Volumn 47, Issue 7, 2012, Pages 415-421

Normalized metal artifact reduction in head and neck computed tomography

Author keywords

computed tomography; dental hardware; magnetic resonance imaging; metal artifact reduction; sinogram interpolation

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DENTAL RADIOLOGY; DENTURE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE QUALITY; MALE; METAL ARTIFACT REDUCTION; MOUTH CAVITY; NUCLEAR MAGNETIC RESONANCE IMAGING; OROPHARYNX; PRIORITY JOURNAL; STANDARD;

EID: 84862149869     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3182532f17     Document Type: Article
Times cited : (64)

References (32)
  • 1
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987;164:576-577. (Pubitemid 17097989)
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 2
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • DOI 10.1118/1.595032
    • Glover GH, Pelc NJ. An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med Phys. 1981;8:799-807. (Pubitemid 12249662)
    • (1981) Medical Physics , vol.8 , Issue.6 , pp. 799-807
    • Glover, G.H.1    Pelc, N.J.2
  • 3
    • 79959376217 scopus 로고    scopus 로고
    • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    • Bamberg F, Dierks A, Nikolaou K, et al. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol. 2011; 21:1424-1429.
    • (2011) Eur Radiol , vol.21 , pp. 1424-1429
    • Bamberg, F.1    Dierks, A.2    Nikolaou, K.3
  • 4
    • 80052366712 scopus 로고    scopus 로고
    • Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures
    • Zhou C, Zhao YE, Luo S, et al. Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures. Acad Radiol. 2011;18:1252-1257.
    • (2011) Acad Radiol , vol.18 , pp. 1252-1257
    • Zhou, C.1    Zhao, Y.E.2    Luo, S.3
  • 5
    • 78650117233 scopus 로고    scopus 로고
    • Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm
    • Abdoli M, Ay MR, Ahmadian A, et al. Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm. Med Phys. 2010;37:6166-6177.
    • (2010) Med Phys , vol.37 , pp. 6166-6177
    • Abdoli, M.1    Ay, M.R.2    Ahmadian, A.3
  • 6
    • 77957695023 scopus 로고    scopus 로고
    • Normalized metal artifact reduction (NMAR) in computed tomography
    • Meyer E, Raupach R, Lell M, et al. Normalized metal artifact reduction (NMAR) in computed tomography. Med Phys. 2010;37:5482-5493.
    • (2010) Med Phys , vol.37 , pp. 5482-5493
    • Meyer, E.1    Raupach, R.2    Lell, M.3
  • 7
    • 77958483245 scopus 로고    scopus 로고
    • Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach
    • Prell D, Kyriakou Y, Kachelriess M, et al. Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach. Invest Radiol. 2010;45:747-754.
    • (2010) Invest Radiol , vol.45 , pp. 747-754
    • Prell, D.1    Kyriakou, Y.2    Kachelriess, M.3
  • 9
    • 59449107042 scopus 로고    scopus 로고
    • Suppression of metal artifacts in CT using a reconstruction procedure that combines MAP and projection completion
    • Lemmens C, Faul D, Nuyts J. Suppression of metal artifacts in CT using a reconstruction procedure that combines MAP and projection completion. IEEE Trans Med Imaging. 2009;28:250-260.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 250-260
    • Lemmens, C.1    Faul, D.2    Nuyts, J.3
  • 10
    • 0033853232 scopus 로고    scopus 로고
    • Fast iterative algorithm for metal artifact reduction in X-ray CT
    • Wang G, Frei T, Vannier MW. Fast iterative algorithm for metal artifact reduction in X-ray CT. Acad Radiol. 2000;7:607-614. (Pubitemid 30602828)
    • (2000) Academic Radiology , vol.7 , Issue.8 , pp. 607-614
    • Wang, G.1    Frei, T.2    Vannier, M.W.3
  • 12
    • 0033431430 scopus 로고    scopus 로고
    • Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    • Wang G, Vannier MW, Cheng PC. Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction. Microsc Microanal. 1999; 5:58-65. (Pubitemid 129479946)
    • (1999) Microscopy and Microanalysis , vol.5 , Issue.1 , pp. 58-65
    • Wang, G.1    Vannier, M.W.2    Cheng, P.-C.3
  • 13
    • 79551662218 scopus 로고    scopus 로고
    • Metal artifact reduction in X-ray computed tomography (CT) by constrained optimization
    • Zhang X, Wang J, Xing L. Metal artifact reduction in X-ray computed tomography (CT) by constrained optimization. Med Phys. 2011;38:701-711.
    • (2011) Med Phys , vol.38 , pp. 701-711
    • Zhang, X.1    Wang, J.2    Xing, L.3
  • 14
    • 61849155366 scopus 로고    scopus 로고
    • Penalized-likelihood reconstruction for metal artifact reduction in cone-beam CT
    • Aootaphao S, Pintavirooj C, Sotthivirat S. Penalized-likelihood reconstruction for metal artifact reduction in cone-beam CT. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:2733-2736.
    • (2008) Conf Proc IEEE Eng Med Biol Soc , vol.2008 , pp. 2733-2736
    • Aootaphao, S.1    Pintavirooj, C.2    Sotthivirat, S.3
  • 15
    • 34249330334 scopus 로고    scopus 로고
    • Statistical image reconstruction for inconsistent CT projection data
    • DOI 10.1160/Me9041
    • Buzug T, Oehler M. Statistical image reconstruction for inconsistent CT projection data. Methods Inf Med. 2007;46:261-269. (Pubitemid 46807196)
    • (2007) Methods of Information in Medicine , vol.46 , Issue.3 , pp. 261-269
    • Oehler, M.1    Buzug, T.M.2
  • 16
    • 79952363437 scopus 로고    scopus 로고
    • Metal artifact reduction in dental CT images using polar mathematical morphology
    • Naranjo V, Llorens R, Alcaniz M, et al. Metal artifact reduction in dental CT images using polar mathematical morphology. Comput Methods Programs Biomed. 2011;102:64-74.
    • (2011) Comput Methods Programs Biomed , vol.102 , pp. 64-74
    • Naranjo, V.1    Llorens, R.2    Alcaniz, M.3
  • 17
    • 49949095531 scopus 로고    scopus 로고
    • Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: A comparison of published methods
    • Rinkel J, Dillon WP, Funk T, et al. Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods. J Comput Assist Tomogr. 2008; 32:621-629.
    • (2008) J Comput Assist Tomogr , vol.32 , pp. 621-629
    • Rinkel, J.1    Dillon, W.P.2    Funk, T.3
  • 18
    • 2542496945 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
    • DOI 10.1007/s00330-004-2263-y
    • Watzke O, KalenderWA. A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images. Eur Radiol. 2004;14:849-856. (Pubitemid 38678906)
    • (2004) European Radiology , vol.14 , Issue.5 , pp. 849-856
    • Watzke, O.1    Kalender, W.A.2
  • 20
    • 79960230514 scopus 로고    scopus 로고
    • Reference-free ground truth metric for metal artifact evaluation in CT images
    • Kratz B, Ens S, Muller J, et al. Reference-free ground truth metric for metal artifact evaluation in CT images. Med Phys. 2011;38:4321-4328.
    • (2011) Med Phys , vol.38 , pp. 4321-4328
    • Kratz, B.1    Ens, S.2    Muller, J.3
  • 22
    • 75749108974 scopus 로고    scopus 로고
    • Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
    • Veldkamp WJ, Joemai RM, van der Molen AJ, et al. Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. Med Phys. 2010;37:620-628.
    • (2010) Med Phys , vol.37 , pp. 620-628
    • Veldkamp, W.J.1    Joemai, R.M.2    Van Der Molen, A.J.3
  • 23
    • 73949111106 scopus 로고    scopus 로고
    • Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: Techniques and initial clinical results
