메뉴 건너뛰기




Volumn 25, Issue 6, 2012, Pages 962-968

Establishing goals of volume management in critically ill patients with renal failure

Author keywords

Delta blood volume; Fluid management; Fluid overload; Stroke volume; Stroke volume variability

Indexed keywords

ADULT; ARTERIAL PRESSURE; ARTICLE; BLOOD VOLUME; CLINICAL ARTICLE; CRITICALLY ILL PATIENT; FEMALE; HEART INDEX; HEART LEFT VENTRICLE FILLING; HEART OUTPUT; HEART PRELOAD; HEART STROKE VOLUME; HUMAN; INTENSIVE CARE UNIT; KIDNEY FAILURE; MALE; PATIENT CARE; RENAL REPLACEMENT THERAPY;

EID: 84863839808     PISSN: 11218428     EISSN: 17246059     Source Type: Journal    
DOI: 10.5301/jn.5000076     Document Type: Article
Times cited : (9)

References (31)
  • 1
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Early Goal-Directed Therapy Collaborative Group
    • Rivers E, Nguyen B, Havstad S, et al; Early Goal-Directed Therapy Collaborative Group. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368-1377.
    • (2001) N Engl J Med , vol.345 , Issue.19 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3
  • 2
    • 0036792321 scopus 로고    scopus 로고
    • Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery
    • Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97(4):820-826.
    • (2002) Anesthesiology , vol.97 , Issue.4 , pp. 820-826
    • Gan, T.J.1    Soppitt, A.2    Maroof, M.3
  • 3
    • 33745081608 scopus 로고    scopus 로고
    • National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. Comparison of two fluid-management strategies in acute lung injury
    • Wiedemann HP, Wheeler AP, Bernard GR, et al; National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564-2575.
    • (2006) N Engl J Med , vol.354 , Issue.24 , pp. 2564-2575
    • Wiedemann, H.P.1    Wheeler, A.P.2    Bernard, G.R.3
  • 4
    • 45749149531 scopus 로고    scopus 로고
    • A positive fluid balance is associated with a worse outcome in patients with acute renal failure
    • Sepsis Occurrence in Acutely Ill Patients (SOAP) Investigators
    • Payen D, de Pont AC, Sakr Y, Spies C, Reinhart K, Vincent JL; Sepsis Occurrence in Acutely Ill Patients (SOAP) Investigators. A positive fluid balance is associated with a worse outcome in patients with acute renal failure. Crit Care. 2008;12(3):R74.
    • (2008) Crit Care , vol.12 , Issue.3
    • Payen, D.1    de Pont, A.C.2    Sakr, Y.3    Spies, C.4    Reinhart, K.5    Vincent, J.L.6
  • 5
    • 0642338453 scopus 로고    scopus 로고
    • Effects of intravenous fluid restriction on postoperative complications: Comparison of two perioperative fluid regimens: A randomized assessor-blinded multicenter trial
    • Danish Study Group on Perioperative Fluid Therapy
    • Brandstrup B, Tønnesen H, Beier-Holgersen R, et al; Danish Study Group on Perioperative Fluid Therapy. Effects of intravenous fluid restriction on postoperative complications: comparison of two perioperative fluid regimens: a randomized assessor-blinded multicenter trial. Ann Surg. 2003;238(5):641-648.
    • (2003) Ann Surg , vol.238 , Issue.5 , pp. 641-648
    • Brandstrup, B.1    Tønnesen, H.2    Beier-Holgersen, R.3
  • 6
    • 8844232541 scopus 로고    scopus 로고
    • Effect of fluid overload and dose of replacement fluid on survival in hemofiltration
    • Gillespie RS, Seidel K, Symons JM. Effect of fluid overload and dose of replacement fluid on survival in hemofiltration. Pediatr Nephrol. 2004;19(12):1394-1399.
    • (2004) Pediatr Nephrol , vol.19 , Issue.12 , pp. 1394-1399
    • Gillespie, R.S.1    Seidel, K.2    Symons, J.M.3
  • 7
    • 68249103552 scopus 로고    scopus 로고
    • Fluid accumulation, survival and recovery of kidney function in critically ill patients with acute kidney injury
