메뉴 건너뛰기




Volumn 91, Issue 3, 2009, Pages 288-295

Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy

Author keywords

Gated beam delivery; Image guided radiotherapy (IGRT); Safety margins; Stereotactic body radiotherapy (SBRT); Tumor tracking

Indexed keywords

ARTICLE; BEAM THERAPY; BREATHING MECHANICS; CANCER RADIOTHERAPY; CLINICAL ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; FOUR DIMENSIONAL IMAGING; HUMAN; IMAGE ANALYSIS; IMAGING AND DISPLAY; INOPERABLE CANCER; LUNG NON SMALL CELL CANCER; LUNG VENTILATION; PATIENT POSITIONING; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE FRACTIONATION; RADIATION SAFETY; STEREOTACTIC BODY RADIATION THERAPY; TUMOR VOLUME;

EID: 65749109343     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2008.08.010     Document Type: Article
Times cited : (112)

References (38)
  • 2
    • 34547510573 scopus 로고    scopus 로고
    • Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study
    • Onishi H., Shirato H., et al. Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study. J Thorac Oncol 2 (2007) S94-100
    • (2007) J Thorac Oncol , vol.2
    • Onishi, H.1    Shirato, H.2
  • 3
    • 41849102670 scopus 로고    scopus 로고
    • Improved accuracy and outcome in radiotherapy of lung cancer
    • Hoyer M. Improved accuracy and outcome in radiotherapy of lung cancer. Radiother Oncol 87 (2008) 1-2
    • (2008) Radiother Oncol , vol.87 , pp. 1-2
    • Hoyer, M.1
  • 4
    • 0037100122 scopus 로고    scopus 로고
    • Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    • Seppenwoolde Y., Shirato H., et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53 (2002) 822-834
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 822-834
    • Seppenwoolde, Y.1    Shirato, H.2
  • 5
    • 33746809041 scopus 로고    scopus 로고
    • Design of 4D treatment planning target volumes
    • Rietzel E., Liu A.K., et al. Design of 4D treatment planning target volumes. Int J Radiat Oncol Biol Phys 66 (2006) 287-295
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 287-295
    • Rietzel, E.1    Liu, A.K.2
  • 6
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall P.J., Mageras G.S., et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33 (2006) 3874-3900
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2
  • 7
    • 0037296427 scopus 로고    scopus 로고
    • Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver
    • Wulf J., Hadinger U., Oppitz U., Thiele W., and Flentje M. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver. Radiother Oncol 66 (2003) 141-150
    • (2003) Radiother Oncol , vol.66 , pp. 141-150
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Thiele, W.4    Flentje, M.5
  • 8
    • 33748875872 scopus 로고    scopus 로고
    • Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors
    • Guckenberger M., Meyer J., et al. Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors. Acta Oncol 45 (2006) 897-906
    • (2006) Acta Oncol , vol.45 , pp. 897-906
    • Guckenberger, M.1    Meyer, J.2
  • 9
    • 34247117297 scopus 로고    scopus 로고
    • Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position
    • Purdie T.G., Bissonnette J.P., et al. Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68 (2007) 243-252
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 243-252
    • Purdie, T.G.1    Bissonnette, J.P.2
  • 10
    • 34047145827 scopus 로고    scopus 로고
    • Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors
    • Guckenberger M., Meyer J., et al. Intra-fractional uncertainties in cone-beam CT based image-guided radiotherapy (IGRT) of pulmonary tumors. Radiother Oncol 83 (2007) 57-64
    • (2007) Radiother Oncol , vol.83 , pp. 57-64
    • Guckenberger, M.1    Meyer, J.2
  • 11
    • 0033831790 scopus 로고    scopus 로고
    • Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit
    • Uematsu M., Shioda A., et al. Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit. Int J Radiat Oncol Biol Phys 48 (2000) 443-448
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 443-448
    • Uematsu, M.1    Shioda, A.2
  • 12
    • 27144516385 scopus 로고    scopus 로고
    • Dose-response in stereotactic irradiation of lung tumors
    • Wulf J., Baier K., Mueller G., and Flentje M.P. Dose-response in stereotactic irradiation of lung tumors. Radiother Oncol 77 (2005) 83-87
    • (2005) Radiother Oncol , vol.77 , pp. 83-87
    • Wulf, J.1    Baier, K.2    Mueller, G.3    Flentje, M.P.4
  • 13
    • 36749019597 scopus 로고    scopus 로고
    • Pulmonary injury and tumor response after stereotactic body radiotherapy (SBRT): results of a serial follow-up CT study
    • Guckenberger M., Heilman K., Wulf J., Mueller G., Beckmann G., and Flentje M. Pulmonary injury and tumor response after stereotactic body radiotherapy (SBRT): results of a serial follow-up CT study. Radiother Oncol 85 (2007) 435-442
