1
-
-
0036283553
-
Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
-
Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121(6): 2000-2008.
-
(2002)
Chest.
, vol.121
, Issue.6
, pp. 2000-2008
-
-
Michard, F.1
Teboul, J.L.2
-
2
-
-
0030057557
-
Severe sepsis in a community teaching hospital 1983-1985 and 1989-90
-
McGee WT, Steingrub JS, Callas P, Teres D. Severe sepsis in a community teaching hospital: 1983-1985 and 1989-90. J Intensive Care Med. 1996;11(1):19-22.
-
(1996)
J Intensive Care Med.
, vol.11
, Issue.1
, pp. 19-22
-
-
McGee, W.T.1
Steingrub, J.S.2
Callas, P.3
Teres, D.4
-
3
-
-
0034679107
-
Patient characteristics and ICU organizational factors that influence frequency of pulmonary artery catheterization
-
Rapoport J, Teres D, Steingrub J, Higgins T, McGee W, Lemeshow S. Patient characteristics and ICU organizational factors that influence frequency of pulmonary artery catheterization. JAMA. 2000;283(19):2559-2567.
-
(2000)
JAMA
, vol.283
, Issue.19
, pp. 2559-2567
-
-
Rapoport, J.1
Teres, D.2
Steingrub, J.3
Higgins, T.4
McGee, W.5
Lemeshow, S.6
-
4
-
-
0033945149
-
Financial impact of pulmonary artery catheterization in severe sepsis
-
McGee WT, Steingrub JS, Callas PW. Financial impact of pulmonary artery catheterization in severe sepsis. Clin Intensive Care. 2000;11(3):137-143.
-
(2000)
Clin Intensive Care
, vol.11
, Issue.3
, pp. 137-143
-
-
McGee, W.T.1
Steingrub, J.S.2
Callas, P.W.3
-
5
-
-
9544228424
-
The effectiveness of right heart catheterization in the initial care of critically ill patients
-
and the SUPPORT Investigators
-
Conners AF Jr, Speroff T, Dawson NV, et al., and the SUPPORT Investigators. The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA. 1996; 276(11):889-897.
-
(1996)
JAMA.
, vol.276
, Issue.11
, pp. 889-897
-
-
Conners Jr., A.F.1
Speroff, T.2
Dawson, N.V.3
-
6
-
-
0028275095
-
Elevation of systemic oxygen delivery in the treatment of critically ill patients
-
DOI 10.1056/NEJM199406163302404
-
Hayes MA, Timmins AC, Yau EH, Palazzo M, Hinds CJ, Watson D. Elevation of systemic oxygen delivery in the treatment of critically ill patients. N Engl J Med. 1994;330(24):1717-1722. (Pubitemid 24171030)
-
(1994)
New England Journal of Medicine
, vol.330
, Issue.24
, pp. 1717-1722
-
-
Hayes, M.A.1
Timmins, A.C.2
Yau, E.H.S.3
Palazzo, M.4
Hinds, C.J.5
Watson, D.6
-
7
-
-
0028872009
-
A trial of goal-oriented hemodynamic therapy in critically ill patients
-
Gattinoni L, Brazzi L, Pelosi P, et al. A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med. 1995;333(16):1025-1032.
-
(1995)
N Engl J Med.
, vol.333
, Issue.16
, pp. 1025-1032
-
-
Gattinoni, L.1
Brazzi, L.2
Pelosi, P.3
-
8
-
-
0029980699
-
Maximizing oxygen delivery in critically ill patients: A methodological appraisal of the evidence
-
Heyland DK, Cook DJ, King D, Kernerman P, Brun-Buisson C. Maximizing oxygen delivery in critically ill patients: a methodological appraisal of the evidence. Crit Care Med. 1996;24(3): 517-524.
-
(1996)
Crit Care Med.
, vol.24
, Issue.3
, pp. 517-524
-
-
Heyland, D.K.1
Cook, D.J.2
King, D.3
Kernerman, P.4
Brun-Buisson, C.5
-
9
-
-
0026631780
-
End-diastolic volume: A better indicator of preload in the critically ill
-
Diebel LN, Wilson RF, Tagett MG, Kline RA. End-diastolic volume: a better indicator of preload in the critically ill. Arch Surg. 1992;127(7):817-822.
-
(1992)
Arch Surg.
