메뉴 건너뛰기




Volumn 14, Issue 4, 2012, Pages 508-516

Short Implants: A Descriptive Study of 273 Implants

Author keywords

Bone resorption; Dental implants; Implant surfaces; Short implants

Indexed keywords

ALVEOLAR BONE LOSS; ARTICLE; CLASSIFICATION; DENTAL SURGERY; FOLLOW UP; HUMAN; MANDIBLE; MAXILLA; METHODOLOGY; RETROSPECTIVE STUDY; STATISTICS; SURFACE PROPERTY; SURVIVAL; TOOTH IMPLANT; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 84864503085     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2010.00301.x     Document Type: Article
Times cited : (29)

References (35)
  • 2
    • 33748291595 scopus 로고    scopus 로고
    • Augmentation procedures for the rehabilitation of deficient edentulous ridges with oral implants
    • Chiapasco M, Zaniboni M, Boisco M. Augmentation procedures for the rehabilitation of deficient edentulous ridges with oral implants. Clin Oral Implants Res 2006; 17 (Suppl 2):136-159.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.SUPPL. 2 , pp. 136-159
    • Chiapasco, M.1    Zaniboni, M.2    Boisco, M.3
  • 3
    • 33646245182 scopus 로고    scopus 로고
    • Effect of flapless surgery on pain experienced in implant placement using an image-guided system
    • Fortin T, Bosson JL, Isidori M, Blanchet E. Effect of flapless surgery on pain experienced in implant placement using an image-guided system. Int J Oral Maxillofac Implants 2006; 21:298-304.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 298-304
    • Fortin, T.1    Bosson, J.L.2    Isidori, M.3    Blanchet, E.4
  • 5
    • 33748323290 scopus 로고    scopus 로고
    • Impact of implant length and diameter on survival rates
    • Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res 2006; 17 (Suppl 2):35-51.
    • (2006) Clin Oral Implants Res , vol.17 , Issue.SUPPL. 2 , pp. 35-51
    • Renouard, F.1    Nisand, D.2
  • 6
    • 26844488582 scopus 로고    scopus 로고
    • Performance of short implants in partial restorations: 3-year follow-up of Osseotite implants
    • Goené R, Bianchesi C, Hüerzeler M, etal. Performance of short implants in partial restorations: 3-year follow-up of Osseotite implants. Implant Dent 2005; 14:274-280.
    • (2005) Implant Dent , vol.14 , pp. 274-280
    • Goené, R.1    Bianchesi, C.2    Hüerzeler, M.3
  • 7
    • 30844452029 scopus 로고    scopus 로고
    • Survival estimates and risk factors for failure with 6×5.7-mm implants
    • Gentile MA, Chuang SK, Dodson TB. Survival estimates and risk factors for failure with 6×5.7-mm implants. Int J Oral Maxillofac Implants 2005; 20:930-937.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 930-937
    • Gentile, M.A.1    Chuang, S.K.2    Dodson, T.B.3
  • 8
    • 1642410940 scopus 로고    scopus 로고
    • Success and failures of 9mm or shorter implants in the replacement of missing maxillary molars when restored with individual crowns: preliminary results 0 to 84 months in function. A retrospective study
    • Fugazzotto PA, Beagle JR, Ganeles J, Jaffin R, Vlassis J, Kumar A. Success and failures of 9mm or shorter implants in the replacement of missing maxillary molars when restored with individual crowns: preliminary results 0 to 84 months in function. A retrospective study. J Periodontol 2004; 75:327-332.
    • (2004) J Periodontol , vol.75 , pp. 327-332
    • Fugazzotto, P.A.1    Beagle, J.R.2    Ganeles, J.3    Jaffin, R.4    Vlassis, J.5    Kumar, A.6
  • 9
    • 38549148514 scopus 로고    scopus 로고
    • Five-year clinical evaluation of short dental implants placed in posterior areas: a retrospective study
    • Anitua E, Orive G, Aguirre JJ, Andía I. Five-year clinical evaluation of short dental implants placed in posterior areas: a retrospective study. J Periodontol 2008; 79:42-48.
    • (2008) J Periodontol , vol.79 , pp. 42-48
    • Anitua, E.1    Orive, G.2    Aguirre, J.J.3    Andía, I.4
  • 10
    • 62349086758 scopus 로고    scopus 로고
    • Outcomes of placing short dental implants in the posterior mandible: a retrospective study of 124 cases
    • Grant BT, Pancko FX, Kraut RA. Outcomes of placing short dental implants in the posterior mandible: a retrospective study of 124 cases. Oral Maxillofac Surg 2009; 67:713-717.
