메뉴 건너뛰기




Volumn 74, Issue 2, 2009, Pages 575-582

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Author keywords

Adaptive radiotherapy; Intrafraction; Motion management; Tracking

Indexed keywords

ADAPTIVE RADIATIONS; ADAPTIVE RADIOTHERAPY; DELIVERY SYSTEMS; DOSE DELIVERIES; DYNAMIC MULTILEAF COLLIMATORS; GEOMETRIC ACCURACIES; INDUSTRIAL COLLABORATIONS; INTEGRATED SYSTEMS; INTENSITY-MODULATED RADIOTHERAPIES; INTRAFRACTION; INTRAFRACTION MOTIONS; LUNG TUMORS; MEGAVOLTAGE; MOTION MANAGEMENT; MOTION PREDICTIONS; MULTI-LEAF COLLIMATORS; NON-IONIZING RADIATIONS; POSITION MONITORING; POSITION MONITORING SYSTEMS; POSITIONAL ERRORS; REAL TIME; RESPIRATORY MOTIONS; ROOT MEAN SQUARES; SUB MILLIMETERS; SYSTEM LATENCIES; TARGET MOTIONS; THREE-DIMENSIONAL MOTIONS; TRACKING; TRACKING ACCURACIES; TRACKING SYSTEMS; X-RAY IMAGES;

EID: 65449175240     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2008.12.057     Document Type: Article
Times cited : (99)

