메뉴 건너뛰기




Volumn 100 B, Issue 6, 2012, Pages 1459-1465

Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements

Author keywords

carbon fiber reinforced PEEK; friction; hip replacement; wear

Indexed keywords

BOUNDARY LUBRICATION CONDITIONS; FRICTION AND WEAR; FRICTION FACTORS; HIP REPLACEMENTS; OSTEOLYSIS; SURGICAL INTERVENTIONS; TOTAL HIP REPLACEMENT (THR); VOLUMETRIC WEAR RATES;

EID: 84863727997     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.32664     Document Type: Article
Times cited : (73)

References (50)
  • 2
    • 17144469466 scopus 로고    scopus 로고
    • Problems with wear in artificial orthopaedic joint replacements: A review
    • 447-454
    • Bolton JD,. Problems with wear in artificial orthopaedic joint replacements: A review. Key Eng Mater 2002; 230-232: 447-454.
    • (2002) Key Eng Mater , pp. 230-232
    • Bolton, J.D.1
  • 3
    • 0033637708 scopus 로고    scopus 로고
    • Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: A hip-simulator study
    • McKellop H, Shen F-w, Lu B, Campbell P, Salovey R,. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: A hip-simulator study. J Bone Joint Surg Am 2000; 82: 1708-1725.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1708-1725
    • McKellop, H.1    Shen, F.-W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 4
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement
    • Ingham E, Fisher J,. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng Part H: J Eng Med 2000; 214: 21-37.
    • (2000) Proc Inst Mech Eng Part H: J Eng Med , vol.214 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 5
    • 36849009829 scopus 로고    scopus 로고
    • Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty
    • Jacobs CA, Christensen C, Greenwald S, McKellop H,. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am 2007; 89: 2779-2786.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2779-2786
    • Jacobs, C.A.1    Christensen, C.2    Greenwald, S.3    McKellop, H.4
  • 6
    • 0033378263 scopus 로고    scopus 로고
    • Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    • Anissian HL, Stark A, Gustafson A, Good V, Clarke IC,. Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand 1999: 578-582.
    • Acta Orthop Scand , vol.1999 , pp. 578-582
    • Anissian, H.L.1    Stark, A.2    Gustafson, A.3    Good, V.4    Clarke, I.C.5
  • 7
    • 0035882726 scopus 로고    scopus 로고
    • Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
    • Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J,. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001; 22: 2191-2197.
    • (2001) Biomaterials , vol.22 , pp. 2191-2197
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Nevelos, A.B.4    Fisher, J.5
  • 10
    • 10644277228 scopus 로고    scopus 로고
    • Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions
    • Affatato S, Bersaglia G, Rocchi M, Taddei P, Fagnano C, Toni A,. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Biomaterials 2005; 26: 3259-3267.
    • (2005) Biomaterials , vol.26 , pp. 3259-3267
    • Affatato, S.1    Bersaglia, G.2    Rocchi, M.3    Taddei, P.4    Fagnano, C.5    Toni, A.6
  • 11
    • 19944421089 scopus 로고    scopus 로고
    • Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints
    • Galvin AL, Tipper JL, Ingham E, Fisher J,. Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints. Wear 2005; 259: 977-983.
    • (2005) Wear , vol.259 , pp. 977-983
    • Galvin, A.L.1    Tipper, J.L.2    Ingham, E.3    Fisher, J.4
  • 12
    • 40749130415 scopus 로고    scopus 로고
    • Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis
    • Glyn-Jones S, Isaac S, Hauptfleisch J, McLardy-Smith P, Murray DW, Gill HS,. Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis. J Arthroplasty 2008; 23: 337-343.
