메뉴 건너뛰기




Volumn 96, Issue 1, 2010, Pages 61-66

Deviations in delineated GTV caused by artefacts in 4DCT

Author keywords

4DCT; Artefacts; GTV; Lung cancer

Indexed keywords

ARTICLE; BREATHING; CANCER SIZE; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; ERROR; FOUR DIMENSIONAL COMPUTER ASSISTED TOMOGRAPHY; HUMAN; LUNG CANCER; PRIORITY JOURNAL; TREATMENT PLANNING; TUMOR VOLUME;

EID: 77953962041     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2010.04.019     Document Type: Article
Times cited : (85)

References (30)
  • 1
    • 0842327786 scopus 로고    scopus 로고
    • Artifacts in computed tomography scanning of moving objects
    • Chen G.T., Kung J.H., and Beaudette K.P. Artifacts in computed tomography scanning of moving objects. Semin Radiat Oncol 14 (2004) 19-26
    • (2004) Semin Radiat Oncol , vol.14 , pp. 19-26
    • Chen, G.T.1    Kung, J.H.2    Beaudette, K.P.3
  • 2
    • 0034654424 scopus 로고    scopus 로고
    • Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy
    • Shimizu S., Shirato H., Kagei K., et al. Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys 46 (2000) 1127-1133
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 1127-1133
    • Shimizu, S.1    Shirato, H.2    Kagei, K.3
  • 3
    • 17844371743 scopus 로고    scopus 로고
    • Four-dimensional computed tomography: image formation and clinical protocol
    • Rietzel E., Pan T., and Chen G.T. Four-dimensional computed tomography: image formation and clinical protocol. Med Phys 32 (2005) 874-889
    • (2005) Med Phys , vol.32 , pp. 874-889
    • Rietzel, E.1    Pan, T.2    Chen, G.T.3
  • 4
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning
    • Ford E.C., Mageras G.S., Yorke E., and Ling C.C. Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys 30 (2003) 88-97
    • (2003) Med Phys , vol.30 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3    Ling, C.C.4
  • 5
    • 70349783471 scopus 로고    scopus 로고
    • 4D CT sorting based on patient internal anatomy
    • Li R., Lewis J.H., Cervino L.I., and Jiang S.B. 4D CT sorting based on patient internal anatomy. Phys Med Biol 54 (2009) 4821-4833
    • (2009) Phys Med Biol , vol.54 , pp. 4821-4833
    • Li, R.1    Lewis, J.H.2    Cervino, L.I.3    Jiang, S.B.4
  • 6
    • 0037422708 scopus 로고    scopus 로고
    • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
    • Vedam S.S., Keall P.J., Kini V.R., et al. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 48 (2003) 45-62
    • (2003) Phys Med Biol , vol.48 , pp. 45-62
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3
  • 7
    • 0347625747 scopus 로고    scopus 로고
    • Validation of target volume and position in respiratory gated CT planning and treatment
    • Shen S., Duan J., Fiveash J.B., et al. Validation of target volume and position in respiratory gated CT planning and treatment. Med Phys 30 (2003) 3196-3205
    • (2003) Med Phys , vol.30 , pp. 3196-3205
    • Shen, S.1    Duan, J.2    Fiveash, J.B.3
  • 8
    • 34249751028 scopus 로고    scopus 로고
    • Phase and amplitude binning for 4D-CT imaging
    • Abdelnour A.F., Nehmeh S.A., Pan T., et al. Phase and amplitude binning for 4D-CT imaging. Phys Med Biol 52 (2007) 3515-3529
    • (2007) Phys Med Biol , vol.52 , pp. 3515-3529
    • Abdelnour, A.F.1    Nehmeh, S.A.2    Pan, T.3
  • 9
    • 33746625978 scopus 로고    scopus 로고
    • A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT
    • Lu W., Parikh P.J., Hubenschmidt J.P., Bradley J.D., and Low D.A. A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. Med Phys 33 (2006) 2964-2974
    • (2006) Med Phys , vol.33 , pp. 2964-2974
    • Lu, W.1    Parikh, P.J.2    Hubenschmidt, J.P.3    Bradley, J.D.4    Low, D.A.5
  • 10
