-
1
-
-
85024389446
-
-
[televised interview]. Broadcast date: May 19 Canadian, Canadian Broadcasting Corporation (CBC). Available from: Digital News Archives
-
Hopps JA. First pacemaker implated in human [televised interview]. Broadcast date: May 19, 1984. Canadian Broadcasting Corporation (CBC). Available from: Digital News Archives, http://archives.cbc.ca/on_this_day/10/08/
-
(1984)
First pacemaker implated in human
-
-
Hopps, J.A.1
-
2
-
-
77954293939
-
-
Cambridge, MA: Harvard University; The Harvard Guide
-
The Harvard Guide. A Nobel legacy 1974 - 2005. Cambridge, MA: Harvard University; 2007.
-
(2007)
A Nobel legacy 1974-2005
-
-
-
3
-
-
85024366330
-
-
Lown Foundation. Dr. Bernard Lown: a documentary. Available from
-
Lown Foundation. Dr. Bernard Lown: a documentary. 2009. Available from: http://vimeo.com/2030541?pg=embed&sec=2030541
-
(2009)
-
-
-
4
-
-
73649169745
-
Cardioversion of atrial fibrillation - a report on the treatment of 65 episodes in 50 patients
-
Lown B, Perlroth MG, Bey Sk, Abe T, Harken DE. Cardioversion of atrial fibrillation - a report on the treatment of 65 episodes in 50 patients. New Eng J Med. 1963;269(331):325.
-
(1963)
New Eng J Med
, vol.269
, Issue.331
, pp. 325
-
-
Lown, B.1
Perlroth, M.G.2
Bey, S.3
Abe, T.4
Harken, D.E.5
-
6
-
-
11144324879
-
Clinical assessment and management of patients with implanted cardioverter-defibrillators presenting to nonelectrophysiologists
-
Stevenson WG, Chaitman BR, Ellenbogen KA, et al. Clinical assessment and management of patients with implanted cardioverter-defibrillators presenting to nonelectrophysiologists. Circulation J. 2004;110:3866-69.
-
(2004)
Circulation J
, vol.110
, pp. 3866-3869
-
-
Stevenson, W.G.1
Chaitman, B.R.2
Ellenbogen, K.A.3
-
7
-
-
33745482583
-
A unique historical overview of the implantable cardioverter-defibrillator
-
Myerburg R, Castellanos A. A unique historical overview of the implantable cardioverter-defibrillator. Heart Rhythm. 2006;3(7):769-70.
-
(2006)
Heart Rhythm
, vol.3
, Issue.7
, pp. 769-770
-
-
Myerburg, R.1
Castellanos, A.2
-
8
-
-
23244453213
-
Influence of radiotherapy on the latest generation of pacemakers
-
Hurkmans C, Scheepers E, Springorum B, Uiterwaal H. Influence of radiotherapy on the latest generation of pacemakers. Radiother Oncol. 2005;76(1):93-98.
-
(2005)
Radiother Oncol
, vol.76
, Issue.1
, pp. 93-98
-
-
Hurkmans, C.1
Scheepers, E.2
Springorum, B.3
Uiterwaal, H.4
-
9
-
-
26944493433
-
Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators
-
Hurkmans C, Scheepers E, Springorum B, Uiterwaal H. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys. 2005;63(1):282-89.
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, Issue.1
, pp. 282-289
-
-
Hurkmans, C.1
Scheepers, E.2
Springorum, B.3
Uiterwaal, H.4
-
11
-
-
31644435757
-
Does high-power computed tomography scanning equipment affect the operation of pacemakers?
-
Yamaji S, Imai S, Saito F, Yagi H, Kushiro T, Uchiyama T. Does high-power computed tomography scanning equipment affect the operation of pacemakers? Circulation J. 2006;70(2):190-97.
-
(2006)
Circulation J
, vol.70
, Issue.2
, pp. 190-197
-
-
Yamaji, S.1
Imai, S.2
Saito, F.3
Yagi, H.4
Kushiro, T.5
Uchiyama, T.6
-
12
-
-
34249046434
-
Effects of CT irradiation on implantable cardiac rhythm management devices
-
McCollough CH, Zhang J, Primak AN, Clement WJ, Buysman JR. Effects of CT irradiation on implantable cardiac rhythm management devices. Radiology. 2007;243(3):766-74.
