메뉴 건너뛰기




Volumn 9, Issue 4, 2012, Pages 409-421

The use of oxidized zirconium alloy in knee arthroplasty

Author keywords

bearing surface; CoCr; knee arthroplasty; oxidized zirconium; TKA; wear; zirconia

Indexed keywords

BEARING SURFACES; COCR; KNEE ARTHROPLASTY; OXIDIZED ZIRCONIUM; TKA;

EID: 84865457737     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/erd.12.30     Document Type: Review
Times cited : (12)

References (82)
  • 1
    • 0023708367 scopus 로고
    • Epidemiology of hip and knee osteoarthritis
    • Felson DT. Epidemiology of hip and knee osteoarthritis. Epidemiol. Rev. 10, 1-28 (1988). (Pubitemid 18262838)
    • (1988) Epidemiologic Reviews , vol.10 , pp. 1-28
    • Felson, D.T.1
  • 2
    • 67449101122 scopus 로고    scopus 로고
    • Trends in mortality, complications, and demographics for primary hip arthroplasty in the United States
    • Liu SS, Della Valle AG, Besculides MC, Gaber LK, Memtsoudis SG. Trends in mortality, complications, and demographics for primary hip arthroplasty in the United States. Int. Orthop. 33(3), 643-651 (2009).
    • (2009) Int. Orthop. , vol.33 , Issue.3 , pp. 643-651
    • Liu, S.S.1    Della Valle, A.G.2    Besculides, M.C.3    Gaber, L.K.4    Memtsoudis, S.G.5
  • 3
    • 84864010660 scopus 로고    scopus 로고
    • Twenty-year survival analysis in total knee arthroplasty by a single surgeon
    • doi:10.1016/j.arth.2011.10.027 (Epub ahead of print
    • Bae DK, Song SJ, Park MJ, Eoh JH, Song JH, Park CH. Twenty-year survival analysis in total knee arthroplasty by a single surgeon. J. Arthroplasty doi:10.1016/j. arth.2011.10.027 (2011) (Epub ahead of print).
    • (2011) J. Arthroplasty
    • Bae, D.K.1    Song, S.J.2    Park, M.J.3    Eoh, J.H.4    Song, J.H.5    Park, C.H.6
  • 4
    • 77950502929 scopus 로고    scopus 로고
    • Knee arthroplasty in Denmark, Norway and Sweden
    • Robertsson O, Bizjajeva S, Fenstad AM et al. Knee arthroplasty in Denmark, Norway and Sweden. Acta Orthop. 81(1), 82-89 (2010).
    • (2010) Acta Orthop , vol.81 , Issue.1 , pp. 82-89
    • Robertsson, O.1    Bizjajeva, S.2    Fenstad, A.M.3
  • 5
    • 35848937784 scopus 로고    scopus 로고
    • Knee arthroplasty in the young patient: Survival in a community registry
    • DOI 10.1097/BLO.0b013e31812f79a9, PII 0000308620071100000014
    • Gioe TJ, Novak C, Sinner P, Ma W, Mehle S. Knee arthroplasty in the young patient: Survival in a community registry. Clin. Orthop. Relat. Res. 464, 83-87 (2007). (Pubitemid 350059950)
    • (2007) Clinical Orthopaedics and Related Research , Issue.464 , pp. 83-87
    • Gioe, T.J.1    Novak, C.2    Sinner, P.3    Ma, W.4    Mehle, S.5
  • 7
    • 34250223372 scopus 로고    scopus 로고
    • Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
    • DOI 10.2106/JBJS.F.00667
    • Collier MB, Engh CA Jr, McAuley JP, Engh GA. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J. Bone Joint Surg. Am. 89(6), 1306-1314 (2007). (Pubitemid 46898003)
    • (2007) Journal of Bone and Joint Surgery - Series A , vol.89 , Issue.6 , pp. 1306-1314
    • Collier, M.B.1    Engh Jr., C.A.2    McAuley, J.P.3    Engh, G.A.4
  • 9
    • 0242694079 scopus 로고    scopus 로고
    • An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty
    • Laskin RS. An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty. Clin. Orthop. Relat. Res. 416, 191-196 (2003). (Pubitemid 37413639)
    • (2003) Clinical Orthopaedics and Related Research , Issue.416 , pp. 191-196
    • Laskin, R.S.1
  • 11
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J. Bone Joint Surg. Am. 74(6), 849-863 (1992).
