메뉴 건너뛰기




Volumn 74, Issue 2, 2009, Pages 567-574

Frameless Stereotactic Body Radiotherapy for Lung Cancer Using Four-Dimensional Cone Beam CT Guidance

Author keywords

Four dimensional cone beam CT (4D CBCT); Geometrical uncertainties; Image guided radiotherapy (IGRT); Margins; Stereotactic body radiotherapy (SBRT)

Indexed keywords

FOUR-DIMENSIONAL CONE BEAM CT (4D-CBCT); GEOMETRICAL UNCERTAINTIES; IMAGE-GUIDED RADIOTHERAPY (IGRT); MARGINS; STEREOTACTIC BODY RADIOTHERAPY (SBRT);

EID: 67349247094     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2008.08.004     Document Type: Article
Times cited : (233)

References (29)
  • 1
    • 27144516385 scopus 로고    scopus 로고
    • Dose-response in stereotactic IR radiation of lung tumors
    • Wulf J., Baier K., Mueller G., et al. Dose-response in stereotactic IR radiation of lung tumors. Radiother Oncol 77 (2005) 83-87
    • (2005) Radiother Oncol , vol.77 , pp. 83-87
    • Wulf, J.1    Baier, K.2    Mueller, G.3
  • 2
    • 33947498981 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy in multiple organ sites
    • Timmerman R.D., Kavanagh B.D., Cho L.C., et al. Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol 25 (2007) 947-952
    • (2007) J Clin Oncol , vol.25 , pp. 947-952
    • Timmerman, R.D.1    Kavanagh, B.D.2    Cho, L.C.3
  • 3
    • 39049164591 scopus 로고    scopus 로고
    • Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer
    • Lagerwaard F.J., Haasbeek C.J., Smit E.F., et al. Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 70 (2008) 685-692
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 685-692
    • Lagerwaard, F.J.1    Haasbeek, C.J.2    Smit, E.F.3
  • 4
    • 0034332698 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereo-tactic body frame
    • Wulf J., Hadinger U., Oppitz U., et al. Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereo-tactic body frame. Radiother Oncol 57 (2000) 225-236
    • (2000) Radiother Oncol , vol.57 , pp. 225-236
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3
  • 5
    • 18344370445 scopus 로고    scopus 로고
    • Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame
    • Nagata Y., Negoro Y., Aoki T., et al. Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. Int J Radiat Oncol Biol Phys 52 (2002) 1041-1046
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1041-1046
    • Nagata, Y.1    Negoro, Y.2    Aoki, T.3
  • 6
    • 26644455690 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome
    • Shioyama Y., Nakamura K., Anai S., et al. Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome. Radiat Med 23 (2005) 407-413
    • (2005) Radiat Med , vol.23 , pp. 407-413
    • Shioyama, Y.1    Nakamura, K.2    Anai, S.3
  • 7
    • 0033831790 scopus 로고    scopus 로고
    • Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (focal) unit
    • Uematsu M., Shioda A., Suda A., et al. Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (focal) unit. Int J Radiat Oncol Biol Phys 48 (2000) 443-448
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 443-448
    • Uematsu, M.1    Shioda, A.2    Suda, A.3
  • 8
    • 0033577447 scopus 로고    scopus 로고
    • Real-time tumour-tracking radio-therapy
    • Shirato H., Shimizu S., Shimizu T., et al. Real-time tumour-tracking radio-therapy. Lancet 353 (1999) 1331-1332
    • (1999) Lancet , vol.353 , pp. 1331-1332
    • Shirato, H.1    Shimizu, S.2    Shimizu, T.3
  • 10
    • 33749247062 scopus 로고    scopus 로고
    • Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system
    • Gibbs I.C. Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system. Cancer Radiother 10 (2006) 283-287
    • (2006) Cancer Radiother , vol.10 , pp. 283-287
    • Gibbs, I.C.1
  • 11
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • Jaffray D.A., Siewerdsen J.H., Wong J.W., et al. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53 (2002) 1337-1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 12
    • 17844379967 scopus 로고    scopus 로고
    • Respiration correlated cone beam CT
    • Sonke J.-J., Zijp L., Remeijer P., et al. Respiration correlated cone beam CT. Med Phys 32 (2005) 1176-1186
    • (2005) Med Phys , vol.32 , pp. 1176-1186
    • Sonke, J.-J.1    Zijp, L.2    Remeijer, P.3
  • 13
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus J.W., Schneider C., Sonke J.-J., et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 65 (2006) 1560-1571
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1560-1571
    • Wolthaus, J.W.1    Schneider, C.2    Sonke, J.-J.3
  • 14
    • 67349201517 scopus 로고    scopus 로고
    • The necessity of a correct dose calculation algorithm for stereotactic lung irradiation
    • Belderbos J., Lakeman A., Sonke J.-J., et al. The necessity of a correct dose calculation algorithm for stereotactic lung irradiation. J Thorac Oncol 2 Suppl. 4 (2007) S752
    • (2007) J Thorac Oncol , vol.2 , Issue.SUPPL. 4
    • Belderbos, J.1    Lakeman, A.2    Sonke, J.-J.3
  • 16
    • 27944454309 scopus 로고    scopus 로고
    • Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: A "big brother" evaluation