-
(2007)
Radiology
, vol.243
, Issue.3
, pp. 766-774
-
-
McCollough, C.H.1
Zhang, J.2
Primak, A.N.3
Clement, W.J.4
Buysman, J.R.5
-
13
-
-
85024406643
-
-
Silver Spring, MD: Center for Devices and Radiological Health
-
Schultz DG. CDRH FY Annual Report - Highlights. Silver Spring, MD: Center for Devices and Radiological Health; 2005.
-
(2005)
CDRH FY Annual Report - Highlights
-
-
Schultz, D.G.1
-
14
-
-
0027976720
-
Management of radiation oncology patients with implanted cardiac pacemakers
-
AAPM report of Task Group No. 34 (TG-34)
-
Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB. Management of radiation oncology patients with implanted cardiac pacemakers. AAPM report of Task Group No. 34 (TG-34). Med Phys. 1994;21(1):85-90.
-
(1994)
Med Phys
, vol.21
, Issue.1
, pp. 85-90
-
-
Marbach, J.R.1
Sontag, M.R.2
Van Dyk, J.3
Wolbarst, A.B.4
-
15
-
-
85024362340
-
-
(FDA), Center for Devices and Radiological Health. 21 April Available from
-
White GA. Letter to the U.S. Food and Drug Administration (FDA), Center for Devices and Radiological Health. 21 April 2008. Available from: http://www.aapm.org/government_affairs/documents/AAPM_comments_FDA_notification_ CT_integrated_04-21-08.pdf
-
(2008)
Letter to the U.S. Food and Drug Administration
-
-
White, G.A.1
-
16
-
-
44349084185
-
Effects of scatter radiation on ICD and CRT function
-
Kapa S, Fong L, Blackwell CR, Herman MG, Schomberg PJ, Hayes DL. Effects of scatter radiation on ICD and CRT function. Pacing Clin Electrophysiol. 2008;31(6):727-32.
-
(2008)
Pacing Clin Electrophysiol
, vol.31
, Issue.6
, pp. 727-732
-
-
Kapa, S.1
Fong, L.2
Blackwell, C.R.3
Herman, M.G.4
Schomberg, P.J.5
Hayes, D.L.6
-
17
-
-
85024386387
-
Medical device market report, Q4 2008
-
PA: IMS Health; IMS Health
-
IMS Health. Medical device market report, Q4 2008. Plymouth Meeting, PA: IMS Health; 2008.
-
(2008)
Plymouth Meeting
-
-
-
18
-
-
0037833706
-
Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale
-
Coolens C, Childs PJ. Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale. Phys Med Biol. 2003;48(11):1591-1603.
-
(2003)
Phys Med Biol
, vol.48
, Issue.11
, pp. 1591-1603
-
-
Coolens, C.1
Childs, P.J.2
-
19
-
-
0032874911
-
AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
-
Almond PR, Biggs PJ, Coursey BM, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26(9):1847-70
-
(1999)
Med Phys
, vol.26
, Issue.9
, pp. 1847-1870
-
-
Almond, P.R.1
Biggs, P.J.2
Coursey, B.M.3
-
20
-
-
0003722288
-
-
IEC. International Electrotechnical Commission (IEC). 1217 1996-08. Geneva, Switzerland: IEC
-
International Electrotechnical Commission (IEC). Radiotherapy equipment - coordinates, movements and scales. IEC 1217 (1996-08). Geneva, Switzerland: IEC; 1996.
-
(1996)
Radiotherapy equipment - coordinates, movements and scales
-
-
-
21
-
-
0003722288
-
-
IEC 61217 2008-04. Geneva, Switzerland: IEC; International Electrotechnical Commission (IEC)
-
International Electrotechnical Commission (IEC). Radiotherapy equipment - coordinates, movements and scales. IEC 61217 (2008-04). Geneva, Switzerland: IEC; 2008.