    • (1992) J. Bone Joint Surg. Am. , vol.74 , Issue.6 , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 12
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • DOI 10.1054/arth.2002.33664
    • Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J. Arthroplasty 17(5), 649-661 (2002). (Pubitemid 34864348)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.5 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.A.3
  • 13
    • 18244404013 scopus 로고    scopus 로고
    • Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose-response relationship
    • DOI 10.1016/j.orthres.2004.11.005, PII S0736026604002530
    • Wilkinson JM, Hamer AJ, Stockley I, Eastell R. Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose-response relationship. J. Orthop. Res. 23(3), 520-525 (2005). (Pubitemid 40631321)
    • (2005) Journal of Orthopaedic Research , vol.23 , Issue.3 , pp. 520-525
    • Wilkinson, J.M.1    Hamer, A.J.2    Stockley, I.3    Eastell, R.4
  • 14
    • 58649111026 scopus 로고    scopus 로고
    • Fixed and mobile bearing total knee arthroplasty-influence on wear generation, corresponding wear areas, knee kinematics and particle composition
    • Grupp TM, Kaddick C, Schwiesau J, Maas A, Stulberg SD. Fixed and mobile bearing total knee arthroplasty-influence on wear generation, corresponding wear areas, knee kinematics and particle composition. Clin. Biomech. 24(2), 210-217 (2009).
    • (2009) Clin. Biomech. , vol.24 , Issue.2 , pp. 210-217
    • Grupp, T.M.1    Kaddick, C.2    Schwiesau, J.3    Maas, A.4    Stulberg, S.D.5
  • 15
    • 28544441161 scopus 로고    scopus 로고
    • Polymer insert stress in total knee designs during high-flexion activities: A finite element study
    • DOI 10.2106/JBJS.E.00436
    • Morra EA, Greenwald AS. Polymer insert stress in total knee designs during high-flexion activities: A finite element study. J. Bone Joint Surg. Am. 87(Suppl. 2), 120-124 (2005). (Pubitemid 41747023)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.12 SUPPL. , pp. 120-124
    • Morra, E.A.1    Greenwald, A.S.2
  • 16
    • 10444261188 scopus 로고    scopus 로고
    • The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    • DOI 10.1016/j.jbiomech.2004.02.015, PII S002192900400096X
    • McEwen HM, Barnett PI, Bell CJ et al. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J. Biomech. 38(2), 357-365 (2005). (Pubitemid 39642958)
    • (2005) Journal of Biomechanics , vol.38 , Issue.2 , pp. 357-365
    • McEwen, H.M.J.1    Barnett, P.I.2    Bell, C.J.3    Farrar, R.4    Auger, D.D.5    Stone, M.H.6    Fisher, J.7
  • 17
    • 0036903450 scopus 로고    scopus 로고
    • Cemented ceramic YMCK total knee arthroplasty in patients with severe rheumatoid arthritis
    • DOI 10.1054/arth.2002.35826
    • Koshino T, Okamoto R, Takagi T, Yamamoto K, Saito T. Cemented ceramic YMCK total knee arthroplasty in patients with severe rheumatoid arthritis. J. Arthroplasty 17(8), 1009-1015 (2002). (Pubitemid 35462943)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.8 , pp. 1009-1015
    • Koshino, T.1    Okamoto, R.2    Takagi, T.3    Yamamoto, K.4    Saito, T.5
  • 18
    • 34249748817 scopus 로고    scopus 로고
    • A review of ceramic bearing materials in total joint arthroplasty
    • Bal BS, Garino J, Ries M, Rahaman MN. A review of ceramic bearing materials in total joint arthroplasty. Hip Int. 17(1), 21-30 (2007). (Pubitemid 46824569)
    • (2007) HIP International , vol.17 , Issue.1 , pp. 21-30
    • Bal, B.S.1    Garino, J.2    Ries, M.3    Rahaman, M.N.4
  • 19
    • 84864393600 scopus 로고    scopus 로고
    • Mid-term clinical results of alumina medial pivot total knee arthroplasty
    • doi:10.1007/s00167-011-1734-13 (Epub ahead of print
    • Iida T, Minoda Y, Kadoya Y et al. Mid-term clinical results of alumina medial pivot total knee arthroplasty. Knee Surg. Sports Traumatol. Arthrosc. doi:10.1007/s00167-011-1734-3 (2011) (Epub ahead of print).