, vol.127
, Issue.7
, pp. 817-822
-
-
Diebel, L.N.1
Wilson, R.F.2
Tagett, M.G.3
Kline, R.A.4
-
10
-
-
0028596566
-
End-diastolic volume vs pulmonary artery wedge pressure in evaluating cardiac preload in trauma patients
-
Diebel L, Wilson RF, Heins J, Larky H, Warsow K, Wilson S. End-diastolic volume vs pulmonary artery wedge pressure in evaluating cardiac preload in trauma patients. J Trauma. 1994;37(6):950-955.
-
(1994)
J Trauma.
, vol.37
, Issue.6
, pp. 950-955
-
-
Diebel, L.1
Wilson, R.F.2
Heins, J.3
Larky, H.4
Warsow, K.5
Wilson, S.6
-
11
-
-
0033966058
-
The use of transesophageal echocardiography for preload assessment in critically ill patients
-
Tousignant CP, Walsh F, Mazer CD. The use of transesophageal echocardiography for preload assessment in critically ill patients. Anesth Analg. 2000;90(2):351-355.
-
(2000)
Anesth Analg.
, vol.90
, Issue.2
, pp. 351-355
-
-
Tousignant, C.P.1
Walsh, F.2
Mazer, C.D.3
-
12
-
-
0035092478
-
Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
-
Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119(3):867-873.
-
(2001)
Chest.
, vol.119
, Issue.3
, pp. 867-873
-
-
Feissel, M.1
Michard, F.2
Mangin, I.3
Ruyer, O.4
Faller, J.P.5
Teboul, J.L.6
-
13
-
-
0023447169
-
A comparison of hemodynamic indexes derived by invasive monitoring and two-dimensional echocardiography
-
Thys DM, Hillel Z, Goldman ME, Mindich BP, Kaplan JA. A comparison of hemodynamic indexes derived by invasive monitoring and two-dimensional echocardiography. Anesthesiology. 1987;67(5):630-634.
-
(1987)
Anesthesiology
, vol.67
, Issue.5
, pp. 630-634
-
-
Thys, D.M.1
Hillel, Z.2
Goldman, M.E.3
Mindich, B.P.4
Kaplan, J.A.5
-
14
-
-
0028100054
-
Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function
-
Cheung AT, Savino JS, Weiss SJ, Aukburg SJ, Berlin JA. Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function. Anesthesiology. 1994;81(2):376-387.
-
(1994)
Anesthesiology
, vol.81
, Issue.2
, pp. 376-387
-
-
Cheung, A.T.1
Savino, J.S.2
Weiss, S.J.3
Aukburg, S.J.4
Berlin, J.A.5
-
15
-
-
0032437998
-
Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
-
Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology. 1998;89(6): 1313-1321.
-
(1998)
Anesthesiology
, vol.89
, Issue.6
, pp. 1313-1321
-
-
Tavernier, B.1
Makhotine, O.2
Lebuffe, G.3
Dupont, J.4
Scherpereel, P.5
-
16
-
-
0033924592
-
Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
-
Michard F, Boussat S, Chemla D, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162(1):134-138.
-
(2000)
Am J Respir Crit Care Med.
, vol.162
, Issue.1
, pp. 134-138
-
-
Michard, F.1
Boussat, S.2
Chemla, D.3
-
17
-
-
0023605206
-
Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
-
Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987;67(4):498-502.
-
(1987)
Anesthesiology
, vol.67
, Issue.4
, pp. 498-502
-
-
Perel, A.1
Pizov, R.2
Cotev, S.3
-
18
-
-
0000321121
-
Respiratory changes in arterial pressure in mechanically ventilated patients
-
Vincent JL, ed. Berlin, Germany: Springer
-
Michard F, Teboul JL. Respiratory changes in arterial pressure in mechanically ventilated patients. In: Vincent JL, ed. Yearbook of Intensive Care and Emergency Medicine. Berlin, Germany: Springer; 2000:696-704.
-
(2000)
Yearbook of Intensive Care and Emergency Medicine
, pp. 696-704
-
-
Michard, F.1
Teboul, J.L.2
-
20
-
-
0032988086
-
Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP
-
Michard F, Chemla D, Richard C, et al. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit CareMed. 1999;159(3):935-939.
-
(1999)
Am J Respir Crit CareMed.
