메뉴 건너뛰기




Volumn 56, Issue 8, 2011, Pages 2459-2480

Small animal simultaneous PET/MRI: Initial experiences in a 9.4 T microMRI

Author keywords

[No Author keywords available]

Indexed keywords

2-DEOXY-2; ACTIVITY CONCENTRATION; DETECTOR BLOCKS; DUTY CYCLES; EMISSION TOMOGRAPHY; FLUORO D GLUCOSE; GRADIENT ECHO; IN-VIVO; INNER DIAMETERS; LUTETIUM OXYORTHOSILICATE CRYSTALS; MICRO-MRI; MOUSE HEART; MR IMAGES; MRI SCANNERS; NONMAGNETICS; PET DATA; PET DETECTORS; RADIO FREQUENCY PULSE; RAT BRAIN; RAT CONSCIOUS ANIMAL PETS; RF PULSE; SIGNAL TO NOISE; SIMULTANEOUS OPERATION; SMALL-ANIMAL; SPIN ECHO; VISUAL ARTIFACTS;

EID: 79953675997     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/8/009     Document Type: Article
Times cited : (94)

References (56)
  • 3
    • 77951101471 scopus 로고    scopus 로고
    • Diffusion tensor imaging in a human PET/MR hybrid system
    • Boss A et al 2010b Diffusion tensor imaging in a human PET/MR hybrid system Invest. Radiol. 45 270-4
    • (2010) Invest. Radiol. , vol.45 , Issue.5 , pp. 270-274
    • Boss, A.1
  • 6
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    • Catana C, Wu Y, Judenhofer M S, Qi J, Pichler B J and Cherry S R 2006 Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner J. Nucl. Med. 47 1968-76 (Pubitemid 47544984)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.12 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3    Qi, J.4    Pichler, B.J.5    Cherry, S.R.6
  • 11
    • 0030753056 scopus 로고    scopus 로고
    • Experimental determination of the BOLD field strength dependence in vessels and tissue
    • DOI 10.1002/mrm.1910380220
    • Gati J S, Menon R S, Ugurbil K and Rutt B K 1997 Experimental determination of the BOLD field strength dependence in vessels and tissue Magn. Reson. Med. 38 296-302 (Pubitemid 27328259)
    • (1997) Magnetic Resonance in Medicine , vol.38 , Issue.2 , pp. 296-302
    • Gati, J.S.1    Menon, R.S.2    Ugurbil, K.3    Rutt, B.K.4
  • 12
    • 33646472119 scopus 로고    scopus 로고
    • Design of field-cycled magnetic resonance systems for small animal imaging
    • DOI 10.1088/0031-9155/51/11/010, PII S0031915506166877, 010
    • Gilbert K M, Handler W B, Scholl T J, Odegaard J W and Chronik B A 2006 Design of field-cycled magnetic resonance systems for small animal imaging Phys. Med. Biol. 51 2825-41 (Pubitemid 43832939)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.11 , pp. 2825-2841
    • Gilbert, K.M.1    Handler, W.B.2    Scholl, T.J.3    Odegaard, J.W.4    Chronik, B.A.5
  • 15
    • 64949109919 scopus 로고    scopus 로고
    • Whole-body PET/CT scanning: Estimation of radiation dose and cancer risk
    • Huang B, Law M W and Khong P L 2009 Whole-body PET/CT scanning: estimation of radiation dose and cancer risk Radiology 251 166-74
    • (2009) Radiology , vol.251 , Issue.1 , pp. 166-174
    • Huang, B.1    Law, M.W.2    Khong, P.L.3
  • 16
    • 68349128146 scopus 로고    scopus 로고
    • Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET: A validation study in ex vivo rat brain
    • Imaizumi M, Yamamoto S, Kawakami M, Aoki M, Sugiyama E, Kanai Y, Shimosegawa E and Hatazawa J 2009 Simultaneous imaging of magnetic resonance imaging and positron emission tomography by means of MRI-compatible optic fiber-based PET: a validation study in ex vivo rat brain Japan. J. Radiol. 27 252-6
    • (2009) Japan. J. Radiol. , vol.27 , Issue.6 , pp. 252-256
    • Imaizumi, M.1    Yamamoto, S.2    Kawakami, M.3    Aoki, M.4    Sugiyama, E.5    Kanai, Y.6    Shimosegawa, E.7    Hatazawa, J.8
  • 20
    • 78149431438 scopus 로고    scopus 로고
    • A feasibility study of photosensor charge signal transmission to preamplifier using long cable for development of hybrid PET-MRI
    • Kang J, Choi Y, Hong K J, Jung J H, Hu W, Huh Y S, Lim H and Kim B-T 2010 A feasibility study of photosensor charge signal transmission to preamplifier using long cable for development of hybrid PET-MRI Med. Phys. 37 5655-64
    • (2010) Med. Phys. , vol.37 , Issue.11 , pp. 5655-5664
    • Kang, J.1    Choi, Y.2    Hong, K.J.3    Jung, J.H.4    Hu, W.5    Huh, Y.S.6    Lim, H.7    Kim, B.-T.8
  • 21
    • 11944263486 scopus 로고    scopus 로고
    • Light output measurements of LSO single crystals and 4×8 arrays: Comparison of experiment with Monte Carlo simulations
    • M14-183, 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
    • Kriplani A, Stoll S P, Schlyer D J, Shokouhi S, Vaska P, Villanueva A Jr and Woody C L 2003 Light output measurements of LSO single crystals and 4 × 8 arrays: comparison of experiment with Monte Carlo simulations IEEE Nucl. Sci. Symp. Conf. Record, 2003 vol 5 pp 3036-40 (Pubitemid 40100044)
    • (2003) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 3036-3040
