메뉴 건너뛰기




Volumn 6, Issue 5, 2012, Pages 4375-4381

Highly sensitive diagnostic assay for the detection of protein biomarkers using microresonators and multifunctional nanoparticles

Author keywords

Immunoassay; Magnetic nanoparticles; Microresonators; Photocatalyst

Indexed keywords

CRYSTALLINE-TIO; DETECTION LIMITS; DIAGNOSTIC ASSAYS; FREQUENCY CHANGES; HUMAN SERUM; HYBRID NANOPARTICLE; IMMUNOASSAY; INTERLEUKIN-6; MAGNETIC NANOPARTICLES; MICRO RESONATORS; MICRO-CANTILEVERS; MICROCANTILEVER ARRAYS; MULTI-FUNCTIONAL NANOPARTICLES; PHOTO-CATALYTIC; SENSITIVE DETECTION; SILICON CANTILEVER; SILICON MICROCANTILEVERS; SILVER REDUCTION; SOLVOTHERMAL REACTIONS;

EID: 84862845495     PISSN: 19360851     EISSN: 1936086X     Source Type: Journal    
DOI: 10.1021/nn301071c     Document Type: Article
Times cited : (55)

References (44)
  • 1
    • 14644439267 scopus 로고    scopus 로고
    • Cancer nanotechnology: Opportunities and challenges
    • Ferrari, M. Cancer Nanotechnology: Opportunities and Challenges. Nat. Rev. Cancer 2005, 5, 161-171.
    • (2005) Nat. Rev. Cancer , vol.5 , pp. 161-171
    • Ferrari, M.1
  • 2
    • 34547599483 scopus 로고    scopus 로고
    • Biomedical and clinical applications of immunoassays and immunosensors for tumor markers
    • Wu, J.; Fu, Z. F.; Yan, F.; Ju, H. X. Biomedical and Clinical Applications of Immunoassays and Immunosensors for Tumor Markers. Trends Anal. Chem. 2007, 26, 679-688.
    • (2007) Trends Anal. Chem. , vol.26 , pp. 679-688
    • Wu, J.1    Fu, Z.F.2    Yan, F.3    Ju, H.X.4
  • 3
    • 80054040693 scopus 로고    scopus 로고
    • Synthesis of silver nanoparticle-hollow titanium phosphate sphere hybrid as a label for ultrasensitive electrochemical detection of human interleukin-6
    • Peng, J.; Feng, L. N.; Ren, Z. J.; Jiang, L. P.; Zhu, J. J. Synthesis of Silver Nanoparticle-Hollow Titanium Phosphate Sphere Hybrid as a Label for Ultrasensitive Electrochemical Detection of Human Interleukin-6. Small 2011, 7, 2921-2928.
    • (2011) Small , vol.7 , pp. 2921-2928
    • Peng, J.1    Feng, L.N.2    Ren, Z.J.3    Jiang, L.P.4    Zhu, J.J.5
  • 4
    • 77951089259 scopus 로고    scopus 로고
    • Ultrasensitive electrochemical immunosensor for oral cancer biomarker IL-6 using carbon nanotube forest electrodes and multilabel amplification
    • Malhotra, R.; Patel, V.; Vaque, J. P.; Gutkind, J. S.; Rusling, J. F. Ultrasensitive Electrochemical Immunosensor for Oral Cancer Biomarker IL-6 Using Carbon Nanotube Forest Electrodes and Multilabel Amplification. Anal. Chem. 2010, 82, 3118-3123.
    • (2010) Anal. Chem. , vol.82 , pp. 3118-3123
    • Malhotra, R.1    Patel, V.2    Vaque, J.P.3    Gutkind, J.S.4    Rusling, J.F.5
  • 5
    • 70350447153 scopus 로고    scopus 로고
    • Detection of prostate specific antigen with nanomechanical resonators
    • Waggoner, P. S.; Varshney, M.; Craighead, H. G. Detection of Prostate Specific Antigen with Nanomechanical Resonators. Lab Chip 2009, 9, 3095-3099.
    • (2009) Lab Chip , vol.9 , pp. 3095-3099
    • Waggoner, P.S.1    Varshney, M.2    Craighead, H.G.3
  • 7
    • 77749324138 scopus 로고    scopus 로고
    • Label-free biomarker sensing in undiluted serum with suspended microchannel resonators
