Evaluation of stroke volume variation obtained by the flotrac™/Vigileo™ system to guide preoperative fluid therapy in patients undergoing brain surgery

Author keywords

Brain surgery; Flotrac vigileo system; Fluid therapy; Haemodynamic Stability; Stroke volume variation

Indexed keywords

FENTANYL; MIDAZOLAM; PROPOFOL; RINGER LACTATE SOLUTION; SEVOFLURANE; VECURONIUM;

EID: 84863102776     PISSN: 03000605     EISSN: None     Source Type: Journal    
DOI: 10.1177/147323001204000338     Document Type: Article
Times cited : (19)

References (28)
  • 1
    • 0029989413 scopus 로고    scopus 로고
    • Guidelines for cerebral perfusion pressure
    • Brain Trauma Foundation
    • Guidelines for cerebral perfusion pressure. Brain Trauma Foundation. J Neurotrauma 1996; 13: 693-697.
    • (1996) J Neurotrauma , vol.13 , pp. 693-697
  • 2
    • 0642338453 scopus 로고    scopus 로고
    • Effects of intravenous fluid restriction on postoperative complications: Comparison of two perioperative fluid regimens: A randomized assessor-blinded multicenter trial
    • Brandstrup B, Tønnesen H, Beier-Holgersen R, et al: Effects of intravenous fluid restriction on postoperative complications: comparison of two perioperative fluid regimens: a randomized assessor-blinded multicenter trial. Ann Surg 2003; 238: 641-648.
    • (2003) Ann Surg , vol.238 , pp. 641-648
    • Brandstrup, B.1    Tønnesen, H.2    Beier-Holgersen, R.3
  • 3
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • Feissel M, Michard F, Mangin I, et al: Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119: 867-873.
    • (2001) Chest , vol.119 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3
  • 4
    • 0032437998 scopus 로고    scopus 로고
    • Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • Tavernier B, Makhotine O, Lebuffe G, et al: Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89: 1313-1321.
    • (1998) Anesthesiology , vol.89 , pp. 1313-1321
    • Tavernier, B.1    Makhotine, O.2    Lebuffe, G.3
  • 5
    • 9744244186 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in patients during cardiac surgery
    • Rex S, Brose S, Metzelder S, et al: Prediction of fluid responsiveness in patients during cardiac surgery. Br J Anaesth 2004; 93: 782-788.
    • (2004) Br J Anaesth , vol.93 , pp. 782-788
    • Rex, S.1    Brose, S.2    Metzelder, S.3
  • 6
    • 24744434154 scopus 로고    scopus 로고
    • Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
    • Wiesenack C, Fiegl C, Keyser A, et al: Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol 2005; 22: 658-665.
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 658-665
    • Wiesenack, C.1    Fiegl, C.2    Keyser, A.3
  • 7
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • Michard F: Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103: 419-428.
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 8
    • 0037348762 scopus 로고    scopus 로고
    • Fluid responsiveness in mechanically ventilated patients: A review of indices used in intensive care
    • Bendjelid K, Romand JA: Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med 2003; 29: 352-360.
    • (2003) Intensive Care Med , vol.29 , pp. 352-360
    • Bendjelid, K.1    Romand, J.A.2
  • 9
    • 20644471623 scopus 로고    scopus 로고
    • Assessment of indices of preload and volume responsiveness
    • Pinsky MR, Teboul JL: Assessment of indices of preload and volume responsiveness. Curr Opin Crit Care 2005; 11: 235-239.
    • (2005) Curr Opin Crit Care , vol.11 , pp. 235-239
    • Pinsky, M.R.1    Teboul, J.L.2
  • 10
    • 0035080242 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • Berkenstadt H, Margalit N, Hadani M, et al: Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001; 92: 984-989.
    • (2001) Anesth Analg , vol.92 , pp. 984-989
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3
  • 11
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, et al: Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162: 134-138.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3
  • 12
    • 26444534530 scopus 로고    scopus 로고
    • Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response
    • Vallée F, Fourcade O, De Soyres O, et al: Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med 2005; 31: 1388-1393.
    • (2005) Intensive Care Med , vol.31 , pp. 1388-1393
    • Vallée, F.1    Fourcade, O.2    de Soyres, O.3
  • 13
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, et al: Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007; 99: 343-348.
    • (2007) Br J Anaesth , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3
  • 14
    • 36649018972 scopus 로고    scopus 로고
    • Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
