메뉴 건너뛰기




Volumn 146, Issue 2, 2008, Pages 194-199

Radiological mid-term results of total knee arthroplasty with femoral components of different materials;Mittelfristige radiologische ergebnisse nach bikondylärem ungekoppeltem kniegelenkersatz mit femurkomponenten aus zirkonium und chrom-kobalt

Author keywords

Radiolucent line; Total knee arthroplasty; Zirconium

Indexed keywords

CHROMIUM; COBALT; POLYETHYLENE; ZIRCONIUM; NIOBIUM; VITALLIUM; ZIRCONIUM OXIDE;

EID: 46449131023     PISSN: 1864-669     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-989293     Document Type: Article
Times cited : (9)

References (55)
  • 1
    • 0035117514 scopus 로고    scopus 로고
    • Survival analysis of cemented Press-Fit Condylar total knee arthroplasty
    • Khaw FM, Kirk LM, Gregg PJ. Survival analysis of cemented Press-Fit Condylar total knee arthroplasty. J Arthroplasty 2001; 16: 161-167
    • (2001) J Arthroplasty , vol.16 , pp. 161-167
    • Khaw, F.M.1    Kirk, L.M.2    Gregg, P.J.3
  • 2
    • 0028146320 scopus 로고
    • Cementless meniscal bearing knee arthroplasty: 7- to 12-year outcome analysis
    • Buechel FF. Cementless meniscal bearing knee arthroplasty: 7- to 12-year outcome analysis. Orthopedics 1994; 17: 833-836
    • (1994) Orthopedics , vol.17 , pp. 833-836
    • FF, B.1
  • 3
    • 0032430761 scopus 로고    scopus 로고
    • Revision of failed cementless total knee implants with cement
    • Fehring TK, Griffin WL. Revision of failed cementless total knee implants with cement. Clin Orthop Relat Res 1998; 356: 34-38
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 34-38
    • Fehring, T.K.1    Griffin, W.L.2
  • 4
    • 0028598169 scopus 로고
    • Impact of modern technique on long-term results of total condylar knee arthroplasty
    • Ranawat CS, Flynn Jr WF, Deshmukh RG. Impact of modern technique on long-term results of total condylar knee arthroplasty. Clin Orthop Relat Res 1994; 309: 131-135
    • (1994) Clin Orthop Relat Res , vol.309 , pp. 131-135
    • Ranawat, C.S.1    Flynn Jr, W.F.2    Deshmukh, R.G.3
  • 5
    • 33646442225 scopus 로고    scopus 로고
    • The press-fit condylar modular total knee system with a posterior cruciate-substituting design. A concise follow-up of a previous report
    • Am
    • Rasquinha VJ, Ranawat CS, Cervieri CL, Rodriguez JA. The press-fit condylar modular total knee system with a posterior cruciate-substituting design. A concise follow-up of a previous report. J Bone Joint Surg [Am] 2006; 88: 1006-1010
    • (2006) J Bone Joint Surg , vol.88 , pp. 1006-1010
    • Rasquinha, V.J.1    Ranawat, C.S.2    Cervieri, C.L.3    Rodriguez, J.A.4
  • 6
    • 0034762231 scopus 로고    scopus 로고
    • The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41223 knees operated on in 1988-1997
    • Robertsson O, Knutson K, Lewold S, Lidgren L. The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41223 knees operated on in 1988-1997. Acta Orthop Scand 2001; 72: 503-513
    • (2001) Acta Orthop Scand , vol.72 , pp. 503-513
    • Robertsson, O.1    Knutson, K.2    Lewold, S.3    Lidgren, L.4
  • 7
    • 0032797653 scopus 로고    scopus 로고
    • Prodromes of failure in total knee arthroplasty
    • Lonner JH, Siliski JM, Scott RD. Prodromes of failure in total knee arthroplasty. J Arthroplasty 1999; 14: 488-492
    • (1999) J Arthroplasty , vol.14 , pp. 488-492
    • Lonner, J.H.1    Siliski, J.M.2    Scott, R.D.3
  • 8
    • 0031718703 scopus 로고    scopus 로고
    • The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs
    • Bert JM, Reuben J, Kelly F, Gross M, Elting F. The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs. J Arthroplasty 1998; 13: 609-614
    • (1998) J Arthroplasty , vol.13 , pp. 609-614
    • Bert, J.M.1    Reuben, J.2    Kelly, F.3    Gross, M.4    Elting, F.5
  • 9
    • 12644279879 scopus 로고    scopus 로고
    • An analysis of Food and Drug Administration medical device reports relating to total joint components
    • Castro FP, Chimento G, Munn B, Levy R, Timon S, Barrack R. An analysis of Food and Drug Administration medical device reports relating to total joint components. J Arthroplasty 1997; 12: 765-771
    • (1997) J Arthroplasty , vol.12 , pp. 765-771