, vol.159
, Issue.3
, pp. 935-939
-
-
Michard, F.1
Chemla, D.2
Richard, C.3
-
21
-
-
0019518203
-
Effects of spontaneous ventilation on the circulation
-
Wise RA, Robotham JL, Summer WR. Effects of spontaneous ventilation on the circulation. Lung. 1981;159(4):175-186.
-
(1981)
Lung.
, vol.159
, Issue.4
, pp. 175-186
-
-
Wise, R.A.1
Robotham, J.L.2
Summer, W.R.3
-
22
-
-
0018671628
-
Current concepts: Pulsus paradoxus
-
McGregor M. Current concepts: pulsus paradoxus. N Engl J Med. 1979;301(9):480-482.
-
(1979)
N Engl J Med.
, vol.301
, Issue.9
, pp. 480-482
-
-
McGregor, M.1
-
23
-
-
2542621833
-
Cardiac output, venous return, and their regulation
-
10th ed. Philadelphia, PA: WB Saunders Company
-
Guyton AC, Hall JE. Cardiac output, venous return, and their regulation. In: Textbook of Medical Physiology. 10th ed. Philadelphia, PA: WB Saunders Company; 2000:210-222.
-
(2000)
Textbook of Medical Physiology
, pp. 210-222
-
-
Guyton, A.C.1
Hall, J.E.2
-
24
-
-
0002866507
-
Heart-lung interactions
-
Pinsky MR, Dhainaut J-F, eds. Baltimore, MD: Williams & Wilkins
-
Pinsky MR. Heart-lung interactions. In: Pinsky MR, Dhainaut J-F, eds. Pathophysiologic Foundations of Critical Care. Baltimore, MD: Williams & Wilkins; 1993:472-490.
-
(1993)
Pathophysiologic Foundations of Critical Care
, pp. 472-490
-
-
Pinsky, M.R.1
-
25
-
-
28044457897
-
Cardiovascular issues in respiratory care
-
Pinsky MR. Cardiovascular issues in respiratory care. Chest. 2005;128(5 suppl 2):592S-597S.
-
(2005)
Chest.
, vol.128
, Issue.5 SUPPL 2
-
-
Pinsky, M.R.1
-
26
-
-
34948909129
-
Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
-
Lopes MR, Oliveira MA, Pereira VO, Lemos IP, Auler JO Jr, Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care. 2007;11(5):R100.
-
(2007)
Crit Care.
, vol.11
, Issue.5
-
-
Lopes, M.R.1
Oliveira, M.A.2
Pereira, V.O.3
Lemos, I.P.4
Auler Jr., J.O.5
Michard, F.6
-
27
-
-
74549152048
-
Relationship of SVV to SV: Beyond Frank-Starling using arterial pressure-based technology
-
McGee WT, Horswell JL, Hatib FS, et al. Relationship of SVV to SV: beyond Frank-Starling using arterial pressure-based technology. Crit Care Med. 2006;34(12 suppl):A60.
-
(2006)
Crit Care Med.
, vol.34
, Issue.12 SUPPL
-
-
McGee, W.T.1
Horswell, J.L.2
Hatib, F.S.3
-
29
-
-
0000961898
-
An experimental study of blood pressure and of pulse pressure in man
-
Erlanger J, Hooker DR. An experimental study of blood pressure and of pulse pressure in man. John Hopkins Hospital Records. 1904;15:145-378.
-
(1904)
John Hopkins Hospital Records
, vol.15
, pp. 145-378
-
-
Erlanger, J.1
Hooker, D.R.2
-
30
-
-
74549179407
-
IntelliVue MP90: Networked patient monitors with portal technology for highest intensity care
-
Accessed on September 30, 2008, from
-
IntelliVue MP90: Networked patient monitors with portal technology for highest intensity care. Philips Medical Systems Brochure; 2006. Accessed on September 30, 2008, from www.medical.philips.com
-
(2006)
Philips Medical Systems Brochure
-
-
-
31
-
-
0033998711
-
Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery
-
Zollner C, Haller M, Weis M, et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth. 2000;14(2):125-129.
-
(2000)
J Cardiothorac Vasc Anesth.
, vol.14
, Issue.2
, pp. 125-129
-
-
Zollner, C.1
Haller, M.2
Weis, M.3
-
32
-
-
0036095676
-
Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm
-
Felbinger TW, Reuter DA, Eltzschig HK, Moerstedt K, Goedje O, Goetz AE. Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: evaluation of a new algorithm. J Clin Anesth. 2002;14(4):296-301.