    • (2011) Knee Surg. Sports Traumatol. Arthrosc.
    • Iida, T.1    Minoda, Y.2    Kadoya, Y.3
  • 20
    • 79954578031 scopus 로고    scopus 로고
    • Total knee replacement with ceramic femoral components: A national prospective multicenter study of clinical and radiological outcomes
    • Bergschmidt P, Lohmann C, Ganzer D et al. Total knee replacement with ceramic femoral components: A national prospective multicenter study of clinical and radiological outcomes. Orthopade 40(3), 224-230 (2011).
    • (2011) Orthopade , vol.40 , Issue.3 , pp. 224-230
    • Bergschmidt, P.1    Lohmann, C.2    Ganzer, D.3
  • 21
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • Davidson JA. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clin. Orthop. Relat. Res. 294, 361-378 (1993). (Pubitemid 23277129)
    • (1993) Clinical Orthopaedics and Related Research , Issue.294 , pp. 361-378
    • Davidson, J.A.1
  • 22
    • 0031106697 scopus 로고    scopus 로고
    • Tribological evaluation of oxidized zirconium using an articular cartilage counterface: A novel material for potential use in hemiarthroplasty
    • DOI 10.1016/S0142-9612(96)00152-4, PII S0142961296001524
    • Patel AM, Spector M. Tribological evaluation of oxidized zirconium using an articular cartilage counterface: A novel material for potential use in hemiarthroplasty. Biomaterials 18(5), 441-447 (1997). (Pubitemid 27095592)
    • (1997) Biomaterials , vol.18 , Issue.5 , pp. 441-447
    • Patel, A.M.1    Spector, M.2
  • 26
    • 0028249007 scopus 로고
    • Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris
    • Davidson JA, Poggie RA, Mishra AK. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed. Mater. Eng. 4(3), 213-229 (1994).
    • (1994) Biomed. Mater. Eng. , vol.4 , Issue.3 , pp. 213-229
    • Davidson, J.A.1    Poggie, R.A.2    Mishra, A.K.3
  • 27
    • 0035175965 scopus 로고    scopus 로고
    • Wear performance of ultra-high molecular weight polyethylene, on oxidized zirconium total knee femoral components
    • Spector BM, Ries MD, Bourne RB, Sauer WS, Long M, Hunter G. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J. Bone Joint Surg. Am. 83-A(Suppl. 2 Pt. 2), 80-86 (2001). (Pubitemid 33070036)
    • (2001) Journal of Bone and Joint Surgery - Series A , vol.83 , Issue.SUPPL. 2 , pp. 80-86
    • Spector, M.1    Ries, M.D.2    Bourne, R.B.3    Sauer, W.S.4    Long, M.5    Hunter, G.6
  • 29
    • 0023425006 scopus 로고
    • The role of counterface imperfections in the wear of polyethylene
    • Dowson D, Taheri S, Wallbridge N. The role of counterface imperfections in the wear of polyethylene. Wear 119, 277-293 (1987).
    • (1987) Wear , vol.119 , pp. 277-293
    • Dowson, D.1    Taheri, S.2    Wallbridge, N.3
  • 30
    • 84865517193 scopus 로고    scopus 로고
    • Bellemans J Ries MD Victor J (Eds). Springer-Verlag, Heidelberg, Germany
    • Hunter G, Jones WM, Spector M. Oxidized Zirconium. Bellemans J, Ries MD, Victor J (Eds). Springer-Verlag, Heidelberg, Germany (2005).