    • von Muhlen, M. G.; Brault, N. D.; Knudsen, S. M.; Jiang, S. Y.; Manalis, S. R. Label-Free Biomarker Sensing in Undiluted Serum with Suspended Microchannel Resonators. Anal. Chem. 2010, 82, 1905-1910.
    • (2010) Anal. Chem. , vol.82 , pp. 1905-1910
    • Von Muhlen, M.G.1    Brault, N.D.2    Knudsen, S.M.3    Jiang, S.Y.4    Manalis, S.R.5
  • 10
    • 79955821190 scopus 로고    scopus 로고
    • Comparative advantages of mechanical biosensors
    • Arlett, J. L.; Myers, E. B.; Roukes, M. L. Comparative Advantages of Mechanical Biosensors. Nat. Nanotechnol. 2011, 6, 203-215.
    • (2011) Nat. Nanotechnol. , vol.6 , pp. 203-215
    • Arlett, J.L.1    Myers, E.B.2    Roukes, M.L.3
  • 11
    • 80051489275 scopus 로고    scopus 로고
    • Cantilever array sensors detect specific carbohydrate-protein interactions with picomolar sensitivity
    • Gruber, K.; Horlacher, T.; Castelli, R.; Mader, A.; Seeberger, P. H.; Hermann, B. A. Cantilever Array Sensors Detect Specific Carbohydrate-Protein Interactions with Picomolar Sensitivity. ACS Nano 2011, 5, 3670-3678.
    • (2011) ACS Nano , vol.5 , pp. 3670-3678
    • Gruber, K.1    Horlacher, T.2    Castelli, R.3    Mader, A.4    Seeberger, P.H.5    Hermann, B.A.6
  • 13
    • 33846876588 scopus 로고    scopus 로고
    • Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-Frequency applications
    • Li, M.; Tang, H. X.; Roukes, M. L. Ultra-Sensitive NEMS-Based Cantilevers for Sensing, Scanned Probe and Very High-Frequency Applications. Nat. Nanotechnol. 2007, 2, 114-120.
    • (2007) Nat. Nanotechnol. , vol.2 , pp. 114-120
    • Li, M.1    Tang, H.X.2    Roukes, M.L.3
  • 14
    • 33645085279 scopus 로고    scopus 로고
    • MOSFET-embedded microcantilevers for measuring deflection in biomolecular sensors
    • Shekhawat, G.; Tark, S. H.; Dravid, V. P. MOSFET-Embedded Microcantilevers for Measuring Deflection in Biomolecular Sensors. Science 2006, 311, 1592-1595.
    • (2006) Science , vol.311 , pp. 1592-1595
    • Shekhawat, G.1    Tark, S.H.2    Dravid, V.P.3
  • 15
    • 34249093580 scopus 로고    scopus 로고
    • Characterization and optimization of gold nanoparticle-based silver-enhanced immunoassays
    • Gupta, S.; Huda, S.; Kilpatrick, P. K.; Velev, O. D. Characterization and Optimization of Gold Nanoparticle-Based Silver-Enhanced Immunoassays. Anal. Chem. 2007, 79, 3810-3820.
    • (2007) Anal. Chem. , vol.79 , pp. 3810-3820
    • Gupta, S.1    Huda, S.2    Kilpatrick, P.K.3    Velev, O.D.4
  • 16
    • 80053324168 scopus 로고    scopus 로고
    • A facile and sensitive immunoassay for the detection of alpha-fetoprotein using gold-coated Magnetic nanoparticle clusters and dynamic light scattering
    • Chun, C.; Joo, J.; Kwon, D.; Kim, C. S.; Cha, H. J.; Chung, M. S.; Jeon, S. A Facile and Sensitive Immunoassay for the Detection of Alpha-Fetoprotein Using Gold-Coated Magnetic Nanoparticle Clusters and Dynamic Light Scattering. Chem. Commun. 2011, 47, 11047-11049.
    • (2011) Chem. Commun. , vol.47 , pp. 11047-11049
    • Chun, C.1    Joo, J.2    Kwon, D.3    Kim, C.S.4    Cha, H.J.5    Chung, M.S.6    Jeon, S.7
  • 18
    • 74549176750 scopus 로고    scopus 로고