-
(2002)
J Clin Anesth.
, vol.14
, Issue.4
, pp. 296-301
-
-
Felbinger, T.W.1
Reuter, D.A.2
Eltzschig, H.K.3
Moerstedt, K.4
Goedje, O.5
Goetz, A.E.6
-
33
-
-
0036152801
-
Reliability of a new algorithm for continuous cardiac output determination by pulse contour analysis during hemodynamic instability
-
Goedje O, Hoeke K, Goetz AE, et al. Reliability of a new algorithm for continuous cardiac output determination by pulse contour analysis during hemodynamic instability. Crit Care Med. 2002;30(1):52-129
-
(2002)
Crit Care Med.
, vol.30
, Issue.1
, pp. 52-129
-
-
Goedje, O.1
Hoeke, K.2
Goetz, A.E.3
-
34
-
-
0030831649
-
Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output
-
Kurita T, Morita K, Kato S, Kikura M, Horie M, Ikeda K. Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesthesiol. 1997;79(6):770-775.
-
(1997)
Br J Anaesthesiol.
, vol.79
, Issue.6
, pp. 770-775
-
-
Kurita, T.1
Morita, K.2
Kato, S.3
Kikura, M.4
Horie, M.5
Ikeda, K.6
-
35
-
-
0033934008
-
Cardiac output measured by lithium dilution, thermodilution and transoesophageal Doppler echocardiography in anaesthetized horses
-
Linton RA, Young LE, Marlin DJ, et al. Cardiac output measured by lithium dilution, thermodilution and transoesophageal Doppler echocardiography in anaesthetized horses. Am J Vet Res. 2001;61(7):731-737.
-
(2001)
Am J Vet Res.
, vol.61
, Issue.7
, pp. 731-737
-
-
Linton, R.A.1
Young, L.E.2
Marlin, D.J.3
-
36
-
-
0036800148
-
Cardiac output measurement without pulmonary artery or central venous catheterization: A clinical assessment of the lithium indicator dilution method
-
Garcia-Rodriguez C, Pittman J, Cassell CH, et al. Cardiac output measurement without pulmonary artery or central venous catheterization: a clinical assessment of the lithium indicator dilution method. Crit Care Med. 2002;30(10):2199-2204.
-
(2002)
Crit Care Med.
, vol.30
, Issue.10
, pp. 2199-2204
-
-
Garcia-Rodriguez, C.1
Pittman, J.2
Cassell, C.H.3
-
37
-
-
36549031653
-
Validation of a continuous, arterial pressure-based cardiac output measurement: A multicenter, prospective clinical trial
-
McGee WT, Horswell JL, Calderon J, et al. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. Crit Care. 2007;11(5): R105.
-
(2007)
Crit Care.
, vol.11
, Issue.5
-
-
McGee, W.T.1
Horswell, J.L.2
Calderon, J.3
-
38
-
-
33846669409
-
Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration
-
Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth. 2007;21(1):3-7.
-
(2007)
J Cardiothorac Vasc Anesth.
, vol.21
, Issue.1
, pp. 3-7
-
-
Manecke Jr., G.R.1
Auger, W.R.2
-
39
-
-
0036792321
-
Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery
-
Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97(4):820-826.
-
(2002)
Anesthesiology.
, vol.97
, Issue.4
, pp. 820-826
-
-
Gan, T.J.1
Soppitt, A.2
Maroof, M.3
-
40
-
-
33646859471
-
Pulmonaryartery versus central venous catheter to guide treatment of acute lung injury
-
and the The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network
-
Wheeler AP, Bernard GR, Thompson BT, et al., and the The National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. Pulmonaryartery versus central venous catheter to guide treatment of acute lung injury. N Engl J Med. 2006;354(21):2213-2224.
-
(2006)
N Engl J Med.
, vol.354
, Issue.21
, pp. 2213-2224
-
-
Wheeler, A.P.1
Bernard, G.R.2
Thompson, B.T.3
-
41
-
-
33745081608
-
Comparison of two fluid-management strategies in acute lung injury
-
and the National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS). Clinical Trials Network
-
Wiedemann HP, Wheeler AP, Bernard GR., and the National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS). Clinical Trials Network. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564-2575.
-
(2006)
N Engl J Med.