    • Castro, F.P.1    Chimento, G.2    Munn, B.3    Levy, R.4    Timon, S.5    Barrack, R.6
  • 11
    • 0034036811 scopus 로고    scopus 로고
    • Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components
    • Am
    • Engh GA, Koralewicz LM, Pereles TR. Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components. J Bone Joint Surg [Am] 2000; 82: 516-523
    • (2000) J Bone Joint Surg , vol.82 , pp. 516-523
    • Engh, G.A.1    Koralewicz, L.M.2    Pereles, T.R.3
  • 13
    • 0030895456 scopus 로고    scopus 로고
    • Sicherheitsaspekte bei der Beschichtung von Titangleitkomponenten.
    • Fink U. Sicherheitsaspekte bei der Beschichtung von Titangleitkomponenten. Orthopäde 1997; 26: 160-165
    • (1997) Orthopäde , vol.26 , pp. 160-165
    • Fink, U.1
  • 14
    • 8644241678 scopus 로고    scopus 로고
    • Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    • Ezzer KA, Hermida JC, Colwell Jr CW, D'Lima DD. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clin Orthop Relat Res 2004; 428: 120-124
    • (2004) Clin Orthop Relat Res , vol.428 , pp. 120-124
    • Ezzer, K.A.1    Hermida, J.C.2    Colwell Jr, C.W.3    D'Lima, D.D.4
  • 15
    • 0035175965 scopus 로고    scopus 로고
    • Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
    • Am
    • Spector BM, Ries MD, Bourne RB et al. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg [Am] 2001; 83 (Suppl 2): 80-86
    • (2001) J Bone Joint Surg , vol.83 , Issue.SUPPL. 2 , pp. 80-86
    • Spector, B.M.1    Ries, M.D.2    Bourne, R.B.3
  • 16
    • 0030248625 scopus 로고    scopus 로고
    • Wear testing of materials and surfaces for total knee replacement
    • Walker PS, Blunn GW, Lilley PA. Wear testing of materials and surfaces for total knee replacement. J Biomed Mater Res 1996; 33: 159-175
    • (1996) J Biomed Mater Res , vol.33 , pp. 159-175
    • Walker, P.S.1    Blunn, G.W.2    Lilley, P.A.3
  • 17
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
    • Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 1989; 248: 9-12
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 9-12
    • FC, E.1
  • 20
    • 0027260455 scopus 로고
    • Nickel sensitization and ear piercing in an unselected Danish population. Glostrup Allergy Study
    • Nielsen NH, Menne T. Nickel sensitization and ear piercing in an unselected Danish population. Glostrup Allergy Study. Contact Dermatitis 1993; 29: 16-21
    • (1993) Contact Dermatitis , vol.29 , pp. 16-21
    • Nielsen, N.H.1    Menne, T.2
  • 21
    • 0022650707 scopus 로고
    • Prevalence of contact allergy by sex, race and age
    • Goh CL. Prevalence of contact allergy by sex, race and age. Contact Dermatitis 1986; 14: 237-240
    • (1986) Contact Dermatitis , vol.14 , pp. 237-240
    • Goh, C.1
  • 22
    • 33745481078 scopus 로고    scopus 로고
    • MRI comparison of periprosthetic structures around zirconium knee prostheses and cobalt chrome prostheses
    • Raphael B, Haims AH, Wu JS, Katz LD, White LM, Lynch K. MRI comparison of periprosthetic structures around zirconium knee prostheses and cobalt chrome prostheses. Am J Roentgenol 2006; 186: 1771-1777
    • (2006) Am J Roentgenol , vol.186 , pp. 1771-1777
    • Raphael, B.1    Haims, A.H.2    Wu, J.S.3    Katz, L.D.4    White, L.M.5    Lynch, K.6
  • 23
    • 10444234298 scopus 로고    scopus 로고
    • The effect of valgus/varus malalignment on load distribution in total knee replacements
    • Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 2005; 38: 349-355
    • (2005) J Biomech , vol.38 , pp. 349-355
    • Werner, F.W.1    Ayers, D.C.2    Maletsky, L.P.3    Rullkoetter, P.J.4
  • 24
    • 0020510446 scopus 로고
    • The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements
    • Am
    • Insall JN, Hood RW, Flawn LB, Sullivan DJ. The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Joint Surg [Am] 1983; 65: 619-628
    • (1983) J Bone Joint Surg , vol.65 , pp. 619-628
    • Insall, J.N.1    Hood, R.W.2    Flawn, L.B.3    Sullivan, D.J.4
  • 25
    • 0017353885 scopus 로고
    • Influence of positioning of prosthesis in total knee replacement
    • Am
    • Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 1977; 59: 77-79