    • 2@PMMA core-shell-shell Magnetic microspheres for highly efficient enrichment of peptides and proteins for MALDI-ToF MS analysis
    • 2@PMMA Core-Shell-Shell Magnetic Microspheres for Highly Efficient Enrichment of Peptides and Proteins for MALDI-ToF MS Analysis. Angew. Chem., Int. Ed. 2010, 49, 607-611.
    • (2010) Angew. Chem., Int. Ed. , vol.49 , pp. 607-611
    • Chen, H.M.1    Deng, C.H.2    Zhang, X.M.3
  • 19
    • 77956478229 scopus 로고    scopus 로고
    • Magnetically recoverable core-shell nanocomposites with enhanced photocatalytic activity
    • Ye, M. M.; Zhang, Q.; Hu, Y. X.; Ge, J. P.; Lu, Z. D.; He, L.; Chen, Z. L.; Yin, Y. D. Magnetically Recoverable Core-Shell Nanocomposites with Enhanced Photocatalytic Activity. Chem.;Eur. J. 2010, 16, 6243-6250.
    • (2010) Chem.;Eur. J. , vol.16 , pp. 6243-6250
    • Ye, M.M.1    Zhang, Q.2    Hu, Y.X.3    Ge, J.P.4    Lu, Z.D.5    He, L.6    Chen, Z.L.7    Yin, Y.D.8
  • 20
    • 51349104221 scopus 로고    scopus 로고
    • Deposition of anatase titania onto carbon encapsulated magnetite nanoparticles
    • Ao, Y. H.; Xu, J. J.; Fu, D. G.; Ba, L.; Yuan, C. W. Deposition of Anatase Titania onto Carbon Encapsulated Magnetite Nanoparticles. Nanotechnology 2008, 19, 405604
    • (2008) Nanotechnology , vol.19 , pp. 405604
    • Ao, Y.H.1    Xu, J.J.2    Fu, D.G.3    Ba, L.4    Yuan, C.W.5
  • 21
    • 0034902310 scopus 로고    scopus 로고
    • Photocatalytic degradation of dyes on a magnetically separated photocatalyst under visible and UV irradiation
    • Chen, F.; Xie, Y. D.; Zhao, J. C.; Lu, G. X. Photocatalytic Degradation of Dyes on a Magnetically Separated Photocatalyst under Visible and UV Irradiation. Chemosphere 2001, 44, 1159-1168.
    • (2001) Chemosphere , vol.44 , pp. 1159-1168
    • Chen, F.1    Xie, Y.D.2    Zhao, J.C.3    Lu, G.X.4
  • 24
    • 77956470270 scopus 로고    scopus 로고
    • Self-assembly of superparamagnetic magnetite particles into peapod-like structures and their application in optical modulation
    • Ye, M. M.; Zorba, S.; He, L.; Hu, Y. X.; Maxwell, R. T.; Farah, C.; Zhang, Q.; Yin, Y. D. Self-Assembly of Superparamagnetic Magnetite Particles into Peapod-Like Structures and Their Application in Optical Modulation. J. Mater. Chem. 2010, 20, 7965-7969.
    • (2010) J. Mater. Chem. , vol.20 , pp. 7965-7969
    • Ye, M.M.1    Zorba, S.2    He, L.3    Hu, Y.X.4    Maxwell, R.T.5    Farah, C.6    Zhang, Q.7    Yin, Y.D.8
  • 26
    • 0034636562 scopus 로고    scopus 로고
    • Novel photocatalyst: Titania-coated magnetite. Activity and photodissolution
    • Beydoun, D.; Amal, R.; Low, G. K. C.; McEvoy, S. Novel Photocatalyst: Titania-Coated Magnetite. Activity and Photodissolution. J. Phys. Chem. B 2000, 104, 4387-4396.
    • (2000) J. Phys. Chem. B , vol.104 , pp. 4387-4396
    • Beydoun, D.1    Amal, R.2    Low, G.K.C.3    McEvoy, S.4
  • 28
    • 26644435999 scopus 로고    scopus 로고
    • Microcantilever biosensors
    • Hansen, K. M.; Thundat, T. Microcantilever Biosensors. Methods 2005, 37, 57-64.
    • (2005) Methods , vol.37 , pp. 57-64
    • Hansen, K.M.1    Thundat, T.2
  • 29
    • 77950376072 scopus 로고    scopus 로고
