메뉴 건너뛰기




Volumn 15, Issue 3, 2000, Pages 383-388

Implant-Retained Mandibular Overdentures with Immediate Loading: A Prospective Study of ITI Implants

Author keywords

Complete overdentures; Dental implants; Edentulous jaw; Immediate implant loading; Mandibular prosthesis; Osseointegration; Prospective study

Indexed keywords

BIOMATERIAL;

EID: 0034186403     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (181)

References (34)
  • 1
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Brånemark P-I. Osseointegration and its experimental background. J Prosthet Dent 1993;50:399-410.
    • (1993) J Prosthet Dent , vol.50 , pp. 399-410
    • Brånemark, P.-I.1
  • 2
    • 0022612152 scopus 로고
    • Titanium plasma spray screw implant system for reconstruction of the edentulous mandible
    • Babbush CA. Titanium plasma spray screw implant system for reconstruction of the edentulous mandible. Dent Clin North Am 1986;30:117-130.
    • (1986) Dent Clin North Am , vol.30 , pp. 117-130
    • Babbush, C.A.1
  • 3
    • 0026298489 scopus 로고
    • Tissue integration of one-stage ITI implants: 3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants
    • Buser D, Weber HP, Brägger U, Balsiger C. Tissue integration of one-stage ITI implants: 3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants. Int J Oral Maxillofac Surg 1991;6:405-412.
    • (1991) Int J Oral Maxillofac Surg , vol.6 , pp. 405-412
    • Buser, D.1    Weber, H.P.2    Brägger, U.3    Balsiger, C.4
  • 4
    • 0027566663 scopus 로고
    • Overdentures: An alternative implant methodology for edentulous patients
    • Zarb GA. Overdentures: An alternative implant methodology for edentulous patients. Int J Prosthodont 1993;6(2):203-208.
    • (1993) Int J Prosthodont , vol.6 , Issue.2 , pp. 203-208
    • Zarb, G.A.1
  • 5
    • 0029317640 scopus 로고
    • Osseointegration of Brånemark fixtures using a single-step operating technique: A preliminary prospective one-year study in the edentulous mandible
    • Bernard JP, Belser UC, Martinet JP, Borgis SA. Osseointegration of Brånemark fixtures using a single-step operating technique: A preliminary prospective one-year study in the edentulous mandible. Clin Oral Implants Res 1995;6:122-129.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 122-129
    • Bernard, J.P.1    Belser, U.C.2    Martinet, J.P.3    Borgis, S.A.4
  • 6
    • 0018589158 scopus 로고
    • Stegprothetische Versorgung des zahnlosen Unterkeifers mit Hilfe von plasmabeschichteten Titanschraubenimplantaten
    • Ledermann PD. Stegprothetische Versorgung des zahnlosen Unterkeifers mit Hilfe von plasmabeschichteten Titanschraubenimplantaten. Dtsch Zahnärztl Z 1979;34:907-911.
    • (1979) Dtsch Zahnärztl Z , vol.34 , pp. 907-911
    • Ledermann, P.D.1
  • 7
    • 0041458803 scopus 로고
    • Sechsjachrige Klinische Erfahrung mit dem titanplasmabeschichteten ITI-Schraubenimplantat in der Regio Interforaminalis des Unterkiefers
    • Ledermann PD. Sechsjachrige Klinische Erfahrung mit dem titanplasmabeschichteten ITI-Schraubenimplantat in der Regio Interforaminalis des Unterkiefers. Schweiz Monatsschr Zahnmed 1983;93:1080-1089.
    • (1983) Schweiz Monatsschr Zahnmed , vol.93 , pp. 1080-1089
    • Ledermann, P.D.1
  • 8
    • 0042961798 scopus 로고
    • Hybridprothetische Suprastrukturen mit Konuskronen oder Hulsen-stift-systemen auf Ha-Ti implantaten
    • Graber G, Besimo C. Hybridprothetische Suprastrukturen mit Konuskronen oder Hulsen-stift-systemen auf Ha-Ti implantaten. Fortsch Zahnärztl Implantol 1991;7:125-130.
    • (1991) Fortsch Zahnärztl Implantol , vol.7 , pp. 125-130
    • Graber, G.1    Besimo, C.2
  • 9
    • 0346405936 scopus 로고    scopus 로고
    • Der Sofort-implantat-steg im zahnlosen unterkiefer
    • Ledermann PD. Der Sofort-implantat-steg im zahnlosen unterkiefer. Swiss Dent 1996;17:5-18.
    • (1996) Swiss Dent , vol.17 , pp. 5-18
    • Ledermann, P.D.1
  • 10
    • 0029263609 scopus 로고
    • A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures
    • Spiekermann H, Jansen VK, Richter EJ. A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. Int J Oral Maxillofac Implants 1995;10:231-243.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 231-243
    • Spiekermann, H.1    Jansen, V.K.2    Richter, E.J.3
  • 11
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. a retrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997;8:48-57.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 12
    • 0347666773 scopus 로고    scopus 로고
