메뉴 건너뛰기




Volumn 21, Issue 2, 2006, Pages 275-282

Influence of prosthetic parameters on the survival and complication rates of short implants

Author keywords

Crown implant ratios; Implant complication rates; Prosthetic parameters; Short implants

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; BRUXISM; DENTAL CARE; DENTAL SURGERY; DENTURE; FEMALE; HUMAN; MALE; MIDDLE AGED; OSTEOLYSIS; RISK FACTOR; STATISTICAL MODEL; TOOTH CROWN; TOOTH IMPLANTATION; TOOTH OCCLUSION; TOOTH PROSTHESIS;

EID: 33646257306     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (163)

References (33)
  • 1
    • 0027735092 scopus 로고
    • The successful application of osseointegrated implants to the posterior jaw: A long-term retrospective study
    • Nevins M, Langer B. The successful application of osseointegrated implants to the posterior jaw: A long-term retrospective study. Int J Oral Maxillofac Implants 1993;8:428-432.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 428-432
    • Nevins, M.1    Langer, B.2
  • 2
    • 0030090692 scopus 로고    scopus 로고
    • Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period
    • Lazzra R, Siddiqui AA, Binon P, et al. Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period. Clin Oral Implants Res 1996;7:73-83.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 73-83
    • Lazzra, R.1    Siddiqui, A.A.2    Binon, P.3
  • 3
    • 0033092147 scopus 로고    scopus 로고
    • A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants
    • Grunder U, Goene R, Hatano N, et al. A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants. Int J Oral Maxillofac Implants 1999;14:210-221.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 210-221
    • Grunder, U.1    Goene, R.2    Hatano, N.3
  • 4
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brånemark implant in partially edentulous jaws: A ten-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in partially edentulous jaws: A ten-year prospective multicenter study. Int J Oral Maxillofac Implants 1999;14: 639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 5
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single tooth replacement: A prospective 5-year multi-center study
    • Henry PJ, Laney WR, Jemt T, et al. Osseointegrated implants for single tooth replacement: A prospective 5-year multi-center study. Int J Oral Maxillofac Implants 1996;11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.J.1    Laney, W.R.2    Jemt, T.3
  • 6
    • 0347418233 scopus 로고    scopus 로고
    • Clinical evaluation of short, machined-surface implants followed for 12 to 92 months
    • Tawil G, Younan R. Clinical evaluation of short, machined-surface implants followed for 12 to 92 months. Int J Oral Maxillofacial Implants 2003;18:894-901.
    • (2003) Int J Oral Maxillofacial Implants , vol.18 , pp. 894-901
    • Tawil, G.1    Younan, R.2
  • 7
    • 0032018775 scopus 로고    scopus 로고
    • Use of the Endopore dental implant to restore single teeth in the maxilla; Protocol and early results
    • Deporter DA, Todescan R, Watson PA, et al. Use of the Endopore dental implant to restore single teeth in the maxilla; Protocol and early results. Int J Oral Maxillofac Implants 1998;13: 263-272.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 263-272
    • Deporter, D.A.1    Todescan, R.2    Watson, P.A.3
  • 8
  • 9
    • 0029438579 scopus 로고
    • Ten year survival rate of fixed prostheses on four or six implants ad modum Brånemark in full edentulism
    • Brånemark P-I, Svensson B, van Steenberghe D. Ten year survival rate of fixed prostheses on four or six implants ad modum Brånemark in full edentulism. Clin Oral Implants Res 1995;6:227-231.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 227-231
    • Brånemark, P.-I.1    Svensson, B.2    Van Steenberghe, D.3
  • 10
    • 0029681009 scopus 로고    scopus 로고
    • A prospective clinical study in humans of an endosseous dental implant partially covered with a powder-sintered porous coating: 3- to 4-year results
    • Deporter DA, Watson PA, Pillar RM, et al. A prospective clinical study in humans of an endosseous dental implant partially covered with a powder-sintered porous coating: 3- to 4-year results. Int J Oral Maxillofac Implants 1996;11:87-95.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 87-95
    • Deporter, D.A.1    Watson, P.A.2    Pillar, R.M.3
  • 12
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial
    • Deporter D, Pilliar RM, Jodescan R, Watson P, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial. Int J Oral Maxillofac Implants 2001;16:653-665.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-665
    • Deporter, D.1    Pilliar, R.M.2    Jodescan, R.3    Watson, P.4    Pharoah, M.5
  • 13
    • 0032088918 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants
    • Esposito M, Hirsh J-M, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. Euro Oral Sci 1998;106:721-764.
    • (1998) Euro Oral Sci , vol.106 , pp. 721-764
    • Esposito, M.1    Hirsh, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 14
    • 0031134265 scopus 로고    scopus 로고
    • Load factor control for implants in the posterior partially edentulous segment
    • Rangert B, Eng M, Sullivan R, Jemt T. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants 1997;12:360-370.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 360-370
    • Rangert, B.1    Eng, M.2    Sullivan, R.3    Jemt, T.4
  • 16
    • 0038488552 scopus 로고    scopus 로고
    • Complications after treatment with implant supported prostheses: A retrospective study