    • Enhanced photocatalytic activity of highly crystallized and ordered mesoporous titanium oxide measured by silicon resonators
    • Joo, J.; Shim, J.; Seo, H.; Jug, N.; Wiesner, U.; Lee, J.; Jeon, S. Enhanced Photocatalytic Activity of Highly Crystallized and Ordered Mesoporous Titanium Oxide Measured by Silicon Resonators. Anal. Chem. 2010, 82, 3032-3037.
    • (2010) Anal. Chem. , vol.82 , pp. 3032-3037
    • Joo, J.1    Shim, J.2    Seo, H.3    Jug, N.4    Wiesner, U.5    Lee, J.6    Jeon, S.7
  • 30
    • 59949096897 scopus 로고    scopus 로고
    • Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantilevers for early-stage diagnosis of heptocellular carcinoma
    • Liu, Y. J.; Li, X. X.; Zhang, Z. X.; Zuo, G. M.; Cheng, Z. X.; Yu, H. T. Nanogram per Milliliter-Level Immunologic Detection of Alpha-Fetoprotein with Integrated Rotating-Resonance Microcantilevers for Early-Stage Diagnosis of Heptocellular Carcinoma. Biomed. Microdevices 2009, 11, 183-191.
    • (2009) Biomed. Microdevices , vol.11 , pp. 183-191
    • Liu, Y.J.1    Li, X.X.2    Zhang, Z.X.3    Zuo, G.M.4    Cheng, Z.X.5    Yu, H.T.6
  • 31
    • 84855274255 scopus 로고    scopus 로고
    • Measurement of hepatitis b surface antigen concentrations using a piezoelectric microcantilever as a mass sensor
    • Lee, S.; Cho, J.; Lee, Y.; Jeon, S.; Cha, H. J.; Moon, W. K. Measurement of Hepatitis B Surface Antigen Concentrations Using a Piezoelectric Microcantilever as a Mass Sensor. J. Sens. 2012, 2012, 217958
    • (2012) J. Sens. , vol.2012 , pp. 217958
    • Lee, S.1    Cho, J.2    Lee, Y.3    Jeon, S.4    Cha, H.J.5    Moon, W.K.6
  • 32
    • 35348812686 scopus 로고    scopus 로고
    • Nanomechanical microcantilever operated in vibration modes with use of RNA aptamer as receptor molecules for label-free detection of HCV helicase
    • Hwang, K. S.; Lee, S. M.; Eom, K.; Lee, J. H.; Lee, Y. S.; Park, J. H.; Yoon, D. S.; Kim, T. S. Nanomechanical Microcantilever Operated in Vibration Modes with Use of RNA Aptamer as Receptor Molecules for Label-Free Detection of HCV Helicase. Biosens. Bioelectron. 2007, 23, 459-465.
    • (2007) Biosens. Bioelectron. , vol.23 , pp. 459-465
    • Hwang, K.S.1    Lee, S.M.2    Eom, K.3    Lee, J.H.4    Lee, Y.S.5    Park, J.H.6    Yoon, D.S.7    Kim, T.S.8
  • 33
    • 69549118192 scopus 로고    scopus 로고
    • Sensitivity enhancement of a dynamic mode microcantilever by stress inducer and mass inducer to detect PSA at low picogram levels
    • Lee, S. M.; Hwang, K. S.; Yoon, H. J.; Yoon, D. S.; Kim, S. K.; Lee, Y. S.; Kim, T. S. Sensitivity Enhancement of a Dynamic Mode Microcantilever by Stress Inducer and Mass Inducer to Detect PSA at Low Picogram Levels. Lab Chip 2009, 9, 2683-2690.
    • (2009) Lab Chip , vol.9 , pp. 2683-2690
    • Lee, S.M.1    Hwang, K.S.2    Yoon, H.J.3    Yoon, D.S.4    Kim, S.K.5    Lee, Y.S.6    Kim, T.S.7
  • 34
    • 70349882129 scopus 로고    scopus 로고
    • Prion protein detection in serum using micromechanical resonator arrays
    • Varshney, M.; Waggoner, P. S.; Montagna, R. A.; Craighead, H. G. Prion Protein Detection in Serum Using Micromechanical Resonator Arrays. Talanta 2009, 80, 593-599.
    • (2009) Talanta , vol.80 , pp. 593-599
    • Varshney, M.1    Waggoner, P.S.2    Montagna, R.A.3    Craighead, H.G.4