    • (2005) Oxidized Zirconium
    • Hunter, G.1    Jones, W.M.2    Spector, M.3
  • 31
  • 32
    • 0036394796 scopus 로고    scopus 로고
    • Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions
    • Ries MD, Salehi A, Widding K, Hunter G. Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions. J. Bone Joint Surg. Am. 84-A(Suppl. 2), 129-135 (2002). (Pubitemid 35168347)
    • (2002) Journal of Bone and Joint Surgery - Series A , vol.84 , Issue.SUPPL. 2 , pp. 129-135
    • Ries, M.D.1    Salehi, A.2    Widding, K.3    Hunter, G.4
  • 33
    • 36348971818 scopus 로고    scopus 로고
    • UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation
    • DOI 10.1016/j.wear.2007.03.020, PII S0043164807004917
    • DesJardins J, Burnikel B, LaBerge M. UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation. Wear 264, 245-256 (2008). (Pubitemid 350151491)
    • (2008) Wear , vol.264 , Issue.3-4 , pp. 245-256
    • DesJardins, J.D.1    Burnikel, B.2    LaBerge, M.3
  • 35
    • 0141889873 scopus 로고    scopus 로고
    • Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts
    • DOI 10.1016/S0883-5403(03)00293-6
    • Muratoglu OK, Ruberti J, Melotti S, Spiegelberg SH, Greenbaum ES, Harris WH. Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts. J. Arthroplasty 18(7 Suppl. 1), 42-47 (2003). (Pubitemid 37259665)
    • (2003) Journal of Arthroplasty , vol.18 , Issue.7 SUPPL. 1 , pp. 42-47
    • Muratoglu, O.K.1    Ruberti, J.2    Melotti, S.3    Spiegelberg, S.H.4    Greenbaum, E.S.5    Harris, W.H.6
  • 37
    • 79953054058 scopus 로고    scopus 로고
    • Retrieval analysis of femoral zirconium components in total knee arthroplasty preliminary results
    • Heyse TJ, Davis J, Haas SB, Chen DX, Wright TM, Laskin RS. Retrieval analysis of femoral zirconium components in total knee arthroplasty preliminary results. J. Arthroplasty 6(3), 445-450 (2010).
    • (2010) J. Arthroplasty , vol.6 , Issue.3 , pp. 445-450
    • Heyse, T.J.1    Davis, J.2    Haas, S.B.3    Chen, D.X.4    Wright, T.M.5    Laskin, R.S.6
  • 38
    • 35848931476 scopus 로고    scopus 로고
    • PFC knee replacement: Osteolytic failures from extreme polyethylene degradation
    • DOI 10.1097/BLO.0b013e3181591c62, PII 0000308620071100000026
    • Casey D, Cottrell J, DiCarlo E, Windsor R, Wright T. PFC knee replacement: Osteolytic failures from extreme polyethylene degradation. Clin. Orthop. Relat. Res. 464, 157-163 (2007). (Pubitemid 350059962)
    • (2007) Clinical Orthopaedics and Related Research , Issue.464 , pp. 157-163
    • Casey, D.1    Cottrell, J.2    DiCarlo, E.3    Windsor, R.4    Wright, T.5
  • 40
    • 82455192535 scopus 로고    scopus 로고
    • Matched-pair total knee arthroplasty retrieval analysis: Oxidized zirconium vs. CoCrMo
    • Heyse TJ, Chen DX, Kelly N, Boettner F, Wright TM, Haas SB. Matched-pair total knee arthroplasty retrieval analysis: Oxidized zirconium vs. CoCrMo. Knee 18(6), 448-452 (2011).
    • (2011) Knee , vol.18 , Issue.6 , pp. 448-452
    • Heyse, T.J.1    Chen, D.X.2    Kelly, N.3    Boettner, F.4    Wright, T.M.5    Haas, S.B.6
  • 41
    • 79953851313 scopus 로고    scopus 로고
    • Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: A randomized controlled trial
    • Hui C, Salmon L, Maeno S, Roe J, Walsh W, Pinczewski L. Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: A randomized controlled trial. J. Bone Joint Surg. Am. 93(7), 624-630 (2011).
    • (2011) J. Bone Joint Surg. Am. , vol.93 , Issue.7 , pp. 624-630
    • Hui, C.1    Salmon, L.2    Maeno, S.3    Roe, J.4    Walsh, W.5    Pinczewski, L.6
  • 42
    • 77953293114 scopus 로고    scopus 로고
    • Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses
    • Kim YH, Kim JS, Huh W, Lee KH. Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses. Clin. Orthop. Relat. Res. 468(5), 1296-1304 (2010).
