메뉴 건너뛰기




Volumn 23, Issue 7, 2012, Pages 846-852

The experimental research on two-generation BLB dental implants - Part I: Surface modification and osseointegration

Author keywords

BLB dental implant; Electrophoresis deposition; Micro arc oxidation; Osseointegration; Plasma spraying

Indexed keywords

BIOMATERIAL; TITANIUM;

EID: 84862166937     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2011.02209.x     Document Type: Article
Times cited : (11)

References (38)
  • 1
    • 0031737699 scopus 로고    scopus 로고
    • Hydroxyapatite-coated implants
    • a case against their use.
    • Albrektsson, T. (1998) Hydroxyapatite-coated implants: a case against their use. Journal of Oral and Maxillofacial Surgery56: 1312-1326.
    • (1998) Journal of Oral and Maxillofacial Surgery , vol.56 , pp. 1312-1326
    • Albrektsson, T.1
  • 2
    • 5444236172 scopus 로고    scopus 로고
    • Oral implant surfaces
    • PART 1 - review focusing on topographic and chemical properties of different surfaces and in vivo responses to them.
    • Albrektsson, T. & Wennerberg, A. (2001) Oral implant surfaces: part 1 - review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. International Journal of Prosthodontics17(5): 536-543.
    • (2001) International Journal of Prosthodontics , vol.17 , Issue.5 , pp. 536-543
    • Albrektsson, T.1    Wennerberg, A.2
  • 3
    • 5444243572 scopus 로고    scopus 로고
    • Oral implant surfaces
    • PART 2 - review focusing on clinical knowledge of different surfaces.
    • Albrektsson, T. & Wennerberg, A. (2004) Oral implant surfaces: part 2 - review focusing on clinical knowledge of different surfaces. International Journal of Prosthodontics17: 544-564.
    • (2004) International Journal of Prosthodontics , vol.17 , pp. 544-564
    • Albrektsson, T.1    Wennerberg, A.2
  • 4
    • 33644585074 scopus 로고    scopus 로고
    • Effect of a thin HA coating on the stress/strain distribution in bone around dental implants using three-dimensional finite element analysis
    • Aoki, H., Ozeki, K., Ohtani, Y., Fukui, Y. & Asaoka, T. (2006) Effect of a thin HA coating on the stress/strain distribution in bone around dental implants using three-dimensional finite element analysis. Bio-Medical Materials and Engineering16: 157-169.
    • (2006) Bio-Medical Materials and Engineering , vol.16 , pp. 157-169
    • Aoki, H.1    Ozeki, K.2    Ohtani, Y.3    Fukui, Y.4    Asaoka, T.5
  • 6
    • 0031421084 scopus 로고    scopus 로고
    • Topographical control of cell
    • Curtis, A. & Wilkinson, C. (1997) Topographical control of cell. Biomaterials18: 1573-1583.
    • (1997) Biomaterials , vol.18 , pp. 1573-1583
    • Curtis, A.1    Wilkinson, C.2
  • 7
    • 0036217215 scopus 로고    scopus 로고
    • Surface topography modulates the osteogenesis in human bone marrow cell cultures grown on titanium samples prepared by a combination of mechanical and acid treatments
    • Diniz, M.G., Soares, G.A., Coelho, M.J. & Fernandes, M.H. (2002) Surface topography modulates the osteogenesis in human bone marrow cell cultures grown on titanium samples prepared by a combination of mechanical and acid treatments. Journal of Materials Science: Materials in Medicine13: 421-432.
    • (2002) Journal of Materials Science: Materials in Medicine , vol.13 , pp. 421-432
    • Diniz, M.G.1    Soares, G.A.2    Coelho, M.J.3    Fernandes, M.H.4
  • 8
    • 0242289320 scopus 로고    scopus 로고
    • Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications
    • Frauchiger, V.M., Schlottig, F., Gasser, B. & Textor, M. (2004) Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications. Biomaterials25: 593-606.
    • (2004) Biomaterials , vol.25 , pp. 593-606
    • Frauchiger, V.M.1    Schlottig, F.2    Gasser, B.3    Textor, M.4
  • 9
    • 84862185890 scopus 로고    scopus 로고
    • Clinical research of the application of BLB implant system for 6 years
    • Guo, Q. & Tang, Y. (2005) Clinical research of the application of BLB implant system for 6 years. HEBEI Medicine11: 989-990.
    • (2005) HEBEI Medicine , vol.11 , pp. 989-990
    • Guo, Q.1    Tang, Y.2
  • 11
    • 77952553088 scopus 로고    scopus 로고
    • Biomechanical simulation of various surface roughness and geometric designs on an immediately loaded dental implant
    • Huang, H.L., Hsu, J.T., Fuh, L.J., Lin, D.J. & Chen, M.Y. (2010) Biomechanical simulation of various surface roughness and geometric designs on an immediately loaded dental implant. Computers in Biology and Medicine40: 525-532.
