메뉴 건너뛰기




Volumn 33, Issue 10, 2010, Pages 1174-1181

X-ray radiation causes electromagnetic interference in implantable cardiac pacemakers

Author keywords

electromagnetic interference; implantable cardiac pacemaker; x ray

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; COMPUTER ASSISTED TOMOGRAPHY; ELECTROMAGNETIC FIELD; IMPLANT; RADIATION DOSE; SEMICONDUCTOR; X RAY;

EID: 77957369872     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2010.02846.x     Document Type: Article
Times cited : (19)

References (14)
  • 1
    • 20544459682 scopus 로고    scopus 로고
    • The effect of electromagnetic interference in pacemaker implanted patients by cellular phones
    • Yamamoto T, Matsumoto K, Saitou J, Uchida M, Katou R, Yamada Y, Suga C, et al. The effect of electromagnetic interference in pacemaker implanted patients by cellular phones. J Arrhythmia 1998 14 : 228 294.
    • (1998) J Arrhythmia , vol.14 , pp. 228-294
    • Yamamoto, T.1    Matsumoto, K.2    Saitou, J.3    Uchida, M.4    Katou, R.5    Yamada, Y.6    Suga, C.7
  • 4
    • 20544459227 scopus 로고    scopus 로고
    • Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven
    • Hirose M, Hida M, Sato E, Kokubo K, Nie M, Kobayashi H. Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven. Pacing Clin Electrophysiol 2005 28 : 540 548.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 540-548
    • Hirose, M.1    Hida, M.2    Sato, E.3    Kokubo, K.4    Nie, M.5    Kobayashi, H.6
  • 7
    • 27544509139 scopus 로고    scopus 로고
    • Radiotherapy to patients with artificial cardiac pacemakers
    • Sundar S, Symonds RP, Deehan C. Radiotherapy to patients with artificial cardiac pacemakers. Cancer Treat Rev 2005 31 : 474 486.
    • (2005) Cancer Treat Rev , vol.31 , pp. 474-486
    • Sundar, S.1    Symonds, R.P.2    Deehan, C.3
  • 8
    • 77957368924 scopus 로고    scopus 로고
    • Ministry of Health, Labour and Welfare in Japan: Safety Information No.213, Such As Medical Supplies and Medical Devices, "the Influence on the Cardiac Pacemaker (InSync 8040, Medtronics Co. Ltd) Which X-ray CT Equipment
    • Ministry of Health, Labour and Welfare in Japan: Safety information No.213, such as medical supplies and medical devices, "The influence on the cardiac pacemaker (InSync 8040, Medtronics Co. Ltd) which X-ray CT equipment 2005.
    • (2005)
  • 9
    • 31644448989 scopus 로고    scopus 로고
    • The malfunction of permanent pacemaker induced during CT scanning. LPN
    • Yamaji S, Imai S, Yagi H, Kushiro T. The malfunction of permanent pacemaker induced during CT scanning. LPN. J Electrocardiol 2005 25 : 283 288.
    • (2005) J Electrocardiol , vol.25 , pp. 283-288
    • Yamaji, S.1    Imai, S.2    Yagi, H.3    Kushiro, T.4
  • 10
    • 31644435757 scopus 로고    scopus 로고
    • Dose high-power computed tomography scanning equipment affect the operation of pacemakers?
    • Yamaji S, Imai S, Saito F, Yagi H, Kushiro T, Uchiyama T. Dose high-power computed tomography scanning equipment affect the operation of pacemakers? Cire J 2006 70 : 190 197.
    • (2006) Cire J , vol.70 , pp. 190-197
    • Yamaji, S.1    Imai, S.2    Saito, F.3    Yagi, H.4    Kushiro, T.5    Uchiyama, T.6
  • 12
    • 0021740872 scopus 로고
    • Interference in pacemakers
    • Irnich W. Interference in pacemakers. Pacing Clin Electrophysiol 1984 7 : 1021 1048.
    • (1984) Pacing Clin Electrophysiol , vol.7 , pp. 1021-1048
    • Irnich, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.