    • (2007) Radiother Oncol , vol.85 , pp. 435-442
    • Guckenberger, M.1    Heilman, K.2    Wulf, J.3    Mueller, G.4    Beckmann, G.5    Flentje, M.6
  • 14
    • 33644550948 scopus 로고    scopus 로고
    • Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy
    • Shirato H., Suzuki K., et al. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys 64 (2006) 1229-1236
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1229-1236
    • Shirato, H.1    Suzuki, K.2
  • 15
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy
    • van Herk M., Remeijer P., Rasch C., and Lebesque J.V. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 47 (2000) 1121-1135
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 16
    • 36448988289 scopus 로고    scopus 로고
    • Influence of retrospective sorting on image quality in respiratory correlated computed tomography
    • Guckenberger M., Weininger M., et al. Influence of retrospective sorting on image quality in respiratory correlated computed tomography. Radiother Oncol 85 (2007) 223-231
    • (2007) Radiother Oncol , vol.85 , pp. 223-231
    • Guckenberger, M.1    Weininger, M.2
  • 17
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus J.W., Schneider C., et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 65 (2006) 1560-1571
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1560-1571
    • Wolthaus, J.W.1    Schneider, C.2
  • 18
    • 34547828780 scopus 로고    scopus 로고
    • Four-dimensional treatment planning for stereotactic body radiotherapy
    • Guckenberger M., Wilbert J., et al. Four-dimensional treatment planning for stereotactic body radiotherapy. Int J Radiat Oncol Biol Phys 69 (2007) 276-285
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 276-285
    • Guckenberger, M.1    Wilbert, J.2
  • 19
    • 0034332698 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame
    • Wulf J., Hadinger U., Oppitz U., Olshausen B., and Flentje M. Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. Radiother Oncol 57 (2000) 225-236
    • (2000) Radiother Oncol , vol.57 , pp. 225-236
    • Wulf, J.1    Hadinger, U.2    Oppitz, U.3    Olshausen, B.4    Flentje, M.5
  • 20
    • 39749185557 scopus 로고    scopus 로고
    • Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy
    • Grills I.S., Hugo G., et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys 70 (2008) 1045-1056
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1045-1056
    • Grills, I.S.1    Hugo, G.2
  • 21
    • 36148932560 scopus 로고    scopus 로고
    • On-line target position localization in the presence of respiration: a comparison of two methods
    • Hugo G.D., Liang J., Campbell J., and Yan D. On-line target position localization in the presence of respiration: a comparison of two methods. Int J Radiat Oncol Biol Phys 69 (2007) 1634-1641
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 1634-1641
    • Hugo, G.D.1    Liang, J.2    Campbell, J.3    Yan, D.4
  • 22
    • 34547850184 scopus 로고    scopus 로고
    • Clinical feasibility of using an EPID in cine mode for image-guided verification of stereotactic body radiotherapy
    • Berbeco R.I., Hacker F., Ionascu D., and Mamon H.J. Clinical feasibility of using an EPID in cine mode for image-guided verification of stereotactic body radiotherapy. Int J Radiat Oncol Biol Phys 69 (2007) 258-266
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 258-266
    • Berbeco, R.I.1    Hacker, F.2    Ionascu, D.3    Mamon, H.J.4
  • 23
    • 33646454283 scopus 로고    scopus 로고
    • Tracking moving objects with megavoltage portal imaging: a feasibility study
    • Meyer J., Richter A., Baier K., Wilbert J., Guckenberger M., and Flentje M. Tracking moving objects with megavoltage portal imaging: a feasibility study. Med Phys 33 (2006) 1275-1280
    • (2006) Med Phys , vol.33 , pp. 1275-1280
    • Meyer, J.1    Richter, A.2    Baier, K.3    Wilbert, J.4    Guckenberger, M.5    Flentje, M.6
  • 24
    • 33748859087 scopus 로고    scopus 로고
    • Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: marker placement and early results
    • Nuyttens J.J., Prevost J.B., et al. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: marker placement and early results. Acta Oncol 45 (2006) 961-965
    • (2006) Acta Oncol , vol.45 , pp. 961-965
    • Nuyttens, J.J.1    Prevost, J.B.2
  • 25
    • 24044543599 scopus 로고    scopus 로고
    • Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study
    • D'Souza W.D., Naqvi S.A., and Yu C.X. Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 50 (2005) 4021-4033
    • (2005) Phys Med Biol , vol.50 , pp. 4021-4033
    • D'Souza, W.D.1    Naqvi, S.A.2    Yu, C.X.3
  • 26
    • 33748576243 scopus 로고    scopus 로고
    • Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system
    • Keall P.J., Cattell H., et al. Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system. Int J Radiat Oncol Biol Phys 65 (2006) 1579-1584
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1579-1584
    • Keall, P.J.1    Cattell, H.2
  • 27
    • 50449107824 scopus 로고    scopus 로고
    • Tumor tracking and motion compensation with an adaptive tumor tracking system (ATTS): system description and prototype testing
    • Wilbert J., Meyer J., et al. Tumor tracking and motion compensation with an adaptive tumor tracking system (ATTS): system description and prototype testing. Med Phys 35 (2008) 3911-9921
    • (2008) Med Phys , vol.35 , pp. 3911-9921
    • Wilbert, J.1    Meyer, J.2
  • 28
    • 22544437829 scopus 로고    scopus 로고
    • Semiautomated four-dimensional computed tomography segmentation using deformable models
    • Ragan D., Starkschall G., McNutt T., Kaus M., Guerrero T., and Stevens C.W. Semiautomated four-dimensional computed tomography segmentation using deformable models. Med Phys 32 (2005) 2254-2261
    • (2005) Med Phys , vol.32 , pp. 2254-2261
    • Ragan, D.1    Starkschall, G.2    McNutt, T.3    Kaus, M.4    Guerrero, T.5    Stevens, C.W.6
  • 29
    • 41849136081 scopus 로고    scopus 로고
    • An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors
    • Wu J., Li H., Shekhar R., Suntharalingam M., and D'Souza W. An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors. Radiother Oncol 87 (2008) 35-43
    • (2008) Radiother Oncol , vol.87 , pp. 35-43
    • Wu, J.1    Li, H.2    Shekhar, R.3    Suntharalingam, M.4    D'Souza, W.5
  • 30
    • 38349073449 scopus 로고    scopus 로고
    • Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume
    • Admiraal M.A., Schuring D., and Hurkmans C.W. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume. Radiother Oncol 86 (2008) 55-60
    • (2008) Radiother Oncol , vol.86 , pp. 55-60
    • Admiraal, M.A.1    Schuring, D.2    Hurkmans, C.W.3
  • 31
    • 40949126034 scopus 로고    scopus 로고
    • Optimization of internal margin to account for dosimetric effects of respiratory motion
    • Mutaf Y.D., and Brinkmann D.H. Optimization of internal margin to account for dosimetric effects of respiratory motion. Int J Radiat Oncol Biol Phys 70 (2008) 1561-1570
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1561-1570
    • Mutaf, Y.D.1    Brinkmann, D.H.2
  • 32
  • 33
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • Sonke J.J., Lebesque J., and van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys 70 (2008) 590-598
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    van Herk, M.3
  • 34
    • 18944379885 scopus 로고    scopus 로고
    • Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets
    • Underberg R.W., Lagerwaard F.J., Slotman B.J., Cuijpers J.P., and Senan S. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. Int J Radiat Oncol Biol Phys 62 (2005) 554-560
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 554-560
    • Underberg, R.W.1    Lagerwaard, F.J.2    Slotman, B.J.3    Cuijpers, J.P.4    Senan, S.5
  • 35
    • 38149078236 scopus 로고    scopus 로고
    • Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance
    • Korreman S.S., Juhler-Nottrup T., and Boyer A.L. Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. Radiother Oncol 86 (2008) 61-68
    • (2008) Radiother Oncol , vol.86 , pp. 61-68
    • Korreman, S.S.1    Juhler-Nottrup, T.2    Boyer, A.L.3
  • 36
    • 34247495968 scopus 로고    scopus 로고
    • Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors
    • Gordon J.J., and Siebers J.V. Convolution method and CTV-to-PTV margins for finite fractions and small systematic errors. Phys Med Biol 52 (2007) 1967-1990
    • (2007) Phys Med Biol , vol.52 , pp. 1967-1990
    • Gordon, J.J.1    Siebers, J.V.2
  • 37
    • 34247265495 scopus 로고    scopus 로고
    • The use of spatial dose gradients and probability density function to evaluate the effect of internal organ motion for prostate IMRT treatment planning
    • Jiang R., Barnett R.B., Chow J.C., and Chen J.Z. The use of spatial dose gradients and probability density function to evaluate the effect of internal organ motion for prostate IMRT treatment planning. Phys Med Biol 52 (2007) 1469-1484
    • (2007) Phys Med Biol , vol.52 , pp. 1469-1484
    • Jiang, R.1    Barnett, R.B.2    Chow, J.C.3    Chen, J.Z.4
  • 38
    • 39749145316 scopus 로고    scopus 로고
    • Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients
    • Wolthaus J.W., Sonke J.J., et al. Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 70 (2008) 1229-1238
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1229-1238
    • Wolthaus, J.W.1    Sonke, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.