    • Cannesson M, Attof Y, Rosamel P, et al: Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol 2007; 24: 832-839.
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 832-839
    • Cannesson, M.1    Attof, Y.2    Rosamel, P.3
  • 15
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • Biais M, Nouette-Gaulain K, Cottenceau V, et al: Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008; 106: 1480-1486.
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 16
    • 75449120090 scopus 로고    scopus 로고
    • The FloTrac™ system-measurement of stroke volume and the assessment of dynamic fluid loading
    • Hashim B, Lerner AB: The FloTrac™ system-measurement of stroke volume and the assessment of dynamic fluid loading. Int Anesthesiol Clin 2010; 48: 45-56.
    • (2010) Int Anesthesiol Clin , vol.48 , pp. 45-56
    • Hashim, B.1    Lerner, A.B.2
  • 17
    • 77955691283 scopus 로고    scopus 로고
    • Pro: The FloTrac device should be used to follow cardiac output in cardiac surgical patients
    • Manecke GR Jr: Pro: the FloTrac device should be used to follow cardiac output in cardiac surgical patients. J Cardiothorac Vasc Anesth 2010; 24: 706-708.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 706-708
    • Manecke Jr., G.R.1
  • 18
    • 77955697306 scopus 로고    scopus 로고
    • Con: The FloTrac device should not be used to follow cardiac output in cardiac surgical patients
    • Singh S, Taylor MA: Con: the FloTrac device should not be used to follow cardiac output in cardiac surgical patients. J Cardiothorac Vasc Anesth 2010; 24: 709-711.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 709-711
    • Singh, S.1    Taylor, M.A.2
  • 19
    • 43249120878 scopus 로고    scopus 로고
    • Stroke volume variation obtained with FloTrac/Vigileo fails to predict fluid responsiveness in coronary artery bypass graft patients
    • de Waal EE, Rex S, Kruitwagen CL, et al: Stroke volume variation obtained with FloTrac/Vigileo fails to predict fluid responsiveness in coronary artery bypass graft patients. Br J Anaesth 2008; 100: 725-726.
    • (2008) Br J Anaesth , vol.100 , pp. 725-726
    • de Waal, E.E.1    Rex, S.2    Kruitwagen, C.L.3
  • 20
    • 69049096115 scopus 로고    scopus 로고
    • Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively
    • Lahner D, Kabon B, Marschalek C: Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively. Br J Anaesth 2009; 103: 346-351.
    • (2009) Br J Anaesth , vol.103 , pp. 346-351
    • Lahner, D.1    Kabon, B.2    Marschalek, C.3
  • 21
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • Cannesson M, Musard H, Desebbe O, et al: The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 2009; 108: 513-517.
    • (2009) Anesth Analg , vol.108 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3
  • 22
    • 7044281135 scopus 로고    scopus 로고
    • American Society of Anesthesiologists (ASA): Park Ridge: ASA (available at)
    • American Society of Anesthesiologists (ASA): ASA Physical Status Classification System. Park Ridge: ASA (available at http://www.asahq.org/ Home/For-Members/Clinical-Information/ASAPhysical-Status-Classification-System).
    • ASA Physical Status Classification System
  • 23
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    • Hofer CK, Senn A, Weibel L, et al: Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system. Crit Care 2008; 12: R82.
    • (2008) Crit Care , vol.12
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3
  • 24
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983; 148: 839-843.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 25
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • Hofer CK, Müller SM, Furrer L, et al: Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005; 128: 848-854.
    • (2005) Chest , vol.128 , pp. 848-854
    • Hofer, C.K.1    Müller, S.M.2    Furrer, L.3
  • 26
    • 0842284105 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    • Marx G, Cope T, McCrossan L, et al: Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesthesiol 2004; 21: 132-138.
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 132-138
    • Marx, G.1    Cope, T.2    McCrossan, L.3
  • 27
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • Reuter DA, Kirchner A, Felbinger TW, et al: Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003; 31: 1399-1404.
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3
  • 28
    • 78049343101 scopus 로고    scopus 로고
    • Minimally invasive measurement of cardiac output during surgery and critical care: A meta-analysis of accuracy and precision
    • Peyton PJ, Chong SW: Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 2010; 113: 1220-
    • (2010) Anesthesiology , vol.113 , pp. 1220-1235
    • Peyton, P.J.1    Chong, S.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.