    • Program to Improve Care in Acute Renal Disease (PICARD) Study Group
    • Bouchard J, Soroko SB, Chertow GM, et al; Program to Improve Care in Acute Renal Disease (PICARD) Study Group. Fluid accumulation, survival and recovery of kidney function in critically ill patients with acute kidney injury. Kidney Int. 2009;76(4):422-427.
    • (2009) Kidney Int , vol.76 , Issue.4 , pp. 422-427
    • Bouchard, J.1    Soroko, S.B.2    Chertow, G.M.3
  • 8
    • 62349135283 scopus 로고    scopus 로고
    • Fluid balance as a biomarker: Impact of fluid overload on outcome in critically ill patients with acute kidney injury
    • Bagshaw SM, Brophy PD, Cruz D, Ronco C. Fluid balance as a biomarker: impact of fluid overload on outcome in critically ill patients with acute kidney injury. Crit Care. 2008;12(4):169.
    • (2008) Crit Care , vol.12 , Issue.4 , pp. 169
    • Bagshaw, S.M.1    Brophy, P.D.2    Cruz, D.3    Ronco, C.4
  • 9
    • 16844373169 scopus 로고    scopus 로고
    • Relationship between fluid status and its management on acute renal failure (ARF) in intensive care unit (ICU) patients with sepsis: A prospective analysis
    • Van Biesen W, Yegenaga I, Vanholder R, et al. Relationship between fluid status and its management on acute renal failure (ARF) in intensive care unit (ICU) patients with sepsis: a prospective analysis. J Nephrol. 2005;18(1):54-60
    • (2005) J Nephrol , vol.18 , Issue.1 , pp. 54-60
    • van Biesen, W.1    Yegenaga, I.2    Vanholder, R.3
  • 10
    • 65249191415 scopus 로고    scopus 로고
    • Volume management in continuous renal replacement therapy
    • Bouchard J, Mehta RL. Volume management in continuous renal replacement therapy. Semin Dial. 2009;22(2):146-150.
    • (2009) Semin Dial , vol.22 , Issue.2 , pp. 146-150
    • Bouchard, J.1    Mehta, R.L.2
  • 12
    • 0032748326 scopus 로고    scopus 로고
    • Online monitoring in continuous renal replacement therapies
    • Ronco C, Brendolan A, Bellomo R. Online monitoring in continuous renal replacement therapies. Kidney Int Suppl. 1999;(72):S8-14.
    • (1999) Kidney Int , Issue.72
    • Ronco, C.1    Brendolan, A.2    Bellomo, R.3
  • 14
    • 0035169654 scopus 로고    scopus 로고
    • Should relative blood volume changes be routinely measured during the dialysis session?
    • Basile C. Should relative blood volume changes be routinely measured during the dialysis session? Nephrol Dial Transplant. 2001;16(1):10-12.
    • (2001) Nephrol Dial Transplant , vol.16 , Issue.1 , pp. 10-12
    • Basile, C.1
  • 15
    • 74549152648 scopus 로고    scopus 로고
    • A simple physiologic algorithm for managing hemodynamics using stroke volume and stroke volume variation: Physiologic optimization program
    • McGee WT. A simple physiologic algorithm for managing hemodynamics using stroke volume and stroke volume variation: physiologic optimization program. J Intensive Care Med. 2009;24(6):352-360.
    • (2009) J Intensive Care Med , vol.24 , Issue.6 , pp. 352-360
    • McGee, W.T.1
  • 16
    • 84870591774 scopus 로고    scopus 로고
    • LiDCO Cardiac Sensor Systems, [website home page]. Available at, Accessed July 28, 2011
    • LiDCO Cardiac Sensor Systems. Continuous, real-time cardiovascular monitoring [website home page]. Available at: http://www.lidco.com/. Accessed July 28, 2011.
    • Continuous, Real-time Cardiovascular Monitoring
  • 17
    • 84870618105 scopus 로고    scopus 로고
    • [web-site page]. Available at, Accessed July 28, 2011
    • Phillips. PiCCO: continuous cardiac output monitoring [web-site page]. Available at: http://www.healthcare.philips.com/main/products/patient_monitoring/products/picco/index.wpd. Accessed July 28, 2011.
