pp. 2825-2841
    • Gilbert, K.M.1    Handler, W.B.2    Scholl, T.J.3
  • 29
    • 60449097895 scopus 로고    scopus 로고
    • Performance evaluation of the LabPET APD-based digital PET scanner
    • M. Bergeron, J. Cadorette, J.F. Beaudoin Performance evaluation of the LabPET APD-based digital PET scanner IEEE Trans Nucl Sci 56 2009 10 16
    • (2009) IEEE Trans Nucl Sci , vol.56 , pp. 10-16
    • Bergeron, M.1    Cadorette, J.2    Beaudoin, J.F.3
  • 30
    • 40449116151 scopus 로고    scopus 로고
    • Benefit of time-of-flight in PET: Experimental and clinical results
    • J.S. Karp, S. Surti, M.E. Daube-Witherspoon Benefit of time-of-flight in PET: Experimental and clinical results J Nucl Med 49 2008 462 470
    • (2008) J Nucl Med , vol.49 , pp. 462-470
    • Karp, J.S.1    Surti, S.2    Daube-Witherspoon, M.E.3
  • 31
    • 34548503918 scopus 로고    scopus 로고
    • Recent advances and future advances in time-of-flight PET
    • W.W. Moses Recent advances and future advances in time-of-flight PET Nucl Instrum Methods Phys Res A 580 2007 919 924
    • (2007) Nucl Instrum Methods Phys Res A , vol.580 , pp. 919-924
    • Moses, W.W.1
  • 32
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    • C. Catana, Y. Wu, M.S. Judenhofer Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner J Nucl Med 47 2006 1968 1976
    • (2006) J Nucl Med , vol.47 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3
  • 33
    • 41649088048 scopus 로고    scopus 로고
    • Simultaneous in vivo positron emission tomography and magnetic resonance imaging
    • C. Catana, D. Procissi, Y.B. Wu Simultaneous in vivo positron emission tomography and magnetic resonance imaging Proc Natl Acad Sci U S A 105 2008 3705 3710
    • (2008) Proc Natl Acad Sci U S A , vol.105 , pp. 3705-3710
    • Catana, C.1    Procissi, D.2    Wu, Y.B.3
  • 34
    • 67649197596 scopus 로고    scopus 로고
    • PET performance evaluation of an MR-compatible PET insert
    • Y.B. Wu, C. Catana, R. Farrell PET performance evaluation of an MR-compatible PET insert IEEE Trans Nucl Sci 56 2009 574 580
    • (2009) IEEE Trans Nucl Sci , vol.56 , pp. 574-580
    • Wu, Y.B.1    Catana, C.2    Farrell, R.3
  • 35
    • 33745111311 scopus 로고    scopus 로고
    • Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI
    • B.J. Pichler, M.S. Judenhofer, C. Catana Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI J Nucl Med 47 2006 639 647
    • (2006) J Nucl Med , vol.47 , pp. 639-647
    • Pichler, B.J.1    Judenhofer, M.S.2    Catana, C.3
  • 36
    • 41849093686 scopus 로고    scopus 로고
    • Simultaneous PET-MRI: A new approach for functional and morphological imaging
    • M.S. Judenhofer, H.F. Wehrl, D.F. Newport Simultaneous PET-MRI: A new approach for functional and morphological imaging Nat Med 14 2008 459 465
    • (2008) Nat Med , vol.14 , pp. 459-465
    • Judenhofer, M.S.1    Wehrl, H.F.2    Newport, D.F.3
  • 38
    • 79953675997 scopus 로고    scopus 로고
    • Small animal simultaneous PET/MRI: Initial experiences in a 9.4 T microMRI
    • S.H. Maramraju, S.D. Smith, S.S. Junnarkar Small animal simultaneous PET/MRI: Initial experiences in a 9.4 T microMRI Phys Med Biol (UK) 56 2011 2459 2480
    • (2011) Phys Med Biol (UK) , vol.56 , pp. 2459-2480
    • Maramraju, S.H.1    Smith, S.D.2    Junnarkar, S.S.3
  • 41
    • 84864665200 scopus 로고    scopus 로고
    • Technical performance evaluation of a human brain PET/MRI system
    • A. Kolb, H.F. Wehrl, M. Hofmann Technical performance evaluation of a human brain PET/MRI system Eur Radiol 22 2012 1776 1788
    • (2012) Eur Radiol , vol.22 , pp. 1776-1788
    • Kolb, A.1    Wehrl, H.F.2    Hofmann, M.3
  • 42
    • 77956216707 scopus 로고    scopus 로고
    • Hybrid PET/MRI of intracranial masses: Initial experiences and comparison to PET/CT
