Volumn 54, Issue 6, 2009, Pages 1757-1771

Continuous depth-of-interaction encoding using phosphor-coated scintillators

Author keywords

[No Author keywords available]

Indexed keywords

COATING METHODS; DECAY TIME; DEPTH OF INTERACTIONS; DEPTH-OF-INTERACTION INFORMATIONS; FULL WIDTH HALF MAXIMUMS; GALLIUM OXIDES; INTERACTION DEPTHS; LIGHT PULSE DECAY TIME; LSO CRYSTALS; LSO SCINTILLATORS; LUTETIUM OXY-ORTHOSILICATE; PHOSPHOR POWDERS; PULSE SHAPES; PULSE-SHAPE DISCRIMINATIONS; SCINTILLATION LIGHTS; THICK ARRAYS; THIN LAYERS;

EID: 63649092601     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/6/023     Document Type: Article
Times cited : (55)

References (17)
  • 1
    • 34247281562 scopus 로고    scopus 로고
    • Comparison of pulse shape discrimination methods for phoswich and CsI:Tl detectors
    • Chandrikamohan P and DeVol T A 2007 Comparison of pulse shape discrimination methods for phoswich and CsI:Tl detectors IEEE Trans. Nucl. Sci. 54 398-403
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.2 , pp. 398-403
    • Chandrikamohan, P.1    Devol, T.A.2
  • 2
    • 34249093003 scopus 로고    scopus 로고
    • Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector
    • Du H, Yang Y and Cherry S R 2007 Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector Phys. Med. Biol. 52 2499-514
    • (2007) Phys. Med. Biol. , vol.52 , Issue.9 , pp. 2499-2514
    • Du, H.1    Yang, Y.2    Cherry, S.R.3
  • 3
    • 42449159363 scopus 로고    scopus 로고
    • Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out
    • Du H, Yang Y and Cherry S R 2008 Comparison of four depth-encoding PET detector modules with wavelength shifting (WLS) and optical fiber read-out Phys. Med. Biol. 53 1829-42
    • (2008) Phys. Med. Biol. , vol.53 , Issue.7 , pp. 1829-1842
    • Du, H.1    Yang, Y.2    Cherry, S.R.3
  • 4
    • 13244295721 scopus 로고    scopus 로고
    • Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors
    • Judenhofer M S, Pichler B J and Cherry S R 2005 Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors Phys. Med. Biol. 50 29-44
    • (2005) Phys. Med. Biol. , vol.50 , Issue.1 , pp. 29-44
    • Judenhofer, M.S.1    Pichler, B.J.2    Cherry, S.R.3
  • 5
    • 0034825229 scopus 로고    scopus 로고
    • Development of a depth of interaction detector for (gamma)-rays
    • Liu H, Omura T, Watanabe M and Yamashita T 2001 Development of a depth of interaction detector for (gamma)-rays Nucl. Instrum. Methods A 459 182-90
    • (2001) Nucl. Instrum. Methods , vol.459 , Issue.1-2 , pp. 182-190
    • Liu, H.1    Omura, T.2    Watanabe, M.3    Yamashita, T.4
  • 8
    • 0028494319 scopus 로고
    • Design studies for a PET detector module using a pin photodiode to measure depth of interaction
    • Moses W W and Derenzo S E 1994 Design studies for a PET detector module using a pin photodiode to measure depth of interaction IEEE Trans. Nucl. Sci. 41 1441-5
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4 , pp. 1441-1445
    • Moses, W.W.1    Derenzo, S.E.2
  • 10
    • 33846384026 scopus 로고    scopus 로고
    • Raytest ClearPET(TM), a new generation small animal PET scanner
    • Sempere Roldan P et al 2007 Raytest ClearPET(TM), a new generation small animal PET scanner Nucl. Instrum. Methods A 571 498-501
    • (2007) Nucl. Instrum. Methods , vol.571 , Issue.1-2 , pp. 498-501
    • Sempere Roldan, P.1    Al, E.2
  • 11
    • 0030164341 scopus 로고    scopus 로고
    • Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT
    • Siegel S, Silverman R W and Cherry S R 1996 Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT IEEE Trans. Nucl. Sci. 43 1634-41
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1634-1641
    • Siegel, S.1    Silverman, R.W.2    Cherry, S.R.3
  • 13
    • 34247229328 scopus 로고    scopus 로고
    • Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner
    • Wang Y, Seidel J, Tsui B M W, Vaquero J J and Pomper M G 2006 Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner J. Nucl. Med. 47 1891-900
    • (2006) J. Nucl. Med. , vol.47 , Issue.11 , pp. 1891-1900
    • Wang, Y.1    Seidel, J.2    Tsui, B.M.W.3    Vaquero, J.J.4    Pomper, M.G.5
  • 15
    • 23844544833 scopus 로고    scopus 로고
    • Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout
    • Worstell W et al 2004 Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout IEEE Nucl. Sci. Symp. Conf. Record pp 3280-4
    • (2004) IEEE Nucl. Sci. Symp. Conf. Record , vol.5 , pp. 3280-3284
    • Worstell, W.1    Al, E.2
  • 16
    • 33645990583 scopus 로고    scopus 로고
    • Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes
    • Yang Y, Dokhale P A, Silverman R W, Shah K S, McClish M A, Farrell R, Entine G and Cherry S R 2006 Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes Phys. Med. Biol. 51 2131-42
    • (2006) Phys. Med. Biol. , vol.51 , Issue.9 , pp. 2131-2142
    • Yang, Y.1    Dokhale, P.A.2    Silverman, R.W.3    Shah, K.S.4    McClish, M.A.5    Farrell, R.6    Entine, G.7    Cherry, S.R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.