    • Kriplani, A.1    Stoll, S.P.2    Schlyer, D.J.3    Shokouhi, S.4    Vaska, P.5    Villanueva Jr., A.6    Woody, C.L.7
  • 25
    • 67649232487 scopus 로고    scopus 로고
    • An MR compatible PET scanner based on RatCAP for small animal imaging at 9.4 T
    • Maramraju S H et al 2008a An MR compatible PET scanner based on RatCAP for small animal imaging at 9.4 T IEEE Nucl. Sci. Symp. Conf. Rec. pp 3679-82
    • (2008) IEEE Nucl. Sci. Symp. Conf. Rec. , pp. 3679-3682
    • Maramraju, S.H.1
  • 27
    • 33745219462 scopus 로고    scopus 로고
    • PET/CT imaging techniques, considerations, and artifacts
    • PII 0000538220060500000002
    • Mawlawi O, Pan T and Macapinlac H A 2006 PET/CT imaging techniques, considerations, and artifacts J. Thorac. Imaging 21 99-110 (Pubitemid 43904258)
    • (2006) Journal of Thoracic Imaging , vol.21 , Issue.2 , pp. 99-110
    • Mawlawi, O.1    Pan, T.2    Macapinlac, H.A.3
  • 30
    • 77649204136 scopus 로고    scopus 로고
    • Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner
    • Peng B J, Walton J H, Cherry S R and Willig-Onwuachi J 2010 Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner Phys. Med. Biol. 55 265-80
    • (2010) Phys. Med. Biol. , vol.55 , Issue.1 , pp. 265-280
    • Peng, B.J.1    Walton, J.H.2    Cherry, S.R.3    Willig-Onwuachi, J.4
  • 33
    • 85008009684 scopus 로고    scopus 로고
    • The RatCAP front-end ASIC
    • Pratte J F et al 2008 The RatCAP front-end ASIC IEEE Trans. Nucl. Sci. 55 2727-35
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , Issue.5 , pp. 2727-2735
    • Pratte, J.F.1
  • 36
    • 22844444193 scopus 로고    scopus 로고
    • Whole-body MRI at high field: Technical limits and clinical potential
    • DOI 10.1007/s00330-005-2678-0
    • Schick F 2005 Whole-body MRI at high field: technical limits and clinical potential Eur. Radiol. 15 946-59 (Pubitemid 41166727)
    • (2005) European Radiology , vol.15 , Issue.5 , pp. 946-959
    • Schick, F.1
  • 37
    • 51549120220 scopus 로고    scopus 로고
    • Simultaneous MR/PET imaging of the human brain: Feasibility study
    • Schlemmer H P et al 2008 Simultaneous MR/PET imaging of the human brain: feasibility study Radiology 248 1028-35
    • (2008) Radiology , vol.248 , Issue.3 , pp. 1028-1035
    • Schlemmer, H.P.1
  • 39
    • 48349124352 scopus 로고    scopus 로고
    • A Simultaneous PET/MRI scanner based on RatCAP in small animals
    • Schlyer D et al 2007 A Simultaneous PET/MRI scanner based on RatCAP in small animals IEEE Nucl. Sci. Symp. Conf. Rec. vol 5 pp 3256-9
    • (2007) IEEE Nucl. Sci. Symp. Conf. Rec. , vol.5 , pp. 3256-3259
    • Schlyer, D.1
  • 44
    • 79953711524 scopus 로고    scopus 로고
    • Southekal S 2009 Strategies for quantitative neuroimaging with the rat conscious animal PET (RatCAP) PhD Dissertation Stony Brook University, NY
    • (2009) PhD Dissertation
    • Southekal, S.1
  • 45
    • 48149097208 scopus 로고    scopus 로고
    • Optimization of image reconstruction for the RatCAP (PET) tomograph: An analysis of the statistical quality of the system response matrix
    • Southekal S, Purschke M, Woody C L, Schlyer D J and Vaska P 2007 Optimization of image reconstruction for the RatCAP (PET) tomograph: an analysis of the statistical quality of the system response matrix IEEE Nucl. Sci. Symp. Conf. Rec. vol 4 pp 3051-4
    • (2007) IEEE Nucl. Sci. Symp. Conf. Rec. , vol.4 , pp. 3051-3054
    • Southekal, S.1    Purschke, M.2    Woody, C.L.3    Schlyer, D.J.4    Vaska, P.5
  • 49
    • 8344278123 scopus 로고    scopus 로고
    • RatCAP: Miniaturized head-mounted PET for conscious rodent brain imaging
    • Vaska P et al 2004 RatCAP: miniaturized head-mounted PET for conscious rodent brain imaging IEEE Trans. Nucl. Sci. 51 2718-22
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2718-2722
    • Vaska, P.1
  • 50
    • 48149115368 scopus 로고    scopus 로고
    • The design and performance of the 2nd-generation RatCAP awake rat brain PET system
    • Vaska P et al 2007 The design and performance of the 2nd-generation RatCAP awake rat brain PET system IEEE Nucl. Sci. Symp. Conf. Rec. vol 6 pp 4181-4
    • (2007) IEEE Nucl. Sci. Symp. Conf. Rec. , vol.6 , pp. 4181-4184
    • Vaska, P.1
  • 51
    • 79954428817 scopus 로고    scopus 로고
    • Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T
    • Wehrl H F, Judenhofer M S, Thielscher A, Martirosian P, Schick F and Pichler B J 2010 Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T Magn. Reson. Med. 65 269-79
    • (2010) Magn. Reson. Med. , vol.65 , pp. 269-279
    • Wehrl, H.F.1    Judenhofer, M.S.2    Thielscher, A.3    Martirosian, P.4    Schick, F.5    Pichler, B.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.