    • A. Boss, S. Bisdas, A. Kolb Hybrid PET/MRI of intracranial masses: Initial experiences and comparison to PET/CT J Nucl Med 51 2010 1198 1205
    • (2010) J Nucl Med , vol.51 , pp. 1198-1205
    • Boss, A.1    Bisdas, S.2    Kolb, A.3
  • 43
    • 77951101471 scopus 로고    scopus 로고
    • Diffusion tensor imaging in a human PET/MR hybrid system
    • A. Boss, A. Kolb, M. Hofmann Diffusion tensor imaging in a human PET/MR hybrid system Investig Radiol 45 2010 270 274
    • (2010) Investig Radiol , vol.45 , pp. 270-274
    • Boss, A.1    Kolb, A.2    Hofmann, M.3
  • 44
    • 51549120220 scopus 로고    scopus 로고
    • Simultaneous MR/PET imaging of the human brain: Feasibility study
    • H.P.W. Schlemmer, B.J. Pichler, M. Schmand Simultaneous MR/PET imaging of the human brain: Feasibility study Radiology 248 2008 1028 1035
    • (2008) Radiology , vol.248 , pp. 1028-1035
    • Schlemmer, H.P.W.1    Pichler, B.J.2    Schmand, M.3
  • 45
    • 84863460848 scopus 로고    scopus 로고
    • Analysis and correction of count rate reduction during simultaneous MR-PET measurements with the BrainPET scanner
    • C. Weirich, D. Brenner, J. Scheins Analysis and correction of count rate reduction during simultaneous MR-PET measurements with the BrainPET scanner IEEE Trans Med Imaging 31 2012 1372 1380
    • (2012) IEEE Trans Med Imaging , vol.31 , pp. 1372-1380
    • Weirich, C.1    Brenner, D.2    Scheins, J.3
  • 46
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • G. Delso, S. Fürst, B. Jakoby Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner J Nucl Med 52 2011 1914 1922
    • (2011) J Nucl Med , vol.52 , pp. 1914-1922
    • Delso, G.1    Fürst, S.2    Jakoby, B.3
  • 47
    • 84871085103 scopus 로고    scopus 로고
    • Photo-detectors for time of flight positron emission tomography (ToF-PET)
    • V. Ch Spanoudaki, C.S. Levin Photo-detectors for time of flight positron emission tomography (ToF-PET) Sensors (Basel) 10 2010 10484 10505
    • (2010) Sensors (Basel) , vol.10 , pp. 10484-10505
    • Spanoudaki, V.C.1    Levin, C.S.2
  • 48
    • 79954421803 scopus 로고    scopus 로고
    • Application of silicon photomultipliers to positron emission tomography
    • E. Roncali, S.R. Cherry Application of silicon photomultipliers to positron emission tomography Ann Biomed Eng 39 2011 1358 1377
    • (2011) Ann Biomed Eng , vol.39 , pp. 1358-1377
    • Roncali, E.1    Cherry, S.R.2
  • 50
    • 84859416678 scopus 로고    scopus 로고
    • Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner
    • H.S. Yoon, G.B. Ko, S.I. Kwon Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner J Nucl Med 53 2012 608 614
    • (2012) J Nucl Med , vol.53 , pp. 608-614
    • Yoon, H.S.1    Ko, G.B.2    Kwon, S.I.3
  • 51
    • 85027948571 scopus 로고    scopus 로고
    • A feasibility study on the use of optical fibers for the transfer of scintillation light to silicon photomultipliers
    • S.J. Hong, C.M. Kim, S.M. Cho A feasibility study on the use of optical fibers for the transfer of scintillation light to silicon photomultipliers IEEE Trans Nucl Sci 58 2011 579 589
    • (2011) IEEE Trans Nucl Sci , vol.58 , pp. 579-589
    • Hong, S.J.1    Kim, C.M.2    Cho, S.M.3
  • 52
    • 84862001740 scopus 로고    scopus 로고
    • SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging
    • S.J. Hong, H.G. Kang, G.B. Ko SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging Phys Med Biol 57 2012 3869 3883
    • (2012) Phys Med Biol , vol.57 , pp. 3869-3883
    • Hong, S.J.1    Kang, H.G.2    Ko, G.B.3
  • 53
    • 79954611852 scopus 로고    scopus 로고
    • Development of small-animal PET prototype using silicon photomultiplier (SiPM): Initial results of phantom and animal imaging studies
    • S.I. Kwon, J.S. Lee, H.S. Yoon Development of small-animal PET prototype using silicon photomultiplier (SiPM): Initial results of phantom and animal imaging studies J Nucl Med 52 2011 572 579