, vol.354
, Issue.24
, pp. 2564-2575
-
-
Wiedemann, H.P.1
Wheeler, A.P.2
Bernard, G.R.3
-
42
-
-
74549147676
-
Physiologic management of hemodynamics in the operating room using arterial pressurebased stroke volume and stroke volume variation
-
October; Philadelphia, PA
-
McGee W, Burns M, Kozikowski K. Physiologic management of hemodynamics in the operating room using arterial pressurebased stroke volume and stroke volume variation. Poster presentation at CHEST Conference; October 2008; Philadelphia, PA.
-
(2008)
Poster Presentation at CHEST Conference
-
-
McGee, W.1
Burns, M.2
Kozikowski, K.3
-
43
-
-
0037408132
-
Probing the limits of arterial pulse contour analysis to predict preload responsiveness
-
Pinsky MR. Probing the limits of arterial pulse contour analysis to predict preload responsiveness. Anesth Analg. 2003;96(5): 1245-1247.
-
(2003)
Anesth Analg.
, vol.96
, Issue.5
, pp. 1245-1247
-
-
Pinsky, M.R.1
-
44
-
-
0242556407
-
Change in stroke volume in response to fluid challenge: Assessment using esophageal Doppler
-
Roeck M, Jakob SM, Boehlen T, Brander L, Knuesel R, Takala J. Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler. Intensive Care Med. 2003; 29(10):1729-1735.
-
(2003)
Intensive Care Med.
, vol.29
, Issue.10
, pp. 1729-1735
-
-
Roeck, M.1
Jakob, S.M.2
Boehlen, T.3
Brander, L.4
Knuesel, R.5
Takala, J.6
-
45
-
-
26444534530
-
Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response
-
Vallee F, Fourcade O, De Soyres O, et al. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med. 2005;31(10):1388-1393.
-
(2005)
Intensive Care Med.
, vol.31
, Issue.10
, pp. 1388-1393
-
-
Vallee, F.1
Fourcade, O.2
De Soyres, O.3
-
46
-
-
0036342470
-
Meta-analysis of hemodynamic optimization in high-risk patients
-
Kern JW, Shoemaker WC. Meta-analysis of hemodynamic optimization in high-risk patients. Crit Care Med. 2002;30(8): 1686-1692.
-
(2002)
Crit Care Med.
, vol.30
, Issue.8
, pp. 1686-1692
-
-
Kern, J.W.1
Shoemaker, W.C.2
-
47
-
-
18344363998
-
Let us use the pulmonary artery catheter correctly and only when we need it
-
Pinsky MR, Vincent JL. Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med. 2005;33(5): 1119-1122.
-
(2005)
Crit Care Med.
, vol.33
, Issue.5
, pp. 1119-1122
-
-
Pinsky, M.R.1
Vincent, J.L.2
-
48
-
-
0037413466
-
A randomized, controlled trial of the use of pulmonary-artery catheters in high risk surgical patients
-
and the Canadian Critical Care Clinical Trials Group
-
Sandham JD, Hull RD, Brant RF., and the Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high risk surgical patients. N Engl J Med. 2003;348(1):5-14.
-
(2003)
N Engl J Med.
, vol.348
, Issue.1
, pp. 5-14
-
-
Sandham, J.D.1
Hull, R.D.2
Brant, R.F.3
-
49
-
-
23444461703
-
Assessment of the clinical effectiveness of pulmonary catheters in management of patients in intensive care (PAC-Man): A randomized controlled trial
-
Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary catheters in management of patients in intensive care (PAC-Man): a randomized controlled trial. Lancet. 2005;366(9484):472-477.
-
(2005)
Lancet.
, vol.366
, Issue.9484
, pp. 472-477
-
-
Harvey, S.1
Harrison, D.A.2
Singer, M.3
-
50
-
-
26044460566
-
Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: The ESCAPE trial
-
for the ESCAPE Investigators and ESCAPE Study Coordinators
-
Binanay C, Califf RM, Hasselblad V, et al., for the ESCAPE Investigators and ESCAPE Study Coordinators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA. 2005;294(13):1625-1633.
-
(2005)
JAMA
, vol.294
, Issue.13
, pp. 1625-1633
-
-
Binanay, C.1
Califf, R.M.2
Hasselblad, V.3
-
51
-
-
0345374592
-
Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
-
for the French Pulmonary Artery Catheter Study Group
-
Richard C, Warszawski J, Anguel N, et al., for the French Pulmonary Artery Catheter Study Group. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA. 2003;290(20):2713-2720.