    • 37049034266 scopus 로고    scopus 로고
    • Effect of novel amplitude/phase binning algorithm on commercial four-dimensional computed tomography quality
    • Olsen J.R., Lu W., Hubenschmidt J.P., et al. Effect of novel amplitude/phase binning algorithm on commercial four-dimensional computed tomography quality. Int J Radiat Oncol Biol Phys 70 (2008) 243-252
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 243-252
    • Olsen, J.R.1    Lu, W.2    Hubenschmidt, J.P.3
  • 11
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus J.W., Schneider C., Sonke J.J., et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 65 (2006) 1560-1571
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1560-1571
    • Wolthaus, J.W.1    Schneider, C.2    Sonke, J.J.3
  • 12
    • 7444226933 scopus 로고    scopus 로고
    • Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer
    • Underberg R.W., Lagerwaard F.J., Cuijpers J.P., et al. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. Int J Radiat Oncol Biol Phys 60 (2004) 1283-1290
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1283-1290
    • Underberg, R.W.1    Lagerwaard, F.J.2    Cuijpers, J.P.3
  • 14
    • 33646263112 scopus 로고    scopus 로고
    • The clinical implementation of respiratory-gated intensity-modulated radiotherapy
    • Keall P., Vedam S., George R., et al. The clinical implementation of respiratory-gated intensity-modulated radiotherapy. Med Dosim 31 (2006) 152-162
    • (2006) Med Dosim , vol.31 , pp. 152-162
    • Keall, P.1    Vedam, S.2    George, R.3
  • 15
    • 4544283239 scopus 로고    scopus 로고
    • Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques
    • Berson A.M., Emery R., Rodriguez L., et al. Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques. Int J Radiat Oncol Biol Phys 60 (2004) 419-426
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 419-426
    • Berson, A.M.1    Emery, R.2    Rodriguez, L.3
  • 16
    • 33646927016 scopus 로고    scopus 로고
    • Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy
    • George R., Chung T.D., Vedam S.S., et al. Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys 65 (2006) 924-933
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 924-933
    • George, R.1    Chung, T.D.2    Vedam, S.S.3
  • 17
    • 51049088404 scopus 로고    scopus 로고
    • Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC
    • Jensen H.R., Hansen O., Hjelm-Hansen M., and Brink C. Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC. Acta Oncol 47 (2008) 1432-1437
    • (2008) Acta Oncol , vol.47 , pp. 1432-1437
    • Jensen, H.R.1    Hansen, O.2    Hjelm-Hansen, M.3    Brink, C.4
  • 18
    • 17144425761 scopus 로고    scopus 로고
    • Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans
    • Wolthaus J.W., van H.M., Muller S.H., et al. Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans. Phys Med Biol 50 (2005) 1569-1583
    • (2005) Phys Med Biol , vol.50 , pp. 1569-1583
    • Wolthaus, J.W.1    van, H.M.2    Muller, S.H.3
  • 19
    • 36349025791 scopus 로고    scopus 로고
    • Four-dimensional multislice helical CT of the lung: qualitative comparison of retrospectively gated and static images in an ex-vivo system
    • Dinkel J., Welzel T., Bolte H., et al. Four-dimensional multislice helical CT of the lung: qualitative comparison of retrospectively gated and static images in an ex-vivo system. Radiother Oncol 85 (2007) 215-222
    • (2007) Radiother Oncol , vol.85 , pp. 215-222
    • Dinkel, J.1    Welzel, T.2    Bolte, H.3
  • 20
    • 51049088186 scopus 로고    scopus 로고
    • Can audio coached 4D CT emulate free breathing during the treatment course?
    • Persson G.F., Nygaard D.E., Olsen M., et al. Can audio coached 4D CT emulate free breathing during the treatment course?. Acta Oncol 47 (2008) 1397-1405