    • PiCCO: Continuous Cardiac Output Monitoring
  • 18
    • 84870583855 scopus 로고    scopus 로고
    • Edwards Lifesciences, [website page]. Available at, Accessed July 28, 2011
    • Edwards Lifesciences. Flo Trac Sensor [website page]. Available at: http://www.edwards.com/products/mininvasive/pages/flotracsensor.aspx. Accessed July 28, 2011.
    • Flo Trac Sensor
  • 21
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121 (6):2000-2008.
    • (2002) Chest , vol.121 , Issue.6 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 22
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642-2647.
    • (2009) Crit Care Med , vol.37 , Issue.9 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 23
    • 79251547718 scopus 로고    scopus 로고
    • Stroke volume variation: From applied physiology to improved outcomes
    • Michard F. Stroke volume variation: from applied physiology to improved outcomes. Crit Care Med. 2001;39(2):402-403.
    • (2001) Crit Care Med , vol.39 , Issue.2 , pp. 402-403
    • Michard, F.1
  • 24
    • 33845958648 scopus 로고    scopus 로고
    • Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    • Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35(1):64-68.
    • (2007) Crit Care Med , vol.35 , Issue.1 , pp. 64-68
    • Osman, D.1    Ridel, C.2    Ray, P.3
  • 25
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1): 172-178.
    • (2008) Chest , vol.134 , Issue.1 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 26
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162(1):134-138.
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.1 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3
  • 27
    • 84870577533 scopus 로고    scopus 로고
    • Hemodynamic monitoring: Arterial and pulmonary artery catheters
    • In: Gabrielli A, Layon AJ, Yu M, eds., 4th ed. Philadelphia, PA: Wolters Kluwer/Lippincott Williams & Wilkins
    • Moran SE, Pei KY, Yu M. Hemodynamic monitoring: arterial and pulmonary artery catheters. In: Gabrielli A, Layon AJ, Yu M, eds. Critical care. 4th ed. Philadelphia, PA: Wolters Kluwer/Lippincott Williams & Wilkins; 2009:171-191.
    • (2009) Critical Care , pp. 171-191
    • Moran, S.E.1    Pei, K.Y.2    Yu, M.3
  • 28
    • 74549152048 scopus 로고    scopus 로고
    • Relationship of SVV to SV: Beyond Frank-Starling using arterial pressure-based technology
    • McGee WT, Horswell JL, Hatib FS, et al. Relationship of SVV to SV: beyond Frank-Starling using arterial pressure-based technology. Crit Care Med. 2006;34(12)(Suppl):A60.
    • (2006) Crit Care Med , vol.34 , Issue.SUPPL.
    • McGee, W.T.1    Horswell, J.L.2    Hatib, F.S.3
  • 29
    • 0037408132 scopus 로고    scopus 로고
    • Probing the limits of arterial pulse contour analysis to predict preload responsiveness
    • Pinsky MR. Probing the limits of arterial pulse contour analysis to predict preload responsiveness. Anesth Analg. 2003;96(5):1245-1247.
    • (2003) Anesth Analg , vol.96 , Issue.5 , pp. 1245-1247
    • Pinsky, M.R.1
  • 30
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume
    • De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31(4): 517-523.
    • (2005) Intensive Care Med , vol.31 , Issue.4 , pp. 517-523
    • de Backer, D.1    Heenen, S.2    Piagnerelli, M.3    Koch, M.4    Vincent, J.L.5
  • 31
    • 80054862153 scopus 로고    scopus 로고
    • Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume
    • Mesquida J, Kim HK, Pinsky MR. Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med. 2011;37(10):1672-1679.
    • (2011) Intensive Care Med , vol.37 , Issue.10 , pp. 1672-1679
    • Mesquida, J.1    Kim, H.K.2    Pinsky, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.