Volumn , Issue , 2009, Pages 3032-3037

Development of PET using 4 x 4 array of large size geiger-mode avalanche photodiode

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVITY DISTRIBUTION; ANALOG SIGNALS; ARRAY-TYPE; ARRIVAL TIME; BLOCK DETECTORS; BRAIN PHANTOMS; DECODER CIRCUITS; DETECTOR MODULE; DIFFERENTIAL OUTPUT; DIGITAL SIGNAL-PROCESSING METHOD; EXCESS NOISE; FAST RESPONSE; FILTERED BACK PROJECTION; FLIP CHIP TECHNOLOGIES; GEIGER MODE AVALANCHE PHOTODIODE; GRAY MATTER; HIGH GAIN; HUMAN BRAIN; INNER DIAMETERS; IRELAND; LARGE SIZES; LOW BIAS VOLTAGE; MONTE CARLO SIMULATION; OUTPUT SIGNAL; PET DETECTORS; PHANTOM IMAGES; PREAMPLIFIER CIRCUIT; READOUT CHANNELS; TIME RESOLUTION;

EID: 77951189966     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401577     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 1
    • 1642633805 scopus 로고    scopus 로고
    • PET/CT today and tomorrow
    • Jan
    • D. W. Townsend, J. P. Carney, J. T. Yap et al., "PET/CT today and tomorrow," J Nucl Med, vol. 45 Suppl 1, pp. 4S-14S, Jan, 2004.
    • (2004) J Nucl Med , vol.45 , Issue.SUPPL. 1
    • Townsend, D.W.1    Carney, J.P.2    Yap, J.T.3
  • 2
    • 16544379070 scopus 로고    scopus 로고
    • Accuracy of whole-body dualmodality fluorine-18-2-fluoro-2-deoxy-D -glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET
    • Nov 1
    • G. Antoch, N. Saoudi, H. Kuehl et al., "Accuracy of whole-body dualmodality fluorine-18-2-fluoro-2-deoxy-D -glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: comparison with CT and PET," J Clin Oncol, vol. 22, no. 21, pp. 4357-4368, Nov 1, 2004.
    • (2004) J Clin Oncol , vol.22 , Issue.21 , pp. 4357-4368
    • Antoch, G.1    Saoudi, N.2    Kuehl, H.3
  • 3
    • 1642602714 scopus 로고    scopus 로고
    • Acquisition protocol considerations for combined PET/CT imaging
    • Jan
    • T. Beyer, G. Antoch, S. Muller et al., "Acquisition protocol considerations for combined PET/CT imaging," J Nucl Med, vol. 45 Suppl 1, pp. 25S-35S, Jan, 2004.
    • (2004) J Nucl Med , vol.45 , Issue.SUPPL. 1
    • Beyer, T.1    Antoch, G.2    Muller, S.3
  • 4
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initia results with a MR-compatible PET scanner
    • Dec
    • C. Catana, Y. Wu, M. S. Judenhofer et al., "Simultaneous acquisition of multislice PET and MR images: initia results with a MR-compatible PET scanner," J Nucl Med, vol. 47, no. 12, pp. 1968-1976, Dec, 2006.
    • (2006) J Nucl Med , vol.47 , Issue.12 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3
  • 5
    • 33745111311 scopus 로고    scopus 로고
    • Performance Test of an LSO-APD Detector in a 7-T MRI Scanner for Simultaneous PET/MRI
    • B. J. Pichler, M. S. Judenhofer, C. Catana et al., "Performance Test of an LSO-APD Detector in a 7-T MRI Scanner for Simultaneous PET/MRI," The Journal of nuclear medicine, vol. 47, no. 4, pp. 639-647, 2006.
    • (2006) The Journal of Nuclear Medicine , vol.47 , Issue.4 , pp. 639-647
    • Pichler, B.J.1    Judenhofer, M.S.2    Catana, C.3
  • 6
    • 41849093686 scopus 로고    scopus 로고
    • Simultaneous PETMRI: A new approach for functional and morphological imaging
    • Apr
    • M. S. Judenhofer, H. F. Wehrl, D. F. Newport et al., "Simultaneous PETMRI: a new approach for functional and morphological imaging," Nat Med, vol. 14, no. 4, pp. 459-465, Apr, 2008.
    • (2008) Nat Med , vol.14 , Issue.4 , pp. 459-465
    • Judenhofer, M.S.1    Wehrl, H.F.2    Newport, D.F.3
  • 7
    • 0035117806 scopus 로고    scopus 로고
    • A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals
    • S. I. Ziegler, B. J. Pichler, G. Boening et al., "A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals," European journal of nuclear medicine, vol. 28, no. 2, pp. 136-143, 2001.
    • (2001) European Journal of Nuclear Medicine , vol.28 , Issue.2 , pp. 136-143
    • Ziegler, S.I.1    Pichler, B.J.2    Boening, G.3
  • 8
    • 33751412641 scopus 로고    scopus 로고
    • APD-based PET detector for simultaneous PET/MR imaging
    • R. Grazioso, N. Zhanga, J. Corbeil et al., "APD-based PET detector for simultaneous PET/MR imaging," Nucl. Instr. Meth., vol. A569, pp. 301-305, 2006.
    • (2006) Nucl. Instr. Meth. , vol.A569 , pp. 301-305
    • Grazioso, R.1    Zhanga, N.2    Corbeil, J.3
  • 9
    • 60549112968 scopus 로고    scopus 로고
    • Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector
    • V. C. Spanoudaki, A. B. Mann, A. N. Otte et al., "Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector," Journal of instrumentation an IOP and SISSA journal, vol. 2, no. 12, pp. P12002-P12002, 2007.
    • (2007) Journal of Instrumentation An IOP and SISSA Journal , vol.2 , Issue.12
    • Spanoudaki, V.C.1    Mann, A.B.2    Otte, A.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.