-
(2008)
Radiotherapy equipment - coordinates, movements and scales
-
-
-
22
-
-
77749246162
-
Dosimetric effects near implanted vascular access ports: an examination of external photon beam dose calculations
-
Gossman MS, Seuntjens JP, Serban MM, Lawson RC, Robertson MA, Lopez JP, Justice TE. Dosimetric effects near implanted vascular access ports: an examination of external photon beam dose calculations J Appl Clin Med Phys. 2009;10(3):3-15
-
(2009)
J Appl Clin Med Phys
, vol.10
, Issue.3
, pp. 3-15
-
-
Gossman, M.S.1
Seuntjens, J.P.2
Serban, M.M.3
Lawson, R.C.4
Robertson, M.A.5
Lopez, J.P.6
Justice, T.E.7
-
23
-
-
10744226022
-
Dosimetric considerations for patients with HIP prosthetics undergoing pelvis irradiation, Report of the AAPM Radiation Therapy Committee Task Group 63
-
Reft C, Alecu R, Das IJ, et al. Dosimetric considerations for patients with HIP prosthetics undergoing pelvis irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys. 2003;30(6):1162-82.
-
(2003)
Med Phys
, vol.30
, Issue.6
, pp. 1162-1182
-
-
Reft, C.1
Alecu, R.2
Das, I.J.3
-
24
-
-
22844450224
-
A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations
-
Ulmer W, Pyyry J, Kaissl W. A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations. Phys Med Biol. 2005;50(8):1767-90.
-
(2005)
Phys Med Biol
, vol.50
, Issue.8
, pp. 1767-1790
-
-
Ulmer, W.1
Pyyry, J.2
Kaissl, W.3
-
25
-
-
33644694219
-
Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water
-
Fogliata G, Nicolini E, Vanetti E, Clivio A, Cozzi L. Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water. Phys Med Biol. 2006;51(6):1421-38.
-
(2006)
Phys Med Biol
, vol.51
, Issue.6
, pp. 1421-1438
-
-
Fogliata, G.1
Nicolini, E.2
Vanetti, E.3
Clivio, A.4
Cozzi, L.5
-
26
-
-
0346218242
-
Monte Carlo dose calculations in the treatment of a pelvis with implant and comparison with pencil-beam calculations
-
Laub UL, Nüsslin F. Monte Carlo dose calculations in the treatment of a pelvis with implant and comparison with pencil-beam calculations. Med Dosim. 2003;28(4):229-33.
-
(2003)
Med Dosim
, vol.28
, Issue.4
, pp. 229-233
-
-
Laub, U.L.1
Nüsslin, F.2
-
27
-
-
0023521547
-
Backscatter radiation at titanium interface from high energy X and gamma rays
-
Mian TA, Van Putten MC, Kramer DC, Jacob RF, Boyer AL. Backscatter radiation at titanium interface from high energy X and gamma rays. Int J Radiat Oncol Biol Phys. 1987;13(12):1943-47.
-
(1987)
Int J Radiat Oncol Biol Phys
, vol.13
, Issue.12
, pp. 1943-1947
-
-
Mian, T.A.1
Van Putten, M.C.2
Kramer, D.C.3
Jacob, R.F.4
Boyer, A.L.5
-
28
-
-
0026316894
-
Primary mandibular reconstruction: analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates
-
Pt 2
-
Gullane PJ. Primary mandibular reconstruction: analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates. Laryngoscope. 1991;101(6 Pt 2 Suppl 54):1-24.
-
(1991)
Laryngoscope
, vol.101
, Issue.6 SUPPL 54
, pp. 1-24
-
-
Gullane, P.J.1
-
29
-
-
0021253038
-
Radiotherapy treatment planning for patients fitted with prostheses
-
Hudson FR, Crawley MT, Samarasekera M. Radiotherapy treatment planning for patients fitted with prostheses. Br J Radiol. 1984;57(679):603-08.
-
(1984)
Br J Radiol
, vol.57
, Issue.679
, pp. 603-608
-
-
Hudson, F.R.1
Crawley, M.T.2
Samarasekera, M.3
-
30
-
-
2942523218
-
The utilization of a 3-dimensional noncoplanar treatment plan to avoid pacemaker complication
-
Riley J, Garcia T, Guerrero T. The utilization of a 3-dimensional noncoplanar treatment plan to avoid pacemaker complication. Med Dosim. 2003;29:92-96.
-
(2003)
Med Dosim
, vol.29
, pp. 92-96
-
-
Riley, J.1
Garcia, T.2
Guerrero, T.3
|