    • (2008) J Arthroplasty , vol.23 , pp. 337-343
    • Glyn-Jones, S.1    Isaac, S.2    Hauptfleisch, J.3    McLardy-Smith, P.4    Murray, D.W.5    Gill, H.S.6
  • 15
    • 0033630259 scopus 로고    scopus 로고
    • A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    • Goldsmith AA, Dowson D, Isaac GH, Lancaster JG,. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proc Inst Mech Eng Part H: J Eng Med 2000; 214: 39-47.
    • (2000) Proc Inst Mech Eng Part H: J Eng Med , vol.214 , pp. 39-47
    • Goldsmith, A.A.1    Dowson, D.2    Isaac, G.H.3    Lancaster, J.G.4
  • 16
    • 4744355541 scopus 로고    scopus 로고
    • The role of macrophages in osteolysis of total joint replacement
    • Ingham E, Fisher J,. The role of macrophages in osteolysis of total joint replacement. Biomaterials 2005; 26: 1271-1286.
    • (2005) Biomaterials , vol.26 , pp. 1271-1286
    • Ingham, E.1    Fisher, J.2
  • 18
    • 78649990327 scopus 로고    scopus 로고
    • Whole blood metal ion concentrations in correlation with activity level in three different metal-on-metal bearings
    • Pattyn CA, Lauwagie SN, Verdonk RC,. Whole blood metal ion concentrations in correlation with activity level in three different metal-on-metal bearings. J Arthroplasty 2011; 26: 58-64.
    • (2011) J Arthroplasty , vol.26 , pp. 58-64
    • Pattyn, C.A.1    Lauwagie, S.N.2    Verdonk, R.C.3
  • 19
    • 33750363656 scopus 로고    scopus 로고
    • Hip implants - Paper VI - Ion concentrations
    • Sargeant A, Goswami T,. Hip implants-Paper VI-Ion concentrations. Mater Des 2007; 28: 155-171.
    • (2007) Mater des , vol.28 , pp. 155-171
    • Sargeant, A.1    Goswami, T.2
  • 20
    • 78650033010 scopus 로고    scopus 로고
    • Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients
    • Yang J, Shen B, Zhou Z, Pei F, Kang P,. Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients. J Arthroplasty 2011; 26: 65-70.
    • (2011) J Arthroplasty , vol.26 , pp. 65-70
    • Yang, J.1    Shen, B.2    Zhou, Z.3    Pei, F.4    Kang, P.5
  • 21
    • 84863718484 scopus 로고    scopus 로고
    • Increased wear of hip surface replacements with high cup angle and head lateralisation in vitro
    • Leslie I, Williams S, Anderson J, Isaac G, Ingham E, Fisher J,. Increased wear of hip surface replacements with high cup angle and head lateralisation in vitro. J Biomech 2008; 41 (Suppl 1): S6-S6.
    • (2008) J Biomech , vol.41 , Issue.SUPPL. 1
    • Leslie, I.1    Williams, S.2    Anderson, J.3    Isaac, G.4    Ingham, E.5    Fisher, J.6
  • 22
    • 74249093657 scopus 로고    scopus 로고
    • Infection or allergy in the painful metal-on-metal total hip arthroplasty?
    • Biant LC, Bruce WJM, van der Wall H, Walsh WR,. Infection or allergy in the painful metal-on-metal total hip arthroplasty? J Arthroplasty 2010; 25: 334.e11-334.e16.
    • (2010) J Arthroplasty , vol.25
    • Biant, L.C.1    Bruce, W.J.M.2    Van Der Wall, H.3    Walsh, W.R.4
  • 23
    • 77957264754 scopus 로고    scopus 로고
    • A painful metal-on-metal total hip arthroplasty: A diagnostic dilemma
    • Blumenfeld TJ, Bargar WL, Campbell PA,. A painful metal-on-metal total hip arthroplasty: A diagnostic dilemma. J Arthroplasty 2010; 25: 1168 e1-e4.
    • (2010) J Arthroplasty , vol.25 , Issue.1168
    • Blumenfeld, T.J.1    Bargar, W.L.2    Campbell, P.A.3
  • 24
    • 79955990615 scopus 로고    scopus 로고
    • "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: Prevalence and metal ion study
    • Kwon Y-M, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW,. "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: Prevalence and metal ion study. J Arthroplasty 2011; 26: 511-518.
    • (2011) J Arthroplasty , vol.26 , pp. 511-518