    • (2010) Computers in Biology and Medicine , vol.40 , pp. 525-532
    • Huang, H.L.1    Hsu, J.T.2    Fuh, L.J.3    Lin, D.J.4    Chen, M.Y.5
  • 12
    • 34548394570 scopus 로고    scopus 로고
    • Hydroxyapatite coatings produced on commercially pure titanium by micro-arc oxidation
    • Huang, Y., Wang, Y., Ning, C., Nan, K. & Han, Y. (2007) Hydroxyapatite coatings produced on commercially pure titanium by micro-arc oxidation. Biomedical Materials2: 196-201.
    • (2007) Biomedical Materials , vol.2 , pp. 196-201
    • Huang, Y.1    Wang, Y.2    Ning, C.3    Nan, K.4    Han, Y.5
  • 13
    • 67349123123 scopus 로고    scopus 로고
    • Formation of hydroxyapatite within porous TiO(2) layer by micro-arc oxidation coupled with electrophoretic deposition
    • Kim, D.Y., Kim, M., Kim, H.E., Koh, Y.H., Kim, H.W. & Jang, J.H. (2009) Formation of hydroxyapatite within porous TiO(2) layer by micro-arc oxidation coupled with electrophoretic deposition. Acta Biomaterialia5: 2196-2205.
    • (2009) Acta Biomaterialia , vol.5 , pp. 2196-2205
    • Kim, D.Y.1    Kim, M.2    Kim, H.E.3    Koh, Y.H.4    Kim, H.W.5    Jang, J.H.6
  • 15
    • 0036166394 scopus 로고    scopus 로고
    • Properties of osteoconductive biomaterials
    • calcium phosphates.
    • LeGeros, R.Z. (2002) Properties of osteoconductive biomaterials: calcium phosphates. Clinical Orthopaedics and Related Research395: 81-98.
    • (2002) Clinical Orthopaedics and Related Research , vol.395 , pp. 81-98
    • LeGeros, R.Z.1
  • 16
    • 1042287251 scopus 로고    scopus 로고
    • Improved biological performance of Ti implants due to surface modification by micro-arc oxidation
    • Li, L.H., Kong, Y.M., Kim, H.W., Kim, Y.W., Kim, H.E., Heo, S.J. & Koak, J.Y. (2004) Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. Biomaterials25: 2867-2875.
    • (2004) Biomaterials , vol.25 , pp. 2867-2875
    • Li, L.H.1    Kong, Y.M.2    Kim, H.W.3    Kim, Y.W.4    Kim, H.E.5    Heo, S.J.6    Koak, J.Y.7
  • 17
    • 84873062399 scopus 로고    scopus 로고
    • A clinic application and evaluation of short- term results on BLB implant system
    • Liao, X., Tian, W. & Sui, J., et al. (2007) A clinic application and evaluation of short- term results on BLB implant system. Chinese Journal of Oral Implantology2: 73-75.
    • (2007) Chinese Journal of Oral Implantology , vol.2 , pp. 73-75
    • Liao, X.1    Tian, W.2    Sui, J.3
  • 18
    • 0032403059 scopus 로고    scopus 로고
    • Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition
    • Lincks, J., Boyan, B.D., Blanchard, C.R., Lohmann, C.H., Liu, Y., Cochran, D.L., Dean, D.D. & Schwartz, Z. (1998) Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition. Biomaterials19: 2219-2232.
    • (1998) Biomaterials , vol.19 , pp. 2219-2232
    • Lincks, J.1    Boyan, B.D.2    Blanchard, C.R.3    Lohmann, C.H.4    Liu, Y.5    Cochran, D.L.6    Dean, D.D.7    Schwartz, Z.8
  • 19
    • 84969317422 scopus 로고    scopus 로고
    • Clinical application and evaluation of BLB implant system
    • Luo, C. & Lv, Z. (2005) Clinical application and evaluation of BLB implant system. Beijing Journal of Stomatology13: 47-49.
    • (2005) Beijing Journal of Stomatology , vol.13 , pp. 47-49
    • Luo, C.1    Lv, Z.2
  • 20
    • 64249102943 scopus 로고    scopus 로고
    • Transmission electron microscopy of coatings formed by plasma electrolytic oxidation of titanium
    • Matykina, E., Arrabal, R., Skeldon, P. & Thompson, G.E. (2009) Transmission electron microscopy of coatings formed by plasma electrolytic oxidation of titanium. Acta Biomaterialia5: 1356-1366.
    • (2009) Acta Biomaterialia , vol.5 , pp. 1356-1366
    • Matykina, E.1    Arrabal, R.2    Skeldon, P.3    Thompson, G.E.4
  • 23
    • 0035892390 scopus 로고    scopus 로고
    • Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique
    • Nie, X., Leyland, A., Matthews, A., Jiang, J.C. & Meletis, E.I. (2001) Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique. Journal of Biomedical Material Research57: 612-618.
    • (2001) Journal of Biomedical Material Research , vol.57 , pp. 612-618
    • Nie, X.1    Leyland, A.2    Matthews, A.3    Jiang, J.C.4    Meletis, E.I.5
  • 24
    • 3342946038 scopus 로고    scopus 로고
    • Roughness and bonding strength of bioactive apatite layer on dental implants
