메뉴 건너뛰기




Volumn 46, Issue 3, 2007, Pages 261-269

Statistical image reconstruction for inconsistent CT projection data

Author keywords

Artifacts; Computer assisted image processing; Image reconstruction; Transmission computed tomography

Indexed keywords

AMALGAM;

EID: 34249330334     PISSN: 00261270     EISSN: None     Source Type: Journal    
DOI: 10.1160/Me9041     Document Type: Article
Times cited : (52)

References (47)
  • 1
    • 0018362885 scopus 로고
    • Nonlinear Polychromatic and Noise Artifacts in X-Ray Computed Tomography Images
    • Duerinckx AJ, Markovski A. Nonlinear Polychromatic and Noise Artifacts in X-Ray Computed Tomography Images. J Comput Assist Tomogr 1979; 3: 519-526.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 519-526
    • Duerinckx, A.J.1    Markovski, A.2
  • 2
    • 0018177738 scopus 로고
    • Polychromatic Streak Artifacts in Computed Tomography Images
    • Duerinckx AJ, Macovski A. Polychromatic Streak Artifacts in Computed Tomography Images. J Comput Assist Tomogr 1978; 2: 481-487.
    • (1978) J Comput Assist Tomogr , vol.2 , pp. 481-487
    • Duerinckx, A.J.1    Macovski, A.2
  • 3
    • 0017810277 scopus 로고
    • A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
    • Joseph PM, Spital RD. A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners. J Comput Assist Tomogr 1978; 2: 100-108.
    • (1978) J Comput Assist Tomogr , vol.2 , pp. 100-108
    • Joseph, P.M.1    Spital, R.D.2
  • 4
    • 0022471628 scopus 로고
    • Quantitative bone measurements using x-ray computed tomography with second order correction
    • Robertson DD, Huang HK. Quantitative bone measurements using x-ray computed tomography with second order correction. Med Phys 1986; 13: 474-479.
    • (1986) Med Phys , vol.13 , pp. 474-479
    • Robertson, D.D.1    Huang, H.K.2
  • 5
    • 0025478201 scopus 로고    scopus 로고
    • Meagher JM, Mote CD, Skinner HB. CT Image Correction for Beam Hardening Using Simulated Projection Data. IEEE Trans on Nucl Sci 1990; 37: 1520-1524.
    • Meagher JM, Mote CD, Skinner HB. CT Image Correction for Beam Hardening Using Simulated Projection Data. IEEE Trans on Nucl Sci 1990; 37: 1520-1524.
  • 6
    • 0030867231 scopus 로고    scopus 로고
    • A method for simultaneous correction of spectrum hardening artefacts in CT images containing both bone and iodine
    • Joseph PM, Ruth C. A method for simultaneous correction of spectrum hardening artefacts in CT images containing both bone and iodine. Med Phys 1997; 24: 1629-1634.
    • (1997) Med Phys , vol.24 , pp. 1629-1634
    • Joseph, P.M.1    Ruth, C.2
  • 8
  • 10
    • 0019460905 scopus 로고
    • The exponential edge-gradient effect in x-ray computed tomography
    • Joseph PM, Spital RD. The exponential edge-gradient effect in x-ray computed tomography. Phys Med Biol 1980; 26: 473-487.
    • (1980) Phys Med Biol , vol.26 , pp. 473-487
    • Joseph, P.M.1    Spital, R.D.2
  • 11
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Glover GH, Pelc NH. An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med Phys 1981; 8: 799-807.
    • (1981) Med Phys , vol.8 , pp. 799-807
    • Glover, G.H.1    Pelc, N.H.2
  • 13
    • 0019166396 scopus 로고
    • View sampling requirements in fan beam computed tomography
    • Joseph PM, Schulz RA. View sampling requirements in fan beam computed tomography. Med Phys 1980; 7: 692-702.
    • (1980) Med Phys , vol.7 , pp. 692-702
    • Joseph, P.M.1    Schulz, R.A.2
  • 14
    • 0018819516 scopus 로고
    • Nonlinear partial volume artefacts in x-ray computed tomography
    • Glover GH, Pelc NJ. Nonlinear partial volume artefacts in x-ray computed tomography. Med Phys 1980; 7: 238-248.
    • (1980) Med Phys , vol.7 , pp. 238-248
    • Glover, G.H.1    Pelc, N.J.2
  • 15
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 1984; 8: 306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 16
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology 1987; 164: 576-577.
    • (1987) Radiology , vol.164 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 17
    • 0017955879 scopus 로고
    • Image reconstruction from projections III: Projection completion methods (theory)
    • Lewis RM, Bates RHT. Image reconstruction from projections III: Projection completion methods (theory). Optik 1978; 50: 189-204.
    • (1978) Optik , vol.50 , pp. 189-204
    • Lewis, R.M.1    Bates, R.H.T.2
  • 18
