메뉴 건너뛰기




Volumn 38, Issue 2, 2005, Pages 357-365

The influence of design, materials and kinematics on the in vitro wear of total knee replacements

Author keywords

Knee kinematics; Knee simulator; Polyethylene wear; Total knee replacement

Indexed keywords

CROSSLINKING; KINEMATICS; PROSTHETICS; ROTATION; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 10444261188     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2004.02.015     Document Type: Article
Times cited : (287)

References (20)
  • 3
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel D.L., Bicknell V.L., Wright T.M. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. The Journal of Bone and Joint Surgery. 68-A(7):1986;1041-1051
    • (1986) The Journal of Bone and Joint Surgery , vol.68 , Issue.7 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 5
    • 0006169368 scopus 로고    scopus 로고
    • Assessment of backside polyethylene wear in three different metal backed total knee designs
    • Orthopaedic Research Society, Anaheim, California, 1-4 February 1999
    • Furman, B.D., Schmieg, J.J., Bhattacharyya, S., Li, S., 1999. Assessment of backside polyethylene wear in three different metal backed total knee designs. Transactions 45th Annual Meeting, Orthopaedic Research Society, Anaheim, California, 1-4 February 1999, p. 149.
    • (1999) Transactions 45th Annual Meeting , pp. 149
    • Furman, B.D.1    Schmieg, J.J.2    Bhattacharyya, S.3    Li, S.4
  • 6
    • 0034947632 scopus 로고    scopus 로고
    • Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants
    • Howling G.I., Barnett P.I., Tipper J.L., Stone M.H., Fisher J., Ingham E. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants. Journal of Biomedical Materials Research. 58:2001;415-420
    • (2001) Journal of Biomedical Materials Research , vol.58 , pp. 415-420
    • Howling, G.I.1    Barnett, P.I.2    Tipper, J.L.3    Stone, M.H.4    Fisher, J.5    Ingham, E.6
  • 9
    • 0035482037 scopus 로고    scopus 로고
    • The effect of displacement control input parameters on tibiofemoral prosthetic knee wear
    • Johnson T.S., Laurent M.P., Yao J.Q., Gilbertson L.N. The effect of displacement control input parameters on tibiofemoral prosthetic knee wear. Wear. 250:2001;222-226
    • (2001) Wear , vol.250 , pp. 222-226
    • Johnson, T.S.1    Laurent, M.P.2    Yao, J.Q.3    Gilbertson, L.N.4
  • 12
    • 0032854175 scopus 로고    scopus 로고
    • Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene
    • Marrs H., Barton D.C., Jones R.A., Ward I.M., Fisher J., Doyle C. Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene. Journal of Material Science: Materials in Medicine. 10:1999;333-342
    • (1999) Journal of Material Science: Materials in Medicine , vol.10 , pp. 333-342
    • Marrs, H.1    Barton, D.C.2    Jones, R.A.3    Ward, I.M.4    Fisher, J.5    Doyle, C.6
  • 13
    • 10444229756 scopus 로고    scopus 로고
    • Extremely low wear of gamma-crosslinked/remelted UHMW polyethylene acetabular cups
    • Orthopaedic Research Society, Dallas, TX, 10-13 February 2002
    • McKellop, H., Shen, F.-W., Salovey, R., 1998. Extremely low wear of gamma-crosslinked/remelted UHMW polyethylene acetabular cups. Transactions 48th Annual Meeting, Orthopaedic Research Society, Dallas, TX, 10-13 February 2002, p. 946.
    • (1998) Transactions 48th Annual Meeting , pp. 946
    • McKellop, H.1    Shen, F.-W.2    Salovey, R.3
  • 14
    • 0035100880 scopus 로고    scopus 로고
    • Loosening and osteolysis with the press-fit condylar posterior-cruciate- substituting total knee replacement
    • Mikulak S.A., Mahoney O.M., Dela Rosa M.A., Schmalzried T.P. Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement. The Journal of Bone and Joint Surgery. 83-A(3):2001;398-403
    • (2001) The Journal of Bone and Joint Surgery , vol.83 , Issue.3 , pp. 398-403
    • Mikulak, S.A.1    Mahoney, O.M.2    Dela Rosa, M.A.3    Schmalzried, T.P.4
  • 15
    • 0001093632 scopus 로고
    • Friction and molecular structure: The behaviour of some thermoplastics
    • Pooley C.M., Tabor D. Friction and molecular structure. the behaviour of some thermoplastics Proceedings Royal Society London A. 329:1972;251-274
    • (1972) Proceedings Royal Society London a , vol.329 , pp. 251-274
    • Pooley, C.M.1    Tabor, D.2
  • 17
    • 0031720017 scopus 로고    scopus 로고
    • Total knee arthroplasty with the PFC system: Results at a minimum of 10 years and survivorship analysis
    • Schai P.A., Thornhill T.S., Scott R.D. Total knee arthroplasty with the PFC system. results at a minimum of 10 years and survivorship analysis The Journal of Bone and Joint Surgery. 80-B(5):1998;850-858
    • (1998) The Journal of Bone and Joint Surgery , vol.80 , Issue.5 , pp. 850-858
    • Schai, P.A.1    Thornhill, T.S.2    Scott, R.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.