Volumn 36, Issue 4, 2012, Pages 280-287

Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; AUTOPSY; BLOOD SAMPLING; CALIBRATION; CENTRIFUGATION; GRAVIMETRY; LIQUID CHROMATOGRAPHY; MASS SPECTROMETER; MASS SPECTROMETRY; PRECIPITATION; ROBOTICS; SOLID PHASE EXTRACTION; ULTRAVIOLET SPECTROPHOTOMETRY; AUTOANALYSIS; BLOOD; BLOOD ANALYSIS; FORENSIC TOXICOLOGY; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; HUMAN; INSTRUMENTATION; LABORATORY AUTOMATION; METHODOLOGY; REPRODUCIBILITY; STANDARD; VALIDATION STUDY;

EID: 84864540850     PISSN: 01464760     EISSN: 19452403     Source Type: Journal    
DOI: 10.1093/jat/bks014     Document Type: Article
Times cited : (38)

References (24)
  • 1
    • 0036100287 scopus 로고    scopus 로고
    • Matrix effects and selectivity issues in LC-MS-MS
    • Smeraglia, J., Baldrey, S.F., Watson, D. (2002) Matrix effects and selectivity issues in LC-MS-MS. Chromatographia, 55, S95-S99.
    • (2002) Chromatographia , vol.55
    • Smeraglia, J.1    Baldrey, S.F.2    Watson, D.3
  • 2
    • 78650650170 scopus 로고    scopus 로고
    • Recent advances in sample preparation techniques for effective bioanalytical methods
    • Kole, P.L., Venkatesh, G., Sheshala, R. (2011) Recent advances in sample preparation techniques for effective bioanalytical methods. Biomedical Chromatography, 25, 199-217.
    • (2011) Biomedical Chromatography , vol.25 , pp. 199-217
    • Kole, P.L.1    Venkatesh, G.2    Sheshala, R.3
  • 3
    • 0028417208 scopus 로고
    • Hand and shoulder ailments among laboratory technicians using modern plungeroperated pipettes
    • Björkstén, M.G., Almby, B., Jansson, E.S. (1994) Hand and shoulder ailments among laboratory technicians using modern plungeroperated pipettes. Applied Ergonomics, 25, 88-94.
    • (1994) Applied Ergonomics , vol.25 , pp. 88-94
    • Björkstén, M.G.1    Almby, B.2    Jansson, E.S.3
  • 4
    • 2542432017 scopus 로고    scopus 로고
    • High-throughput sample preparation procedures for the quantitation of a new bone integrin anb3 antagonist in human plasma and urine using liquid chromatography-tandem mass spectrometry
    • Zhang, J., Zeng, W., Kitchen, C., Wang, A.Q., Musson, D.G. (2004) High-throughput sample preparation procedures for the quantitation of a new bone integrin anb3 antagonist in human plasma and urine using liquid chromatography-tandem mass spectrometry. Journal of Chromatography B, 806, 167-175.
    • (2004) Journal of Chromatography B , vol.806 , pp. 167-175
    • Zhang, J.1    Zeng, W.2    Kitchen, C.3    Wang, A.Q.4    Musson, D.G.5
  • 5
    • 74549185750 scopus 로고    scopus 로고
    • High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry
    • Fernández, M.M.R., Wille, S.M.R., Samyn, N., Wood, M., López-Rivadulla, M., De Boeck, G. (2009) High-throughput analysis of amphetamines in blood and urine with online solid-phase extraction-liquid chromatography-tandem mass spectrometry. Journal of Analytical Toxicology, 33, 578-587.
    • (2009) Journal of Analytical Toxicology , vol.33 , pp. 578-587
    • Fernández, M.M.R.1    Wille, S.M.R.2    Samyn, N.3    Wood, M.4    López-Rivadulla, M.5    De Boeck, G.6
  • 6
    • 18144429801 scopus 로고    scopus 로고
    • Determination of 16 phthalate metabolites in urine using automated sample preparation and on-line preconcentration/highperformance liquid chromatography/tandem mass spectrometry
    • Kato, K., Silva, M.J., Needham, L.L., Calafat, A.M. (2005) Determination of 16 phthalate metabolites in urine using automated sample preparation and on-line preconcentration/highperformance liquid chromatography/tandem mass spectrometry. Analytical Chemistry, 77, 2985-2991.