    • 0020845935 scopus 로고
    • Iterative convolution backprojection algorithms for image reconstruction from limited data
    • Medoff BP, Brody WR, Nassi M, Macovski A. Iterative convolution backprojection algorithms for image reconstruction from limited data. J Opt Soc Am 1983; 73: 1493-1500.
    • (1983) J Opt Soc Am , vol.73 , pp. 1493-1500
    • Medoff, B.P.1    Brody, W.R.2    Nassi, M.3    Macovski, A.4
  • 19
    • 0018349307 scopus 로고
    • Computed Tomography Reconstruction from Hollow Projections: An Application to In Vivo Evaluation of Artificial Hip Joints
    • Hinderling T, Rüegsegger P, Anliker M, Dietsschi C. Computed Tomography Reconstruction from Hollow Projections: An Application to In Vivo Evaluation of Artificial Hip Joints. J Comp Assist Tomogr 1979; 3: 52-57.
    • (1979) J Comp Assist Tomogr , vol.3 , pp. 52-57
    • Hinderling, T.1    Rüegsegger, P.2    Anliker, M.3    Dietsschi, C.4
  • 20
    • 17144438952 scopus 로고
    • Algorithms for reduction of CT artifacts caused by metallic implants
    • Klotz E, Kalender WA, Sokiranski R, Felsenberg D. Algorithms for reduction of CT artifacts caused by metallic implants. Proceedings SPIE 1990; 1234. 642-650.
    • (1990) Proceedings SPIE , vol.1234 , pp. 642-650
    • Klotz, E.1    Kalender, W.A.2    Sokiranski, R.3    Felsenberg, D.4
  • 21
    • 0020368923 scopus 로고
    • Anchorage of Femoral Implants Visualized by Modified Computed Tomography
    • Seitz P, Rüegsegger P. Anchorage of Femoral Implants Visualized by Modified Computed Tomography. Arch Orthop Trauma Surg 1982; 100: 261-266.
    • (1982) Arch Orthop Trauma Surg , vol.100 , pp. 261-266
    • Seitz, P.1    Rüegsegger, P.2
  • 22
    • 0007976796 scopus 로고
    • CT bone densitometry of the anchorage of artificial knee joints
    • Seitz P, Rüegsegger P. CT bone densitometry of the anchorage of artificial knee joints. J Comp Assist Tomogr 1985; 9: 621-622.
    • (1985) J Comp Assist Tomogr , vol.9 , pp. 621-622
    • Seitz, P.1    Rüegsegger, P.2
  • 23
    • 0001404455 scopus 로고
    • A post-processing algorithm to reduce metallic clip artifacts in CT images
    • Tuy HK. A post-processing algorithm to reduce metallic clip artifacts in CT images. Eur Radiol 1981; 3: 129-134.
    • (1981) Eur Radiol , vol.3 , pp. 129-134
    • Tuy, H.K.1
  • 24
    • 0040224959 scopus 로고
    • Reduction of artefacts caused by metallic objects in CT
    • Lonn AHR, Crawford CR. Reduction of artefacts caused by metallic objects in CT. Radiology 1988; 169: 116.
    • (1988) Radiology , vol.169 , pp. 116
    • Lonn, A.H.R.1    Crawford, C.R.2
  • 26
    • 0034351113 scopus 로고    scopus 로고
    • X-Ray CT Metal Artifact Reduction Using Wavelets: An Application for Imaging Total Hip Prostheses
    • Zhao S, Robertson DD, Wang G, Whiting B, Bae K. X-Ray CT Metal Artifact Reduction Using Wavelets: An Application for Imaging Total Hip Prostheses. IEEE Trans Med Imaging 2000; 19: 1238-1247.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.5
  • 28
    • 0030983762 scopus 로고    scopus 로고
    • Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring Reconstruction
    • Robertson DD, Yuan J, Wang G, Vannier MW. Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring Reconstruction. J Comput Assist Tomogr 1997; 21: 293-298.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3    Vannier, M.W.4
  • 30
    • 0005170559 scopus 로고
    • Reconstruction tomography from incomplete projections
    • Ter-Pogossian M ed, Baltimore, MD: University Park;
    • Oppenheim BE. Reconstruction tomography from incomplete projections. In: Ter-Pogossian M (ed). Reconstruction Tomography in Diagnostic Radiology and Nuclear Medicine. Baltimore, MD: University Park; 1977. pp 155-183.
    • (1977) Reconstruction Tomography in Diagnostic Radiology and Nuclear Medicine , pp. 155-183
    • Oppenheim, B.E.1
  • 32
    • 34249293192 scopus 로고    scopus 로고
    • Philips Medical System. Service Manual System Tomoscan M/EG MCT 3501/MCT 3902.1996.
    • Philips Medical System. Service Manual System Tomoscan M/EG MCT 3501/MCT 3902.1996.
  • 33
    • 34249281874 scopus 로고    scopus 로고
    • CIRS Incorporated Tissue Simulation and Phantom Technology (homepage on the Internet). Computerized Imaging Reference Systems, Inc.; c2005 (updated 2005; cited Sep 30, 2006). Available from: http://www.cirsinc.com/602_ct_xray. html
