메뉴 건너뛰기




Volumn 6, Issue , 2007, Pages 4296-4299

Four-layer DOI detector with a relative offset in animal PET system

Author keywords

[No Author keywords available]

Indexed keywords

CRYSTALLOGRAPHY; IMAGING TECHNIQUES; LUTETIUM; PLASTIC BOTTLES; POSITRON ANNIHILATION SPECTROSCOPY; POSITRON EMISSION TOMOGRAPHY; POWDERS;

EID: 48149111520     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4437066     Document Type: Conference Paper
Times cited : (8)

References (6)
  • 1
    • 0024610834 scopus 로고
    • PET system calibrations and corrections for quantitative and spatially accurate images
    • E. J. Hoffman, T. M. Guerreo, et al., "PET system calibrations and corrections for quantitative and spatially accurate images," IEEE Trans. Nucl. Sci., vol. 36, pp. 1108-1112, 1989.
    • (1989) IEEE Trans. Nucl. Sci , vol.36 , pp. 1108-1112
    • Hoffman, E.J.1    Guerreo, T.M.2
  • 2
    • 0032136644 scopus 로고    scopus 로고
    • Parallax correction in PET using depth of interaction information
    • L. R. MacDonald, M. Dahlbom, "Parallax correction in PET using depth of interaction information," IEEE Trans. Nucl. Sci. vol. 45, pp. 2232-2237, 1998.
    • (1998) IEEE Trans. Nucl. Sci , vol.45 , pp. 2232-2237
    • MacDonald, L.R.1    Dahlbom, M.2
  • 3
    • 0038720472 scopus 로고    scopus 로고
    • Pulse Shape Discrimination of LSO and LuYAP Scintillators for Depth of Interaction Detection in PET
    • M. Streun, G. Brandenburg, et al., " Pulse Shape Discrimination of LSO and LuYAP Scintillators for Depth of Interaction Detection in PET," IEEE Trans. Nucl. Sci. vol. 50, pp. 344-347, 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 344-347
    • Streun, M.1    Brandenburg, G.2
  • 4
    • 0142063371 scopus 로고    scopus 로고
    • Optimizing Positron Readout Circuits in Positron Emission Tomography Front-End Electronics
    • N. Zhang, C. J. Thompson, et al., " Optimizing Positron Readout Circuits in Positron Emission Tomography Front-End Electronics," IEEE Trnas. Nucl. Sci. vol. 50, No. 5, pp. 1625, 2003.
    • (2003) IEEE Trnas. Nucl. Sci , vol.50 , Issue.5 , pp. 1625
    • Zhang, N.1    Thompson, C.J.2
  • 5
    • 2342506516 scopus 로고    scopus 로고
    • Performance of a PET detector with a 256ch flat panel PS-PMT
    • N. Inadama, H. Murayama, et al., "Performance of a PET detector with a 256ch flat panel PS-PMT," IEEE Trans. Nucl. Sci., vol. 51, pp. 58-62, 2004..
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , pp. 58-62
    • Inadama, N.1    Murayama, H.2
  • 6
    • 48149101304 scopus 로고    scopus 로고
    • DOI Calibration for PET Detectors with Dual-Ended Readout by PSAPDs
    • Y. Yang, J. Qi, et al., "DOI Calibration for PET Detectors with Dual-Ended Readout by PSAPDs," Proc. IEEE NSS-MIC Conf., M 03-4, 2007.
    • (2007) Proc. IEEE NSS-MIC Conf , vol.1000 , pp. 03-04
    • Yang, Y.1    Qi, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.