    • (2010) Clin. Orthop. Relat. Res. , vol.468 , Issue.5 , pp. 1296-1304
    • Kim, Y.H.1    Kim, J.S.2    Huh, W.3    Lee, K.H.4
  • 46
    • 77956634840 scopus 로고    scopus 로고
    • Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty
    • Garrett S, Jacobs N, Yates P, Smith A, Wood D. Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty. Acta Orthop. Belg. 76(4), 513-520 (2010).
    • (2010) Acta Orthop. Belg. , vol.76 , Issue.4 , pp. 513-520
    • Garrett, S.1    Jacobs, N.2    Yates, P.3    Smith, A.4    Wood, D.5
  • 47
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • DOI 10.1016/S0736-0266(02)00152-3, PII S0736026602001523
    • Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymüller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-onmetal total hip replacements. J. Orthop. Res. 21(2), 189-195 (2003). (Pubitemid 36322536)
    • (2003) Journal of Orthopaedic Research , vol.21 , Issue.2 , pp. 189-195
    • Lhotka, C.1    Szekeres, T.2    Steffan, I.3    Zhuber, K.4    Zweymuller, K.5
  • 48
    • 84856364085 scopus 로고    scopus 로고
    • Metal hypersensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component-A case report
    • Bergschmidt P, Bader R, Mittelmeier W. Metal hypersensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component-a case report. Knee 19(2), 144-147 (2012).
    • (2012) Knee , vol.19 , Issue.2 , pp. 144-147
    • Bergschmidt, P.1    Bader, R.2    Mittelmeier, W.3
  • 49
    • 65349166709 scopus 로고    scopus 로고
    • Intolerance reactions to knee arthroplasty in patients with nickel/cobalt allergy and disappearance of symptoms after revision surgery with titanium-based endoprostheses
    • Dietrich KA, Mazoochian F, Summer B, Reinert M, Ruzicka T, Thomas P. Intolerance reactions to knee arthroplasty in patients with nickel/cobalt allergy and disappearance of symptoms after revision surgery with titanium-based endoprostheses. J. Dtsch. Dermatol. Ges. 7(5), 410-413 (2009).
    • (2009) J. Dtsch. Dermatol. Ges. , vol.7 , Issue.5 , pp. 410-413
    • Dietrich, K.A.1    Mazoochian, F.2    Summer, B.3    Reinert, M.4    Ruzicka, T.5    Thomas, P.6
  • 50
    • 38549138363 scopus 로고    scopus 로고
    • Sensitivity to implant materials in patients with total knee arthroplasties
    • Granchi D, Cenni E, Tigani D, Trisolino G, Baldini N, Giunti A. Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials 29(10), 1494-1500 (2008).
    • (2008) Biomaterials , vol.29 , Issue.10 , pp. 1494-1500
    • Granchi, D.1    Cenni, E.2    Tigani, D.3    Trisolino, G.4    Baldini, N.5    Giunti, A.6
  • 51
    • 80051925766 scopus 로고    scopus 로고
    • Pain in a chromium-allergic patient with total knee arthroplasty: Disappearance of symptoms after revision with a special surface-coated TKA-A case report
    • Thomsen M, Rozak M, Thomas P. Pain in a chromium-allergic patient with total knee arthroplasty: Disappearance of symptoms after revision with a special surface-coated TKA-a case report. Acta Orthop. 82(3), 386-388 (2011).
    • (2011) Acta Orthop , vol.82 , Issue.3 , pp. 386-388
    • Thomsen, M.1    Rozak, M.2    Thomas, P.3
  • 52
    • 34548231653 scopus 로고    scopus 로고
    • Ten-year results of the first 100 genesis II total knee replacement procedures
    • Bourne RB, Laskin RS, Guerin JS. Ten-year results of the first 100 Genesis II total knee replacement procedures. Orthopedics 30(Suppl. 8), 83-85 (2007). (Pubitemid 47322677)
    • (2007) Orthopedics , vol.30 , Issue.8 SUPPL. , pp. 83-85
    • Bourne, R.B.1    Laskin, R.S.2    Guerin, J.S.3
  • 53
    • 0030143348 scopus 로고    scopus 로고
    • Chemical and electrochemical aspects of the biocompatibility of titanium and its alloys
    • Brown SA, Lemons JE (Eds), West Conshohocken, PA, USA
    • Kovacs P, Davidson JA. Chemical and Electrochemical Aspects of the Biocompatibility of Titanium and its Alloys. Brown SA, Lemons JE (Eds). American Society for Testing and Materials (ASTM STP 1272), West Conshohocken, PA, USA (1996).
