메뉴 건너뛰기




Volumn 13 1, Issue SUPPL. 2, 2003, Pages

Alternative bearing couples in total hip replacements: Solutions for young patients

Author keywords

Bearings; Debris; Hip prostheses; Osteolytic potential; Wear

Indexed keywords

ALLOY; ALUMINUM; METAL; POLYETHYLENE;

EID: 17144436022     PISSN: 11207000     EISSN: None     Source Type: Journal    
DOI: 10.1177/112070000301302s07     Document Type: Conference Paper
Times cited : (9)

References (10)
  • 1
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement
    • Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proc Instn Mech Engrs 1999; 214 (Part H): 21-37.
    • (1999) Proc Instn Mech Engrs , vol.214 , Issue.PART H , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 2
    • 0033252596 scopus 로고    scopus 로고
    • A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    • Barbour PSM, Stone MH, Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proc Instn Mech Engrs 1999; 214 (Part H): 455-67.
    • (1999) Proc Instn Mech Engrs , vol.214 , Issue.PART H , pp. 455-467
    • Barbour, P.S.M.1    Stone, M.H.2    Fisher, J.3
  • 4
    • 0034333626 scopus 로고    scopus 로고
    • Evaluation of the response of primary human peripheral blood mononuclear phagocyted to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose
    • Matthews JB, Besong AA, Green TR, et al. Evaluation of the response of primary human peripheral blood mononuclear phagocyted to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. J Biomed Mater Res 2000; 52: 296-307.
    • (2000) J Biomed Mater Res , vol.52 , pp. 296-307
    • Matthews, J.B.1    Besong, A.A.2    Green, T.R.3
  • 5
    • 0035222710 scopus 로고    scopus 로고
    • A novel method for the prediction of functional biological activity of polyethylene wear debris
    • Fisher J, Bell J, Barbour PSM, et al. A novel method for the prediction of functional biological activity of polyethylene wear debris. Proc Instn Mech Engrs 2001; 215 (Part H): 127-32.
    • (2001) Proc Instn Mech Engrs , vol.215 , Issue.PART H , pp. 127-132
    • Fisher, J.1    Bell, J.2    Barbour, P.S.M.3
  • 6
    • 0034485401 scopus 로고    scopus 로고
    • A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups
    • Barbour PSM, Stone MH, Fisher J. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups. Proc Instn Mech Engrs 2000; 214 (Part H): 569-76.
    • (2000) Proc Instn Mech Engrs , vol.214 , Issue.PART H , pp. 569-576
    • Barbour, P.S.M.1    Stone, M.H.2    Fisher, J.3
  • 7
    • 0035114433 scopus 로고    scopus 로고
    • The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
    • Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J. The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci 2001; 12: 141-4.
    • (2001) J Mater Sci , vol.12 , pp. 141-144
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 8
    • 0035882726 scopus 로고    scopus 로고
    • Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
    • Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001; 22: 2191-7.
    • (2001) Biomaterials , vol.22 , pp. 2191-2197
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 10
    • 0035124730 scopus 로고    scopus 로고
    • Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene
    • Endo MM, Barbour PS, Barton DC, Fisher J, Tipper JL, Ingham E, Stone MH. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Biomed Mater Eng 2001; 11: 23-35.
    • (2001) Biomed Mater Eng , vol.11 , pp. 23-35
    • Endo, M.M.1    Barbour, P.S.2    Barton, D.C.3    Fisher, J.4    Tipper, J.L.5    Ingham, E.6    Stone, M.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.