    • Overdenture mandibolari a esclusivo appoggio implantare e carico immediato. Studio prospettico su impianti Ha-Ti
    • Gatti C, Sild E, Rossi E, Crescentini M, Chiapasco M. Overdenture mandibolari a esclusivo appoggio implantare e carico immediato. Studio prospettico su impianti Ha-Ti. Implantologia Orale 1998;1:9-14.
    • (1998) Implantologia Orale , vol.1 , pp. 9-14
    • Gatti, C.1    Sild, E.2    Rossi, E.3    Crescentini, M.4    Chiapasco, M.5
  • 13
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb GA, Worthington P, Eriksson RA. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.A.2    Worthington, P.3    Eriksson, R.A.4
  • 18
    • 0024760224 scopus 로고
    • Criteria for success for osseointegrated endosseous implants
    • Smith DE, Zarb GA. Criteria for success for osseointegrated endosseous implants. J Prosthet Dent 1989;62:567-572.
    • (1989) J Prosthet Dent , vol.62 , pp. 567-572
    • Smith, D.E.1    Zarb, G.A.2
  • 19
  • 22
    • 0024839720 scopus 로고
    • The longitudinal clinical efficacy of Core-Vent dental implants: A 5-year report
    • Patrick D, Zosky J, Lubar R, Buch A. The longitudinal clinical efficacy of Core-Vent dental implants: A 5-year report. J Oral Implantol 1989;15:95-103.
    • (1989) J Oral Implantol , vol.15 , pp. 95-103
    • Patrick, D.1    Zosky, J.2    Lubar, R.3    Buch, A.4
  • 25
    • 0028434828 scopus 로고
    • A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy: A preliminary report
    • Naert I, Quirynen M, Hooghe M, van Steenberghe D. A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy: A preliminary report. J Prosthet Dent 1994;71:486-492.
    • (1994) J Prosthet Dent , vol.71 , pp. 486-492
    • Naert, I.1    Quirynen, M.2    Hooghe, M.3    Van Steenberghe, D.4
  • 26
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 27
    • 0026902692 scopus 로고
    • Bar-retained overdentures for implants: Technical aspects
    • Jennings KJ, Lilly P. Bar-retained overdentures for implants: Technical aspects. J Prosthet Dent 1992;68(2):380-384.
    • (1992) J Prosthet Dent , vol.68 , Issue.2 , pp. 380-384
    • Jennings, K.J.1    Lilly, P.2
  • 28
    • 0028433413 scopus 로고
    • A three-dimensional finite element study on two versus four implants in an edentulous mandible
    • Meijer HJA, Starmans FJM, Steen WHA, Bosman F. A three-dimensional finite element study on two versus four implants in an edentulous mandible. Int J Prosthodont 1994; 7:271-279.
    • (1994) Int J Prosthodont , vol.7 , pp. 271-279
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Steen, W.H.A.3    Bosman, F.4
  • 29
    • 0345774787 scopus 로고
    • Produzione di una barra per impianti a vite con rivestimento al plasma in titanio secondo Ledermann, nella regione interforaminale (I)
    • Frischherz R. Produzione di una barra per impianti a vite con rivestimento al plasma in titanio secondo Ledermann, nella regione interforaminale (I). Quintessence Odontoiatrica 1985;1:11-18.
    • (1985) Quintessence Odontoiatrica , vol.1 , pp. 11-18
    • Frischherz, R.1
  • 30
    • 0347035954 scopus 로고
    • Produzione di una barra per impianti a vite con rivestimento al plasma in titanio secondo Ledermann, nella regione interforaminale (II)
    • Frischherz R. Produzione di una barra per impianti a vite con rivestimento al plasma in titanio secondo Ledermann, nella regione interforaminale (II). Quintessence Odontoiatrica 1985;2:95-101.
    • (1985) Quintessence Odontoiatrica , vol.2 , pp. 95-101
    • Frischherz, R.1
  • 32
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 33
    • 0026037234 scopus 로고
    • The longitudinal effectiveness of osseointegrated dental implants. The Toronto study. Bone level changes
    • Chaytor DV, Zarb GA, Schmitt A, Lewis DW. The longitudinal effectiveness of osseointegrated dental implants. The Toronto study. Bone level changes. Int J Periodontics Restorative Dent 1991;11:112-125.
    • (1991) Int J Periodontics Restorative Dent , vol.11 , pp. 112-125
    • Chaytor, D.V.1    Zarb, G.A.2    Schmitt, A.3    Lewis, D.W.4
  • 34
    • 0029175464 scopus 로고
    • Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Brånemark implants
    • Hutton JE, Heath MR, Chai JY, Harnett J, Jemt T, Johns RB, et al. Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Brånemark implants. Int J Oral Maxillofac Implants 1995;10:33-42.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 33-42
    • Hutton, J.E.1    Heath, M.R.2    Chai, J.Y.3    Harnett, J.4    Jemt, T.5    Johns, R.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.