    • (1996) American Society for Testing and Materials (ASTM STP 1272
    • Kovacs, P.1    Davidson, J.A.2
  • 54
    • 84865517192 scopus 로고
    • Zirconia (ZrO2)-Coated Zirconium-2.5Nb alloy for prosthetic knee nearing applications
    • Yamamuro T, Kokubo T, Nakamura T (Eds), Kyoto, Japan
    • Davidson JA, Asgian CM, Mishra AK, Kovacs P. Zirconia (ZrO2)-Coated Zirconium-2.5Nb Alloy for Prosthetic Knee Nearing Applications. Yamamuro T, Kokubo T, Nakamura T (Eds). Kobunshi Kankokai, Kyoto, Japan (1992).
    • (1992) Kobunshi Kankokai
    • Davidson, J.A.1    Asgian, C.M.2    Mishra, A.K.3    Kovacs, P.4
  • 56
    • 33745905323 scopus 로고    scopus 로고
    • Metal artifact reduction in musculoskeletal magnetic resonance imaging
    • DOI 10.1016/j.ocl.2006.04.001, PII S0030589806000186, Advances in Musculoskeletal Imaging
    • Harris CA, White LM. Metal artifact reduction in musculoskeletal magnetic resonance imaging. Orthop. Clin. North Am. 37(3), 349-359 (2006). (Pubitemid 44041515)
    • (2006) Orthopedic Clinics of North America , vol.37 , Issue.3 , pp. 349-359
    • Harris, C.A.1    White, L.M.2
  • 57
    • 33745901934 scopus 로고    scopus 로고
    • Magnetic resonance imaging of joint arthroplasty
    • DOI 10.1016/j.ocl.2006.03.003, PII S0030589806000162, Advances in Musculoskeletal Imaging
    • Potter HG, Foo LF. Magnetic resonance imaging of joint arthroplasty. Orthop. Clin. North Am. 37(3), 361-373 (2006). (Pubitemid 44041513)
    • (2006) Orthopedic Clinics of North America , vol.37 , Issue.3 , pp. 361-373
    • Potter, H.G.1    Foo, L.F.2
  • 59
    • 0345830059 scopus 로고    scopus 로고
    • Metallic artefacts in MR imaging: Effects of main field orientation and strength
    • DOI 10.1016/S0009-9260(02)00540-8
    • Guermazi A, Miaux Y, Zaim S, Peterfy CG, White D, Genant HK. Metallic artifacts in MR imaging: Effects of main field orientation and strength. Clin. Radiol. 58(4), 322-328 (2003). (Pubitemid 36416977)
    • (2003) Clinical Radiology , vol.58 , Issue.4 , pp. 322-328
    • Guermazi, A.1    Miaux, Y.2    Zaim, S.3    Peterfy, C.G.4    White, D.5    Genant, H.K.6
  • 60
    • 33745481078 scopus 로고    scopus 로고
    • MRI comparison of periprosthetic structures around zirconium knee prostheses and cobalt chrome prostheses
    • DOI 10.2214/AJR.05.1077
    • Raphael B, Haims AH, Wu JS, Katz LD, White LM, Lynch K. MRI comparison of periprosthetic structures around zirconium knee prostheses and cobalt chrome prostheses. AJR. Am. J. Roentgenol. 186(6), 1771-1777 (2006). (Pubitemid 46112544)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.6 , pp. 1771-1777
    • Raphael, B.1    Haims, A.H.2    Wu, J.S.3    Katz, L.D.4    White, L.M.5    Lynch, K.6
  • 63
    • 33646058250 scopus 로고    scopus 로고
    • Magnetic resonance imaging to evaluate osteolysis around total knee arthroplasty
    • Mosher TJ, Davis CM 3rd. Magnetic resonance imaging to evaluate osteolysis around total knee arthroplasty. J. Arthroplasty 21(3), 460-463 (2006).
