메뉴 건너뛰기




Volumn 32, Issue 5, 1998, Pages 739-748

Blood volume regulation during hemodialysis

Author keywords

Biofeedback; Blood pressure; Blood volume; Dialysis hypotension; Hemodialysis; Hypovolemia; Integrated control systems

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD VOLUME; CLINICAL ARTICLE; CLINICAL PROTOCOL; CLINICAL TRIAL; CROSSOVER PROCEDURE; FEEDBACK SYSTEM; FEMALE; HEMODIALYSIS; HUMAN; HYPOTENSION; HYPOVOLEMIA; MALE; MUSCLE CRAMP; RESISTANCE BLOOD VESSEL; SODIUM BALANCE; ULTRAFILTRATION;

EID: 0031769322     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0272-6386(98)70128-3     Document Type: Article
Times cited : (101)

References (20)
  • 1
    • 0026078098 scopus 로고
    • Dialysis hypotension: A hemodynamic analysis
    • JT Daugirdas Dialysis hypotension: A hemodynamic analysis Kidney Int 39 1991 233 246
    • (1991) Kidney Int , vol.39 , pp. 233-246
    • Daugirdas, JT1
  • 2
    • 0030637697 scopus 로고    scopus 로고
    • Clinical significance of intradialytic blood volume monitoring
    • A Santoro E Mancini Clinical significance of intradialytic blood volume monitoring Int J Artif Organs 20 1997 1 6
    • (1997) Int J Artif Organs , vol.20 , pp. 1-6
    • Santoro, A1    Mancini, E2
  • 3
    • 0027515747 scopus 로고
    • Dialysis-induced hypotension: A fresh look at pathophysiology
    • P Zucchelli A Santoro Dialysis-induced hypotension: A fresh look at pathophysiology Blood Purif 11 1993 85 98
    • (1993) Blood Purif , vol.11 , pp. 85-98
    • Zucchelli, P1    Santoro, A2
  • 4
    • 49449089219 scopus 로고
    • Parameter estimator and adaptive controller to regulate intradialytic blood volume trends
    • A Santoro M Spongano E Mancini M Rossi F Paolini P Zucchelli Parameter estimator and adaptive controller to regulate intradialytic blood volume trends Kidney Int 41 1992 1446 (abstr)
    • (1992) Kidney Int , vol.41 , pp. 1446
    • Santoro, A1    Spongano, M2    Mancini, E3    Rossi, M4    Paolini, F5    Zucchelli, P6
  • 5
    • 0028464338 scopus 로고
    • Automatic control of blood volume trends during hemodialysis
    • A Santoro E Mancini F Paolini M Spongano P Zucchelli Automatic control of blood volume trends during hemodialysis ASAIO J 40 1994 M419 M422
    • (1994) ASAIO J , vol.40 , pp. M419-M422
    • Santoro, A1    Mancini, E2    Paolini, F3    Spongano, M4    Zucchelli, P5
  • 7
    • 0028972006 scopus 로고
    • Hemoscan: A dialysis machine integrated blood volume monitor
    • F Paolini E Mancini A Bosetto A Santoro Hemoscan: A dialysis machine integrated blood volume monitor Int J Artif Organs 18 1995 487 494
    • (1995) Int J Artif Organs , vol.18 , pp. 487-494
    • Paolini, F1    Mancini, E2    Bosetto, A3    Santoro, A4
  • 11
    • 0028234683 scopus 로고
    • Prevention of hypovolemia-induced hypotension during hemodialysis by means of an optical reflection method
    • JPPM De Vries AJM Donker PMJM De Vries Prevention of hypovolemia-induced hypotension during hemodialysis by means of an optical reflection method Int J Artif Organs 17 1994 209 214
    • (1994) Int J Artif Organs , vol.17 , pp. 209-214
    • De Vries, JPPM1    Donker, AJM2    De Vries, PMJM3
  • 12
    • 0021720325 scopus 로고
    • Plasma volume recovery after ultrafiltration in patients with chronic renal failure
    • HA Koomans AB Geers EJ Dorhout Mees Plasma volume recovery after ultrafiltration in patients with chronic renal failure Kidney Int 26 1984 848 854
    • (1984) Kidney Int , vol.26 , pp. 848-854
    • Koomans, HA1    Geers, AB2    Dorhout Mees, EJ3
  • 13
    • 0027181839 scopus 로고
    • Continuous on-line optical absorbance recording of blood volume changes during hemodialysis
    • E Mancini A Santoro M Spongano F Paolini M Rossi P Zucchelli Continuous on-line optical absorbance recording of blood volume changes during hemodialysis Artif Organs 17 1993 691 694
    • (1993) Artif Organs , vol.17 , pp. 691-694
    • Mancini, E1    Santoro, A2    Spongano, M3    Paolini, F4    Rossi, M5    Zucchelli, P6
  • 14
    • 0023554479 scopus 로고
    • A new continuous hemoglobinometric measurement of blood volume during hemodialysis
    • U Schallenberg S Stiller H Mann A new continuous hemoglobinometric measurement of blood volume during hemodialysis Life Support Systems 5 1987 293 305
    • (1987) Life Support Systems , vol.5 , pp. 293-305
    • Schallenberg, U1    Stiller, S2    Mann, H3
  • 15
    • 0025092293 scopus 로고
    • A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis
    • D Scheneditz H Pogglitsch JH Horina U Binswanger A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis Kidney Int 38 1990 342 346
    • (1990) Kidney Int , vol.38 , pp. 342-346
    • Scheneditz, D1    Pogglitsch, H2    Horina, JH3    Binswanger, U4
  • 16
    • 0027624470 scopus 로고
    • Continuous measurement of blood volume using light reflection. Method and validation
    • JPPM De Vries CG Olthof V Visser PM Kouw PMJM De Vries Continuous measurement of blood volume using light reflection. Method and validation Med Biol Eng Comput 31 1993 412 415
    • (1993) Med Biol Eng Comput , vol.31 , pp. 412-415
    • De Vries, JPPM1    Olthof, CG2    Visser, V3    Kouw, PM4    De Vries, PMJM5
  • 17
    • 15144345431 scopus 로고    scopus 로고
    • Incidence of high prescribed dry weights and intradialytic morbidity as detected by continuous volume monitoring (CBVM)
    • RR Steuer D Bell J Conis Incidence of high prescribed dry weights and intradialytic morbidity as detected by continuous volume monitoring (CBVM) Nephrol Dial Transplant 11 1996 A197 (abstr)
    • (1996) Nephrol Dial Transplant , vol.11 , pp. A197
    • Steuer, RR1    Bell, D2    Conis, J3
  • 20
    • 0028185253 scopus 로고
    • The venous system and dialysis-associated hypotension
    • JP Kooman JP Van Hoff KML Leunissen The venous system and dialysis-associated hypotension Contrib Nephrol 106 1994 99 105
    • (1994) Contrib Nephrol , vol.106 , pp. 99-105
    • Kooman, JP1    Van Hoff, JP2    Leunissen, KML3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.