    • (2005) Analytical Chemistry , vol.77 , pp. 2985-2991
    • Kato, K.1    Silva, M.J.2    Needham, L.L.3    Calafat, A.M.4
  • 7
    • 0036001224 scopus 로고    scopus 로고
    • High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma
    • Deng, Y., Wu, J., Lloyd, T.L., Chi, C.L., Olah, T.V., Unger, S.E. (2002) High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma. Rapid Communications in Mass Spectrometry, 16, 1116-1123.
    • (2002) Rapid Communications in Mass Spectrometry , vol.16 , pp. 1116-1123
    • Deng, Y.1    Wu, J.2    Lloyd, T.L.3    Chi, C.L.4    Olah, T.V.5    Unger, S.E.6
  • 8
    • 33748579029 scopus 로고    scopus 로고
    • Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry
    • Vogeser, M., Spöhrer, U. (2006) Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry. Clinical Chemistry and Laboratory Medicine, 44, 1126-1130.
    • (2006) Clinical Chemistry and Laboratory Medicine , vol.44 , pp. 1126-1130
    • Vogeser, M.1    Spöhrer, U.2
  • 9
    • 53249140209 scopus 로고    scopus 로고
    • An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood
    • Jagerdeo, E., Montgomerya, M.A., LeBeau, M.A., Sibum, M. (2008) An automated SPE/LC/MS/MS method for the analysis of cocaine and metabolites in whole blood. Journal of Chromatography B, 874, 15-20.
    • (2008) Journal of Chromatography B , vol.874 , pp. 15-20
    • Jagerdeo, E.1    Montgomerya, M.A.2    LeBeau, M.A.3    Sibum, M.4
  • 10
    • 51949101476 scopus 로고    scopus 로고
    • Automation of solid-phase microextraction in high-throughput format and applications to drug analysis
    • Vuckovic, D., Cudjoe, E., Hein, D., Pawliszyn, J. (2008) Automation of solid-phase microextraction in high-throughput format and applications to drug analysis. Analytical Chemistry, 80, 6870-6880.
    • (2008) Analytical Chemistry , vol.80 , pp. 6870-6880
    • Vuckovic, D.1    Cudjoe, E.2    Hein, D.3    Pawliszyn, J.4
  • 11
    • 2342532396 scopus 로고    scopus 로고
    • Automated calibration of TECAN Genesis liquid handling workstation utilizing an online balance and density meter
    • Xie, I. H., Wang, M.H., Carpenter, R., Wu, H.Y. (2004) Automated calibration of TECAN Genesis liquid handling workstation utilizing an online balance and density meter. Assay Drug Development Technology, 2, 71-80.
    • (2004) Assay Drug Development Technology , vol.2 , pp. 71-80
    • Xie, I.H.1    Wang, M.H.2    Carpenter, R.3    Wu, H.Y.4
  • 12
    • 38649139855 scopus 로고    scopus 로고
    • A fully automated plasma protein precipitation sample preparation method for LC-MS/MS bioanalysis
    • Ma, J., Shi, J., Le, H., Cho, R., Huang, J.C., Miao, S., Wong, B.K. (2008) A fully automated plasma protein precipitation sample preparation method for LC-MS/MS bioanalysis. Journal of Chromatography B, 862, 219-226.
    • (2008) Journal of Chromatography B , vol.862 , pp. 219-226
    • Ma, J.1    Shi, J.2    Le, H.3    Cho, R.4    Huang, J.C.5    Miao, S.6    Wong, B.K.7
  • 16
    • 35848956854 scopus 로고    scopus 로고
    • Flexible automated approach for quantitative liquid handling of complex biological samples
    • Palandra, J., Weller, D., Hudson, G., Li, J., Osgood, S., Hudson, E. et al. (2007) Flexible automated approach for quantitative liquid handling of complex biological samples. Analytical Chemistry, 79, 8010-8015.
    • (2007) Analytical Chemistry , vol.79 , pp. 8010-8015
    • Palandra, J.1    Weller, D.2    Hudson, G.3    Li, J.4    Osgood, S.5    Hudson, E.6
  • 17
    • 70349969901 scopus 로고    scopus 로고
    • On-line coupling of solid-phase extraction to liquid chromatography-A review
    • Chen, L., Wang, H., Zeng, Q., Xu, Y., Sun, L., Xu, H. et al. (2009) On-line coupling of solid-phase extraction to liquid chromatography-A review. Journal of Chromatographic Science, 47, 614-623.