    • (2006) J. Arthroplasty , vol.21 , Issue.3 , pp. 460-463
    • Mosher, T.J.1    Davis III, C.M.2
  • 64
    • 33747876773 scopus 로고    scopus 로고
    • Magnetic resonance imaging with metal suppression for evaluation of periprosthetic osteolysis after total knee arthroplasty
    • DOI 10.1016/j.arth.2005.10.017, PII S088354030500656X
    • Vessely MB, Frick MA, Oakes D, Wenger DE, Berry DJ. Magnetic resonance imaging with metal suppression for evaluation of periprosthetic osteolysis after total knee arthroplasty. J. Arthroplasty 21(6), 826-831 (2006). (Pubitemid 44293234)
    • (2006) Journal of Arthroplasty , vol.21 , Issue.6 , pp. 826-831
    • Vessely, M.B.1    Frick, M.A.2    Oakes, D.3    Wenger, D.E.4    Berry, D.J.5
  • 66
    • 84865390243 scopus 로고    scopus 로고
    • MRI analysis for rotation of total knee components
    • doi:10.1016/j.knee.2012.01.003 (Epub ahead of print
    • Heyse TJ, Chong LR, Davis J, Boettner F, Haas SB, Potter HG. MRI analysis for rotation of total knee components. Knee doi:10.1016/j.knee.2012.01.003 (2012) (Epub ahead of print).
    • (2012) Knee
    • Heyse, T.J.1    Chong, L.R.2    Davis, J.3    Boettner, F.4    Haas, S.B.5    Potter, H.G.6
  • 67
    • 69049089778 scopus 로고    scopus 로고
    • Magnetic resonance imaging of in vivo patellofemoral kinematics after total knee arthroplasty
    • Carpenter RD, Brilhault J, Majumdar S, Ries MD. Magnetic resonance imaging of in vivo patellofemoral kinematics after total knee arthroplasty. Knee 16(5), 332-336 (2009).
    • (2009) Knee , vol.16 , Issue.5 , pp. 332-336
    • Carpenter, R.D.1    Brilhault, J.2    Majumdar, S.3    Ries, M.D.4
  • 68
    • 77950333286 scopus 로고    scopus 로고
    • Experimental MR imaging of zirconia ceramic joint implants at 1.5 and 3 T
    • Kamishima T, Kitamura N, Amemiya M et al. Experimental MR imaging of zirconia ceramic joint implants at 1.5 and 3 T. Clin. Radiol. 65(5), 387-390 (2010).
    • (2010) Clin. Radiol. , vol.65 , Issue.5 , pp. 387-390
    • Kamishima, T.1    Kitamura, N.2    Amemiya, M.3
  • 69
    • 34547572936 scopus 로고    scopus 로고
    • Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies
    • DOI 10.1016/j.arth.2006.07.005, PII S0883540306005225
    • Kop AM, Whitewood C, Johnston DJ. Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies. J. Arthroplasty 22(5), 775-779 (2007). (Pubitemid 47198425)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.5 , pp. 775-779
    • Kop, A.M.1    Whitewood, C.2    Johnston, D.J.L.3
  • 70
    • 78951476291 scopus 로고    scopus 로고
    • Do 'premium' joint implants add value?: Analysis of high cost joint implants in a community registry
    • Gioe TJ, Sharma A, Tatman P, Mehle S. Do 'premium' joint implants add value?: Analysis of high cost joint implants in a community registry. Clin. Orthop. Relat. Res. 469(1), 48-54 (2011).
    • (2011) Clin. Orthop. Relat. Res. , vol.469 , Issue.1 , pp. 48-54
    • Gioe, T.J.1    Sharma, A.2    Tatman, P.3    Mehle, S.4
  • 71
    • 84865507316 scopus 로고    scopus 로고
    • Knee implant recall hits Smith & Nephew
    • 18th September
    • Gibbs G. Knee implant recall hits Smith & Nephew. The Guardian, 18th September (2003).