    • (2008) Acta Oncol , vol.47 , pp. 1397-1405
    • Persson, G.F.1    Nygaard, D.E.2    Olsen, M.3
  • 21
    • 34447100119 scopus 로고    scopus 로고
    • Intra- and interfraction breathing variations during curative radiotherapy for lung cancer
    • Juhler N.T., Korreman S.S., Pedersen A.N., et al. Intra- and interfraction breathing variations during curative radiotherapy for lung cancer. Radiother Oncol 84 (2007) 40-48
    • (2007) Radiother Oncol , vol.84 , pp. 40-48
    • Juhler, N.T.1    Korreman, S.S.2    Pedersen, A.N.3
  • 23
    • 68649101444 scopus 로고    scopus 로고
    • Do tumors in the lung deform during normal respiration? An image registration investigation
    • Wu J., Lei P., Shekhar R., et al. Do tumors in the lung deform during normal respiration? An image registration investigation. Int J Radiat Oncol Biol Phys 75 (2009) 268-275
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 268-275
    • Wu, J.1    Lei, P.2    Shekhar, R.3
  • 24
    • 65449175657 scopus 로고    scopus 로고
    • Impact of motion velocity on four-dimensional target volumes: a phantom study
    • Nakamura M., Narita Y., Sawada A., et al. Impact of motion velocity on four-dimensional target volumes: a phantom study. Med Phys 36 (2009) 1610-1617
    • (2009) Med Phys , vol.36 , pp. 1610-1617
    • Nakamura, M.1    Narita, Y.2    Sawada, A.3
  • 25
    • 54049105620 scopus 로고    scopus 로고
    • Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients
    • Yamamoto T., Langner U., Loo Jr. B.W., Shen J., and Keall P.J. Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys 72 (2008) 1250-1258
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 1250-1258
    • Yamamoto, T.1    Langner, U.2    Loo Jr., B.W.3    Shen, J.4    Keall, P.J.5
  • 27
    • 50449092728 scopus 로고    scopus 로고
    • Geometrical differences in target volumes between slow CT and 4D CT imaging in stereotactic body radiotherapy for lung tumors in the upper and middle lobe
    • Nakamura M., Narita Y., Matsuo Y., et al. Geometrical differences in target volumes between slow CT and 4D CT imaging in stereotactic body radiotherapy for lung tumors in the upper and middle lobe. Med Phys 35 (2008) 4142-4148
    • (2008) Med Phys , vol.35 , pp. 4142-4148
    • Nakamura, M.1    Narita, Y.2    Matsuo, Y.3
  • 28
    • 59649083454 scopus 로고    scopus 로고
    • 4D-Imaging of the lung: reproducibility of lesion size and displacement on helical CT, MRI, and cone beam CT in a ventilated ex vivo system
    • Biederer J., Dinkel J., Remmert G., et al. 4D-Imaging of the lung: reproducibility of lesion size and displacement on helical CT, MRI, and cone beam CT in a ventilated ex vivo system. Int J Radiat Oncol Biol Phys 73 (2009) 919-926
    • (2009) Int J Radiat Oncol Biol Phys , vol.73 , pp. 919-926
    • Biederer, J.1    Dinkel, J.2    Remmert, G.3
  • 29
    • 52949140550 scopus 로고    scopus 로고
    • Prospective displacement and velocity-based cine 4D CT
    • Langner U.W., and Keall P.J. Prospective displacement and velocity-based cine 4D CT. Med Phys 35 (2008) 4501-4512
    • (2008) Med Phys , vol.35 , pp. 4501-4512
    • Langner, U.W.1    Keall, P.J.2
  • 30
    • 36448988289 scopus 로고    scopus 로고
    • Influence of retrospective sorting on image quality in respiratory correlated computed tomography
    • Guckenberger M., Weininger M., Wilbert J., et al. Influence of retrospective sorting on image quality in respiratory correlated computed tomography. Radiother Oncol 85 (2007) 223-231
    • (2007) Radiother Oncol , vol.85 , pp. 223-231
    • Guckenberger, M.1    Weininger, M.2    Wilbert, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.