    • CIRS Incorporated Tissue Simulation and Phantom Technology (homepage on the Internet). Computerized Imaging Reference Systems, Inc.; c2005 (updated 2005; cited Sep 30, 2006). Available from: http://www.cirsinc.com/602_ct_xray. html
  • 35
    • 0034446966 scopus 로고    scopus 로고
    • Image Inpainting. Computer Graphics
    • Bertalmio M, Sapira G. Image Inpainting. Computer Graphics; SIGGRAPH2000. 2000; 417-24.
    • (2000) SIGGRAPH2000 , pp. 417-424
    • Bertalmio, M.1    Sapira, G.2
  • 36
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982; 1: 113-121.
    • (1982) IEEE Trans Med Imaging , vol.1 , pp. 113-121
    • Shepp, L.A.1    Vardi, Y.2
  • 38
    • 0002030206 scopus 로고
    • Bayesian image analysis: An application to single photon emission tomography
    • Washington DC
    • Geman S, Mc Clure D. Bayesian image analysis: An application to single photon emission tomography. In: Proceedings of Stat Comp Sect of Amer Stat Assoc; 1985. Washington DC. 1985; pp 12-18.
    • (1985) Proceedings of Stat Comp Sect of Amer Stat Assoc , pp. 12-18
    • Geman, S.1    Mc Clure, D.2
  • 39
    • 0021518209 scopus 로고
    • Stochastic Relaxation, Gibbs Distributions and the Bayesian Restoration of Images
    • Geman S, Geman D. Stochastic Relaxation, Gibbs Distributions and the Bayesian Restoration of Images. IEEE Trans on Patt Anal and Mach Intel 1984; 6: 721-741.
    • (1984) IEEE Trans on Patt Anal and Mach Intel , vol.6 , pp. 721-741
    • Geman, S.1    Geman, D.2
  • 40
    • 0028446166 scopus 로고
    • Penalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomography
    • Fessler JA. Penalized Weighted Least-Squares Image Reconstruction for Positron Emission Tomography. IEEE Trans Med Imaging 1984; 13: 290-300.
    • (1984) IEEE Trans Med Imaging , vol.13 , pp. 290-300
    • Fessler, J.A.1
  • 41
    • 0034206972 scopus 로고    scopus 로고
    • Reduction of metal streak artefacts in x-ray computed tomography using a transmission maximum a posteriori algorithm
    • De Man B, Nuyts J, Dupont P, Marchal G, Suetens P. Reduction of metal streak artefacts in x-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Trans Nucl Sci 2003; 47: 977-981.
    • (2003) IEEE Trans Nucl Sci , vol.47 , pp. 977-981
    • De Man, B.1    Nuyts, J.2    Dupont, P.3    Marchal, G.4    Suetens, P.5
  • 42
    • 0025404969 scopus 로고
    • Bayesian reconstruction from emission tomography data using a modified EM algorithm
    • Green PJ. Bayesian reconstruction from emission tomography data using a modified EM algorithm. IEEE Trans Med Imaging 1990; 9: 84-93.
    • (1990) IEEE Trans Med Imaging , vol.9 , pp. 84-93
    • Green, P.J.1
  • 43
    • 34249286473 scopus 로고    scopus 로고
    • Generalized Geman prior for iterative reconstruction
    • De Man B, Basu S. Generalized Geman prior for iterative reconstruction. Proceedings of Biomedizinische Technik 2005; 50 (1): 358-359.
    • (2005) Proceedings of Biomedizinische Technik , vol.50 , Issue.1 , pp. 358-359
    • De Man, B.1    Basu, S.2
  • 44
    • 0029394375 scopus 로고
    • Globally convergent algorithm for maximum a posteriori transmission tomography
    • Lange K, Fessler JA. Globally convergent algorithm for maximum a posteriori transmission tomography. IEEE Trans Image Process 1995; 4: 1430-1438.
    • (1995) IEEE Trans Image Process , vol.4 , pp. 1430-1438
    • Lange, K.1    Fessler, J.A.2
  • 45
    • 0030109399 scopus 로고    scopus 로고
    • Bouman CA, Sauer K. A Unified Approach to Statistical Tomography Using Coordinate Descent Optimization. IEEE Trans Med Imaging 1996; 5: 480-491.
    • Bouman CA, Sauer K. A Unified Approach to Statistical Tomography Using Coordinate Descent Optimization. IEEE Trans Med Imaging 1996; 5: 480-491.
  • 46
    • 0027542459 scopus 로고    scopus 로고
    • Sauer K, Bouman C. A Local Update Strategy for iterative Reconstructions from projections. IEEE Trans Signal Process 1993; 41: 534-548.
    • Sauer K, Bouman C. A Local Update Strategy for iterative Reconstructions from projections. IEEE Trans Signal Process 1993; 41: 534-548.
  • 47
    • 0025587714 scopus 로고
    • Convergence of EM Image Reconstruction Algorithms with Gibbs Priors
    • Lange K. Convergence of EM Image Reconstruction Algorithms with Gibbs Priors. IEEE Trans Med Imaging 1990; 9: 439-446.
    • (1990) IEEE Trans Med Imaging , vol.9 , pp. 439-446
    • Lange, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.