    • Yu L, Li H, Mueller J, et al. Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results. Invest Radiol. 2009;44:691-696.
    • (2009) Invest Radiol , vol.44 , pp. 691-696
    • Yu, L.1    Li, H.2    Mueller, J.3
  • 24
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • DOI 10.1118/1.1358303
    • Kachelriess M, Watzke O, Kalender WA. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and conebeam CT. Med Phys. 2001;28:475-490. (Pubitemid 32323299)
    • (2001) Medical Physics , vol.28 , Issue.4 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 25
    • 0017810277 scopus 로고
    • A method for correcting bone induced artifacts in computed tomography scanners
    • Joseph PM, Spital RD. A method for correcting bone induced artifacts in computed tomography scanners. J Comput Assist Tomogr. 1978;2:100-108. (Pubitemid 8260665)
    • (1978) Journal of Computer Assisted Tomography , vol.2 , Issue.1 , pp. 100-108
    • Joseph, P.M.1    Spital, R.D.2
  • 26
    • 77957712398 scopus 로고    scopus 로고
    • Empirical beam hardening correction (EBHC) for CT
    • Kyriakou Y, Meyer E, Prell D, et al. Empirical beam hardening correction (EBHC) for CT. Med Phys. 2010;37:5179-5187.
    • (2010) Med Phys , vol.37 , pp. 5179-5187
    • Kyriakou, Y.1    Meyer, E.2    Prell, D.3
  • 27
    • 34547145165 scopus 로고    scopus 로고
    • G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    • Faul F, Erdfelder E, Lang AG, et al. G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175-191.
    • (2007) Behav Res Methods , vol.39 , pp. 175-191
    • Faul, F.1    Erdfelder, E.2    Lang, A.G.3
  • 28
    • 34249857538 scopus 로고    scopus 로고
    • Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT
    • Lee MJ, Kim S, Lee SA, et al. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. Radiographics. 2007;27:791-803.
    • (2007) Radiographics , vol.27 , pp. 791-803
    • Lee, M.J.1    Kim, S.2    Lee, S.A.3
  • 29
    • 77950872007 scopus 로고    scopus 로고
    • Accelerated slice encoding for metal artifact correction
    • Hargreaves BA, Chen W, Lu W, et al. Accelerated slice encoding for metal artifact correction. J Magn Reson Imaging. 2010;31:987-996.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 987-996
    • Hargreaves, B.A.1    Chen, W.2    Lu, W.3
  • 30
    • 80052229444 scopus 로고    scopus 로고
    • MRI after arthroplasty: Comparison of MAVRIC and conventional fast spin-echo techniques
    • W405YW411
    • Hayter CL, Koff MF, Shah P, et al. MRI after arthroplasty: comparison of MAVRIC and conventional fast spin-echo techniques. AJR Am J Roentgenol. 2011; 197:W405YW411.
    • (2011) AJR Am J Roentgenol , pp. 197
    • Hayter, C.L.1    Koff, M.F.2    Shah, P.3
  • 31
    • 34250170177 scopus 로고    scopus 로고
    • The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners
    • DOI 10.1007/s11517-007-0188-8
    • Kennedy JA, Israel O, Frenkel A, et al. The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners. Med Biol Eng Comput. 2007;45:553-562. (Pubitemid 46902062)
    • (2007) Medical and Biological Engineering and Computing , vol.45 , Issue.6 , pp. 553-562
    • Kennedy, J.A.1    Israel, O.2    Frenkel, A.3    Bar-Shalom, R.4    Azhari, H.5
  • 32
    • 70449640457 scopus 로고    scopus 로고
    • Evaluation of the impact of dental artefacts on intensity-modulated radiotherapy planning for the head and neck
    • Webster GJ, Rowbottom CG, Mackay RI. Evaluation of the impact of dental artefacts on intensity-modulated radiotherapy planning for the head and neck. Radiother Oncol. 2009;93:553-558.
    • (2009) Radiother Oncol , vol.93 , pp. 553-558
    • Webster, G.J.1    Rowbottom, C.G.2    MacKay, R.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.