메뉴 건너뛰기




Volumn 83, Issue 4, 2012, Pages 1338-1343

Respiration-correlated image guidance is the most important radiotherapy motion management strategy for most lung cancer patients

Author keywords

4DCT; IGRT; Lung cancer; Motion management; Respiratory gating

Indexed keywords

4DCT; IGRT; LUNG CANCER; MOTION MANAGEMENT; RESPIRATORY GATINGS;

EID: 84862662151     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.09.010     Document Type: Article
Times cited : (51)

References (27)
  • 1
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 2000;474: 1121-1135.
    • (2000) Int J Radiat Oncol Biol Phys , vol.474 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3
  • 2
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • Korreman SS, Juhler-Nottrup T, Boyer AL. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. Radiother Oncol 2008;86(1): 61-68.
    • (2008) Radiother Oncol , vol.86 , Issue.1 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3
  • 3
    • 39749145316 scopus 로고    scopus 로고
    • Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients
    • Wolthaus JW, Sonke JJ, van Herk M, et al. Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 2008; 70(4):1229-1238.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.4 , pp. 1229-1238
    • Wolthaus, J.W.1    Sonke, J.J.2    Van Herk, M.3
  • 4
    • 65449175240 scopus 로고    scopus 로고
    • Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking
    • Sawant A, Smith RL, Venkat RB, et al. Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking. Int J Radiat Oncol Biol Phys 2009;74(2):575-582.
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , Issue.2 , pp. 575-582
    • Sawant, A.1    Smith, R.L.2    Venkat, R.B.3
  • 5
    • 67349247094 scopus 로고    scopus 로고
    • Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
    • Sonke JJ, Rossi M, Wolthaus J, et al. Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 2009;74(2):567-574.
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , Issue.2 , pp. 567-574
    • Sonke, J.J.1    Rossi, M.2    Wolthaus, J.3
  • 6
    • 33846239895 scopus 로고    scopus 로고
    • A dosimetric analysis of respiration-gated radiotherapy in patients with stage III lung cancer
    • doi:10.1186/1748-717X-1-8
    • Underberg RW, van Sornsen de Koste JR, Lagerwaard FJ, et al. A dosimetric analysis of respiration-gated radiotherapy in patients with stage III lung cancer. Radiat Oncol 2006;1-8. doi:10.1186/1748-717X-1-8.
    • (2006) Radiat Oncol , pp. 1-8
    • Underberg, R.W.1    Van Sornsen De Koste, J.R.2    Lagerwaard, F.J.3
  • 7
    • 41449087578 scopus 로고    scopus 로고
    • Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study
    • Nioutsikou E, Seppenwoolde Y, Symonds-Tayler JR, et al. Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: an experimental study. Med Phys 2008; 35(4):1232-1240.
    • (2008) Med Phys , vol.35 , Issue.4 , pp. 1232-1240
    • Nioutsikou, E.1    Seppenwoolde, Y.2    Symonds-Tayler, J.R.3
  • 8
    • 37549062637 scopus 로고    scopus 로고
    • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects
    • Seco J, Sharp GC, Wu Z, et al. Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects. Med Phys 2008;35(1): 356-366.
    • (2008) Med Phys , vol.35 , Issue.1 , pp. 356-366
    • Seco, J.1    Sharp, G.C.2    Wu, Z.3
  • 9
    • 25444446798 scopus 로고    scopus 로고
    • Breathing adapted radiotherapy for breast cancer: Comparison of free breathing gating with the breath-hold technique
    • Korreman SS, Pedersen AN, Nottrup TJ, et al. Breathing adapted radiotherapy for breast cancer: Comparison of free breathing gating with the breath-hold technique. Radiother Oncol 2005;76(3):311-318.
    • (2005) Radiother Oncol , vol.76 , Issue.3 , pp. 311-318
    • Korreman, S.S.1    Pedersen, A.N.2    Nottrup, T.J.3
  • 10
    • 0037606000 scopus 로고    scopus 로고
    • Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy
    • Remouchamps VM, Letts N, Vicini FA, et al. Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. Int J Radiat Oncol Biol Phys 2003;56(3):704-715.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.3 , pp. 704-715
    • Remouchamps, V.M.1    Letts, N.2    Vicini, F.A.3
  • 11
    • 26944441695 scopus 로고    scopus 로고
    • Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer
    • Underberg RW, Lagerwaard FJ, Slotman BJ, et al. Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 2005;63(1): 253-260.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , Issue.1 , pp. 253-260
    • Underberg, R.W.1    Lagerwaard, F.J.2    Slotman, B.J.3
  • 12
    • 0842306308 scopus 로고    scopus 로고
    • Errors and margins in radiotherapy
    • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 2004;14(1):52-64.
    • (2004) Semin Radiat Oncol , vol.14 , Issue.1 , pp. 52-64
    • Van Herk, M.1
  • 13
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006;33(10):3874-3900.
    • (2006) Med Phys , vol.33 , Issue.10 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3
  • 14
    • 79960077324 scopus 로고    scopus 로고