    • (2011) J Nucl Med , vol.52 , pp. 572-579
    • Kwon, S.I.1    Lee, J.S.2    Yoon, H.S.3
  • 54
    • 84863381745 scopus 로고    scopus 로고
    • A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging
    • J. Kang, Y. Choi, K.J. Hong A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging J Instrum 6 2011 P08012
    • (2011) J Instrum , vol.6 , pp. 08012
    • Kang, J.1    Choi, Y.2    Hong, K.J.3
  • 56
    • 77951189966 scopus 로고    scopus 로고
    • Development of PET using 4x4 array of large size Geiger-mode avalanche photodiode
    • K.J. Hong, Y. Choi, J.H. Kang Development of PET using 4x4 array of large size Geiger-mode avalanche photodiode IEEE Nucl Sci Symp Med Imag Conf Rec 2009 3032 3037
    • (2009) IEEE Nucl Sci Symp Med Imag Conf Rec , pp. 3032-3037
    • Hong, K.J.1    Choi, Y.2    Kang, J.H.3
  • 57
    • 79960351814 scopus 로고    scopus 로고
    • Interference between PET and MRI sub-systems in a silicon- photomultiplier-based PET/MRI system
    • S. Yamamoto, H. Watabe, Y. Kanai Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system Phys Med Biol 56 2011 4147 4159
    • (2011) Phys Med Biol , vol.56 , pp. 4147-4159
    • Yamamoto, S.1    Watabe, H.2    Kanai, Y.3
  • 58
    • 84855611120 scopus 로고    scopus 로고
    • Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system
    • S. Yamamoto, T. Watabe, H. Watabe Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system Phys Med Biol 57 2012 N1 N13
    • (2012) Phys Med Biol , vol.57
    • Yamamoto, S.1    Watabe, T.2    Watabe, H.3
  • 59
    • 84858638035 scopus 로고    scopus 로고
    • SiPM based preclinical PET/MR insert for a human 3T MR: First imaging experiments
    • V. Schulz, B. Weissler, P. Gebhardt SiPM based preclinical PET/MR insert for a human 3T MR: First imaging experiments IEEE Nucl Sci Symp Med Imaging Conf 2011 4467 4469
    • (2011) IEEE Nucl Sci Symp Med Imaging Conf , pp. 4467-4469
    • Schulz, V.1    Weissler, B.2    Gebhardt, P.3
  • 61
    • 77649204136 scopus 로고    scopus 로고
    • Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner
    • B.J. Peng, J.H. Walton, S.R. Cherry Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner Phys Med Biol 55 2010 265 280
    • (2010) Phys Med Biol , vol.55 , pp. 265-280
    • Peng, B.J.1    Walton, J.H.2    Cherry, S.R.3
  • 62
    • 84871038540 scopus 로고    scopus 로고
    • Electromagnetic interactions in a shielded PET/MRI system for simultaneous PET/MR imaging in 9.4 T: Evaluation and results
    • (in press)
    • Maramraju SH, Smith SD, Rescia S, et al. Electromagnetic interactions in a shielded PET/MRI system for simultaneous PET/MR imaging in 9.4 T: Evaluation and results. IEEE Trans Nucl Sci (in press)
    • IEEE Trans Nucl Sci
    • Maramraju, S.H.1    Smith, S.D.2    Rescia, S.3
  • 63
    • 84871043612 scopus 로고    scopus 로고
    • Philips digital photon counting Accessed September 6, 2012
    • Philips digital photon counting Philips corporate technologies, 2012 http://www.research.philips.com/initiatives/digitalphotoncounting/ Accessed September 6, 2012
    • Philips Corporate Technologies, 2012
  • 64
    • 77949702417 scopus 로고    scopus 로고
    • LaBr(3):Ce and SiPMs for time-of-flight PET: Achieving 100 ps coincidence resolving time
    • D.R. Schaart, S. Seifert, R. Vinke LaBr(3):Ce and SiPMs for time-of-flight PET: Achieving 100 ps coincidence resolving time Phys Med Biol 55 2010 N179 N189
    • (2010) Phys Med Biol , vol.55
    • Schaart, D.R.1    Seifert, S.2    Vinke, R.3
  • 65
    • 46749102920 scopus 로고    scopus 로고
    • A prototype PET scanner with DOI-encoding detectors
    • Y. Yang, Y. Wu, J. Qi A prototype PET scanner with DOI-encoding detectors J Nucl Med 49 2008 1132 1140
    • (2008) J Nucl Med , vol.49 , pp. 1132-1140
    • Yang, Y.1    Wu, Y.2    Qi, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.