1
-
-
77955505739
-
The impact of radiation dose exposure during endovascular aneurysm repair on patient safety
-
Jones C, Badger SA, Boyd CS, Soong CV. The impact of radiation dose exposure during endovascular aneurysm repair on patient safety. J Vasc Surg 2010; 52(2): 298-302.
-
(2010)
J Vasc Surg
, vol.52
, Issue.2
, pp. 298-302
-
-
Jones, C.1
Badger, S.A.2
Boyd, C.S.3
Soong, C.V.4
-
2
-
-
33847207145
-
Contrast-induced nephropathy
-
Walsh SR, Tang T, Gaunt ME, Boyle JR. Contrast-induced nephropathy. J Endovasc Therapy 2007; 14(1): 92-100.
-
(2007)
J Endovasc Therapy
, vol.14
, Issue.1
, pp. 92-100
-
-
Walsh, S.R.1
Tang, T.2
Gaunt, M.E.3
Boyle, J.R.4
-
3
-
-
59449097842
-
Overview of the vascular interventional robot
-
Da L, Zhang D, Wang T. Overview of the vascular interventional robot. Int J Med Robot 2008; 4(4): 289-294.
-
(2008)
Int J Med Robot
, vol.4
, Issue.4
, pp. 289-294
-
-
Da, L.1
Zhang, D.2
Wang, T.3
-
4
-
-
73449113302
-
Steerable catheters in minimally invasive vascular surgery
-
Fu Y, Liu H, Huang W, et al. Steerable catheters in minimally invasive vascular surgery. Int J Med Robot 2009; 5(4): 381-391.
-
(2009)
Int J Med Robot
, vol.5
, Issue.4
, pp. 381-391
-
-
Fu, Y.1
Liu, H.2
Huang, W.3
-
6
-
-
34248153080
-
Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery
-
Tercero C, Ikeda S, Uchiyama T, et al. Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery. Int J Med Robot Comput 2007; 3(1): 52-58.
-
(2007)
Int J Med Robot Comput
, vol.3
, Issue.1
, pp. 52-58
-
-
Tercero, C.1
Ikeda, S.2
Uchiyama, T.3
-
7
-
-
61849121933
-
-
A Navigation system of cerebral endovascular surgery integrating multiple space-guiding trackers. 30th Annual International IEEE EMBS Conference; Vancouver, British Columbia, Canada, August 20-24 .
-
Lee JD, Chien TA, Huang CH, et al. A Navigation system of cerebral endovascular surgery integrating multiple space-guiding trackers. 30th Annual International IEEE EMBS Conference; Vancouver, British Columbia, Canada, August 20-24 2008.
-
(2008)
-
-
Lee, J.D.1
Chien, T.A.2
Huang, C.H.3
-
8
-
-
34247325622
-
Preliminary results of nonfluoroscopy-based 3D navigation for neurointerventional procedures
-
Pujol S, Frerichs K, Norbash A, et al. Preliminary results of nonfluoroscopy-based 3D navigation for neurointerventional procedures. J Vasc Interv Radiol 2007; 18(2): 289-298.
-
(2007)
J Vasc Interv Radiol
, vol.18
, Issue.2
, pp. 289-298
-
-
Pujol, S.1
Frerichs, K.2
Norbash, A.3
-
9
-
-
50149120415
-
-
3-D Hall Sensor for use in navigation systems for surgery endovascular interventions. IEEE International Workshop on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications; 6-8 September Dortmund, Germany .
-
Dimitrov K. 3-D Hall Sensor for use in navigation systems for surgery endovascular interventions. IEEE International Workshop on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications; 6-8 September Dortmund, Germany 2007.
-
(2007)
-
-
Dimitrov, K.1
-
10
-
-
33748976523
-
A novel segmentation and navigation tool for endovascular stenting of aortic aneurysms
-
Feuerstein M, Filippatos K, Kutter O, et al. A novel segmentation and navigation tool for endovascular stenting of aortic aneurysms. Int J CARS 2006; 1(1): S280-S282.
-
(2006)
Int J CARS
, vol.1
, Issue.1
-
-
Feuerstein, M.1
Filippatos, K.2
Kutter, O.3
-
11
-
-
44949101744
-
Towards an integrated planning and navigation system for aortic stent-graft placement
-
Kuttera O, Kettnerb S, Brauna E, et al. Towards an integrated planning and navigation system for aortic stent-graft placement. Int J CARS 2007; 2(Suppl 1): S239-S241.
