Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty
-
Clarke M.T., Darrah C., Stewart T., Ingham E., Fisher J., Nolan J.F. Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty. J Arthroplasty 2005, 20:542-546.
-
(2005)
J Arthroplasty
, vol.20
, pp. 542-546
-
-
Clarke, M.T.1
Darrah, C.2
Stewart, T.3
Ingham, E.4
Fisher, J.5
Nolan, J.F.6
-
2
-
-
0033628937
-
Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers
-
Ingham E., Fisher J. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers. J Eng Med 2000, 214H:21-37.
-
(2000)
J Eng Med
, vol.214 H
, pp. 21-37
-
-
Ingham, E.1
Fisher, J.2
-
3
-
-
0037290074
-
Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
-
Germain M.A., Hatton A., Williams S., et al. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials 2003, 24:469-479.
-
(2003)
Biomaterials
, vol.24
, pp. 469-479
-
-
Germain, M.A.1
Hatton, A.2
Williams, S.3
-
4
-
-
9644279533
-
Cup inclination angle and serum concentration of cobalt and chromium after metal on metal total hip arthroplasty
-
Brodner W., Grubl A., Jankovsky R., Meisinger V., Lehr S., Gottsauner Wolf F. Cup inclination angle and serum concentration of cobalt and chromium after metal on metal total hip arthroplasty. J Arthroplasty 2004, 19:66-70.
-
(2004)
J Arthroplasty
, vol.19
, pp. 66-70
-
-
Brodner, W.1
Grubl, A.2
Jankovsky, R.3
Meisinger, V.4
Lehr, S.5
Gottsauner Wolf, F.6
-
5
-
-
53649088948
-
Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of components
-
De Haan R., Campbell P.A., Su E.P., De Smet K.A. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of components. J Bone Joint Surg Br 2008, 90B:1158-1163.
-
(2008)
J Bone Joint Surg Br
, vol.90 B
, pp. 1158-1163
-
-
De Haan, R.1
Campbell, P.A.2
Su, E.P.3
De Smet, K.A.4
-
6
-
-
47549111326
-
Pseudotumours associated with metal-on-metal hip resurfacings
-
Pandit H., Glyn-Jones S., McLardy-Smith P., et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2008, 90B:847-851.
-
(2008)
J Bone Joint Surg Br
, vol.90 B
, pp. 847-851
-
-
Pandit, H.1
Glyn-Jones, S.2
McLardy-Smith, P.3
-
7
-
-
49849087899
-
Modes of implant failure after hip resurfacing, morphological and wear analysis of 267 retrieval specimens
-
Morlock M.M., Bishop N., Zustin J., Hann M., Ruther W., Amling M. Modes of implant failure after hip resurfacing, morphological and wear analysis of 267 retrieval specimens. J Bone Joint Surg Am 2008, 90A:89-95.
-
(2008)
J Bone Joint Surg Am
, vol.90 A
, pp. 89-95
-
-
Morlock, M.M.1
Bishop, N.2
Zustin, J.3
Hann, M.4
Ruther, W.5
Amling, M.6
-
8
-
-
79960628879
-
Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective
-
Fisher J. Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective. J Bone Joint Surg Br 2011, 93:1001-1004.
-
(2011)
J Bone Joint Surg Br
, vol.93
, pp. 1001-1004
-
-
Fisher, J.1
-
10
-
-
84867135911
-
-
Orthopaedics and trauma (in press).
-
Jennings et al. Orthopaedics and trauma (in press).
-
-
-
Jennings1
-
11
-
-
0032881955
-
Analysis of retrieved alumina ceramic components for Mittelmeier total hip prostheses
-
Nevelos J.E., Ingham E., Doyle C., Nevelos A.B., Fisher J. Analysis of retrieved alumina ceramic components for Mittelmeier total hip prostheses. Biomaterials 1999, 20:1833-1840.
-
(1999)
Biomaterials
, vol.20
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
12
-
-
0033814067
-
Microseparation of the centers of alumina-alumna artificial hip joints during simulator testing produces clinically relevant wear and patterns
-
Nevelos J., Ingham E., Doyle C., et al. Microseparation of the centers of alumina-alumna artificial hip joints during simulator testing produces clinically relevant wear and patterns. J Arthroplasty 2000, 15:793-795.