    • Steenbakkers R.J., Duppen J.C., Fitton I., et al. Observer variation in target volume delineation of lung cancer related to radiation oncologist-computer interaction: A "big brother" evaluation. Radiother Oncol 77 (2005) 182-190
    • (2005) Radiother Oncol , vol.77 , pp. 182-190
    • Steenbakkers, R.J.1    Duppen, J.C.2    Fitton, I.3
  • 17
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M., Remeijer P., Rasch C., et al. The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 47 (2000) 1121-1135
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3
  • 18
    • 9244219608 scopus 로고    scopus 로고
    • The effects of target size and tissue density on the minimum margin required for random errors
    • Witte M.G., van der Geer J., Schneider C., et al. The effects of target size and tissue density on the minimum margin required for random errors. Med Phys 31 (2004) 3068-3079
    • (2004) Med Phys , vol.31 , pp. 3068-3079
    • Witte, M.G.1    van der Geer, J.2    Schneider, C.3
  • 19
    • 0032941481 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculations
    • Lujan A.E., Larsen E.W., and Haken J.M.B.R.K.T. A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys 26 (1999) 715-720
    • (1999) Med Phys , vol.26 , pp. 715-720
    • Lujan, A.E.1    Larsen, E.W.2    Haken, J.M.B.R.K.T.3
  • 20
    • 39749088405 scopus 로고    scopus 로고
    • Defining the PTV and PRV-new ideas about old problems
    • [abstract]
    • McKenzie A. Defining the PTV and PRV-new ideas about old problems. [abstract]. Radiother Oncol 73 Suppl. 1 (2004) S203
    • (2004) Radiother Oncol , vol.73 , Issue.SUPPL. 1
    • McKenzie, A.1
  • 21
    • 33749634458 scopus 로고    scopus 로고
    • Simulation of the combined effect of delineation variation, setup error and organ motion
    • [abstract]
    • Deurloo K.E.E., Steenbakkers R.J.H.M., Nowak P.H.C.M., et al. Simulation of the combined effect of delineation variation, setup error and organ motion. [abstract]. Radiother Oncol 64 Suppl. 1 (2002) S115
    • (2002) Radiother Oncol , vol.64 , Issue.SUPPL. 1
    • Deurloo, K.E.E.1    Steenbakkers, R.J.H.M.2    Nowak, P.H.C.M.3
  • 22
    • 38149009727 scopus 로고    scopus 로고
    • Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging
    • Hoogeman M.S., Nuyttens J.J., Levendag P.C., et al. Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging. Int J Radiat Oncol Biol Phys 70 (2008) 609-618
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 609-618
    • Hoogeman, M.S.1    Nuyttens, J.J.2    Levendag, P.C.3
  • 23
    • 34247117297 scopus 로고    scopus 로고
    • Cone-beam computed tomography for on-line image guidance of lung stereotactic radio-therapy: Localization, verification, and intrafraction tumor position
    • Purdie T.G., Bissonnette J.P., Franks K., et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radio-therapy: Localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68 (2007) 243-252
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 243-252
    • Purdie, T.G.1    Bissonnette, J.P.2    Franks, K.3
  • 24
    • 33748875872 scopus 로고    scopus 로고
    • Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    • Guckenberger M., Meyer J., Wilbert J., et al. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol 45 (2006) 897-906
    • (2006) Acta Oncol , vol.45 , pp. 897-906
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 25
    • 39749185557 scopus 로고    scopus 로고
    • Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
    • Grills I.S., Hugo G., Kestin L.L., et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys 70 (2008) 1045-1056
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1045-1056
    • Grills, I.S.1    Hugo, G.2    Kestin, L.L.3
  • 26
    • 34247892507 scopus 로고    scopus 로고
    • Kilo-voltage cone beam CT setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device
    • Borst G.R., Sonke J.-J., Betgen A., et al. Kilo-voltage cone beam CT setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys 68 (2007) 555-561
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 555-561
    • Borst, G.R.1    Sonke, J.-J.2    Betgen, A.3
  • 27
    • 34047145827 scopus 로고    scopus 로고
    • Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    • Guckenberger M., Meyer J., Wilbert J., et al. Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol 83 (2007) 57-64
    • (2007) Radiother Oncol , vol.83 , pp. 57-64
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3
  • 28
    • 39749145316 scopus 로고    scopus 로고
    • Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients
    • Wolthaus J.W., Sonke J.-J., van Herk M., et al. Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 70 (2008) 1229-1238
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1229-1238
    • Wolthaus, J.W.1    Sonke, J.-J.2    van Herk, M.3
  • 29
    • 34548836679 scopus 로고    scopus 로고
    • Effects of respiration-induced anatomy variations on dose distributions
    • [abstract]
    • Mexner V., Wolthaus J.W., Nijkamp J., et al. Effects of respiration-induced anatomy variations on dose distributions. [abstract]. Radiother Oncol 84 Suppl. 1 (2007) S75
    • (2007) Radiother Oncol , vol.84 , Issue.SUPPL. 1
    • Mexner, V.1    Wolthaus, J.W.2    Nijkamp, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.