메뉴 건너뛰기




Volumn 31, Issue 10, 2005, Pages 1388-1393

Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response

Author keywords

Circulatory failure; Esophageal Doppler; Flow time; Fluid challenge; Systolic output index

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; FEMALE; FLUID FLOW; FLUID THERAPY; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; INTENSIVE CARE; MAJOR CLINICAL STUDY; MALE; PATIENT MONITORING; PREDICTION; RELIABILITY; RESUSCITATION;

EID: 26444534530     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-005-2768-0     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 3242775982 scopus 로고    scopus 로고
    • Surviving sepsis campaign guidelines for management of severe sepsis and septic shock
    • Dellinger RP, Carlet JM, Gerlach H, Ramsey G, Levy M (2004) Surviving sepsis campaign guidelines for management of severe sepsis and septic shock. Crit Care Med 32:858-873
    • (2004) Crit Care Med , vol.32 , pp. 858-873
    • Dellinger, R.P.1    Carlet, J.M.2    Gerlach, H.3    Ramsey, G.4    Levy, M.5
  • 2
    • 0032894367 scopus 로고    scopus 로고
    • Fatal postoperative pulmonary edema: Pathogenesis and literature review
    • Arieff AI (1999) Fatal postoperative pulmonary edema: pathogenesis and literature review. Chest 115:1371-1377
    • (1999) Chest , vol.115 , pp. 1371-1377
    • Arieff, A.I.1
  • 6
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL (2001) Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119:867-873
    • (2001) Chest , vol.119 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.P.5    Teboul, J.L.6
  • 7
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE (2003) Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 31:1399-1404
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6    Goetz, A.E.7
  • 8
    • 0036219991 scopus 로고    scopus 로고
    • Volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE (2002) Volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 28:392-398
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3    Kilger, E.4    Goedje, O.5    Lamm, P.6    Goetz, A.E.7
  • 9
    • 0030879480 scopus 로고    scopus 로고
    • The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor
    • Krishnamurthy B, McMurray TJ, McClean E (1997) The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation. A comparison with the continuous cardiac output monitor. Anaesthesia 52:624-629
    • (1997) Anaesthesia , vol.52 , pp. 624-629
    • Krishnamurthy, B.1    McMurray, T.J.2    McClean, E.3
  • 11
    • 0032975804 scopus 로고    scopus 로고
    • Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: Transoesophageal Doppler versus continuous thermodilution
    • Baillard C, Cohen Y, Fosse JP, Karoubi P, Hoang P, Cupa M (1999) Haemodynamic measurements (continuous cardiac output and systemic vascular resistance) in critically ill patients: transoesophageal Doppler versus continuous thermodilution. Anaesth Intensive Care 27:33-37
    • (1999) Anaesth Intensive Care , vol.27 , pp. 33-37
    • Baillard, C.1    Cohen, Y.2    Fosse, J.P.3    Karoubi, P.4    Hoang, P.5    Cupa, M.6
  • 12
    • 0029928910 scopus 로고    scopus 로고
    • A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination
    • Keyl C, Rodig G, Lemberger P, Hobbhahn J (1996) A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination. Eur J Anaesthesiol 13:136-142
    • (1996) Eur J Anaesthesiol , vol.13 , pp. 136-142
    • Keyl, C.1    Rodig, G.2    Lemberger, P.3    Hobbhahn, J.4
  • 13
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 315:909-912
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 14
    • 0036712155 scopus 로고    scopus 로고
    • Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery
    • Conway DH, Mayall R, Abdul-Latif MS, Gilligan S, Tackaberry C (2002) Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery. Anaesthesia 57:845-849
    • (2002) Anaesthesia , vol.57 , pp. 845-849
    • Conway, D.H.1    Mayall, R.2    Abdul-Latif, M.S.3    Gilligan, S.4    Tackaberry, C.5
  • 15
    • 0036139802 scopus 로고    scopus 로고
    • Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures
    • Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65-71
    • (2002) Br J Anaesth , vol.88 , pp. 65-71
    • Venn, R.1    Steele, A.2    Richardson, P.3    Poloniecki, J.4    Grounds, M.5    Newman, P.6
  • 17
    • 0026874127 scopus 로고
    • Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis
    • American College of Chest Physicians/ Society of Critical Care Medicine Consensus Conference (1992) Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Crit Care Med 20:864-874
    • (1992) Crit Care Med , vol.20 , pp. 864-874
  • 18
    • 0027132478 scopus 로고
    • New Simplified Acute Physiology Score (SAPS II) based on a European/North American Multicenter Study
    • Legall J, Lemeshow S, Saulnier F (1993) New Simplified Acute Physiology Score (SAPS II) based on a European/North American Multicenter Study. JAMA 270:2957-2963
    • (1993) JAMA , vol.270 , pp. 2957-2963
    • Legall, J.1    Lemeshow, S.2    Saulnier, F.3
  • 19
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839-843
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 20
    • 0032940509 scopus 로고    scopus 로고
    • Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients
    • Madan AK, UyBarreta VV, Aliabadi-Wahle S, Jesperson R, Hartz RS, Flint LM, Steinberg SM (1999) Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma 46:607-611
    • (1999) J Trauma , vol.46 , pp. 607-611
    • Madan, A.K.1    UyBarreta, V.V.2    Aliabadi-Wahle, S.3    Jesperson, R.4    Hartz, R.S.5    Flint, L.M.6    Steinberg, S.M.7
  • 22
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121:2000-2008
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 23


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.