    • (2009) Oral Maxillofac Surg , vol.67 , pp. 713-717
    • Grant, B.T.1    Pancko, F.X.2    Kraut, R.A.3
  • 12
    • 0031614923 scopus 로고    scopus 로고
    • Sinus floor elevation with osteotomes
    • Summers RB. Sinus floor elevation with osteotomes. J Esthet Dent 1998; 10:164-171.
    • (1998) J Esthet Dent , vol.10 , pp. 164-171
    • Summers, R.B.1
  • 13
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: a review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4
  • 14
    • 24744432513 scopus 로고    scopus 로고
    • Short dental implants: a literature review and rationale for use
    • Misch CE. Short dental implants: a literature review and rationale for use. Dent Today 2005; 24:64-66.
    • (2005) Dent Today , vol.24 , pp. 64-66
    • Misch, C.E.1
  • 15
    • 33644803938 scopus 로고    scopus 로고
    • A clinical study of the outcomes and complications associated with maxillary sinus augmentation. A clinical study of the outcomes and complications associated with maxillary sinus augmentation
    • Barone A, Santini S, Sbordone L, Crespi R, Covani U. A clinical study of the outcomes and complications associated with maxillary sinus augmentation. A clinical study of the outcomes and complications associated with maxillary sinus augmentation. Int J Oral Maxillofac Implants 2006; 21:81-85.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 81-85
    • Barone, A.1    Santini, S.2    Sbordone, L.3    Crespi, R.4    Covani, U.5
  • 16
    • 33644804946 scopus 로고    scopus 로고
    • Predictability of simultaneous implant placement in the severely atrophic posterior maxilla: A 9-year longitudinal experience study of 2132 implants placed into 731 human sinus grafts
    • Peleg M, Garg AK, Mazor Z. Predictability of simultaneous implant placement in the severely atrophic posterior maxilla: A 9-year longitudinal experience study of 2132 implants placed into 731 human sinus grafts. Int J Oral Maxillofac Implants 2006; 21:94-102.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 94-102
    • Peleg, M.1    Garg, A.K.2    Mazor, Z.3
  • 19
    • 66749099062 scopus 로고    scopus 로고
    • Maxillary sinus floor elevation using the (transalveolar) osteotome technique with or without grafting material. Part I: Implant survival and patients' perception
    • Pjetursson BE, Rast C, Brägger U, Schmidlin K, Zwalen M, Lang NP. Maxillary sinus floor elevation using the (transalveolar) osteotome technique with or without grafting material. Part I: Implant survival and patients' perception. Clin Oral Implants Res 2009; 20:667-676.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 667-676
    • Pjetursson, B.E.1    Rast, C.2    Brägger, U.3    Schmidlin, K.4    Zwalen, M.5    Lang, N.P.6
  • 20
    • 69849114184 scopus 로고    scopus 로고
    • Implant success in sinus-lifted maxillae and native bone: a 3-year clinical a computerized tomographic follow-up
    • Sbordone L, Toti P, Menchini-Fabris G, Sbordone C, Guidetti F. Implant success in sinus-lifted maxillae and native bone: a 3-year clinical a computerized tomographic follow-up. Int J Oral Maxillofac Implants 2009; 24:316-324.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 316-324
    • Sbordone, L.1    Toti, P.2    Menchini-Fabris, G.3    Sbordone, C.4    Guidetti, F.5
  • 21
    • 33646257306 scopus 로고    scopus 로고
    • Influence of prosthetic parameters on the survival and complication rates of short implants
    • Tawil G, Aboujaoude N, Younan R. Influence of prosthetic parameters on the survival and complication rates of short implants. Int J Oral Maxillofac Implants 2006; 21:275-282.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 275-282
    • Tawil, G.1    Aboujaoude, N.2    Younan, R.3
  • 22
    • 20744446270 scopus 로고    scopus 로고
    • Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study
    • Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res 2005; 7 (Suppl 1):S104-S110.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Renouard, F.1    Nisand, D.2
  • 23