-
(2007)
Int J CARS
, vol.2
, Issue.SUPPL 1
-
-
Kuttera, O.1
Kettnerb, S.2
Brauna, E.3
-
12
-
-
49149098468
-
-
Estimation of 2d/3d rigid transformation of computer-assisted endovascular navigation. International Conference on Information and Communication Technologies: From Theory to Applications, ICCTA 7-11 April; Damascus, Syria, pp 1-6
-
Castro M, Göksu C, Haigron P, et al. Estimation of 2d/3d rigid transformation of computer-assisted endovascular navigation. International Conference on Information and Communication Technologies: From Theory to Applications, ICCTA 7-11 April; Damascus, Syria, pp 1-6, 2008.
-
(2008)
-
-
Castro, M.1
Göksu, C.2
Haigron, P.3
-
13
-
-
16544390987
-
A virtual reality based navigation system for endovascular surgery
-
Pujol S, Pecher M, et al. A virtual reality based navigation system for endovascular surgery. Stud Health Technol Inf 2004; 98: 310-312.
-
(2004)
Stud Health Technol Inf
, vol.98
, pp. 310-312
-
-
Pujol, S.1
Pecher, M.2
-
14
-
-
84873100138
-
-
CARTO® System, Biosense Webster® Available from:
-
CARTO® System, Biosense Webster® Available from: http://www.biosensewebster.com.
-
-
-
-
15
-
-
84873100015
-
-
EP Navigator, Philips Electronics N.V.; Available from:
-
EP Navigator, Philips Electronics N.V.; Available from: http://www.healthcare.philips.com.
-
-
-
-
16
-
-
84873083432
-
-
EnSite System™, St. Jude Medical. Available from:
-
EnSite System™, St. Jude Medical. Available from: http://www.sjmprofessional.com.
-
-
-
-
17
-
-
33646458275
-
Respiratory motion analysis: towards gated augmentation of the liver
-
Olbricha B, Traubb J, Wiesnerb S, et al. Respiratory motion analysis: towards gated augmentation of the liver. International Congress Series 2005; 1281: 248-253.
-
(2005)
International Congress Series
, vol.1281
, pp. 248-253
-
-
Olbricha, B.1
Traubb, J.2
Wiesnerb, S.3
-
18
-
-
33747623309
-
MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning
-
Blackall JM, Ahmad S, Miquel ME, et al. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning. Phys Med Biol 2006; 51(17): 4147-4169.
-
(2006)
Phys Med Biol
, vol.51
, Issue.17
, pp. 4147-4169
-
-
Blackall, J.M.1
Ahmad, S.2
Miquel, M.E.3
-
19
-
-
33748322003
-
A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy
-
McClelland JR, Blackall JM, Tarte S, et al. A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med Phys 2006; 33(9): 3348-3358.
-
(2006)
Med Phys
, vol.33
, Issue.9
, pp. 3348-3358
-
-
McClelland, J.R.1
Blackall, J.M.2
Tarte, S.3
-
20
-
-
84865392956
-
Live 3D guidance in endovascular procedures
-
July
-
Gupta A, Radaelli A. Live 3D guidance in endovascular procedures. Endovasc Today July 2009: 28-40.
-
(2009)
Endovasc Today
, pp. 28-40
-
-
Gupta, A.1
Radaelli, A.2
-
21
-
-
43249127581
-
Comparison of patient dose in two-dimensional carotid arteriography and three-dimensional rotational angiography
-
Tsapaki V, Vano E, Muavrikou I, et al. Comparison of patient dose in two-dimensional carotid arteriography and three-dimensional rotational angiography. Cardiovasc Intervent Radiol 2008; 31(3): 477-482.
-
(2008)
Cardiovasc Intervent Radiol
, vol.31
, Issue.3
, pp. 477-482
-
-
Tsapaki, V.1
Vano, E.2
Muavrikou, I.3
-
22
-
-
32944469943
-
3D cerebral angiography: radiation dose comparison with digital subtraction angiography
-
Schueler BA, Kallmes DF, Cloft HJ. 3D cerebral angiography: radiation dose comparison with digital subtraction angiography. Am J Neuroradiol 2005; 26(8): 1898-1901.
-
(2005)
Am J Neuroradiol
, vol.26
, Issue.8
, pp. 1898-1901
-
-
Schueler, B.A.1
Kallmes, D.F.2
Cloft, H.J.3
-
23
-
-
54949132518
-
EndoCAS navigator platform: a common platform for computer and robotic assistance in minimally invasive surgery
-
Megali G, Ferrari V, Freschi C, et al. EndoCAS navigator platform: a common platform for computer and robotic assistance in minimally invasive surgery. Int J Med Robot Comput 2008; 4(3): 242-2 51.
-
(2008)
Int J Med Robot Comput
, vol.4
, Issue.3
-
-
Megali, G.1
Ferrari, V.2
Freschi, C.3
-
24
-
-
84865354326
-
-
An anatomy driven approach for generation of 3D models from multi-phase CT images. Proceedings of CARS
-
Ferrari V, Cappelli C, Megali G, Pietrabissa A. An anatomy driven approach for generation of 3D models from multi-phase CT images. Proceedings of CARS, 2008; 3.