    • (2003) The Guardian
    • Gibbs, G.1
  • 73
    • 46449131023 scopus 로고    scopus 로고
    • Mittelfristige radiologische ergebnisse nach bikondylärem ungekoppeltem kniegelenkersatz mit femurkomponenten aus zirkonium und chrom-kobalt
    • DOI 10.1055/s-2007-989293
    • Göbel F, Ulbricht S, Hein W, Bernstein A. Radiological mid-term results of total knee arthroplasty with femoral components of different materials. Z. Orthop. Unfall. 146(2), 194-199 (2008). (Pubitemid 351959735)
    • (2008) Zeitschrift fur Orthopadie und Unfallchirurgie , vol.146 , Issue.2 , pp. 194-199
    • Gobel, F.1    Ulbricht, S.2    Hein, W.3    Bernstein, A.4
  • 74
    • 27644529435 scopus 로고    scopus 로고
    • Ability of zirconia double coated with titanium and hydroxyapatite to bond to bone under load-bearing conditions
    • DOI 10.1016/j.biomaterials.2005.07.026, PII S0142961205006678
    • Suzuki T, Fujibayashi S, Nakagawa Y, Noda I, Nakamura T. Ability of zirconia double coated with titanium and hydroxyapatite to bond to bone under load-bearing conditions. Biomaterials 27(7), 996-1002 (2006). (Pubitemid 41566691)
    • (2006) Biomaterials , vol.27 , Issue.7 , pp. 996-1002
    • Suzuki, T.1    Fujibayashi, S.2    Nakagawa, Y.3    Noda, I.4    Nakamura, T.5
  • 75
    • 62249103643 scopus 로고    scopus 로고
    • Biomechanical and histological behavior of zirconia implants: An experiment in the rat
    • Kohal RJ, Wolkewitz M, Hinze M, Han JS, Bachle M, Butz F. Biomechanical and histological behavior of zirconia implants: An experiment in the rat. Clin. Oral Implants Res. 20(4), 333-339 (2009).
    • (2009) Clin. Oral Implants Res. , vol.20 , Issue.4 , pp. 333-339
    • Kohal, R.J.1    Wolkewitz, M.2    Hinze, M.3    Han, J.S.4    Bachle, M.5    Butz, F.6
  • 78
    • 54449099240 scopus 로고    scopus 로고
    • Rotating platform versus fixed-bearing total knees: An in vitro study of wear
    • Haider H, Garvin K. Rotating platform versus fixed-bearing total knees: An in vitro study of wear. Clin. Orthop. Relat. Res. 466(11), 2677-2685 (2008).
    • (2008) Clin. Orthop. Relat. Res. , vol.466 , Issue.11 , pp. 2677-2685
    • Haider, H.1    Garvin, K.2
  • 79
    • 33947712100 scopus 로고    scopus 로고
    • Simulated Normal Gait Wear Testing of a Highly Cross-Linked Polyethylene Tibial Insert
    • DOI 10.1016/j.arth.2006.07.014, PII S0883540306006309
    • Muratoglu OK, Rubash HE, Bragdon CR, Burroughs BR, Huang A, Harris WH. Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert. J. Arthroplasty 22(3), 435-444 (2007). (Pubitemid 46505219)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.3 , pp. 435-444
    • Muratoglu, O.K.1    Rubash, H.E.2    Bragdon, C.R.3    Burroughs, B.R.4    Huang, A.5    Harris, W.H.6
  • 80
    • 4644220738 scopus 로고    scopus 로고
    • Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts
    • DOI 10.1016/j.arth.2004.03.019, PII S088354030400316X
    • Muratoglu OK, Bragdon CR, Jasty M, O'Connor DO, Von Knoch RS, Harris WH. Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts. J. Arthroplasty 19(7), 887-897 (2004). (Pubitemid 39304234)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.7 , pp. 887-897
    • Muratoglu, O.K.1    Bragdon, C.R.2    Jasty, M.3    O'Connor, D.O.4    Von Knoch, R.S.5    Harris, W.H.6
  • 82
    • 0037024111 scopus 로고    scopus 로고
    • Polyethylene wear characteristics in vivo and in a knee stimulator
    • Beaulé PE, Campbell PA, Walker PS et al. Polyethylene wear characteristics in vivo and in a knee stimulator. J. Biomed. Mater. Res. 60(3), 411-419 (2002).
    • (2002) J. Biomed. Mater. Res. , vol.60 , Issue.3 , pp. 411-419
    • Beaulé, P.E.1    Campbell, P.A.2    Walker, P.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.