-
(2003)
JAMA
, vol.290
, Issue.20
, pp. 2713-2720
-
-
Richard, C.1
Warszawski, J.2
Anguel, N.3
-
52
-
-
33751228164
-
Early goal-directed therapy in severe sepsis and sepsis shock revisited: Concepts, controversies, and contemporary findings
-
Otero RM, Nguyen B, Huang D, et al. Early goal-directed therapy in severe sepsis and sepsis shock revisited: concepts, controversies, and contemporary findings. Chest. 2006;130(5):1579-1595.
-
(2006)
Chest.
, vol.130
, Issue.5
, pp. 1579-1595
-
-
Otero, R.M.1
Nguyen, B.2
Huang, D.3
-
53
-
-
0035829842
-
Early goal-directed therapy in the treatment of severe sepsis and septic shock
-
and the Early Goal- Directed Therapy Collaborative Group
-
Rivers E, Nguyen B, Havstad S, et al., and the Early Goal- Directed Therapy Collaborative Group. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368-1377.
-
(2001)
N Engl J Med.
, vol.345
, Issue.19
, pp. 1368-1377
-
-
Rivers, E.1
Nguyen, B.2
Havstad, S.3
-
54
-
-
0020571420
-
Mixed venous oxygen saturation: Its role in the assessment of the critically ill patient
-
Kandel G, Aberman A. Mixed venous oxygen saturation: its role in the assessment of the critically ill patient. Arch Intern Med. 1983;143(7):1400- 1402.
-
(1983)
Arch Intern Med.
, vol.143
, Issue.7
, pp. 1400-1402
-
-
Kandel, G.1
Aberman, A.2
-
55
-
-
0017302196
-
Mixed venous oxygen tension and hyperlactatemia. Survival in severe cardiopulmonary disease
-
Kasnitz P, Druger GL, Torra F, Simmons DH. Mixed venous oxygen tension and hyperlactatemia. Survival in severe cardiopulmonary disease. JAMA. 1976;236(6):570-574.
-
(1976)
JAMA
, vol.236
, Issue.6
, pp. 570-574
-
-
Kasnitz, P.1
Druger, G.L.2
Torra, F.3
Simmons, D.H.4
-
56
-
-
0342682982
-
Monitoring O2 transport and tissue oxygenation in critically ill patients
-
Reinhart K, Eyrich K, eds. Berlin, Germany: Springer
-
Reinhart K. Monitoring O2 transport and tissue oxygenation in critically ill patients. In: Reinhart K, Eyrich K, eds. Clinical Aspects of O2 Transport and Tissue Oxygenation. Berlin, Germany: Springer; 1989:195-211.
-
(1989)
Clinical Aspects of O2 Transport and Tissue Oxygenation
, pp. 195-211
-
-
Reinhart, K.1
-
57
-
-
4143058000
-
Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
-
Reinhart K, Kuhn HU, Hartog C, Bredle DL. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med. 2004;30(8):1572-1578.
-
(2004)
Intensive Care Med.
, vol.30
, Issue.8
, pp. 1572-1578
-
-
Reinhart, K.1
Kuhn, H.U.2
Hartog, C.3
Bredle, D.L.4
-
58
-
-
0015334492
-
Central venous oxygen saturation in shock: A study in man
-
Lee J, Wright F, Barber R, Stanley L. Central venous oxygen saturation in shock: a study in man. Anesthesiology. 1972; 36(5):472.
-
(1972)
Anesthesiology
, vol.36
, Issue.5
, pp. 472
-
-
Lee, J.1
Wright, F.2
Barber, R.3
Stanley, L.4
-
59
-
-
0141453423
-
Influence of tidal volume on stroke volume variation. Does it really matter?
-
Michard F, Teboul JL, Richard C. Influence of tidal volume on stroke volume variation. Does it really matter? Intensive Care Med. 2003;29(9):1613.
-
(2003)
Intensive Care Med.
, vol.29
, Issue.9
, pp. 1613
-
-
Michard, F.1
Teboul, J.L.2
Richard, C.3
-
60
-
-
0036217518
-
Functional hemodynamic monitoring
-
Pinsky MR. Functional hemodynamic monitoring. Intensive Care Med. 2002;28(4):386-388.