    • Kwon, Y.-M.1    Ostlere, S.J.2    McLardy-Smith, P.3    Athanasou, N.A.4    Gill, H.S.5    Murray, D.W.6
  • 25
    • 84863728545 scopus 로고    scopus 로고
    • Ceramic squeaking: Retrieved hips and never implanted components show ceramic components alone emit the squeaking documented in vivo
    • Las Vegas, USA, Paper 161
    • Currier JH, Reinitz SD, Currier BH, Van Citters DW,. Ceramic squeaking: Retrieved hips and never implanted components show ceramic components alone emit the squeaking documented in vivo. In: Proceedings of the Orthopaedic Research Society, Las Vegas, USA, 2010. Paper 161.
    • (2010) Proceedings of the Orthopaedic Research Society
    • Currier, J.H.1    Reinitz, S.D.2    Currier, B.H.3    Van Citters, D.W.4
  • 27
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips: The importance of acetabular component orientation
    • Walter WL, O'Toole GC, Walter WK, Ellis A, Zicat BA,. Squeaking in ceramic-on-ceramic hips: The importance of acetabular component orientation. Arthroplasty 2007; 22: 496-503.
    • (2007) Arthroplasty , vol.22 , pp. 496-503
    • Walter, W.L.1    O'Toole, G.C.2    Walter, W.K.3    Ellis, A.4    Zicat, B.A.5
  • 28
    • 18844483061 scopus 로고    scopus 로고
    • Squeaking and neck-socket impingement in a ceramic total hip arthroplasty
    • (Trans Tech Publications Ltd., Sydney, NSW, Australia)
    • Eickmann T, Manaka M, Clarke I, Gustafson A,. Squeaking and neck-socket impingement in a ceramic total hip arthroplasty. Key Eng Mater 2003: 849-852 (Trans Tech Publications Ltd., Sydney, NSW, Australia).
    • (2003) Key Eng Mater , pp. 849-852
    • Eickmann, T.1    Manaka, M.2    Clarke, I.3    Gustafson, A.4
  • 29
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • Kurtz SM, Devine JN,. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007; 28: 4845-4869.
    • (2007) Biomaterials , vol.28 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 30
    • 0032201988 scopus 로고    scopus 로고
    • Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement
    • Wang A, Lin R, Polineni VK, Essner A, Stark C, Dumbleton JH,. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement. Tribol Int 1998; 31: 661-667.
    • (1998) Tribol Int , vol.31 , pp. 661-667
    • Wang, A.1    Lin, R.2    Polineni, V.K.3    Essner, A.4    Stark, C.5    Dumbleton, J.H.6
  • 31
    • 73149087679 scopus 로고    scopus 로고
    • The wear performance of PEEK-OPTIMA based self-mating couples
    • Scholes SC, Unsworth A,. The wear performance of PEEK-OPTIMA based self-mating couples. Wear 2010; 268: 380-387.
    • (2010) Wear , vol.268 , pp. 380-387
    • Scholes, S.C.1    Unsworth, A.2
  • 32
    • 58549086944 scopus 로고    scopus 로고
    • Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials
    • Scholes S, Unsworth A,. Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials. J Mater Sci: Mater Med 2009; 20: 163-170.
    • (2009) J Mater Sci: Mater Med , vol.20 , pp. 163-170
    • Scholes, S.1    Unsworth, A.2
  • 33
    • 47649088851 scopus 로고    scopus 로고
    • Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head
    • Scholes SC, Inman IA, Unsworth A, Jones E,. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head. Proc Inst Mech Eng Part H: J Eng Med 2008; 222: 273-283.
    • (2008) Proc Inst Mech Eng Part H: J Eng Med , vol.222 , pp. 273-283
    • Scholes, S.C.1    Inman, I.A.2    Unsworth, A.3    Jones, E.4
  • 35
    • 74049104568 scopus 로고    scopus 로고
    • The fundamentals of biotribology and its application to spine arthroplasty
    • Harper ML, Dooris A, Paré PE,. The fundamentals of biotribology and its application to spine arthroplasty. SAS J 2009; 3: 125-132.
    • (2009) SAS J , vol.3 , pp. 125-132