    • (1977) J Bone Joint Surg , vol.59 , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 27
    • 0020629020 scopus 로고
    • Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations
    • Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 1983; 173: 178-183
    • (1983) Clin Orthop Relat Res , vol.173 , pp. 178-183
    • Bargren, J.H.1    Blaha, J.D.2    Freeman, M.A.3
  • 29
    • 0019523354 scopus 로고
    • Functional outcome of GUEPAR Hinge knee arthroplasty evaluated with ARAMIS
    • Schurman DJ. Functional outcome of GUEPAR Hinge knee arthroplasty evaluated with ARAMIS. Clin Orthop Relat Res 1981; 155: 118-132
    • (1981) Clin Orthop Relat Res , vol.155 , pp. 118-132
    • DJ, S.1
  • 30
    • 0023697317 scopus 로고
    • The effect of posterior tibial slope on knee stability after Ortholoc total knee arthroplasty
    • Whiteside LA, Amador DD. The effect of posterior tibial slope on knee stability after Ortholoc total knee arthroplasty. J Arthroplasty 1988; 3: 51-57
    • (1988) J Arthroplasty , vol.3 , pp. 51-57
    • Whiteside, L.A.1    Amador, D.D.2
  • 31
    • 0026757962 scopus 로고
    • Zwei- bis Fünfjahresergebnisse nach Implantation der zementfreien APS-Knietotalendoprothese.
    • Zenz P, Schwägerl W, Jantsch S. Zwei- bis Fünfjahresergebnisse nach Implantation der zementfreien APS-Knietotalendoprothese. Z Orthop Ihre Grenzgeb 1992; 130: 317-322
    • (1992) Z Orthop Ihre Grenzgeb , vol.130 , pp. 317-322
    • Zenz, P.1    Schwägerl, W.2    Jantsch, S.3
  • 32
    • 0242694079 scopus 로고    scopus 로고
    • An oxidized Zirconium ceramic surfaced femoral component for total knee arthroplasty
    • Laskin RS. An oxidized Zirconium ceramic surfaced femoral component for total knee arthroplasty. Clin Orthop Relat Res 2003; 416: 191-196
    • (2003) Clin Orthop Relat Res , vol.416 , pp. 191-196
    • RS, L.1
  • 34
    • 24144463958 scopus 로고    scopus 로고
    • Comparison of subtraction arthrography, radionuclide arthrography and conventional plain radiography to assess loosening of total knee arthroplasty
    • Marx A, Saxler G, Landgraeber S, Loer F, Holland-Letz T, von Knoch M. Comparison of subtraction arthrography, radionuclide arthrography and conventional plain radiography to assess loosening of total knee arthroplasty. Biomed Tech 2005; 50: 143-147
    • (2005) Biomed Tech , vol.50 , pp. 143-147
    • Marx, A.1    Saxler, G.2    Landgraeber, S.3    Loer, F.4    Holland-Letz, T.5    von Knoch, M.6
  • 36
    • 0017350731 scopus 로고
    • Longitudinal study of the radiolucent line at the bone cement interface following total joint-replacement prostheses
    • Am
    • Reckling FW, Asher MA, Dilion W. Longitudinal study of the radiolucent line at the bone cement interface following total joint-replacement prostheses. J Bone Joint Surg [Am] 1977; 59: 355-358
    • (1977) J Bone Joint Surg , vol.59 , pp. 355-358
    • Reckling, F.W.1    Asher, M.A.2    Dilion, W.3
  • 37
    • 0023098711 scopus 로고
    • Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines
    • Ecker ML, Lotke PA, Windsor RE, Cella JP. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 1987; 216: 151-158
    • (1987) Clin Orthop Relat Res , vol.216 , pp. 151-158
    • Ecker, M.L.1    Lotke, P.A.2    Windsor, R.E.3    Cella, J.P.4
  • 39
    • 28444462104 scopus 로고    scopus 로고
    • Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement
    • Br
    • Arora J, Ogden AC. Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement. J Bone joint Surg [Br] 2005; 80: 1502-1506
    • (2005) J Bone joint Surg , vol.80 , pp. 1502-1506
    • Arora, J.1    Ogden, A.C.2
  • 40
    • 1442356127 scopus 로고    scopus 로고
    • The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years
    • Am
    • Lachiewicz PF, Soileau ES. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years. J Bone Joint Surg [Am] 2004; 86: 525-530
    • (2004) J Bone Joint Surg , vol.86 , pp. 525-530
    • Lachiewicz, P.F.1    Soileau, E.S.2
  • 41
    • 33644800146 scopus 로고    scopus 로고
    • Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: Are they clinically significant?
    • Huddleston JI, Wiley JW, Scott RD. Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: are they clinically significant? Clin Orthop Relat Res 2005; 441: 334-339
