메뉴 건너뛰기




Volumn 20, Issue 4, 2005, Pages 542-546

Long-term clinical, radiological and histopathological follow-up of a well-fixed McKee-Farrar metal-on-metal total hip arthroplasty

Author keywords

Metal on metal; Total hip arthroplasty; Tribology; Wear debris

Indexed keywords

ALLOY; CEMENT; POLYETHYLENE;

EID: 20444381731     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2004.09.063     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty: The role of polyethylene wear debris and the concept of effective joint space
    • T.P. Schmalzried, M. Jasty, and W.H. Harris Periprosthetic bone loss in total hip arthroplasty: the role of polyethylene wear debris and the concept of effective joint space J. Bone Joint Surg. 74A 1992 849
    • (1992) J. Bone Joint Surg. , vol.74 , pp. 849
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 2
    • 0015295233 scopus 로고
    • The long-term results of low-friction arthroplasty of the hip performed as a primary intervention
    • J. Charnley The long-term results of low-friction arthroplasty of the hip performed as a primary intervention J. Bone Joint Surg. Br. 54 1972 61
    • (1972) J. Bone Joint Surg. Br. , vol.54 , pp. 61
    • Charnley, J.1
  • 3
    • 0015304601 scopus 로고
    • Total hip replacement with fixation by acrylic cement. a preliminary study of 100 consecutive McKee-Farrar prosthetic replacements
    • P.D. Wilson Jr., H.C. Amstutz, and A. Czerniecki Total hip replacement with fixation by acrylic cement. A preliminary study of 100 consecutive McKee-Farrar prosthetic replacements J. Bone Joint Surg. Am. 54 1972 207
    • (1972) J. Bone Joint Surg. Am. , vol.54 , pp. 207
    • Wilson Jr., P.D.1    Amstutz, H.C.2    Czerniecki, A.3
  • 4
    • 0029831455 scopus 로고    scopus 로고
    • In Vivo wear of 3 types of metal on metal prostheses during 2 decades of use
    • H. McKellop, S.-H. Park, and R. Chiesa In Vivo wear of 3 types of metal on metal prostheses during 2 decades of use Clin. Orthop. Relat. Res. 329S 1996 S128
    • (1996) Clin. Orthop. Relat. Res. , vol.329 , pp. 128
    • McKellop, H.1    Park, S.-H.2    Chiesa, R.3
  • 5
    • 0029882821 scopus 로고    scopus 로고
    • Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
    • T.P. Schmalzried, P.C. Peters, and B.T. Maurer Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces J. Arthroplasty 11 1996 322
    • (1996) J. Arthroplasty , vol.11 , pp. 322
    • Schmalzried, T.P.1    Peters, P.C.2    Maurer, B.T.3
  • 6
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
    • S.L. Smith, D. Dowson, and A.A. Goldsmith The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements Proc. Inst. Mech. Eng. [H] 215 2001 161
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , pp. 161
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 7
    • 0035065646 scopus 로고    scopus 로고
    • Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
    • P.J. Firkins, J.L. Tipper, and E. Ingham Influence of simulator kinematics on the wear of metal-on-metal hip prostheses Proc. Inst. Mech. Eng. [H] 215 2001 119
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , pp. 119
    • Firkins, P.J.1    Tipper, J.L.2    Ingham, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.