    • 14844362992 scopus 로고    scopus 로고
    • An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients
    • Rokni S, Todescan R, Watson P, Pharoah M, Adegbembo AO, Deporter D. An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients. Int J Oral Maxillofac Implants 2005; 20:69-76.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 69-76
    • Rokni, S.1    Todescan, R.2    Watson, P.3    Pharoah, M.4    Adegbembo, A.O.5    Deporter, D.6
  • 24
    • 3543026382 scopus 로고    scopus 로고
    • A targeted review of study outcomes with short (< or = 7mm) endosseous dental implants placed in partially edentulous patients
    • Hagi D, Deporter DA, Pilliar RM, Arenovich T. A targeted review of study outcomes with short (< or = 7mm) endosseous dental implants placed in partially edentulous patients. J Periodontol 2004; 75:798-804.
    • (2004) J Periodontol , vol.75 , pp. 798-804
    • Hagi, D.1    Deporter, D.A.2    Pilliar, R.M.3    Arenovich, T.4
  • 25
    • 0035293260 scopus 로고    scopus 로고
    • A prospective multicenter clinical study of the Osseotite implant: four-year interim report
    • Testori T, Wiseman L, Woolfe S, Porter SS. A prospective multicenter clinical study of the Osseotite implant: four-year interim report. Int J Oral Maxillofac Implants 2001; 16:193-200.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 193-200
    • Testori, T.1    Wiseman, L.2    Woolfe, S.3    Porter, S.S.4
  • 26
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: early data from a clinical trial
    • Deporter D, Pilliar RM, Todescan R, Watson P, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: early data from a clinical trial. Int J Oral Maxillofac Implants 2001; 16:653-658.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-658
    • Deporter, D.1    Pilliar, R.M.2    Todescan, R.3    Watson, P.4    Pharoah, M.5
  • 27
    • 26944455656 scopus 로고    scopus 로고
    • Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis
    • Petrie CS, Williams JL. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. Clin Oral Implants Res 2005; 16:486-494.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 486-494
    • Petrie, C.S.1    Williams, J.L.2
  • 28
    • 0032199450 scopus 로고    scopus 로고
    • Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits
    • Piattelli A, Manzon L, Scarano A, Paolantonio M, Piattelli M. Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits. Int J Oral Maxillofac Implants 1998; 13:805-810.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 805-810
    • Piattelli, A.1    Manzon, L.2    Scarano, A.3    Paolantonio, M.4    Piattelli, M.5
  • 31
    • 0034186403 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants
    • Gatti C, Haefliger W, Chiapasco M. Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants. Int J Oral Maxillofac Implants 2000; 15:383-388.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 383-388
    • Gatti, C.1    Haefliger, W.2    Chiapasco, M.3
  • 32
    • 0034574960 scopus 로고    scopus 로고
    • Early functional loading of Branemark dental implants: 5-year clinical follow-up study
    • Ericsson I, Randow K, Nilner K, Petersson A. Early functional loading of Branemark dental implants: 5-year clinical follow-up study. Clin Implant Dent Relat Res 2000; 2:70-77.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 70-77
    • Ericsson, I.1    Randow, K.2    Nilner, K.3    Petersson, A.4
  • 33
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997; 12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 34
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder T. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997; 8:48-57.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.5
  • 35
    • 0034326765 scopus 로고    scopus 로고
    • Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report
    • Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000; 15:824-830.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 824-830
    • Horiuchi, K.1    Uchida, H.2    Yamamoto, K.3    Sugimura, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.