    • Nogueras-Bayona, J., Gil, F.J., Salsench, J. & Martinez-Gomis, J. (2004) Roughness and bonding strength of bioactive apatite layer on dental implants. Implant Dentistry13: 185-189.
    • (2004) Implant Dentistry , vol.13 , pp. 185-189
    • Nogueras-Bayona, J.1    Gil, F.J.2    Salsench, J.3    Martinez-Gomis, J.4
  • 25
    • 0034489967 scopus 로고    scopus 로고
    • Hydroxyapatites and their use as coatings in dental implants
    • a review.
    • Ong, J.L. & Chan, D.C.N. (2000) Hydroxyapatites and their use as coatings in dental implants: a review. Critical Reviews in Biomedical Engineering28: 667-707.
    • (2000) Critical Reviews in Biomedical Engineering , vol.28 , pp. 667-707
    • Ong, J.L.1    Chan, D.C.N.2
  • 26
    • 14844350576 scopus 로고    scopus 로고
    • The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae
    • Park, Y.S., Yi, K.Y., Lee, I.S., Han, C.H. & Jung, Y.C. (2005) The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae. The International Journal of Oral & Maxillofacial Implants20: 31-38.
    • (2005) The International Journal of Oral & Maxillofacial Implants , vol.20 , pp. 31-38
    • Park, Y.S.1    Yi, K.Y.2    Lee, I.S.3    Han, C.H.4    Jung, Y.C.5
  • 27
    • 37349093436 scopus 로고    scopus 로고
    • Biomimetic apatite induction of P-containing titania formed by micro-arc oxidation before and after hydrothermal treatment
    • Ryu, H.S., Song, W.H. & Hong, S.H. (2008) Biomimetic apatite induction of P-containing titania formed by micro-arc oxidation before and after hydrothermal treatment. Surface Coating Technology202: 1853-1858.
    • (2008) Surface Coating Technology , vol.202 , pp. 1853-1858
    • Ryu, H.S.1    Song, W.H.2    Hong, S.H.3
  • 29
    • 27644562633 scopus 로고    scopus 로고
    • Apatite induction on Ca-containing titania formed by micro-arc oxidation
    • Song, W.H., Ryu, H.S. & Hong, S.H. (2005) Apatite induction on Ca-containing titania formed by micro-arc oxidation. Journal of the American Ceramic Society88: 2642-2644.
    • (2005) Journal of the American Ceramic Society , vol.88 , pp. 2642-2644
    • Song, W.H.1    Ryu, H.S.2    Hong, S.H.3
  • 30
    • 3242662480 scopus 로고
    • Hydroxyapatite coatings on dental implants
    • benefits and risks. : -.
    • Steflik, D.E. (1994) Hydroxyapatite coatings on dental implants: benefits and risks. Journal of Oral Implantology20: 198-209.
    • (1994) Journal of Oral Implantology , vol.20 , pp. 198-209
    • Steflik, D.E.1
  • 31
  • 32
    • 0038016683 scopus 로고    scopus 로고
    • The significance of the surface properties of oxidized titanium to the bone response
    • special emphasis on potential biochemical bonding of oxidized titanium implant.
    • Sul, Y.T. (2003) The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials24: 3893-3907.
    • (2003) Biomaterials , vol.24 , pp. 3893-3907
    • Sul, Y.T.1
  • 33
    • 22544447809 scopus 로고    scopus 로고
    • The bone response of oxidized bioactive and non-bioactive Titanium implants
    • Sul, Y.T., Johansson, C., Byon, E. & Albrektsson, T. (2005) The bone response of oxidized bioactive and non-bioactive Titanium implants. Biomaterials26: 6720-6730.
    • (2005) Biomaterials , vol.26 , pp. 6720-6730
    • Sul, Y.T.1    Johansson, C.2    Byon, E.3    Albrektsson, T.4
  • 36
    • 0029655580 scopus 로고    scopus 로고
    • Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topography
    • Wennerberg, A., Albrektsson, T., Johansson, C. & Andersson, B. (1996) Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topography. Biomaterials17: 15-21.
    • (1996) Biomaterials , vol.17 , pp. 15-21
    • Wennerberg, A.1    Albrektsson, T.2    Johansson, C.3    Andersson, B.4
  • 38
    • 77955908223 scopus 로고    scopus 로고
    • Synthesis and properties of hydroxyapatite-containing porous titania coating on ultrafine-grained titanium by micro-arc oxidation
    • Yao, Z.Q., Ivanisenko, Y., Diemant, T., Caron, A., Chuvilin, A., Jiang, J.Z., Valiev, R.Z., Qi, M. & Fecht, H.J. (2010) Synthesis and properties of hydroxyapatite-containing porous titania coating on ultrafine-grained titanium by micro-arc oxidation. Acta Biomaterialia6: 2816-2825.
    • (2010) Acta Biomaterialia , vol.6 , pp. 2816-2825
    • Yao, Z.Q.1    Ivanisenko, Y.2    Diemant, T.3    Caron, A.4    Chuvilin, A.5    Jiang, J.Z.6    Valiev, R.Z.7    Qi, M.8    Fecht, H.J.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.