    • (2009) Journal of Chromatographic Science , vol.47 , pp. 614-623
    • Chen, L.1    Wang, H.2    Zeng, Q.3    Xu, Y.4    Sun, L.5    Xu, H.6
  • 18
    • 20444481663 scopus 로고    scopus 로고
    • Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma
    • Alnouti, Y., Srinivasan, K., Waddell, D., Bi, H., Kavetskaia, O., Gusev, A.I. (2005) Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma. Journal of Chromatography A, 1080, 99-106.
    • (2005) Journal of Chromatography A , vol.1080 , pp. 99-106
    • Alnouti, Y.1    Srinivasan, K.2    Waddell, D.3    Bi, H.4    Kavetskaia, O.5    Gusev, A.I.6
  • 19
    • 79952932303 scopus 로고    scopus 로고
    • Development of an ultra fast online-solid phase extraction (SPE) liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS) based approach for the determination of drugs in pharmacokinetic studies
    • Schebb, N.H., Inceoglu, B., Rose, T., Wagner, K., Hammock, B.D. (2011) Development of an ultra fast online-solid phase extraction (SPE) liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS) based approach for the determination of drugs in pharmacokinetic studies. Analytical Methods, 3, 420-428.
    • (2011) Analytical Methods , vol.3 , pp. 420-428
    • Schebb, N.H.1    Inceoglu, B.2    Rose, T.3    Wagner, K.4    Hammock, B.D.5
  • 20
    • 56449097003 scopus 로고    scopus 로고
    • Complete automation of solid-phase extraction with subsequent liquid chromatography- tandem mass spectrometry for thequantification of benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, and norbenzoylecgonine in urine-application to a high-throughput urine analysis laboratory
    • Robandt, P.P., Reda, L.J., Klette, K.L. (2008) Complete automation of solid-phase extraction with subsequent liquid chromatography- tandem mass spectrometry for thequantification of benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, and norbenzoylecgonine in urine-application to a high-throughput urine analysis laboratory. Journal of Analytical Toxicology, 32, 577-585.
    • (2008) Journal of Analytical Toxicology , vol.32 , pp. 577-585
    • Robandt, P.P.1    Reda, L.J.2    Klette, K.L.3
  • 21
    • 78650882617 scopus 로고    scopus 로고
    • Progress in automation of LC-MS in laboratory medicine
    • Vogeser, M., Kirchhoff, F. (2011) Progress in automation of LC-MS in laboratory medicine. Clinical Biochemistry, 44, 4-13.
    • (2011) Clinical Biochemistry , vol.44 , pp. 4-13
    • Vogeser, M.1    Kirchhoff, F.2
  • 22
    • 72649097305 scopus 로고    scopus 로고
    • An automated 1536-Well microplate format cytochrome P450 inhibition assay using a Tecan Freedom EVO workstation with integrated innovadynenanodrop II dispenser
    • Litten, B.A., Smith, R., Banfield, E. (2010) An automated 1536-Well microplate format cytochrome P450 inhibition assay using a Tecan Freedom EVO workstation with integrated innovadynenanodrop II dispenser. Journal of the Association for Laboratory Automation, 15, 58-64.
    • (2010) Journal of the Association for Laboratory Automation , vol.15 , pp. 58-64
    • Litten, B.A.1    Smith, R.2    Banfield, E.3
  • 23
    • 69249151211 scopus 로고    scopus 로고
    • A semi-automated solid-phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole blood
    • Jagerdeo, E., Schaff, J.E., Montgomery, M.A., LeBeau, M.A. (2009) A semi-automated solid-phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole blood. Rapid Communications in Mass Spectrometry, 23, 2697-2705.
    • (2009) Rapid Communications in Mass Spectrometry , vol.23 , pp. 2697-2705
    • Jagerdeo, E.1    Schaff, J.E.2    Montgomery, M.A.3    LeBeau, M.A.4
  • 24
    • 79954431386 scopus 로고    scopus 로고
    • On-line SPE LC-MS/MS for the quantification of Δ9-tetrahydrocannabinol (THC) and its two major metabolites in human peripheral blood by liquid chromatography tandem mass spectrometry
    • König, S., Aebi, B., Lanz, S., Gasser, M., Weinmann, W. (2011) On-line SPE LC-MS/MS for the quantification of Δ9-tetrahydrocannabinol (THC) and its two major metabolites in human peripheral blood by liquid chromatography tandem mass spectrometry. Analytical and Bioanalytical Chemistry, 400, 9-16.
    • (2011) Analytical and Bioanalytical Chemistry , vol.400 , pp. 9-16
    • König, S.1    Aebi, B.2    Lanz, S.3    Gasser, M.4    Weinmann, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.