Volumn 26, Issue 4, 2012, Pages 253-258

(v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear

Author keywords

Adverse conditions; Edge loading; Metal on metal hips; Pre clinical simulation; Stratified approach for enhanced reliability SAFER; Wear

Indexed keywords

ARTICLE; BONE RADIOGRAPHY; CERAMIC PROSTHESIS; FRICTION; HIP PROSTHESIS; HUMAN; IN VITRO STUDY; LUBRICATION; MEASUREMENT; PRIORITY JOURNAL; PROSTHESIS FAILURE; SIMULATION; SIMULATOR;

EID: 84867132511     PISSN: 18771327     EISSN: 18771335     Source Type: Journal    
DOI: 10.1016/j.mporth.2012.05.005     Document Type: Article
Times cited : (8)

References (31)
  • 1
    • 20444381731 scopus 로고    scopus 로고
    • Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty
    • Clarke M.T., Darrah C., Stewart T., Ingham E., Fisher J., Nolan J.F. Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty. J Arthroplasty 2005, 20:542-546.
    • (2005) J Arthroplasty , vol.20 , pp. 542-546
    • Clarke, M.T.1    Darrah, C.2    Stewart, T.3    Ingham, E.4    Fisher, J.5    Nolan, J.F.6
  • 2
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers
    • Ingham E., Fisher J. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers. J Eng Med 2000, 214H:21-37.
    • (2000) J Eng Med , vol.214 H , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 3
    • 0037290074 scopus 로고    scopus 로고
    • Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
    • Germain M.A., Hatton A., Williams S., et al. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials 2003, 24:469-479.
    • (2003) Biomaterials , vol.24 , pp. 469-479
    • Germain, M.A.1    Hatton, A.2    Williams, S.3
  • 4
    • 9644279533 scopus 로고    scopus 로고
    • Cup inclination angle and serum concentration of cobalt and chromium after metal on metal total hip arthroplasty
    • Brodner W., Grubl A., Jankovsky R., Meisinger V., Lehr S., Gottsauner Wolf F. Cup inclination angle and serum concentration of cobalt and chromium after metal on metal total hip arthroplasty. J Arthroplasty 2004, 19:66-70.
    • (2004) J Arthroplasty , vol.19 , pp. 66-70
    • Brodner, W.1    Grubl, A.2    Jankovsky, R.3    Meisinger, V.4    Lehr, S.5    Gottsauner Wolf, F.6
  • 5
    • 53649088948 scopus 로고    scopus 로고
    • Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of components
    • De Haan R., Campbell P.A., Su E.P., De Smet K.A. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of components. J Bone Joint Surg Br 2008, 90B:1158-1163.
    • (2008) J Bone Joint Surg Br , vol.90 B , pp. 1158-1163
    • De Haan, R.1    Campbell, P.A.2    Su, E.P.3    De Smet, K.A.4
  • 6
    • 47549111326 scopus 로고    scopus 로고
    • Pseudotumours associated with metal-on-metal hip resurfacings
    • Pandit H., Glyn-Jones S., McLardy-Smith P., et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2008, 90B:847-851.
    • (2008) J Bone Joint Surg Br , vol.90 B , pp. 847-851
    • Pandit, H.1    Glyn-Jones, S.2    McLardy-Smith, P.3
  • 7
    • 49849087899 scopus 로고    scopus 로고
    • Modes of implant failure after hip resurfacing, morphological and wear analysis of 267 retrieval specimens
    • Morlock M.M., Bishop N., Zustin J., Hann M., Ruther W., Amling M. Modes of implant failure after hip resurfacing, morphological and wear analysis of 267 retrieval specimens. J Bone Joint Surg Am 2008, 90A:89-95.
    • (2008) J Bone Joint Surg Am , vol.90 A , pp. 89-95
    • Morlock, M.M.1    Bishop, N.2    Zustin, J.3    Hann, M.4    Ruther, W.5    Amling, M.6
  • 8
    • 79960628879 scopus 로고    scopus 로고
    • Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective
    • Fisher J. Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective. J Bone Joint Surg Br 2011, 93:1001-1004.
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 1001-1004
    • Fisher, J.1
  • 10
    • 84867135911 scopus 로고    scopus 로고
    • Orthopaedics and trauma (in press).
    • Jennings et al. Orthopaedics and trauma (in press).
    • Jennings1
  • 11
    • 0032881955 scopus 로고    scopus 로고
    • Analysis of retrieved alumina ceramic components for Mittelmeier total hip prostheses
    • Nevelos J.E., Ingham E., Doyle C., Nevelos A.B., Fisher J. Analysis of retrieved alumina ceramic components for Mittelmeier total hip prostheses. Biomaterials 1999, 20:1833-1840.
    • (1999) Biomaterials , vol.20 , pp. 1833-1840
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 12
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centers of alumina-alumna artificial hip joints during simulator testing produces clinically relevant wear and patterns
    • Nevelos J., Ingham E., Doyle C., et al. Microseparation of the centers of alumina-alumna artificial hip joints during simulator testing produces clinically relevant wear and patterns. J Arthroplasty 2000, 15:793-795.
    • (2000) J Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3
  • 13
    • 0034981637 scopus 로고    scopus 로고
    • Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening
    • Nevelos J.E., Prudhommeaux Hamadouche M., Doyle C., et al. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br 2001, 83B:598-603.
    • (2001) J Bone Joint Surg Br , vol.83 B , pp. 598-603
    • Nevelos, J.E.1    Prudhommeaux, H.M.2    Doyle, C.3
  • 14
    • 0035114433 scopus 로고    scopus 로고
    • The influence of acetabular cup angle on the wear of " BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
    • Nevelos J.E., Ingham E., Doyle C., Nevelos A.B., Fisher J. The influence of acetabular cup angle on the wear of " BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001, 12:141-144.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 141-144