    • (2005) Clin Orthop Relat Res , vol.441 , pp. 334-339
    • Huddleston, J.I.1    Wiley, J.W.2    Scott, R.D.3
  • 43
    • 0036394796 scopus 로고    scopus 로고
    • Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions
    • Am
    • Ries MD, Salehi A, Widding K, Hunter G. Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions. J Bone Joint Surg [Am] 2002; 84(Suppl 2): 129-135
    • (2002) J Bone Joint Surg , vol.84 , Issue.SUPPL. 2 , pp. 129-135
    • Ries, M.D.1    Salehi, A.2    Widding, K.3    Hunter, G.4
  • 44
    • 0027182551 scopus 로고
    • In-vitro evaluation of the cytocompatibility of wear particles generated by UHMWPE/zirconia friction
    • Ito A, Tateishi T, Niwa S, Tange S. In-vitro evaluation of the cytocompatibility of wear particles generated by UHMWPE/zirconia friction. Clin Mater 1993; 12: 203-209
    • (1993) Clin Mater , vol.12 , pp. 203-209
    • Ito, A.1    Tateishi, T.2    Niwa, S.3    Tange, S.4
  • 45
    • 0032401792 scopus 로고    scopus 로고
    • Polyethylene particles of a "critical size" are necessary for the induction of cytokines by macrophages in vitro
    • Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a "critical size" are necessary for the induction of cytokines by macrophages in vitro. Biomaterials 1998; 19: 2297-2302
    • (1998) Biomaterials , vol.19 , pp. 2297-2302
    • Green, T.R.1    Fisher, J.2    Stone, M.3    Wroblewski, B.M.4    Ingham, E.5
  • 47
    • 84898711621 scopus 로고    scopus 로고
    • Fisher J, Matthews JB, Besong AA, Tipper JL, Stone MH, Ingham E. A novel method for the predictions of functional biological activity of polyethylene wear debris generated in vivo and in vitro. In: Transactions of the sixth World Biomaterials Congress. Society for Biomaterials, Minneapolis, USA, 2000, abstr. 186
    • Fisher J, Matthews JB, Besong AA, Tipper JL, Stone MH, Ingham E. A novel method for the predictions of functional biological activity of polyethylene wear debris generated in vivo and in vitro. In: Transactions of the sixth World Biomaterials Congress. Society for Biomaterials, Minneapolis, USA, 2000, abstr. 186
  • 49
    • 84898710176 scopus 로고    scopus 로고
    • Biocompatibility screening of different calcium phosphate ceramics
    • Bernstein A, Gildenhaar D, Nöbel D, Berger G. Biocompatibility screening of different calcium phosphate ceramics. Biomaterialien 2003; 2: 89
    • (2003) Biomaterialien , vol.2 , pp. 89
    • Bernstein, A.1    Gildenhaar, D.2    Nöbel, D.3    Berger, G.4
  • 50
    • 84898711018 scopus 로고    scopus 로고
    • In vitro Untersuchungen von neuen calciumphosphathaltigen Materialien für Implantatbeschichtungen
    • Bernstein A, Gildenhaar D, Nöbel D, Berger G. In vitro Untersuchungen von neuen calciumphosphathaltigen Materialien für Implantatbeschichtungen. Biomaterialien 2003; 3: 207
    • (2003) Biomaterialien , vol.3 , pp. 207
    • Bernstein, A.1    Gildenhaar, D.2    Nöbel, D.3    Berger, G.4
  • 52
    • 0037247064 scopus 로고    scopus 로고
    • The tissue response to a novel calcium zirconium phosphate ceramics
    • Gross U, Müller-Mai C, Berger G, Ploska U. The tissue response to a novel calcium zirconium phosphate ceramics. Key Eng Mater 2003; 240/242: 629-632
    • (2003) Key Eng Mater , vol.240-242 , pp. 629-632
    • Gross, U.1    Müller-Mai, C.2    Berger, G.3    Ploska, U.4
  • 53
    • 18344411248 scopus 로고    scopus 로고
    • Do calcium zirconium phosphate ceramics inhibit mineralization?
    • Gross U, Müller-Mai C, Berger G, Ploska U. Do calcium zirconium phosphate ceramics inhibit mineralization? Key Eng Mater 2004; 254/256: 635-638
    • (2004) Key Eng Mater , vol.254-256 , pp. 635-638
    • Gross, U.1    Müller-Mai, C.2    Berger, G.3    Ploska, U.4
  • 54
    • 0015373649 scopus 로고
    • Corrosion-related failures in metallic implants: An experimental study
    • Galante J, Rostoker W. Corrosion-related failures in metallic implants: an experimental study. Clin Orthop Relat Res 1972; 86: 237-244
    • (1972) Clin Orthop Relat Res , vol.86 , pp. 237-244
    • Galante, J.1    Rostoker, W.2
  • 55


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.