    • Artifacts in conventional computed tomography (CT) and free breathing four-dimensional CT induce uncertainty in gross tumor volume determination
    • Fredberg PG, Nygaard DE, af Rosenschold PM, et al. Artifacts in conventional computed tomography (CT) and free breathing four-dimensional CT induce uncertainty in gross tumor volume determination. Int J Radiat Oncol Biol Phys 2011;805:1573-1580.
    • (2011) Int J Radiat Oncol Biol Phys , vol.805 , pp. 1573-1580
    • Fredberg, P.G.1    Nygaard, D.E.2    Af Rosenschold, P.M.3
  • 15
    • 77953962041 scopus 로고    scopus 로고
    • Deviations in delineated GTV caused by artefacts in 4DCT
    • Persson GF, Nygaard DE, Brink C, et al. Deviations in delineated GTV caused by artefacts in 4DCT. Radiother Oncol 2010;96(1):61-66.
    • (2010) Radiother Oncol , vol.96 , Issue.1 , pp. 61-66
    • Persson, G.F.1    Nygaard, D.E.2    Brink, C.3
  • 16
    • 33847646451 scopus 로고    scopus 로고
    • Results of a phase I dose-escalation study using single-fraction stereotactic radiotherapy for lung tumors
    • Le QT, Loo BW, Ho A, et al. Results of a phase I dose-escalation study using single-fraction stereotactic radiotherapy for lung tumors. J Thorac Oncol 2006;1(8):802-809.
    • (2006) J Thorac Oncol , vol.1 , Issue.8 , pp. 802-809
    • Le, Q.T.1    Loo, B.W.2    Ho, A.3
  • 17
    • 33748865015 scopus 로고    scopus 로고
    • Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials
    • Korreman S, Mostafavi H, Le QT, et al. Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials. Acta Oncol 2006;45(7):935-942.
    • (2006) Acta Oncol , vol.45 , Issue.7 , pp. 935-942
    • Korreman, S.1    Mostafavi, H.2    Le, Q.T.3
  • 18
    • 0033824313 scopus 로고    scopus 로고
    • Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    • Shirato H, Shimizu S, Kitamura K, et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys 2000;48(2):435-442.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , Issue.2 , pp. 435-442
    • Shirato, H.1    Shimizu, S.2    Kitamura, K.3
  • 19
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • Sonke JJ, Lebesque J, van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys 2008;70(2):590-598.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.2 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    Van Herk, M.3
  • 20
    • 0345257799 scopus 로고    scopus 로고
    • Biologic and physical fractionation effects of random geometric errors
    • van Herk M, Witte M, van der GJ, et al. Biologic and physical fractionation effects of random geometric errors. Int J Radiat Oncol Biol Phys 2003;57(5):1460-1471.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , Issue.5 , pp. 1460-1471
    • Van Herk, M.1    Witte, M.2    Van Der, G.J.3
  • 21
    • 51849126550 scopus 로고    scopus 로고
    • A margin model to account for respiration-induced tumour motion and its variability
    • Coolens C, Webb S, Shirato H, et al. A margin model to account for respiration-induced tumour motion and its variability. Phys Med Biol 2008;53(16):4317-4330.
    • (2008) Phys Med Biol , vol.53 , Issue.16 , pp. 4317-4330
    • Coolens, C.1    Webb, S.2    Shirato, H.3
  • 22
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • Sonke JJ, Lebesque J, van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys 2008;70(2):590-598.
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.2 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    Van Herk, M.3
  • 23
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus JW, Schneider C, Sonke JJ, et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 2006;65(5):1560-1571.
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , Issue.5 , pp. 1560-1571
    • Wolthaus, J.W.1    Schneider, C.2    Sonke, J.J.3
  • 24
    • 36148932560 scopus 로고    scopus 로고
    • On-line target position localization in the presence of respiration: A comparison of two methods
    • Hugo GD, Liang J, Campbell J, et al. On-line target position localization in the presence of respiration: A comparison of two methods. Int J Radiat Oncol Biol Phys 2007;69(5):1634-1641.
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , Issue.5 , pp. 1634-1641
    • Hugo, G.D.1    Liang, J.2    Campbell, J.3
  • 25
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 2002;53(4):822-834.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , Issue.4 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 26
    • 65749109343 scopus 로고    scopus 로고
    • Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy
    • Guckenberger M, Krieger T, Richter A, et al. Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy. Radiother Oncol 2009; 91(3):288-295.
    • (2009) Radiother Oncol , vol.91 , Issue.3 , pp. 288-295
    • Guckenberger, M.1    Krieger, T.2    Richter, A.3
  • 27
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • Korreman SS, Juhler-Nottrup T, Boyer AL. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. Radiother Oncol 2008;86(1): 61-68.
    • (2008) Radiother Oncol , vol.86 , Issue.1 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.