-
(2002)
Intensive Care Med.
, vol.28
, Issue.4
, pp. 386-388
-
-
Pinsky, M.R.1
-
61
-
-
0242637019
-
The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients
-
Perel A. The value of functional hemodynamic parameters in hemodynamic monitoring of ventilated patients. Anaesthetist. 2003;52(11):1003-1004.
-
(2003)
Anaesthetist.
, vol.52
, Issue.11
, pp. 1003-1004
-
-
Perel, A.1
-
62
-
-
1642534620
-
Clinical Usefulness of Respiratory Variations in Arterial Pressure
-
DOI 10.1164/rccm.200211-1360CC
-
Magder S. Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med. 2004;169(2):151-155. (Pubitemid 38114527)
-
(2004)
American Journal of Respiratory and Critical Care Medicine
, vol.169
, Issue.2
, pp. 151-155
-
-
Magder, S.1
-
63
-
-
0037352554
-
Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
-
Reuter DA, Bayerlein J, Goepfert MS, et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med. 2003;29(3):476-480.
-
(2003)
Intensive Care Med.
, vol.29
, Issue.3
, pp. 476-480
-
-
Reuter, D.A.1
Bayerlein, J.2
Goepfert, M.S.3
-
64
-
-
20944442250
-
Arterial pulse pressure variation during positive pressure ventilation and passive leg raising
-
Pinsky MR, Payen D, eds. Germany: Springer-Verlag Berlin Heidelberg
-
Teboul JL, Monnet X, Richard C. Arterial pulse pressure variation during positive pressure ventilation and passive leg raising. In: Pinsky MR, Payen D, eds. Update in Intensive Care and Emergency Medicine: Functional Hemodynamic Monitoring. Germany: Springer-Verlag Berlin Heidelberg; 2005:331-343.
-
(2005)
Update in Intensive Care and Emergency Medicine: Functional Hemodynamic Monitoring
, pp. 331-343
-
-
Teboul, J.L.1
Monnet, X.2
Richard, C.3
-
65
-
-
33646577770
-
Passive leg raising predicts fluid responsiveness in the critically ill
-
Monnet X, Rienzo M, Osman D, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34(5):1559-1560.
-
(2006)
Crit Care Med.
, vol.34
, Issue.5
, pp. 1559-1560
-
-
Monnet, X.1
Rienzo, M.2
Osman, D.3
-
66
-
-
0036206081
-
Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients
-
Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G. Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest. 2002;121(4):1245-1252.
-
(2002)
Chest.
, vol.121
, Issue.4
, pp. 1245-1252
-
-
Boulain, T.1
Achard, J.M.2
Teboul, J.L.3
Richard, C.4
Perrotin, D.5
Ginies, G.6
-
67
-
-
43449086396
-
Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity
-
Teboul JL, Monnet X. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care. 2008;14(3):334-339.
-
(2008)
Curr Opin Crit Care.
, vol.14
, Issue.3
, pp. 334-339
-
-
Teboul, J.L.1
Monnet, X.2
-
68
-
-
33845681125
-
Oxygen transport and tissue oxygenation
-
Higgins TL, Steingrub JS, Kacmarek RM, Stoller JK, eds. Oxford, UK: BIOS Scientific Publishers Ltd.
-
McGee WT, Jodka P. Oxygen transport and tissue oxygenation. In: Higgins TL, Steingrub JS, Kacmarek RM, Stoller JK, eds. Cardiopulmonary Critical Care. Oxford, UK: BIOS Scientific Publishers Ltd.; 2002:35-48.
-
(2002)
Cardiopulmonary Critical Care
, pp. 35-48
-
-
McGee, W.T.1
Jodka, P.2
-
69
-
-
0345396315
-
2 uptake, critical O2 delivery, and tissue wellness
-
Pinsky MR, Dhainaut JFA, eds. Baltimore, MD: Williams & Wilkins
-
2 uptake, critical O2 delivery, and tissue wellness. In: Pinsky MR, Dhainaut JFA, eds. Pathophysiologic Foundations of Critical Care. Baltimore, MD: Williams & Wilkins; 1993:119-139.
-
(1993)
Pathophysiologic Foundations of Critical Care
, pp. 119-139
-
-
Schlichtig, R.1
|