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 15
    • 78649658341 scopus 로고    scopus 로고
    • Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX delta ceramic-on-ceramic total hip replacement
    • Al-Hajjar M., Leslie I.J., Tipper J., Williams S., Fisher J., Jennings L.M. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res Appl Biomater 2010, 95B:263-268.
    • (2010) J Biomed Mater Res Appl Biomater , vol.95 B , pp. 263-268
    • Al-Hajjar, M.1    Leslie, I.J.2    Tipper, J.3    Williams, S.4    Fisher, J.5    Jennings, L.M.6
  • 16
    • 0035680629 scopus 로고    scopus 로고
    • Long-term wear or HIPed alumina on alumina bearings for THR under microseparation conditions
    • Stewart T., Tipper J.L., Streicher R., Ingham E., Fisher J. Long-term wear or HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001, 12:1053-1056.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 1053-1056
    • Stewart, T.1    Tipper, J.L.2    Streicher, R.3    Ingham, E.4    Fisher, J.5
  • 17
    • 0035989711 scopus 로고    scopus 로고
    • Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture micro-dissection of tissues retrieved at revision
    • Hatton A., Nevelos J.E., Nevelos A.A., Banks R.E., Fisher J., Ingham E. Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture micro-dissection of tissues retrieved at revision. Biomaterials 2002, 23:3429-3440.
    • (2002) Biomaterials , vol.23 , pp. 3429-3440
    • Hatton, A.1    Nevelos, J.E.2    Nevelos, A.A.3    Banks, R.E.4    Fisher, J.5    Ingham, E.6
  • 18
    • 0036054006 scopus 로고    scopus 로고
    • Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers
    • Mak M.M., Besong A.A., Jin Z.M., Fisher J. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers. J Eng Med 2002, 216H:403-408.
    • (2002) J Eng Med , vol.216 H , pp. 403-408
    • Mak, M.M.1    Besong, A.A.2    Jin, Z.M.3    Fisher, J.4
  • 20
    • 0030627631 scopus 로고    scopus 로고
    • Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers
    • Jin Z.M., Dowson D., Fisher J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers. J Eng Med 1997, 211H:247-256.
    • (1997) J Eng Med , vol.211 H , pp. 247-256
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 23
    • 44949186496 scopus 로고    scopus 로고
    • Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses
    • Yan Y., Neville A., Dowson D., Williams S., Fisher J. Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses. Proc Inst Mech Eng 2008, 222J:483-492.
    • (2008) Proc Inst Mech Eng , vol.222 J , pp. 483-492
    • Yan, Y.1    Neville, A.2    Dowson, D.3    Williams, S.4    Fisher, J.5
  • 24
    • 52449102219 scopus 로고    scopus 로고
    • Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements - an in vitro study
    • Leslie I., Williams S., Brown C., et al. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements - an in vitro study. J Biomed Mater Res Appl Biomater 2008, 87B:163-172.
    • (2008) J Biomed Mater Res Appl Biomater , vol.87 B , pp. 163-172
    • Leslie, I.1    Williams, S.2    Brown, C.3
  • 25
    • 2542607724 scopus 로고    scopus 로고
    • Changes in contact area during the bedding-in of different sizes of metal on metal hip prostheses
    • Hu X.Q., Isaac G.H., Fisher J. Changes in contact area during the bedding-in of different sizes of metal on metal hip prostheses. Biomed Mater Eng 2004, 14:145-149.
    • (2004) Biomed Mater Eng , vol.14 , pp. 145-149
    • Hu, X.Q.1    Isaac, G.H.2    Fisher, J.3
  • 26
    • 33747109457 scopus 로고    scopus 로고
    • Effect of swing phase load on metal-on-metal hip lubrication, friction and wear
    • Williams S., Jalai-Vahid D., Brockett C.L., et al. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear. J Biomech 2006, 39:2274-2281.
    • (2006) J Biomech , vol.39 , pp. 2274-2281
    • Williams, S.1    Jalai-Vahid, D.2    Brockett, C.L.3
  • 28
    • 49849095334 scopus 로고    scopus 로고
    • Tribology and wear of metal-on-metal hip prostheses: influence of cup and head position
    • Williams S., Leslie I., Isaac G., Jin Z., Ingham E., Fisher J. Tribology and wear of metal-on-metal hip prostheses: influence of cup and head position. J Bone Joint Surg Am 2008, 90(suppl 3):111-117.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 3 , pp. 111-117
    • Williams, S.1    Leslie, I.2    Isaac, G.3    Jin, Z.4    Ingham, E.5    Fisher, J.6
  • 29
    • 69249208803 scopus 로고    scopus 로고
    • High cup angle and microseparation increase the wear of hip surface replacements
    • Leslie I.J., Williams S., Isaac G., Ingham E., Fisher J. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 2009, 467:2259-2265.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 2259-2265
    • Leslie, I.J.1    Williams, S.2    Isaac, G.3    Ingham, E.4    Fisher, J.5
  • 30
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins P.J., Tipper J.L., Ingham E., Stone M.H., Farrar R., Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001, 11:143-157.
    • (2001) Biomed Mater Eng , vol.11 , pp. 143-157
    • Firkins, P.J.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Farrar, R.5    Fisher, J.6
  • 31
    • 17144436022 scopus 로고    scopus 로고
    • Alternate bearing couples in total hip replacements: solutions for young patients
    • Fisher J., Ingham E., Stone M.H. Alternate bearing couples in total hip replacements: solutions for young patients. Hip Int 2003, 13:S31-S35.
    • (2003) Hip Int , vol.13
    • Fisher, J.1    Ingham, E.2    Stone, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.