  • 35
    • 41449105725 scopus 로고    scopus 로고
    • Prion protein detection using nanomechanical resonator arrays and secondary mass labeling
    • Varshney, M.; Waggoner, P. S.; Tan, C. P.; Aubin, K.; Montagna, R. A.; Craighead, H. G. Prion Protein Detection Using Nanomechanical Resonator Arrays and Secondary Mass Labeling. Anal. Chem. 2008, 80, 2141-2148.
    • (2008) Anal. Chem. , vol.80 , pp. 2141-2148
    • Varshney, M.1    Waggoner, P.S.2    Tan, C.P.3    Aubin, K.4    Montagna, R.A.5    Craighead, H.G.6
  • 36
    • 0141929384 scopus 로고    scopus 로고
    • Controlling anisotropic nanoparticle growth through plasmon excitation
    • Jin, R. C.; Cao, Y. C.; Hao, E. C.; Metraux, G. S.; Schatz, G. C.; Mirkin, C. A. Controlling Anisotropic Nanoparticle Growth Through Plasmon Excitation. Nature 2003, 425, 487-490.
    • (2003) Nature , vol.425 , pp. 487-490
    • Jin, R.C.1    Cao, Y.C.2    Hao, E.C.3    Metraux, G.S.4    Schatz, G.C.5    Mirkin, C.A.6
  • 37
  • 39
    • 54349091866 scopus 로고    scopus 로고
    • Dye-doped silica nanoparticle labels/protein microarray for detection of protein biomarkers
    • Wu, H.; Huo, Q. S.; Varnum, S.; Wang, J.; Liu, G. G.; Nie, Z. M.; Liu, J.; Lin, Y. H. Dye-Doped Silica Nanoparticle Labels/Protein Microarray for Detection of Protein Biomarkers. Analyst 2008, 133, 1550-1555.
    • (2008) Analyst , vol.133 , pp. 1550-1555
    • Wu, H.1    Huo, Q.S.2    Varnum, S.3    Wang, J.4    Liu, G.G.5    Nie, Z.M.6    Liu, J.7    Lin, Y.H.8
  • 40
    • 33747214984 scopus 로고    scopus 로고
    • Interdigitated conductometric immunosensor for determination of interleukin-6 in humans based on dendrimer g4 and colloidal gold modified composite film
    • Liang, K. Z.; Mu, W. J.; Huang, M. Y.; Yu, Z. X.; Lai, Q. K. Interdigitated Conductometric Immunosensor for Determination of Interleukin-6 in Humans Based on Dendrimer G4 and Colloidal Gold Modified Composite Film. Electroanalysis 2006, 18, 1505-1510.
    • (2006) Electroanalysis , vol.18 , pp. 1505-1510
    • Liang, K.Z.1    Mu, W.J.2    Huang, M.Y.3    Yu, Z.X.4    Lai, Q.K.5
  • 41
    • 62649152759 scopus 로고    scopus 로고
    • Highly specific detection of interleukin-6 (IL-6) protein using combination tapered fiber-optic biosensor dip-probe
    • Kapoor, R.; Wang, C. W. Highly Specific Detection of Interleukin-6 (IL-6) Protein Using Combination Tapered Fiber-Optic Biosensor Dip-Probe. Biosens. Bioelectron. 2009, 24, 2696-2701.
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2696-2701
    • Kapoor, R.1    Wang, C.W.2
  • 42
    • 79952772894 scopus 로고    scopus 로고
    • Dual amplification strategy for the fabrication of highly sensitive interleukin-6 amperometric immunosensor based on poly-dopamine
    • Wang, G. F.; Huang, H.; Zhang, G.; Zhang, X. J.; Fang, B.; Wang, L Dual Amplification Strategy for the Fabrication of Highly Sensitive Interleukin-6 Amperometric Immunosensor Based on Poly-Dopamine. Langmuir 2011, 27, 1224-1231.
    • (2011) Langmuir , vol.27 , pp. 1224-1231
    • Wang, G.F.1    Huang, H.2    Zhang, G.3    Zhang, X.J.4    Fang, B.5    Wang, L.6
  • 44


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.