-
(2000)
J Arthroplasty
, vol.15
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
-
13
-
-
0034981637
-
Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening
-
Nevelos J.E., Prudhommeaux Hamadouche M., Doyle C., et al. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br 2001, 83B:598-603.
-
(2001)
J Bone Joint Surg Br
, vol.83 B
, pp. 598-603
-
-
Nevelos, J.E.1
Prudhommeaux, H.M.2
Doyle, C.3
-
14
-
-
0035114433
-
The influence of acetabular cup angle on the wear of " BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
-
Nevelos J.E., Ingham E., Doyle C., Nevelos A.B., Fisher J. The influence of acetabular cup angle on the wear of " BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001, 12:141-144.
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 141-144
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
15
-
-
78649658341
-
Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX delta ceramic-on-ceramic total hip replacement
-
Al-Hajjar M., Leslie I.J., Tipper J., Williams S., Fisher J., Jennings L.M. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res Appl Biomater 2010, 95B:263-268.
-
(2010)
J Biomed Mater Res Appl Biomater
, vol.95 B
, pp. 263-268
-
-
Al-Hajjar, M.1
Leslie, I.J.2
Tipper, J.3
Williams, S.4
Fisher, J.5
Jennings, L.M.6
-
16
-
-
0035680629
-
Long-term wear or HIPed alumina on alumina bearings for THR under microseparation conditions
-
Stewart T., Tipper J.L., Streicher R., Ingham E., Fisher J. Long-term wear or HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001, 12:1053-1056.
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.L.2
Streicher, R.3
Ingham, E.4
Fisher, J.5
-
17
-
-
0035989711
-
Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture micro-dissection of tissues retrieved at revision
-
Hatton A., Nevelos J.E., Nevelos A.A., Banks R.E., Fisher J., Ingham E. Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture micro-dissection of tissues retrieved at revision. Biomaterials 2002, 23:3429-3440.
-
(2002)
Biomaterials
, vol.23
, pp. 3429-3440
-
-
Hatton, A.1
Nevelos, J.E.2
Nevelos, A.A.3
Banks, R.E.4
Fisher, J.5
Ingham, E.6
-
18
-
-
0036054006
-
Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers
-
Mak M.M., Besong A.A., Jin Z.M., Fisher J. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers. J Eng Med 2002, 216H:403-408.
-
(2002)
J Eng Med
, vol.216 H
, pp. 403-408
-
-
Mak, M.M.1
Besong, A.A.2
Jin, Z.M.3
Fisher, J.4
-
19
-
-
0345168992
-
Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
-
Stewart T.D., Tipper J.L., Insley G., Streicher R.M., Ingham E., Fisher J. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res Appl Biomater 2003, 66B:567-573.
-
(2003)
J Biomed Mater Res Appl Biomater
, vol.66 B
, pp. 567-573
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
20
-
-
0030627631
-
Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers
-
Jin Z.M., Dowson D., Fisher J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers. J Eng Med 1997, 211H:247-256.
-
(1997)
J Eng Med
, vol.211 H
, pp. 247-256
-
-
Jin, Z.M.1
Dowson, D.2
Fisher, J.3
-
21
-
-
34247623494
-
Friction of total hip replacements with different bearings and loading conditions
-
Brockett C., Williams S., Jin Z.M., Isaac G., Fisher J. Friction of total hip replacements with different bearings and loading conditions. J Biomed Mater Res Appl Biomater 2007, 81B:508-515.
-
(2007)
J Biomed Mater Res Appl Biomater
, vol.81 B
, pp. 508-515
-
-
Brockett, C.1
Williams, S.2
Jin, Z.M.3
Isaac, G.4
Fisher, J.5
-
22
-
-
59349110642
-
Subsurface changes of a MoM hip implant below different contact zones
-
Pourzal R., Theissmann R., Williams S., Gleising B., Fisher J., Fischer A. Subsurface changes of a MoM hip implant below different contact zones. J Mech Behav Biomed 2009, 2:186-191.