    • Gothberg C, Bergendal T, Magnusson T. Complications after treatment with implant supported prostheses: A retrospective study. Int J Prosthodont 2003;16:201-207.
    • (2003) Int J Prosthodont , vol.16 , pp. 201-207
    • Gothberg, C.1    Bergendal, T.2    Magnusson, T.3
  • 18
    • 0038316551 scopus 로고
    • Aspects of biomechanical considerations
    • Brånemark P-I, Zarb GA, Albrektsson T (eds). Chicago: Quintessence
    • Skalak R. Aspects of biomechanical considerations. In: Brånemark P-I, Zarb GA, Albrektsson T (eds). Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago: Quintessence, 1985:117-128.
    • (1985) Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , pp. 117-128
    • Skalak, R.1
  • 19
    • 0031612903 scopus 로고    scopus 로고
    • Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    • Stegaroiu R, Sato T, Kusakari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis. Int J Oral Maxillofac Implants 1998;13:82-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 82-90
    • Stegaroiu, R.1    Sato, T.2    Kusakari, H.3    Miyakawa, O.4
  • 20
    • 85016033318 scopus 로고
    • Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SH, Brunski JB, Cochran GVB. Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.H.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 21
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone dental implant interface
    • Brunski JB. Biomechanical factors affecting the bone dental implant interface. Clin Mater 1992;10:153-201.
    • (1992) Clin Mater , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 22
    • 0027023585 scopus 로고
    • Force transfer in implant dentistry: Basic concepts and principles
    • Bidez MW, Misch CE. Force transfer in implant dentistry: Basic concepts and principles. J Oral Implantol 1992;18:264-274.
    • (1992) J Oral Implantol , vol.18 , pp. 264-274
    • Bidez, M.W.1    Misch, C.E.2
  • 23
    • 2942694212 scopus 로고    scopus 로고
    • A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants
    • Nedir R, Bischof M, Briaux JM, Beyer S, Bernard JP. A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants. Clin Oral Implants Res 2004;15:150-157.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 150-157
    • Nedir, R.1    Bischof, M.2    Briaux, J.M.3    Beyer, S.4    Bernard, J.P.5
  • 24
    • 33646250483 scopus 로고
    • Periodontal prostheses
    • Goldman HM, Cohen DW. St Louis: Mosby
    • Amsterdam M, Abrams L. Periodontal prostheses. In: Goldman HM, Cohen DW. Periodontal Therapy. St Louis: Mosby, 1973:977-1013.
    • (1973) Periodontal Therapy , pp. 977-1013
    • Amsterdam, M.1    Abrams, L.2
  • 27
    • 0042382997 scopus 로고    scopus 로고
    • Implant-supported fixed cantilever prostheses in partially edentulous arches. A seven year prospective study
    • Romeo E, Lops D, Margutti E, Ghisolfi M, Chiapasco M, Vogel G. Implant-supported fixed cantilever prostheses in partially edentulous arches. A seven year prospective study. Clin Oral Implants Res 2003;14:303-311.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 303-311
    • Romeo, E.1    Lops, D.2    Margutti, E.3    Ghisolfi, M.4    Chiapasco, M.5    Vogel, G.6
  • 28
    • 0028022458 scopus 로고
    • Survival of fixed implant-supported prostheses related to cantilever length
    • Shackleton J, Carr L, Slabbert J, Becker PJ. Survival of fixed implant-supported prostheses related to cantilever length. J Prosthet Dent 1994;71:23-26.
    • (1994) J Prosthet Dent , vol.71 , pp. 23-26
    • Shackleton, J.1    Carr, L.2    Slabbert, J.3    Becker, P.J.4
  • 29
    • 0034221730 scopus 로고    scopus 로고
    • The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restoration
    • Ciftci Y, Canay S. The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restoration. Int J Oral Maxillofac Implants 2000;15:571-582.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 571-582
    • Ciftci, Y.1    Canay, S.2
  • 30
    • 0346260761 scopus 로고
    • Comparative study of various occlusal materials for implant prosthodontics
    • Ismail Y, Kukunas R, Pkpho D, Ibiary W. Comparative study of various occlusal materials for implant prosthodontics [abstract]. J Dent Res 1989;68:962.
    • (1989) J Dent Res , vol.68 , pp. 962
    • Ismail, Y.1    Kukunas, R.2    Pkpho, D.3    Ibiary, W.4
  • 31
    • 0032197414 scopus 로고    scopus 로고
    • Influence of prosthesis material on stress distribution in bone and implants: A 3-dimentional finite element analysis
    • Stegaroiu R, Nishiyama S, Kusakari H, Miyakawa O. Influence of prosthesis material on stress distribution in bone and implants: A 3-dimentional finite element analysis. Int J Oral Maxillofac Implants 1998;13:781-790.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 781-790
    • Stegaroiu, R.1    Nishiyama, S.2    Kusakari, H.3    Miyakawa, O.4
  • 32
    • 0026810954 scopus 로고
    • A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism
    • Naert I, Quirynen M, van Steenberghe D, Darius PA. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-245.
    • (1992) J Prosthet Dent , vol.67 , pp. 236-245
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.A.4
  • 33
    • 0026920402 scopus 로고
    • The influence of occlusal surface material on peak masticatory forces using osseointegrated implant supported prostheses
    • Hobkirk JA, Psarros J. The influence of occlusal surface material on peak masticatory forces using osseointegrated implant supported prostheses. Int J Oral Maxillofac Implants 1992;7: 345-352.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 345-352
    • Hobkirk, J.A.1    Psarros, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.