-
(2008)
, pp. 3
-
-
Ferrari, V.1
Cappelli, C.2
Megali, G.3
Pietrabissa, A.4
-
25
-
-
84873097211
-
-
NDI Aurora® System Available from:
-
NDI Aurora® System Available from: http://www.ndigital.com/medical/aurora.php.
-
-
-
-
26
-
-
84873098829
-
-
OpenSG. Available from:
-
OpenSG. Available from: http://www.opensg.org/.
-
-
-
-
27
-
-
84873095201
-
-
Qt, Nokia. Available from:
-
Qt, Nokia. Available from: http://qt.nokia.com/.
-
-
-
-
28
-
-
84873081491
-
-
Advanced Polymers I. Available from:
-
Advanced Polymers I. Available from: www.advpoly.com.
-
-
-
-
29
-
-
84873082414
-
-
POLYDIAGNOST GmbH. Available from:
-
POLYDIAGNOST GmbH. Available from: http://www.polydiagnost.com
-
-
-
-
30
-
-
61349175847
-
Guidewires, catheters, and sheaths used for thoracic endografting procedures
-
Khoynezhad A, Kruse MJ. Guidewires, catheters, and sheaths used for thoracic endografting procedures. J Cardiac Surg 2009; 24(2): 113-119.
-
(2009)
J Cardiac Surg
, vol.24
, Issue.2
, pp. 113-119
-
-
Khoynezhad, A.1
Kruse, M.J.2
-
31
-
-
84873077015
-
-
Fort Wayne Metals. Available from:
-
Fort Wayne Metals. Available from: http://www.fwmetals.com/.
-
-
-
-
33
-
-
77950979871
-
-
Evaluation of a robotic arm for echocardiography to X-ray image registration during cardiac catheterization procedures. Conference Proceedings, IEEE Engineering in Medicine and Biology Society
-
Ma Y, Penney GP, Bos D, et al. Evaluation of a robotic arm for echocardiography to X-ray image registration during cardiac catheterization procedures. Conference Proceedings, IEEE Engineering in Medicine and Biology Society 2009; 5829-5832.
-
(2009)
, pp. 5829-5832
-
-
Ma, Y.1
Penney, G.P.2
Bos, D.3
-
34
-
-
84873079929
-
-
Dimension Elite, Stratasys Inc.; Available from:
-
Dimension Elite, Stratasys Inc.; Available from: http://www.dimensionprinting.com.
-
-
-
-
35
-
-
84873086629
-
Fabrication strategy to build a patient specific physical simulators for endovascular training
-
Condino S, Carbone M, Ferrari V, et al. (eds.). (eds)Fabrication strategy to build a patient specific physical simulators for endovascular training. Int J CARS 2011; 6(1): S226-S295.
-
(2011)
Int J CARS
, vol.6
, Issue.1
-
-
Condino, S.1
Carbone, M.2
Ferrari, V.3
-
36
-
-
44949231326
-
-
Nafis C, Jensen V, von Jako R, eds). Method for evaluating compatibility of commercial electromagnetic (EM) microsensor tracking systems with surgical and imaging tables. Medical Imaging 2008: Visualization, Image-guided Procedures, and Modeling; Sunday 17 February 2008; San Diego, CA, USA SPIE
-
Nafis C, Jensen V, von Jako R, (eds). Method for evaluating compatibility of commercial electromagnetic (EM) microsensor tracking systems with surgical and imaging tables. Medical Imaging 2008: Visualization, Image-guided Procedures, and Modeling; Sunday 17 February 2008; San Diego, CA, USA SPIE, 2008.
-
(2008)
-
-
-
37
-
-
29644438455
-
The anterior visceral branches of the abdominal aorta and their relationship to the renal arteries
-
Pennington N, Soames RW. The anterior visceral branches of the abdominal aorta and their relationship to the renal arteries. Surg Radiol Anat 2005; 27(5): 395-403.
-
(2005)
Surg Radiol Anat
, vol.27
, Issue.5
, pp. 395-403
-
-
Pennington, N.1
Soames, R.W.2
-
38
-
-
77950877399
-
Real-time integration of 3-D multimodality data in interventional neuroangiography
-
doi: 10.1117/1.3222939.
-
Ruijters D, Babic D, Homan R, et al. Real-time integration of 3-D multimodality data in interventional neuroangiography. J Electron Imaging 2009; 18(3). doi: 10.1117/1.3222939.
-
(2009)
J Electron Imaging
, vol.18
, Issue.3
-
-
Ruijters, D.1
Babic, D.2
Homan, R.3
|