-
(2009)
J Mech Behav Biomed
, vol.2
, pp. 186-191
-
-
Pourzal, R.1
Theissmann, R.2
Williams, S.3
Gleising, B.4
Fisher, J.5
Fischer, A.6
-
23
-
-
44949186496
-
Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses
-
Yan Y., Neville A., Dowson D., Williams S., Fisher J. Tribo-corrosion analysis of wear and metal ion release interactions from metal-on-metal and ceramic-on-metal contacts for the application in artificial hip prostheses. Proc Inst Mech Eng 2008, 222J:483-492.
-
(2008)
Proc Inst Mech Eng
, vol.222 J
, pp. 483-492
-
-
Yan, Y.1
Neville, A.2
Dowson, D.3
Williams, S.4
Fisher, J.5
-
24
-
-
52449102219
-
Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements - an in vitro study
-
Leslie I., Williams S., Brown C., et al. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements - an in vitro study. J Biomed Mater Res Appl Biomater 2008, 87B:163-172.
-
(2008)
J Biomed Mater Res Appl Biomater
, vol.87 B
, pp. 163-172
-
-
Leslie, I.1
Williams, S.2
Brown, C.3
-
25
-
-
2542607724
-
Changes in contact area during the bedding-in of different sizes of metal on metal hip prostheses
-
Hu X.Q., Isaac G.H., Fisher J. Changes in contact area during the bedding-in of different sizes of metal on metal hip prostheses. Biomed Mater Eng 2004, 14:145-149.
-
(2004)
Biomed Mater Eng
, vol.14
, pp. 145-149
-
-
Hu, X.Q.1
Isaac, G.H.2
Fisher, J.3
-
26
-
-
33747109457
-
Effect of swing phase load on metal-on-metal hip lubrication, friction and wear
-
Williams S., Jalai-Vahid D., Brockett C.L., et al. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear. J Biomech 2006, 39:2274-2281.
-
(2006)
J Biomech
, vol.39
, pp. 2274-2281
-
-
Williams, S.1
Jalai-Vahid, D.2
Brockett, C.L.3
-
27
-
-
3442890535
-
Metal-on-metal bearing wear with different swing phase loads
-
Williams S., Stewart T.D., Ingham E., Stone M.H., Fisher J. Metal-on-metal bearing wear with different swing phase loads. J Biomed Mater Res Appl Biomater 2004, 70B:233-239.
-
(2004)
J Biomed Mater Res Appl Biomater
, vol.70 B
, pp. 233-239
-
-
Williams, S.1
Stewart, T.D.2
Ingham, E.3
Stone, M.H.4
Fisher, J.5
-
28
-
-
49849095334
-
Tribology and wear of metal-on-metal hip prostheses: influence of cup and head position
-
Williams S., Leslie I., Isaac G., Jin Z., Ingham E., Fisher J. Tribology and wear of metal-on-metal hip prostheses: influence of cup and head position. J Bone Joint Surg Am 2008, 90(suppl 3):111-117.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL. 3
, pp. 111-117
-
-
Williams, S.1
Leslie, I.2
Isaac, G.3
Jin, Z.4
Ingham, E.5
Fisher, J.6
-
29
-
-
69249208803
-
High cup angle and microseparation increase the wear of hip surface replacements
-
Leslie I.J., Williams S., Isaac G., Ingham E., Fisher J. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 2009, 467:2259-2265.
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 2259-2265
-
-
Leslie, I.J.1
Williams, S.2
Isaac, G.3
Ingham, E.4
Fisher, J.5
-
30
-
-
0035045395
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
-
Firkins P.J., Tipper J.L., Ingham E., Stone M.H., Farrar R., Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001, 11:143-157.
-
(2001)
Biomed Mater Eng
, vol.11
, pp. 143-157
-
-
Firkins, P.J.1
Tipper, J.L.2
Ingham, E.3
Stone, M.H.4
Farrar, R.5
Fisher, J.6
-
31
-
-
17144436022
-
Alternate bearing couples in total hip replacements: solutions for young patients
-
Fisher J., Ingham E., Stone M.H. Alternate bearing couples in total hip replacements: solutions for young patients. Hip Int 2003, 13:S31-S35.
-
(2003)
Hip Int
, vol.13
-
-
Fisher, J.1
Ingham, E.2
Stone, M.H.3
|