    • Harper, M.L.1    Dooris, A.2    Paré, P.E.3
  • 37
    • 0033252596 scopus 로고    scopus 로고
    • A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    • Barbour P, Stone M, Fisher J,. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proc Inst Mech Eng Part H: J Eng Med 1999; 213: 455-467.
    • (1999) Proc Inst Mech Eng Part H: J Eng Med , vol.213 , pp. 455-467
    • Barbour, P.1    Stone, M.2    Fisher, J.3
  • 38
    • 0034233164 scopus 로고    scopus 로고
    • The effects of material combination and lubricant on the friction of total hip prostheses
    • Scholes, Unsworth A, Hall RM, Scott R,. The effects of material combination and lubricant on the friction of total hip prostheses. Wear 2000; 241: 209-213.
    • (2000) Wear , vol.241 , pp. 209-213
    • Scholes1    Unsworth, A.2    Hall, R.M.3    Scott, R.4
  • 40
    • 33749364076 scopus 로고    scopus 로고
    • The effect of proteins on the friction and lubrication of artificial joints
    • Scholes, Unsworth A,. The effect of proteins on the friction and lubrication of artificial joints. Proc Inst Mech Eng Part H: J Eng Med 2006; 220: 687-693.
    • (2006) Proc Inst Mech Eng Part H: J Eng Med , vol.220 , pp. 687-693
    • Scholes1    Unsworth, A.2
  • 41
    • 0035236287 scopus 로고    scopus 로고
    • New joints for the Millennium: Wear control in total replacement hip joints
    • Dowson D,. New joints for the Millennium: Wear control in total replacement hip joints. Proc Inst Mech Eng Part H: J Eng Med 2001; 215: 335-358.
    • (2001) Proc Inst Mech Eng Part H: J Eng Med , vol.215 , pp. 335-358
    • Dowson, D.1
  • 43
    • 0035482840 scopus 로고    scopus 로고
    • Effect of carbon fibre reinforcement in the frictional behaviour of Peek in a water lubricated environment
    • Davim JP, Marques N, Baptista AM,. Effect of carbon fibre reinforcement in the frictional behaviour of Peek in a water lubricated environment. Wear 2001; 251: 1100-1104.
    • (2001) Wear , vol.251 , pp. 1100-1104
    • Davim, J.P.1    Marques, N.2    Baptista, A.M.3
  • 45
    • 79960034079 scopus 로고    scopus 로고
    • Heat generated by hip resurfacing prostheses: An in-vivo pilot study
    • Pritchett JW,. Heat generated by hip resurfacing prostheses: An in-vivo pilot study. J Long Term Eff Med Implants 2011; 21: 55-62.
    • (2011) J Long Term Eff Med Implants , vol.21 , pp. 55-62
    • Pritchett, J.W.1
  • 46
    • 12944336407 scopus 로고    scopus 로고
    • The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements
    • Mai MT, Schmalzried TP, Dorey FJ, Campbell PA, Amstutz HC,. The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements. J Bone Joint Surg Am 1996; 78: 505-511.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 505-511
    • Mai, M.T.1    Schmalzried, T.P.2    Dorey, F.J.3    Campbell, P.A.4    Amstutz, H.C.5
  • 47
    • 0043065547 scopus 로고    scopus 로고
    • Effect of fluid absorption on the wear resistance of UHMWPE orthopedic bearing surfaces
    • Yao JQ, Blanchet TA, Murphy DJ, Laurent MP,. Effect of fluid absorption on the wear resistance of UHMWPE orthopedic bearing surfaces. Wear 2003; 255: 1113-1120.
    • (2003) Wear , vol.255 , pp. 1113-1120
    • Yao, J.Q.1    Blanchet, T.A.2    Murphy, D.J.3    Laurent, M.P.4
  • 50
    • 77956967960 scopus 로고    scopus 로고
    • Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo
    • Utzschneider S, Becker F, Grupp TM, Sievers B, Paulus A, Gottschalk O, Jansson V,. Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. Acta Biomater 2010; 6: 4296-4304.
    • (2010) Acta Biomater , vol.6 , pp. 4296-4304
    • Utzschneider, S.1    Becker, F.2    Grupp, T.M.3    Sievers, B.4    Paulus, A.5    Gottschalk, O.6    Jansson, V.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.