References (42)
  • 1
    • 0036603793 scopus 로고    scopus 로고
    • Intrafraction prostate motion during IMRT for prostate cancer
    • Huang E., Dong L., Chandra A., et al. Intrafraction prostate motion during IMRT for prostate cancer. Int J Radiat Oncol Biol Phys 53 (2002) 261-268
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 261-268
    • Huang, E.1    Dong, L.2    Chandra, A.3
  • 2
    • 0345381992 scopus 로고    scopus 로고
    • Quantifying the effect of intrafraction motion during breast IMRT planning and dose delivery
    • George R., Keall P.J., Kini V.R., et al. Quantifying the effect of intrafraction motion during breast IMRT planning and dose delivery. Med Phys 30 (2003) 552-562
    • (2003) Med Phys , vol.30 , pp. 552-562
    • George, R.1    Keall, P.J.2    Kini, V.R.3
  • 3
    • 42949167404 scopus 로고    scopus 로고
    • An evaluation of intrafraction motion-induced error for fractionated IMRT delivery
    • 1470-1470
    • Hugo G., Tenn S., and Agazaryan N. An evaluation of intrafraction motion-induced error for fractionated IMRT delivery. Med Phys 30 (2003) 1470-1470
    • (2003) Med Phys , vol.30
    • Hugo, G.1    Tenn, S.2    Agazaryan, N.3
  • 4
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall P.J., Mageras G.S., Balter J.M., et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33 (2006) 3874-3900
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3
  • 5
    • 42949109604 scopus 로고    scopus 로고
    • Management of three-dimensional intrafraction motion through real-time DMLC tracking
    • Sawant A., Venkat R., Srivastava V., et al. Management of three-dimensional intrafraction motion through real-time DMLC tracking. Med Phys 35 (2008) 2050-2061
    • (2008) Med Phys , vol.35 , pp. 2050-2061
    • Sawant, A.1    Venkat, R.2    Srivastava, V.3
  • 6
    • 56749164944 scopus 로고    scopus 로고
    • DMLC motion tracking of moving targets for intensity modulated arc therapy treatment-A feasibility study
    • Zimmerman J., Korreman S., Persson G., et al. DMLC motion tracking of moving targets for intensity modulated arc therapy treatment-A feasibility study. Acta Oncol (2008) 1-6
    • (2008) Acta Oncol , pp. 1-6
    • Zimmerman, J.1    Korreman, S.2    Persson, G.3
  • 7
    • 33846245486 scopus 로고    scopus 로고
    • Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT
    • Beddar A.S., Kainz K., Briere T.M., et al. Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT. Int J Radiat Oncol Biol Phys 67 (2007) 630-638
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 630-638
    • Beddar, A.S.1    Kainz, K.2    Briere, T.M.3
  • 8
    • 16344373639 scopus 로고    scopus 로고
    • The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating
    • Gierga D.P., Brewer J., Sharp G.C., et al. The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating. Int J Radiat Oncol Biol Phys 61 (2005) 1551-1558
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1551-1558
    • Gierga, D.P.1    Brewer, J.2    Sharp, G.C.3
  • 9
    • 33750565186 scopus 로고    scopus 로고
    • The correlation evaluation of a tumor tracking system using multiple external markers
    • Yan H., Yin F.F., Zhu G.P., et al. The correlation evaluation of a tumor tracking system using multiple external markers. Med Phys 33 (2006) 4073-4084
    • (2006) Med Phys , vol.33 , pp. 4073-4084
    • Yan, H.1    Yin, F.F.2    Zhu, G.P.3
  • 10
    • 33748923308 scopus 로고    scopus 로고
    • Radiotherapy of mobile tumors
    • Jiang S.B. Radiotherapy of mobile tumors. Semin Radiat Oncol 16 (2006) 239-248
    • (2006) Semin Radiat Oncol , vol.16 , pp. 239-248
    • Jiang, S.B.1
  • 11
    • 0036223115 scopus 로고    scopus 로고
    • Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    • Kitamura K., Shirato H., Shimizu S., et al. Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT). Radiother Oncol 62 (2002) 275-281
    • (2002) Radiother Oncol , vol.62 , pp. 275-281
    • Kitamura, K.1    Shirato, H.2    Shimizu, S.3
  • 12
    • 0345269966 scopus 로고    scopus 로고
    • Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy
    • Shirato H., Harada T., Harabayashi T., et al. Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys 56 (2003) 240-247
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 240-247
    • Shirato, H.1    Harada, T.2    Harabayashi, T.3
  • 13
    • 4444313627 scopus 로고    scopus 로고
    • Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy
    • Shirato H., Oita M., Fujita K., et al. Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy. Int J Radiat Oncol Biol Phys 60 (2004) 335-341
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 335-341
    • Shirato, H.1    Oita, M.2    Fujita, K.3
  • 14
    • 34748915143 scopus 로고    scopus 로고
    • The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75
    • Murphy M.J., Balter J., Balter S., et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75. Med Phys 34 (2007) 4041-4063
    • (2007) Med Phys , vol.34 , pp. 4041-4063
    • Murphy, M.J.1    Balter, J.2    Balter, S.3
  • 15
  • 16
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer
    • Willoughby T.R., Kupelian P.A., Pouliot J., et al. Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys 65 (2006) 528-534
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 528-534
    • Willoughby, T.R.1    Kupelian, P.A.2    Pouliot, J.3
  • 17
    • 34347390456 scopus 로고    scopus 로고
    • Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study
    • Seppenwoolde Y., Berbeco R.I., Nishioka S., et al. Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study. Med Phys 34 (2007) 2774-2784
    • (2007) Med Phys , vol.34 , pp. 2774-2784
    • Seppenwoolde, Y.1    Berbeco, R.I.2    Nishioka, S.3
  • 18
    • 65449142560 scopus 로고    scopus 로고
    • Use of the 4D phantom to test real-time targeted radiation therapy device accuracy
    • 2611-2611
    • Malinowski K., Lechleiter K., Hubenschmidt J., et al. Use of the 4D phantom to test real-time targeted radiation therapy device accuracy. Med Phys 34 (2007) 2611-2611
    • (2007) Med Phys , vol.34
    • Malinowski, K.1    Lechleiter, K.2    Hubenschmidt, J.3
  • 19
    • 42949151038 scopus 로고    scopus 로고
    • Accurate prediction of intra-fraction motion using a modified linear adaptive filter
    • Srivastava V., Keall P.J., Sawant A., et al. Accurate prediction of intra-fraction motion using a modified linear adaptive filter. Med Phys 34 (2007) 2546
    • (2007) Med Phys , vol.34 , pp. 2546
    • Srivastava, V.1    Keall, P.J.2    Sawant, A.3
  • 20
    • 0035479329 scopus 로고    scopus 로고
    • Detection of lung tumor movement in real-time tumor-tracking radiotherapy
    • Shimizu S., Shirato H., Ogura S., et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys 51 (2001) 304-310
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 304-310
    • Shimizu, S.1    Shirato, H.2    Ogura, S.3
  • 21
    • 47649126554 scopus 로고    scopus 로고
    • An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients
    • Suh Y., Dieterich S., Cho B., et al. An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients. Phys Med Biol 53 (2008) 3623-3640
    • (2008) Phys Med Biol , vol.53 , pp. 3623-3640
    • Suh, Y.1    Dieterich, S.2    Cho, B.3
  • 22
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • Kupelian P., Willoughby T., Mahadevan A., et al. Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. Int J Radiat Oncol Biol Phys 67 (2007) 1088-1098
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1088-1098
    • Kupelian, P.1    Willoughby, T.2    Mahadevan, A.3
  • 23
    • 33846853755 scopus 로고    scopus 로고
    • Comparative performance of linear and nonlinear neural networks to predict irregular breathing
    • Murphy M.J., and Dieterich S. Comparative performance of linear and nonlinear neural networks to predict irregular breathing. Phys Med Biol 51 (2006) 5903-5914
    • (2006) Phys Med Biol , vol.51 , pp. 5903-5914
    • Murphy, M.J.1    Dieterich, S.2
  • 24
    • 34249715249 scopus 로고    scopus 로고
    • Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method
    • McCall K.C., and Jeraj R. Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method. Phys Med Biol 52 (2007) 3455-3466
    • (2007) Phys Med Biol , vol.52 , pp. 3455-3466
    • McCall, K.C.1    Jeraj, R.2
  • 25
    • 36349027625 scopus 로고    scopus 로고
    • Real-time prediction of respiratory motion based on local regression methods
    • Ruan D., Fessler J.A., and Balter J.M. Real-time prediction of respiratory motion based on local regression methods. Phys Med Biol 52 (2007) 7137-7152
    • (2007) Phys Med Biol , vol.52 , pp. 7137-7152
    • Ruan, D.1    Fessler, J.A.2    Balter, J.M.3
  • 26
    • 17844379267 scopus 로고    scopus 로고
    • Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy
    • Wijesooriya K., Bartee C., Siebers J.V., et al. Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: Implications for 4D radiotherapy. Med Phys 32 (2005) 932-941
    • (2005) Med Phys , vol.32 , pp. 932-941
    • Wijesooriya, K.1    Bartee, C.2    Siebers, J.V.3
  • 27
    • 0037384019 scopus 로고    scopus 로고
    • Stereotactic radiosurgery for lung tumors: Preliminary report of a phase I trial
    • Whyte R.I., Crownover R., Murphy M.J., et al. Stereotactic radiosurgery for lung tumors: Preliminary report of a phase I trial. Ann Thorac Surg 75 (2003) 1097-1101
    • (2003) Ann Thorac Surg , vol.75 , pp. 1097-1101
    • Whyte, R.I.1    Crownover, R.2    Murphy, M.J.3
  • 28
    • 33847646451 scopus 로고    scopus 로고
    • Results of a phase I dose-escalation study using single-fraction stereotactic radiotherapy for lung tumors
    • Le Q.T., Loo B.W., Ho A., et al. Results of a phase I dose-escalation study using single-fraction stereotactic radiotherapy for lung tumors. J Thorac Oncol 1 (2006) 802-809
    • (2006) J Thorac Oncol , vol.1 , pp. 802-809
    • Le, Q.T.1    Loo, B.W.2    Ho, A.3
  • 29
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., Kitamura K., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53 (2002) 822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2    Kitamura, K.3
  • 30
    • 0034333029 scopus 로고    scopus 로고
    • Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    • Shirato H., Shimizu S., Kunieda T., et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys 48 (2000) 1187-1195
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1187-1195
    • Shirato, H.1    Shimizu, S.2    Kunieda, T.3
  • 31
    • 34548674931 scopus 로고    scopus 로고
    • Implantation and stability of metallic fiducials within pulmonary lesions
    • Kupelian P.A., Forbes A., Willoughby T.R., et al. Implantation and stability of metallic fiducials within pulmonary lesions. Int J Radiat Oncol Biol Phys 69 (2007) 777-785
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 777-785
    • Kupelian, P.A.1    Forbes, A.2    Willoughby, T.R.3
  • 32
    • 38149030230 scopus 로고    scopus 로고
    • Histopathologic consideration of fiducial gold markers inserted for real-time tumor-tracking radiotherapy against lung cancer
    • Imura M., Yamazaki K., Kubota K.C., et al. Histopathologic consideration of fiducial gold markers inserted for real-time tumor-tracking radiotherapy against lung cancer. Int J Radiat Oncol Biol Phys 70 (2008) 382-384
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 382-384
    • Imura, M.1    Yamazaki, K.2    Kubota, K.C.3
  • 33
    • 49549101815 scopus 로고    scopus 로고
    • Bronchoscopic implantation of a novel wireless electromagnetic transponder in the canine lung: A feasibility study
    • Mayse M.L., Parikh P.J., Lechleiter K.M., et al. Bronchoscopic implantation of a novel wireless electromagnetic transponder in the canine lung: A feasibility study. Int J Radiat Oncol Biol Phys (2008)
    • (2008) Int J Radiat Oncol Biol Phys
    • Mayse, M.L.1    Parikh, P.J.2    Lechleiter, K.M.3
  • 34
    • 65449128567 scopus 로고    scopus 로고
    • Development of a non-migrating electromagnetic transponder system for lung tumor tracking
    • S430-S430
    • Mayse M.L., Smith R.L., Park M., et al. Development of a non-migrating electromagnetic transponder system for lung tumor tracking. Int J Radiat Oncol Biol Phys 72 (2008) S430-S430
    • (2008) Int J Radiat Oncol Biol Phys , vol.72
    • Mayse, M.L.1    Smith, R.L.2    Park, M.3
  • 35
    • 34447256580 scopus 로고    scopus 로고
    • Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking
    • Litzenberg D.W., Willoughby T.R., Balter J.M., et al. Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking. Int J Radiat Oncol Biol Phys 68 (2007) 1199-1206
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 1199-1206
    • Litzenberg, D.W.1    Willoughby, T.R.2    Balter, J.M.3
  • 37
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • Papiez L., Rangaraj D., and Keall P. Real-time DMLC IMRT delivery for mobile and deforming targets. Med Phys 32 (2005) 3037-3048
    • (2005) Med Phys , vol.32 , pp. 3037-3048
    • Papiez, L.1    Rangaraj, D.2    Keall, P.3
  • 38
    • 33748555520 scopus 로고    scopus 로고
    • A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a 'breathing' multileaf collimator
    • Webb S., and Binnie D.M. A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a 'breathing' multileaf collimator. Phys Med Biol 51 (2006) 4517-4531
    • (2006) Phys Med Biol , vol.51 , pp. 4517-4531
    • Webb, S.1    Binnie, D.M.2
  • 39
    • 33748537791 scopus 로고    scopus 로고
    • IMRT delivery to a moving target by dynamic MLC tracking: Delivery for targets moving in two dimensions in the beam's eye view
    • McQuaid D., and Webb S. IMRT delivery to a moving target by dynamic MLC tracking: Delivery for targets moving in two dimensions in the beam's eye view. Phys Med Biol 51 (2006) 4819-4839
    • (2006) Phys Med Biol , vol.51 , pp. 4819-4839
    • McQuaid, D.1    Webb, S.2
  • 40
    • 34547460209 scopus 로고    scopus 로고
    • Dynamic-MLC leaf control utilizing on-flight intensity calculations: A robust method for real-time IMRT delivery over moving rigid targets
    • McMahon R., Papiez L., and Rangaraj D. Dynamic-MLC leaf control utilizing on-flight intensity calculations: A robust method for real-time IMRT delivery over moving rigid targets. Med Phys 34 (2007) 3211-3223
    • (2007) Med Phys , vol.34 , pp. 3211-3223
    • McMahon, R.1    Papiez, L.2    Rangaraj, D.3
  • 41
    • 34547334129 scopus 로고    scopus 로고
    • Tracking 'differential organ motion' with a 'breathing' multileaf collimator: Magnitude of problem assessed using 4D CT data and a motion-compensation strategy
    • McClelland J.R., Webb S., McQuaid D., et al. Tracking 'differential organ motion' with a 'breathing' multileaf collimator: Magnitude of problem assessed using 4D CT data and a motion-compensation strategy. Phys Med Biol 52 (2007) 4805-4826
    • (2007) Phys Med Biol , vol.52 , pp. 4805-4826
    • McClelland, J.R.1    Webb, S.2    McQuaid, D.3
  • 42
    • 35848929285 scopus 로고    scopus 로고
    • Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer
    • Tacke M., Nill S., and Oelfke U. Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer. Phys Med Biol 52 (2007) N505-N512
    • (2007) Phys Med Biol , vol.52
    • Tacke, M.1    Nill, S.2    Oelfke, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.